수질자동측정망 자료의 항목별 이상치 비교 분석 (Comparative Analysis on the Outlier Data of Each Parameter in Automatic Water Quality Monitoring Networks)

  • 임병진;홍은영;연인성
    • 한국물환경학회지
    • /
    • 제26권4호
    • /
    • pp.700-706
    • /
    • 2010
  • Along the 4 major rivers in korea, there are automatic water quality monitoring (AWQM) stations to immediately respond to any pollution incident. Real-time data (temperature, DO, pH, EC and TOC) collected at each station were statistically treated to exclude outliers and keep valid data using Dixon's test and Discordance test. These applied methods were compared in terms of the number of the outliers sorted out. There was no significant difference between these methods. On the other hand, more outliers were sorted out from EC and TOC data, comparing with other water quality items. EC data did not show partly any variation for a long time at H station. If measured signal does not exceed ${\pm}0.001mS/cm$ from the sectional mean, the signal should be treated as normal data. Therefore, another routine was added to the data screening system, some data which were removed as outlier were restored.

Kaempferol의 MAPK 신호 조절을 통한 심근염 유발 엔테로바이러스 증식 억제 (Kaempferol Inhibits Enterovirus Proliferation through MAPK Signal Regulation)

  • 장진화;정해인;임병관;남상집
    • 생약학회지
    • /
    • 제48권3호
    • /
    • pp.173-178
    • /
    • 2017
  • We investigated the efficacy of single compound of plant extract in coxsackievirus B3 (CVB3) infection. CVB3 is a main cause of Hand-foot-mouth diseases (HFMD) and viral myocarditis in children and adult. Several single compounds of plant extract were purified by HPLC and tested as antiviral drug candidate. Among them, kaempferol was selected to effective anti-enterovirus compound by HeLa cells survival assay. CVB3 infected HeLa cells were treated with kaempferol ($100{\mu}g/ml-100ng/ml$) and their antiviral effect was confirmed. After 16 hours of treatment, HeLa cells were lysed and proteins were extracted for western blot analysis. CVB3 viral capsid protein VP1 production and transcription factor eIF4G-1 cleavage was significantly decreased in $100{\mu}g/ml$ kaempferol treatment. Virus replication was observed by virus RNA amplification. Kaempferol strongly reduced virus positive and negative strand RNA amplification. Moreover, MAPK signal induced by CVB3 infection, pERK and pmTOR, kaempferol treatment significantly inhibited the activity. Plant extract single compound, kaempferol, is a strong candidate to be developed non-toxic anti-enterovirus treatment agent.

빔형성방법을 이용한 회전하는 음원의 위치 판별에 관한 연구 (Localization of Rotating Sound Sources Using Beamforming Method)

  • 이재형;홍석호;최종수
    • 한국소음진동공학회논문집
    • /
    • 제14권12호
    • /
    • pp.1338-1346
    • /
    • 2004
  • The positions of rotating sound sources have been localized by experiments with the Doppler effects removed. In order to de-Dopplerize the sound signals emitted from moving sources, two kinds of signal reconstruction methods were applied. One is the forward propagation method and the other is the backward propagation method. Forward propagation method analyze the source emission time based on the instantaneous distance between sensors and the assumed source position, then the signals are reconstructed with respect to the emission time. On the other hand, the backward method uses time delay to do-Dopplerize the acquired data for the received time of reference. In both techniques. the reconstructed signal data were processed using beamforming algorithm to produce power distributions at the frequencies of interest. Experiments have been carried out for varying frequencies, rotating speeds and the object distances. It is shown that the forward propagation method gives better performance in locating source position than the backward propagation method.

