• Title/Summary/Keyword: Hamstring Tendon

Search Result 76, Processing Time 0.028 seconds

Revision Anterior Cruciate Ligament Surgery Using Hamstring Autograft (슬괵건을 이용한 전방 십자 인대 재 재건술)

  • In Yong;Bahk Won-Jong;Kwon Oh-Soo;Suh Young-Wan;Im Dong-Sun
    • Journal of the Korean Arthroscopy Society
    • /
    • v.7 no.2
    • /
    • pp.183-188
    • /
    • 2003
  • Purpose : The purpose of this study is to evaluate the results of revision surgery for failed anterior cruciate ligament (ACL) reconstruction using quadruple hamstring tendon autograft. Materials and Methods : From May 2000 to July 2002, six patients received ACL revision surgery using quadruple hamstring autograft for failed ACL reconstruction. Femoral tunnels were made 40 mm in depth and fixed with a cross pin and a bioabsorbable interference screw to fill the bone defect. In tibial tunnels, the grafts were fixed with Intrafix(Mitek, Norwood, MA). In case of tibial tunnel widening, additional screw-washer fixation was done. Follow up was at least 12 months postoperatively. Clinical assessments consisted of Lysholm knee scores, International Knee Documentation Committee(IKDC) evaluation form and manual maximal side to side difference using KT-2000 arthrometer. Results : The average Lysholm knee score improved from 77.2 preoperatively to 87.7 postoperatively. At the final IKDC evaluation, 1 case was graded as normal, 4 nearly normal, 1 abnormal. Mean side to side difference of manual maximum anterior displacement using the KT-2000 arthrometer was 1.8mm. The success rate was $83\%$. Conclusion : ACL revision surgery using quadruple hamstring autograft with double fixation is considered good procedure with successful results.

  • PDF

Pretibial Ganglion after Anterior Cruciate Ligament Reconstruction with Bioabsorbable Interference Screw fixation $(Bioscrew^{\circledR})$ - A Case Report - (생분해성 간섭나사를 이용한 전방 십자 인대 재건술 후 발생한 결절종 - 증례보고 -)

  • Song, Eun-Kyoo;Shim, Sang-Don;Kim, Myung-Sun
    • Journal of the Korean Arthroscopy Society
    • /
    • v.6 no.2
    • /
    • pp.188-191
    • /
    • 2002
  • The complication caused by a bioabsorbable interference screw composed of Poly-L-Lactic-Acid is rare after anterior cruciate ligament (ACL) reconstruction. We reported a case of a pretibial ganglion at the orifice of the tibial tunnel where the graft tendon had been fixed with a bioabsorbable interference screw $(Bioscrew^{\circledR})$ for ACL reconstruction using autogenous hamstring tendon. The patient was underwent ganglion excision and interference screw removal.

  • PDF

Sciatic Nerve Injury Following a Delayed Surgical Procedure for the Hamstring Muscle Avulsion from the Ischial Tuberosity - A Case Report - (슬근 좌골 결절 견열 손상의 지연 수술후 발생한 좌골신경 손상 - 증례 보고 -)

  • Kim Hui Taek;Yoo Chong Il;Yun Pyung Ju;Lee Jong Seo
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.1 no.1
    • /
    • pp.75-78
    • /
    • 2002
  • Avulsion of the hamstring tendon from the ischial tuberosity is common in many sports, especially with younger athletes. The injury results from a sudden forceful flexion of the hip joint when the knee is extended and the hamstring muscles powerfully contracted. Early diagnosis and surgical repair with reattachment of avulsed muscles to the ischial tuberosity restore function and correct deformity. But, a delay in the diagnosis and treatment leads to a poor result functionally and clinically. Complication, such as heterotopic ossification and failure of the fixation, etc., were reported following a surgical procedure for this injury. However, sciatic nerve injury has not been reported in the literature. We report our experience of a sciatic nerve palsy after surgery that was performed three months after that the initial injury.

  • PDF

What Has Been Learned in Anterior Cruciate Ligament Reconstruction during the Past 20 Years? (전방십자인대 재건수술은 지난 20년간 어떻게 발전하였나?)

