• Title/Summary/Keyword: Han River tributaries

Search Result 100, Processing Time 0.026 seconds

Analyses of Seasonal Water Quality of The Anyang Stream (안양천의 계절별 수질분석)

  • Han, Jung-Geun;Lee, Yang-Kyu;Nam, Jung-Man
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.7 no.4
    • /
    • pp.52-60
    • /
    • 2004
  • In order to analysis of the water pollution of the Anyang stream(one of the biggest branch streams of the Han River) and its main tributaries, the geological and topographical and rainfall features in its basin were investigated. To do this, the water samples were collected 23 points of the upper, mid and down of Anyang stream and its tributaries and were analyzed based on the chemical methods, Korean Biotic Index(KBI) and Saprobien systems. The Anyang stream basin has a characteristic of topographical torrential heavy rainfall like a typical rainfall feature in Korea. The concentration and the outflow rate of rainfall is very different in seasonal, and water pollution in dry season is especially severe. After 1997, although the water quality status of stream has been improved gradually, the concentration of T-N and SS at the upstream is increased due to the deficiency of facility used for collecting wastewater released from industrial factories, livestock farms and residential areas. The mainstream of the Anyang stream is classified into the 5th grade water as polysaprobic water area according to Saprobien system and the biotic index is over 2.5 in overall. Most of tributaries have 1~3 grade water limit with ${\alpha}$- and ${\beta}$-mesosaprobic except the upper and mid streams of Samsung tributary, in which pollution status is the lowest part. Though Sambong tributary is ${\alpha}$-mesosaproboic, biotic index is low because of the appearance of abundant benthos animals in farming and fishing villages.

Study on the Improvement of Water Quality by the strengthening of T-P effluent standard for Environmental Facilities in Paldang Basin (환경기초시설의 인 기준 강화에 따른 팔당호 유입 수계의 수질개선 효과분석)

  • Jeong, Won-Gu;Han, Young-Han;Rim, Jay-Myung
    • Journal of Industrial Technology
    • /
    • v.30 no.B
    • /
    • pp.125-135
    • /
    • 2010
  • The influences on water quality of each river by effluents from environmental facilities $located^{*}$ in 14 unit watersheds of North- and South-Han River, and Gyungan-cheon were analyzed. Also, the water quality modeling for study area was carried out to analyze the improvement effect of water quality by the strengthening of T-P effluent standard of environmental facilities. For the calibration and verification of model, water quality data and effluent loading calculated for 2006 were used. Data of low water period were used for calibration, and normal water period for verification. The results of calibration and verification were well matched with the real water quality dataset of revers. Also, the validity of the results were estimated using RI (Reliability Index) method. When the T-P effluent standards for environmental facilities were strengthened, T-P concentrations were predicted to improve from $0.025mg/{\ell}$ to $0.023mg/{\ell}$ in the outlet location of North-Han River, from $0.056mg/{\ell}$ to $0.040mg/{\ell}$ for South-Han River,and from $0.233mg/{\ell}$ to $0.146mg/{\ell}$ for Gyungan-cheon. Also, the T-P concentrations of tributaries including Jojong-cheon, Dal-cheong, Sumgang, Chungmi-cheon, Bokha-cheon, Heuk-cheon, and Wonju-cheon were predicted to improve from $0.063mg/{\ell}$ to $0.010mg/{\ell}$, from $0.091mg/{\ell}$ to $0.053mg/{\ell}$, from $0.199mg/{\ell}$ to $0.100mg/{\ell}$, from $0.168mg/{\ell}$ to $0.148mg/{\ell}$, from $0.186mg/{\ell}$ to $0.105mg/{\ell}$, from $0.019mg/{\ell}$ to $0.013mg/{\ell}$, and from $0.822mg/{\ell}$ to $0.236mg/{\ell}$, respectively.

  • PDF

A Study on the Impact of Landfill Leachate on the Water Environment - A case study of Nanji landfill - (매립지 침출수가 수환경에 미치는 영향에 관한 연구 - 난지도 매립지 사례를 중심으로-)

  • Park, Seok Soon;Park, Jae Woo;Jeong, Mi Hoon;Lee, Ji Mi;Cho, Kyung Sook;Yi, Seung Mook
    • Journal of Environmental Impact Assessment
    • /
    • v.8 no.2
    • /
    • pp.9-20
    • /
    • 1999
  • Until 1993, Nanji landfill has been the main solid waste treatment facility for Seoul, which is the capital of Korea. Since the landfill has not been properly lined, soil and ground water around the landfill has been contaminated. Due to the proximity, it has been speculated that the water quality of the Han River would have been also influenced by the leachate. In order to illuminate this, HELP model to estimate the quantity of the leachate from Nanji landfill and RMA model to simulate the change of water quality in Han River were applied in this research. The result indicates that the quantity of leachate from Nanji landfill has been overestimated by previous works and it was due to the failure to consider the water storage capacity of the landfill. The effect from Nanji landfill leachate on the water quality, in terms of COD input, proves to be smaller than those from other tributaries and influents to the River and the effect is larger when the flow of the River is reversed due to the tide.