Free Radical Toxicology and Cancer Chemoprevention

  • Lin, Jen-Kun
    • Toxicological Research
    • /
    • 제17권
    • /
    • pp.83-88
    • /
    • 2001
  • Most reactive oxygen species (ROS) are free radicals and implicated in the development of a number of disease processes including artherosclerosis, neurodegenerative disorders, aging and cancer. ROS are byproducts of a number of in vivo metabolic processes and are formed deliberately as part of nor-mal inflammatory response. On the other hand, ROS are generated either as by products of oxygen reduction during xenobiotic metabolism or are liberated as the result of the futile redox cycling of the chemical agents including several chemical carcinogens. A better understanding of the mechanisms of free radical toxicity may yield valuable clue to risks associated with chemical exposures that leading to the development of chronic diseases including cancer. The molecular biology of ROS-mediated alterations in gene expression, signal transduction and carcinognesis is one of the important subjects in free radical toxicology. Epidemiological studies suggest that high intake of vegetables and fruits are associated with the low incidence of human cancer. Many phytopolyphenols such as tea polyphenols, curcumin, resveratrol, apigenin, genistein and other flavonoids have been shown to be cancer chemopreventive agents. Most of these compounds are strong antioxidant and ROS scavengers in vitro and effective inducers of antioxidant enzymes such as superoxide dismutatse, catalase and glutathione peroxidase in vivo. Several cellular transducers namely receptor tyrosine kinase, protein kinase C, MAPK, PI3K, c-jun, c-fos, c-myc, NFkB, IkB kinase, iNOS, COX-2, Bcl-2, Bax, etc have been shown to be actively modulated by phyto-polyphenols. Recent development in free radical toxicology have provided strong basis for understanding the action mechanisms of cancer chemoprevention.

  • PDF

다중 안테나를 사용하는 3GPP LTE-Advanced 시스템의 성능향상을 위한 새로운 연판정 값 생성방식 (Novel Soft Decision Generation Technique for Performance Improvement of 3GPP LTE-Advanced Systems with Multiple Antennas)

  • 박재영;김재권
    • 한국산학기술학회논문지
    • /
    • 제15권11호
    • /
    • pp.6838-6844
    • /
    • 2014
  • LTE-A 시스템은 고속 데이터 전송을 위해 다중안테나를 장착하고 있다. 일반적으로 공간다중화 다중안테나 시스템의 수신기 복잡도는 후보벡터의 개수에 따라 증가한다. 후보벡터의 개수가 증가함에 따라 연판정 값의 신뢰도가 향상된다. 많은 수의 후보벡터를 생성하는 최우도 신호검출방식을 사용하면 우수한 성능을 달성할 수 있다. 반면 적은 개수의 후보벡터를 생성하는 저복잡도 수신기는 신뢰도가 낮은 연판정 값을 생성한다. 본 논문에서는 적은 수의 후보벡터를 사용해서 얻게되는 연판정 값의 신뢰도를 향상시키는 새로운 기술을 제안하고 모의실험을 통해 개선된 성능을 확인한다.

Apparatus for determining the angular position, speed and/or direction of rotary objects

  • Lim, J.T.;Choi, D.H.;Lee, H.J.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1986년도 한국자동제어학술회의논문집; 한국과학기술대학, 충남; 17-18 Oct. 1986
    • /
    • pp.596-600
    • /
    • 1986
  • This paper describes a capacitively reading apparatus for determining the angular orientation, speed and/or direction of rotary objects such as shaft, dial hand, counter wheel and the like. The apparatus consists of sensing device and circuit accompanying with said sensing device. The sensing device is provided by arranging many stationary electrodes lying substantially on a surface of a stationary plane member and by arranging rotary electrode lying substantially on a surface of rotary objects to be monitored, in which said rotary electrode is in confronting relationship to some stationary electrodes so as to construct unique capacitors according to the angular position of rotary objects. The angular position of said rotary electrode is determined by sets of stationary electrodes which are in confronting relationship to rotary electrode. A carrier signal is generated by scanning device while scanning said stationarelectrodes, whose periods are in corresponding relationship to said stationary electrodes, respectively. The periods of carrier corresponding to the angular position of said rotary electrode is modulated by a modulation signal generated by detecting device according to said rotary electrode. This apparatus is applied to automatically monitor any kind of storage tank, as well as to automatically read the conventional utility meters such as Watthour meters, Gas meters, Water meters, etc..

