• Title/Summary/Keyword: Hand Device

Search Result 779, Processing Time 0.027 seconds

Improving Device-to-Device Connectivity with Responsive Web Technology

  • Park, Minsoo
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.14 no.1
    • /
    • pp.25-30
    • /
    • 2022
  • Since Tim Berners-Lee introduced the idea of the web to the world in the late 1980s, the way information is produced, accessed and used has been constantly changing. This was once again an era of upheaval after Apple's Steve Jobs introduced the smartphone to the world in the mid-2000s. Before the advent of smart devices, web browsing was mainly done using desktops. After the advent of this device, the era of solving almost all human needs with a small PC in the palm of your hand has arrived. The necessity of seamless connectivity between devices, which are constantly emerging and evolving, asks our attention more than ever. In this study, we will discuss a case of design and development of a national open access website, which is optimized for dynamic online user behaviors with diverse devices. Our goal is to provide one true web for people to use in their environment. Device makers need to provide products identical to the desktop environment as much as possible. Service providers should also provide services optimized for each device in hyper-connected environments. Providing a web, optimized for user's online context, will eventually result in a sustainable user experience.

A Handheld 3-Dimensional Motion Tracking Device for Ubiquitous Computing Environment (유비쿼터스 환경에서 사용 가능한 핸드 헬드형 3차원 움직임 추적장치)

  • Park, Myung-Kwan;Lee, Sang-Hoon;Suh, Il-Hong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.11 no.12
    • /
    • pp.1045-1050
    • /
    • 2005
  • This paper describes a design experience of a low-cost 6 DOF spatial tracker system where relative low accuracy and relatively long ranges, wireless communication will be achieved by means of low cost accelerometers and gyros with contemporary microprocessor. However, there are two key problems; one is the bias drift problem and the other is that single or double integration of acceleration signal suffers not only from noise but also from nonlinear effects caused by gravity. To be specific, beginning and stopping of hand motions needs to be accurately detected to initiate and terminate integration process to get position and pose of the hand from accelerometer and gyro signals, since errors due to noise and/or hand-shaking motions accumulated by integration processes. Several experimental results are shown to validate our proposed algorithms.

Ortho-Phonics Alpabetic One Hand Strock Keyboad's Structure and Design for Intergation of Language and Scription (어문결합을 지향하는 정음한손자판의 배치와 설계)

  • Kim Yong-Gi;Chin Yong-Ohk
    • The KIPS Transactions:PartB
    • /
    • v.11B no.7 s.96
    • /
    • pp.861-866
    • /
    • 2004
  • Keyboard is a link between human and terminal, so we can input knowledge to information device. The misstyping is occured or the speed is reduced if there would be transmission error. We always have to consider human interface and behavior effect, because the keyboard system is the harmony of human and machine. This paper is designed for representation of ortho-phonics alpabetic one hand strock keyboard which is enable to correct error and to edit word.

Calibration of Glove-Like Hand Input System for Wearable Computer (웨어러블 컴퓨터용 장갑형 손동작 입력 시스템의 보정)

  • 박용수;이상헌;백윤수
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.7
    • /
    • pp.209-216
    • /
    • 2000
  • Recently, Wearable Computers have been applied to medical equipments, inspection system, military and various fields of industries. To support the various application of wearable computer, many researches into the input device for wearable computer have been executed. This paper describes the glove-like hand input system for wearable computer. the characteristics of sensed values, and coupling effects between each sensor. Using these characteristics and coupling effects, the general relation between flexion angles of joints and the values from sensors are proposed as exponential functions. Also, the error range of sensed values is proposed and the glove-like hand input system is calibrated as well by the experiments.

  • PDF

On-line dynamic hand gesture recognition system for the korean sign language (KSL) (한글 수화용 동적 손 제스처의 실시간 인식 시스템의 구현에 관한 연구)

  • Kim, Jong-Sung;Lee, Chan-Su;Jang, Won;Bien, Zeungnam
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.34C no.2
    • /
    • pp.61-70
    • /
    • 1997
  • Human-hand gestures have been used a means of communication among people for a long time, being interpreted as streams of tokens for a language. The signed language is a method of communication for hearing impaired person. Articulated gestures and postures of hands and fingers are commonly used for the signed language. This paper presents a system which recognizes the korean sign language (KSL) and translates the recognition results into a normal korean text and sound. A pair of data-gloves are used a sthe sensing device for detecting motions of hands and fingers. In this paper, we propose a dynamic gesture recognition mehtod by employing a fuzzy feature analysis method for efficient classification of hand motions, and applying a fuzzy min-max neural network to on-line pattern recognition.

  • PDF

Study on User Interface for a Capacitive-Sensor Based Smart Device

  • Jung, Sun-IL;Kim, Young-Chul
    • Smart Media Journal
    • /
    • v.8 no.3
    • /
    • pp.47-52
    • /
    • 2019
  • In this paper, we designed HW / SW interfaces for processing the signals of capacitive sensors like Electric Potential Sensor (EPS) to detect the surrounding electric field disturbance as feature signals in motion recognition systems. We implemented a smart light control system with those interfaces. In the system, the on/off switch and brightness adjustment are controlled by hand gestures using the designed and fabricated interface circuits. PWM (Pulse Width Modulation) signals of the controller with a driver IC are used to drive the LED and to control the brightness and on/off operation. Using the hand-gesture signals obtained through EPS sensors and the interface HW/SW, we can not only construct a gesture instructing system but also accomplish the faster recognition speed by developing dedicated interface hardware including control circuitry. Finally, using the proposed hand-gesture recognition and signal processing methods, the light control module was also designed and implemented. The experimental result shows that the smart light control system can control the LED module properly by accurate motion detection and gesture classification.

The flip-flap puzzle flap: Another recycling option

  • Gandolfi, Silvia;Carloni, Raphael;Gilleron, Matthieu;Bonmarchand, Albane;Auquit-Auckbur, Isabelle
    • Archives of Plastic Surgery
    • /
    • v.46 no.2
    • /
    • pp.176-180
    • /
    • 2019
  • Post-traumatic soft tissue defects sometimes require sequential flap coverage to achieve complete healing. In the era of propeller flaps, which were developed to reduce donor site morbidity, Feng et al. introduced the concept of the free-style puzzle flap, in which a previously harvested flap becomes its own donor site by recycling the perforator. However, when a perforator cannot be found with a Doppler device, we suggest performing a new type of flap, the flip-flap puzzle flap, which combines two concepts: the free-style puzzle flap and the flip-flap flap described by Voche et al. in the 1990s. We present the cases of three patients who achieved complete healing through this procedure.

Implementation of Cost-effective Common Path Spectral Domain Free-hand Scanning OCT System

  • Shoujing Guo;Xuan Liu;Jin U. Kang
    • Current Optics and Photonics
    • /
    • v.7 no.2
    • /
    • pp.176-182
    • /
    • 2023
  • Optical coherence tomography (OCT) is being developed to guide various ophthalmic surgical procedures. However, the high cost of the intraoperative OCT system limits its availability mostly to the largest hospitals and healthcare systems. In this paper, we present a design and evaluation of a low-cost intraoperative common-path free-hand scanning OCT system. The lensed fiber imaging probe is designed and fabricated for intraocular use and the free-hand scanning algorithm that could operate at a low scanning speed was developed. Since the system operates at low frequencies, the cost of the overall system is significantly lower than other commercial intraoperative OCT systems. The assembled system is characterized and shows that it meets the design specifications. The handheld OCT imaging probe is tested on multilayer tape phantom and ex-vivo porcine eyes. The results show that the system could be used as an intraoperative intraocular OCT imaging device.