  • PDF

Distribution of BOD Decay Rate in Streams and Reservoirs (국내 수계에서의 BOD분해속도계수 분포)

  • Jang, Changwon;Kim, Donghwan;Lee, Jaeyong;Kim, Yeonju;Jung, Sungmin;Shin, Changmin;Kim, Bomchul
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.2
    • /
    • pp.178-184
    • /
    • 2012
  • BOD decay rate is a key parameter of BOD-DO models in streams and lakes. In the calibration of water quality modeling appropriate range of coefficient is required for guidance of parameter selection. In this study BOD decay rate was measured at 48 stream sites and 10 reservoir sites in 8 different river systems. The decay rate ranged from 0.09 to 0.25 $day^{-1}$ with a mean of 0.16 $day^{-1}$. Among river systems the decay rates showed significantly different ranges, with the Han River system showing higher values than other river systems. In comparing different types of water bodies, the decay rate was slightly higher in tributaries than in reservoirs and mainstreams. Our results can provide guidance to the selection of proper coefficient for various water bodies in the calibration of water quality models.

Water Quality Forecasting System by Reliability Analysis in the Nakdong River (낙동강에서의 신뢰도해석에 의한 수질예보시스템의 개발)

  • Han, Geon-Yeon;Kim, Sang-Ho
    • Journal of Korea Water Resources Association
    • /
    • v.30 no.4
    • /
    • pp.411-420
    • /
    • 1997
  • QUAL2E-AFOSM model is developed to forecast the water quality by reliability analysis in the Nakdong River. A varied-flow analysis is performed for the reach of Waegwan to Mulgeum to estimate hydraulic parameters. An optimization technique by BFGS method is applied to determine the optimum reaction parameters and calibrations and verifications are performed based on these parameters. A reliability analysis for the stochastic analysis in a river is studied using the AFOSM method. The variations of water quality and discharge in the headwater, tributaries, and reaction coefficients are considered. Risks of violating existing water quality standards at several loactions in the Nakdong River are computed by using the QUAL2E-AFOSM method. The computed results computed by QUAL2E-AFOSM model agree with those of the Monte-Carlo method in QUAL2EU model.

  • PDF

Spatio-Temporal Dynamics of Estuarine Wetlands Related to Watershed Characteristics in the Han River Estuary (유역특성에 따른 한강하구 습지의 공간분포 및 변화분석)

  • Rho, Paik-Ho
    • Journal of the Korean Geographical Society
    • /
    • v.42 no.3 s.120
    • /
    • pp.344-354
    • /
    • 2007
  • Estuarine wetlands for 33 watersheds in the Han River estuary were delineated on topographic maps from the 1910s, 1970s, and 2000s. Then, these data were used to address the issue of spatial distribution and temporal variation. Watershed characteristics such as drainage density, location, watershed size, slope, and elevation were identified for each watershed to determine the relationship between watershed characteristics and spatial distribution of estuarine wetlands. The analysis of estuarine wetlands indicated that wetlands in the estuary had declined gradually between the 1910s and the 1970s, although most wetlands were lost since the 1970s mainly caused by the large development projects related to urban expansion in metropolitan Seoul. The sediment composition and formation processes of the wetlands differed with watershed location; mud flats dominate in the lower part of the estuary, and relatively more sandy and emergent-plant wetlands occur near the main channel and tributaries of the Han River. Relatively more estuary wetlands occur in large watersheds, which have high slopes and low elevations. Estuarine wetlands have been lost dramatically in the densely populated watershed regions (i.e., Han River Seoul, Han River Goyang, West Han River), while relatively more wetlands have remained in undeveloped regions, including the Lower Imjin River and Lower Han River. In particular, anthropogenic disturbance has played an important role in the loss of wetland through the conversion of wetland into agricultural and developed land.

Impact Analysis of Tributaries and Simulation of Water Pollution Accident Scenarios in the Water Source Section of Han River Using 3-D Hydrodynamic Model (3차원 수리모델을 이용한 한강 상수원구간 지류영향 분석 및 수질오염사고 시나리오 모의)

  • Kim, Eunjung;Park, Changmin;Na, Mijeong;Park, Hyeon;Kim, Bogsoon
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.4
    • /
    • pp.363-374
    • /
    • 2018
  • The Han River serves as an important water resource for the city of Seoul, Korea and in the neighboring metropolitan areas. From the Paldang dam to the Jamsil submerged weir, the 4 water intake stations that are located for the Seoul metropolitan population were under review in this study. Therefore the water quality management in this section is very important to monitor, analyze and review to rule out any safety concerns. In this study, a 3-D hydrodynamic model, EFDC (Environmental Fluid Dynamics Code), was applied to the downstream of the Paldang Dam in the Han River, which is about 23 km in length, to determine issues related to water resource management. The 3-D grid was composed of 2,168 horizontal grids and three vertical layers. In this case, the hydrodynamic model was calibrated and verified with an observed average daily water surface elevation, water temperature and flow rate data for 3 years (2013~2015). The developed EFDC model proved to reproduce the hydrodynamics of the Han River well. The composition ratios of the noted incoming flows at the monitored intake stations for 3 years and their flow patterns in the river were analyzed using the validated model. It was found that the flow of the Wangsuk Stream depended on the Paldnag dam discharge, and it was noted that the composition ratios of the stream at the intake stations changed accordingly. In a word, the Wangsuk Stream moved mainly along the right bank of the Han River under the condition of a normal dam flow. As can be seen, when the dam discharge rate was low, the incidence of lateral mixing was often seen. The scenario analyses were also conducted to predict the transport of conservative pollutants as in the case of a chemical spill accident. Generally speaking, when scenarios were applied, the arrival time and concentration of pollutants at each intake station was thus predicted.