  • Ro, Du Hyun;Han, Hyuk-Soo;Lee, Myung Chul
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.1
    • /
    • pp.1-13
    • /
    • 2021
  • Considerable progress on anterior cruciate ligament reconstruction surgery has been made over the past 20 years, and the results have improved significantly. An anatomical understanding of the anterior cruciate ligament has also changed, and the surgical technique has also changed accordingly. The double-bundle concept is still valid, but the ribbon-shaped anterior cruciate ligament concept, including direct fiber and indirect fiber, is gradually replacing it. The isometry point theory no longer exists, and various surgical methods, such as single-bundle anatomical reconstruction, double-bundle reconstruction, remnant preservation, and rectangular tunnel technique, are being performed. Regarding the graft, interest in the bone-patellar tendon-bone, patellar tendon, quadriceps tendon, and allogeneic tendon change over time, and this change is ongoing.

Dynamic Stabilization of the Scapula for Serratus Anterior Dysfunction: A Retrospective Study of Functional Outcome and Results

  • Chung, Soo Tai;Warner, Jon J.P.
    • Clinics in Shoulder and Elbow
    • /
    • v.18 no.4
    • /
    • pp.229-236
    • /
    • 2015
  • Background: Twenty-six patients (12 male and 14 female) with symptomatic scapular winging caused by serratus anterior dysfunction were managed by split pectoralis major tendon transfer (sternal head) with autogenous hamstring tendon augmentation from 1998 to 2006. Methods: Twenty-five patients showed positive results upon long thoracic nerve palsy on electromyography. The mean duration of symptoms until surgery was 48 months (range, 12-120 months). Four patients had non-traumatic etiologies and 22 patients had traumatic etiologies. On follow-up assessment for functional improvement, a Constant-Murley score was used. Twenty-one patients were completely evaluated, while five patients who had less than 12 months of follow-up were excluded. Results: Pain relief was achieved in 19 of the 21 patients, with 20 patients showing functional improvement. The pain scores improved from 6.0 preoperatively to 1.8 postoperatively. The mean active forward elevation improved from $108^{\circ}$ (range, $20^{\circ}-165^{\circ}$) preoperatively to $151^{\circ}$ (range, $125^{\circ}-170^{\circ}$) postoperatively. The mean Constant-Murley score improved from 57.7 (range, 21-86) preoperatively to 86.9 (range, 42-98) postoperatively. A recurrence developed in one patient. Of the 21 patients, ten had excellent results, six had good results, four had fair results, and one had poor results. Conclusions: Most patients with severe symptomatic scapular winging showed functional improvement and pain relief with resolution of scapular winging.

ACL Reconstruction with Hamstring Tendon and LA (Ligament anchor) Screw (슬괵건과 LA나사를 이용한 관절경적 전방 십자 인대 재건술)

  • Song Eun-Kyoo;Seon Jong-Keun;Cho Sang-Gwon
    • Journal of the Korean Arthroscopy Society
    • /
    • v.7 no.2
    • /
    • pp.189-195
    • /
    • 2003
  • Purpose : To evaluate the clinical results after anterior cruciate ligament (ACL) reconstruction with hamstring tendon and Ligament Anchor (LA) screw Materials and Methods : 103 patients (104 cases) who were followed up at least more than 2 years after ACL reconstruction were included in this study. The average period of follow-up was 36 months. The clinical results such as physical examination and Lysholm knee score and instrumented anterior laxity test with Telos were evaluated. Results : The Lysholm knee score was 57.9 in average preoeratively and improved to 95.2 in average at follow up. On the Lachman test, there were mild (+) instability in 46 cases $(45\%)$, moderate (++) in 33 $(31\%)$, severe (+++) in 25 $(24\%)$ preoperatively. 90 cases $(87\%)$ were converted to negative and 14 $(13\%)$ to mild at follow up. On Pivot-shift test, there were negative (-) instability in 22 cases $(22\%)$, mild (+) in 62 $(59\%)$, moderate (++) in 12 $(11\%)$ and severe in 8 $(8\%)$ preoperatively. 87 cases $(84\%)$ were converted to negative and 17 $(16\%)$ to mild at follow up. On instrumented anterior laxity test with $Telos^{\circledR}$, side to side difference on 20 lb was $13.4{\pm}5.6$ (7-25) mm in average preoperatively, and was decreased to $3.6{\pm}1.5$ (1-6) mm in average at follow-up. Complications were quadriceps muscle atrophy in 27 $(30.0\%)$, saphenous nerve paresthesia in 19 $(18.3\%)$, anterior knee crepitus in 13 $(12.5\%)$ and over-penetration of screw through lateral femoral cortex in 5 cases $(4.8\%)$. Conclusion : ACL reconstruction with hamstring tendon and LA screw was one of the choice of graft and fixatives in restoring knee stability and in improving clinical results with little complications such as anterior knee pain.