  • PDF

RF 수신부를 내장한 GPS 안테나 시스템의 설계 및 제작 (Design and fabrication of the GPS antenna system including RF-stage)

  • 홍성일;이정호;변건식;정만영
    • 전자공학회논문지A
    • /
    • 제33A권6호
    • /
    • pp.99-107
    • /
    • 1996
  • When GPS (global positioning system) is used as synchronous signal in CDMA digital cellular base station system and high speed digital synchronous communication network, antenna cable length is increased, comparing with other GPS application such as positioning or car navigation. In this paper, it is proposed that a type of new GPS antenna system including RF stage for reduction of cable loss in case of long cable.The antenna system with TMPA(truncated-corners microstrip patch antenna) is designed and fabricated because GPS signal has RHCP (right-hand circular polarization), consequently antenna size can be made small size. LNA (low noise amplifier) is designed by using HEMT(high electron mobility transistor)which has lower noise figurae and better AGC characteristics at low voltage than GaAs FET, and we equiped mixer, in GPS antenna unit, which converts from 1575.42MHz to 75.42MHz. As result of comparing between typical system and proposed system when cable length is 60m, 63dB, 55dB and 25dB gain are obtained for RG-316/U, RG-58C/U and RG-213/U, and better characteristics are achieved than typical system as far as cable length is longer.

  • PDF

Identification of nonlinear elastic structures using empirical mode decomposition and nonlinear normal modes

  • Poon, C.W.;Chang, C.C.
    • Smart Structures and Systems
    • /
    • 제3권4호
    • /
    • pp.423-437
    • /
    • 2007
  • The empirical mode decomposition (EMD) method is well-known for its ability to decompose a multi-component signal into a set of intrinsic mode functions (IMFs). The method uses a sifting process in which local extrema of a signal are identified and followed by a spline fitting approximation for decomposition. This method provides an effective and robust approach for decomposing nonlinear and non-stationary signals. On the other hand, the IMF components do not automatically guarantee a well-defined physical meaning hence it is necessary to validate the IMF components carefully prior to any further processing and interpretation. In this paper, an attempt to use the EMD method to identify properties of nonlinear elastic multi-degree-of-freedom structures is explored. It is first shown that the IMF components of the displacement and velocity responses of a nonlinear elastic structure are numerically close to the nonlinear normal mode (NNM) responses obtained from two-dimensional invariant manifolds. The IMF components can then be used in the context of the NNM method to estimate the properties of the nonlinear elastic structure. A two-degree-of-freedom shear-beam building model is used as an example to illustrate the proposed technique. Numerical results show that combining the EMD and the NNM method provides a possible means for obtaining nonlinear properties in a structure.

신경회로망을 이용한 전동기의 고장 부분 탐지 (Failure Detection of Motors using Artifical Neural Networks)

  • 이권현;강희조
    • 한국통신학회논문지
    • /
    • 제17권1호
    • /
    • pp.47-57
    • /
    • 1992
  • 전동기 회전시 발생되는 소음이 전동기 구조상의 소손부분 및 정도에 따라 서로 다른 소음의 특징을 갖는다는 점을 고려하여 신경회로망을 이용한 시그널(소음)인식 시스템으로써 전동기의 고장부분 탐지에 적용하였다. 적용된 신경회로망은 역전파(back-propagation)알고리즘을 써서 학습하였고 2개의 은역층을 갖는 4단 신경회로망으로 구성 되었다. 실혐 결과 전동기의 구조와 출력이 거의 일치하는 경우에는 고정 부분에 대한 항상 바른 판정을 내릴 수 있었으나 출력은 유사하더라도 전동기의 구조가 상이한 경우나 전동기 제작회사가 다른 경우에는 부정확한 판정으로 나타난다.

  • PDF

천연가스 계량설비에서 발생하는 유량 헌팅 현상 원인 분석 (An Investigation of the Major Factors Relating to the Flow Fluctuation at a Natural Gas Metering Facility)

  • 안승희;허재영;정종태;신창훈
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2005년도 연구개발 발표회 논문집
    • /
    • pp.158-165
    • /
    • 2005
  • KOGAS(Korea Gas Corporation) has about a hundred of local stations to supply natural gas to the city gas companies and the power stations. As some severe flow fluctuation phenomena are observed in several governor stations, the investigation about the reasons and factors which are relating to flow fluctuation has been started. Some field surveys hav been carried out and experimental studies have been performed to find the fluctuation mechanism. As a result, it is found that the flow fluctuation is related with the length of straight pipe in front of the meter, the size of the header pipe and the variation of demand at the city gas company and the power station. Furthermore. it is also proved that both the length of the transmitter cable and the status of the coating of signal transmission cable do not affect flow fluctuation, but the measurement range of the differential pressure transmitter influences flow fluctuation. On the other hand, as the averaging the flow fluctuation is converged to less than 0.1 % in almost all of the cases, it is concluded that the quantity of flow fluctuation do not relates to metering accuracy directly.

  • PDF