-A Study on a Mathematical Model for Water Quality Prediction for Rivers- (하천(河川)의 수질예측(水質豫測)을 위한 수치모형(數値模型)에 관한 연구(硏究))

  • Kim, Sung-Soon;Lee, Yang-Kyoo;Kim, Gap-Jin
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.9 no.4
    • /
    • pp.73-86
    • /
    • 1995
  • The propriety of the numerical model application was examined on Paldang resevoir and its inflow tributaries located in the center of the Korean peninsula and the long term water quality forecast of the oxygen profile was carried out in this syduy. The input data of the model was the capacity of the reservoir, catchment area, percolation, diffusion rate, vertical mixing rate, dissolution rate from the bottom of the reservoir, outflow of the resevoir, water quality measurement and meteorology data of the drainage basin, and the output result was the annual estimation value of the dissolved oxygen concentration and the biochemical oxygen demand. The modeling method is based on the measured or calculated boundary condition dividing the water area into several blocks from the macorscopic aspect and considering the mass balance in these blocks. As the result of the water quality forecast, it was expected that the water quality in Northern Han River and Paldang reservoir would maintain the recent level, but that the water quality in the Southern Han River and its inflow tributary would worsen below the grade 4 of the life environmental standard from around 2000 owing to the decrease of DO concentration and the increase of BOD concentration.

  • PDF

Artificial Neural Networks for Flood Forecasting Using Partial Mutual Information-Based Input Selection

  • Jae Gyeong Lee;Li Li;Kyung Soo Jun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.363-363
    • /
    • 2023
  • Artificial Neural Networks (ANN) is a powerful tool for addressing various practical problems and it has been extensively applied in areas of water resources. In this study, Artificial Neural Networks (ANNs) were developed for flood forecasting at specific locations on the Han River. The Partial Mutual Information (PMI) technique was used to select input variables for ANNs that are neither over-specified nor under-specified while adequately describing the underlying input-output relationships. Historical observations including discharges at the Paldang Dam, flows from tributaries, water levels at the Paldang Bridge, Banpo Bridge, Hangang Bridge, and Junryu gauge station, and time derivatives of the observed water levels were considered as input candidates. Lagged variables from current time t to the previous five hours were assumed to be sufficient in this study. A three-layer neural network with one hidden layer was used and the neural network was optimized by selecting the optimal number of hidden neurons given the selected inputs. Given an ANN architecture, the weights and biases of the network were determined in the model training. The use of PMI-based input variable selection and optimized ANNs for different sites were proven to successfully predict water levels during flood periods.

  • PDF

Evaluation on Pollution Load Characteristics and Influence of Tributaries in the Hwangguji Stream (황구지천 유역의 오염부하 특성 및 지류 영향 평가)

  • Lim, Su-Jin;Lim, Byung-Ran;Lee, Han-Saem;Kang, Joo-Hyoung;Ahn, Tae-Ung;Shin, Hyun-Sang
    • Journal of Korean Society on Water Environment
    • /
    • v.37 no.4
    • /
    • pp.249-262
    • /
    • 2021
  • This study investigated the pollution characteristics of the main pollution zone in the Hwangguji watershed and the influence of the tributary on the main stream. The characteristics of the main pollution zone, including, the water quality index (WQI), stream rating, load duration curve (LDC), delivery load density (DLD), and contribution of the tributary to the mainstream, were evaluated by time-series visual heatmap. The WQI of the mainstream of Hwangguji was lowered to the poor (IV) level from the inflow point of Suwon stream (SW) and the LDC excess rate in the T-P was higher than that of BOD5, especially for the wet season, suggesting that management of non-point source with T-P is preferred. The contribution (%) of the tributaries in the upstream section of Hwangguji watershed were BOD5 14.54%, TOC 15.67%, T-N 5.43%, and T-P 6.97%. In particular, the Suwon sewage treatment plant located in the mainstream showed a high contribution of BOD5 (64.40%) and T-P (53.54%), respectively, due to the high discharge rate (6.019 m3/sec). Meanwhile, Sammi and Gal stream have a large impact on the mainstream with high DLD and poor WQI. Thus, both streams were considered as pollution hot spots. These results provide useful basic data for preparing more effective water quality improvement and management plans in the watershed.