  • PDF

ACL reconstruction with autologous hamstring tendon - Short term clinical result using new femoral suspensory fixation device 'Cross Pin' and graft tensioner for maintaining a constant tension- (자가 슬괵건을 이용한 전방 십자 인대 재건술 - 새로운 대퇴부 현수고정법인 Cross Pin과 일정한 긴장력 유지를 위한 Graft Tensioner 사용의 단기 추시 결과 -)

  • Seo, Seung-Suk;Kim, Chang-Wan;Kim, Jin-Seok;Choi, Sang-Yeong
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.10 no.1
    • /
    • pp.27-34
    • /
    • 2011
  • Purpose: To evaluate the short term clinical result of ACL reconstruction with autologous hamstring tendon using Cross pin and Graft Tensioner and to seek way to resolve the experienced technical problems. Materials and Methods: From January 2008 to March 2009, 35 patients who had been treated arthroscopic ACL reconstruction were enrolled. The femoral side of ACL graft was fixed with Cross pin. The tibial side of graft was fixed with Intrafix and post-tie. The graft was tensioned with Graft Tensioner at 80N. We analyzed the clinical, radiographic results and complications. Results: IKDC subjective score and Lysholm score improved to 89.1 and 91.4 points. Also, Pivot shift test and One-leg hop test showed good results postoperatively. Side to side difference using KT-1000 arthrometer and Telos stress radiography improved compared with normal limb to $2.8{\pm}1.6$ mm and $2.6{\pm}1.3$ mm, respectively. The femoral tunnel enlarged to $2.3{\pm}1.1$ mm. Soft tissue irritation and femoral tunnel-graft harness length mismatch, femoral tunnel-cross pin tunnel mismatch were happened as peri-operative complications. Conclusion: Using of Cross pin and Graft Tensioner for ACL reconstruction with hamstring tendon is one of the good method for obtaining stability in short-term clinical result. But to reduce femoral tunnel-cross pin mismatch, it needs to shorten femoral bone tunnel and to create cross pin tunnel as vertical as possible. And to reduce femoral tunnel-graft harness mismatch, it needs to advance position rod further 3 mm when to create femoral tunnel.

  • PDF

Anterior Cruciate Ligament Double Bundle Reconstruction with Hamstring Tendon Autografts - Technical Notes (자가 슬괵건을 이용한 전방 십자 인대 이준 다발 재건술 - 수술 술기 -)

  • Ahn, Jin-Hwan;Lee, Sang-Hak;Ahn, Hyung-Kwon;Kang, Hong-Jae
    • Journal of the Korean Arthroscopy Society
    • /
    • v.9 no.2
    • /
    • pp.222-231
    • /
    • 2005
  • Purpose: This article describes a double-bundle ACL reconstruction technique using a five-strand hamstring tendon autograft with conventional anteromedial bundle reconstruction and additional posterolateral bundle reconstruction. Operative technique: For the tibial tunnel, the conventional single tunnel technique is performed and for the femoral tunnel, the double tunnel technique is performed with the anteromedial and posterolateral bundle. After minimal notchplasty, the anteromedial femoral tunnel is prepared with leaving one milimeter of posterior femoral cortex within the over-the-top, which if positioned at the 11-o'clock orientation for the right knee or at the 1-o'clock position for the left knee. The posterolateral femoral tunnel that is located 5 to 7 mm superior to the inner margin of the lateral meniscus anterior horn at $90^{\circ}$ of flexion is prepared with tile outside-in technique using a 4.5 cannulated reamer. The graft material for the double bundle reconstruction is made of the conventional four-strand hamstring autograft in the anteromedial bundle and of a single-strand semitendinosus tendon in the posterolateral bundle. The anteromedial bundle is fixed with using a rigid fix system on the femoral side and the posterolateral bundle is fixed to tie with the miniplate from the outside femur. Then, with the knee in $10^{\circ}\;to\;20^{\circ}$ of flexion, a bioabsorbable screw is simultaneously applied to achieve tibial fixation with tensioning of both bundles. Conclusion: A double bundle reconstruction with five-strand hamstring autograft, which is designed with a favorable conventional anteromedial bundle and an additional posterolateral bundle to restore rotation stability, seems to be a very effective method for the treatment for ACL instabilities.

  • PDF

Mid-term Results of Arthroscopic Anterior Cruciate Ligament Reconstruction using Autologous Bone-Patellar tendon-Bone versus Hamstring tendon (자가 골-슬개건-골과 슬괵건을 이용한 관절경적 전방 십자 인대 재건술의 중기 추시 결과)

  • Sim, J.A.;Kwak, J.H.;Lee, B.K.
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.5 no.1
    • /
    • pp.45-49
    • /
    • 2006
  • 목적: 자가 골-슬개건-골과 슬괵건을 이용한 전방 십자 인대 재건술의 5년 중기 추시 결과를 비교 분석하고자 한다. 대상 및 방법: 전방 십자 인대 재건술을 시행한 후 5년 이상 추시 관찰이 가능한 65예를 대상으로 하였고, 골-슬개건-골이 38예, 슬괵건이 27예였다. 술 후 평가는 Lysholm 점수, 관절 운동 범위, 대퇴부 중간 부위 둘레 길이, Lachman 검사, 축 이동 검사, KT 2000 관절 계측기를 시행하였고, 술 후 합병증을 평가하였다. 결과: Lysholm 점수는 골-슬개건-골군과 슬괵건국에서 각각 평균 91점, 94.2점으로 슬괵건군이 우수하였고, 대퇴부 중간 부위 둘레 길이는 건측에 비해 각각 평균 1.7cm, 1.3cm의 차이를 보였다. 양 군간에 관절 운동 범위, Lachman 검사, 축 이동 검사 및 KT 2000 관절 계측 결과는 통계적으로 유의한 차이가 없었으나, 술 후 합병증은 과도한 보행이나 운동 후 슬관절 동통이 골-슬개건-골군에서 7예, 슬괵건 군에서 4예 관찰되었고, 전방 슬관절 동통이 골-슬개건-골군에서 4예 관찰되어, 골-슬개건-골군에서 더 많이 발생하였다. 결론: 5년 중기 추시에서 자가 슬괵건군이 우수한 슬관절 기능, 적은 합병증 등 임상적으로 우수하였으나 장기 추시가 요할 것으로 사료된다.

  • PDF

Dynamic Stabilization of the Scapula for Serratus Anterior Dysfunction

  • Jeong, Su-Tae;Warner, Jon J.P.
    • The Academic Congress of Korean Shoulder and Elbow Society
    • /
    • 2008.03a
    • /
    • pp.53-53
    • /
    • 2008
  • Twenty-six patients (12 male and 14 female) with symptomatic scapular winging caused by serratus anterior dysfunction were managed with split pectoralis major tendon transfer (sternal head) with autogenous hamstring tendon augmentation from 1998 to 2006. Twenty-five patients had positive results for long thoracic nerve palsy on electromyography. The mean duration of symptoms until surgery was 48 months (range 12~120 months). Four patients had non-traumatic etiologies and twenty-two patients had traumatic etiologies. At the final follow-up assessment for functional improvement, a Constant-Murley score was used. 21 patients were completely evaluated, while 5 patients who had less than 12 months follow-up were excluded. Pain relief was achieved in 19 of the 21 patients, with twenty patients showing functional improvement. The pain scores improved from 6.0 preoperatively to 1.8 postoperatively. The mean active forward elevation improved from $108^{\circ}$ (range $20^{\circ}\sim165^{\circ}$) preoperatively to $151^{\circ}$ (range $125^{\circ}\sim170^{\circ}$) postoperatively. The mean Constant-Murley score improved from 57.7 (range 21~86) preoperatively to 86.9 (range 42~98) postoperatively. A recurrence developed in one patient. Of the twenty-one patients, eight had excellent results, nine had good results, three had fair results, and one had poor results. Most patients with severe symptomatic scapular winging had functional improvement and pain relief with resolution of scapular winging.

  • PDF