• Title/Summary/Keyword: Half-time

Search Result 2,591, Processing Time 0.028 seconds

Analysis of Half-life Time and Residual Concentration of Ethalfluralin Herbicide in Soils (토양 중 제초제 Ethalfluralin의 잔류 농도와 반감기 분석)

  • Han, Seong Soo;Rim, Yo Sup;Kim, Il Kwang
    • Analytical Science and Technology
    • /
    • v.10 no.3
    • /
    • pp.168-178
    • /
    • 1997
  • The optimum conditions for the residual analysis of the ethalfluralin herbicide on soils were investigated and the residues in soils were determined by gas chromatography with electron capture detector(GC-ECD). The soil samples extracted with methanol and dichloromethane and concentrated. The concentrated phase were redissolved with toluene and analyzed with GC-ECD after separated by cyanosilica gel Sep-Pak cartridge. From the standard addition experiments with 0.1 and 1.0ppm, the average recoveries were 92.8~101.2% and the detection limit was 0.004ppm. The half-life time of ethalfluralin in the soil(A) was 35 days in the laboratory and 7.2 days in the field test whereas it was 45 days and 9.7 days for each in case of soil(B).

  • PDF

Transient Heat Flux Evaluation of Underwear for Protective Clothing using Sweating Manikin (발한 마네킹을 이용한 보호복용 언더웨어의 동적(Transient) 열류량 평가)

  • Park, Hye-Jun;Kim, Hyun-Jung;Hong, Kyung-Hi
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.32 no.1
    • /
    • pp.157-165
    • /
    • 2008
  • Transient thermal response of five types of underwear(cotton jersey, wool jersey, nylon jersey, cotton mesh and polyester mesh) for a protective coverall is evaluated using a sweating thermal manikin. Experimental protocol for transient thermal response of the sweating thermal manikin was also proposed. As results, it was found that steady state thermal response from sweating thermal manikin was not sensitive enough to evaluate thermal comfort of the experimental garments. However, when half time is used as an index of the heat flux change in transient thermal response, difference was found among underwear materials. Half time of cotton was the shortest and heat transfer of cotton was the fastest followed by polyester mesh, cotton jersey, nylon jersey and wool jersey. Dynamic thermal response of wool underwear was quite different from that of cotton underwear. Wool shows quite less heat flow at the initial stage, however, moisture permeability of wool was higher than cotton at the later stage. It was difficult to distinguish surface temperature difference visually using thermogram taken right before the completion of dry and wet test in steady state thermal response.

Communication protocol for 1:N subscribers using half-duplex radio equipments based on CSMA/CA (CSMA/CA 기반 반이중 전송방식 무전기를 이용한 1:N 가입자간 통신 프로토콜)

  • Jang, Myung-Jin;Park, Seong-Jin
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.531-534
    • /
    • 2010
  • Currently the functionality of the PRC-999K radio that is widely used in Korean Army is half-duplex and the broadcasting system that all subscribers have to listen when one subscriber speaks in time. Radio data communication system configures peer-to-peer network between command post and network members in military fire control system. And the system applies CSMA/CA(Carrier Sense Multiple Access/Collision Avoidance) technique to avoid data collision. Such a data transmitting/receiving time could be reduced by allocating address in serial order to each network members. By doing that, command post need to broadcast data only one time and assigned members will reply in order without data collision. This paper provides such a protocol and algorithm.

  • PDF

Assessing the long-term durability and degradation of rocks under freezing-thawing cycles

  • Seyed Zanyar Seyed Mousavi;Mohammad Rezaei
    • Geomechanics and Engineering
    • /
    • v.34 no.1
    • /
    • pp.51-67
    • /
    • 2023
  • In this research, the degradation rate of physical properties of the Angouran pit bedrock (calc-schist) is first investigated under the specific numbers of freeze-thaw (F-T) cycles. Then, the durability of calc-schist specimens against the F-T cycle number (N) is examined considering the mechanical parameters, and using the decay function and half-time techniques. For this purpose, point load strength (IS(50)), second durability index (Id2), Brazilian tensile strength (BTS), and compressive (VP) and shear (VS) wave velocities of calc-schist specimens are measured after 0, 7, 15, 40, and 75 N. For comparing the degradation rate of mechanical properties of available rock types on the Angouran mine walls, these tests are also carried out on the limestone and amphibolite schist specimens beside the calc-schist. According to test results, the exponential regression models are developed between the mechanical parameters of rock specimen's and N variable. Also, the long-term durability of each rock type versus N is studied using the decay function and half-time techniques. Results indicated that the degradation rate differs for the above rock types in which amphibolite schist and calc-schist specimens have the highest and least resistance against the N, respectively. The obtained results from this study can play a key role in the optimal design of the mine's final walls.

A Study of Intonation Curve Slopes in Korean Spontaneous Speech (자유 발화 자료에서 나타나는 한국어 억양 곡선의 기울기 특성에 대한 연구)

  • Oh, Jeahyuk
    • Phonetics and Speech Sciences
    • /
    • v.6 no.1
    • /
    • pp.21-30
    • /
    • 2014
  • This study aims to discuss pitch slope on Korean intonation curve in spontaneous speech data. For this study, 656 utterances were taken in the spoken corpus and used 'close-copy stylization'. And then the physical feature of pitch movements was extracted for the study. The pitch slope was calculated on the basis of time and pitch range in each utterance. As a result, the average and distribution of pitch slope is similar between men and women in the range of the pitch movement except for essential differences. The slope of pitch movement confirms that there are no differences between men and women. Pitch slope on a scale of -10 to 10 is 90% of the entire pitch slope; pitch slope that moves by time scale without curve is 33.1%; pitch slope that moves half of the pitch bandwidth during the average time for pitch movement is 23.4%; pitch slope that moves 100% of pitch bandwidth during a half of the average time for pitch movement is 10.4%. Those results imply the possibility of standardization methods of Korean intonation by pitch slope.

A New Frequency Controlled Half-bridge Converter with Hold-up Time Extension Circuit

  • Kim, Duk-You;Kim, Jae-Kuk;Lee, Woo-Jin;Moon, Gun-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.382-384
    • /
    • 2008
  • Hold-up time is a special requirement for the front end DC/DC converter in a server power supply. It forces the converter with the variable switching frequency to operate in a wide switching frequency range, which makes the regulation difficult and reduces the power density. In this paper a novel frequency controlled half bridge converter with the hold-up time extension circuit is proposed. During the hold-up time, the auxiliary switches are turned on, thus the resonant inductance is reduced and the voltage conversion ratio is increased. Therefore, the output capacitor of the power factor correction (PFC) circuit can be decreased, and the converter can have high power density. The proposed converter is verified by experimental results from a prototype with 700W, 400V input, and 12V output.

  • PDF

Analytical solution of a two-dimensional thermoelastic problem subjected to laser pulse

  • Abbas, Ibrahim A.;Alzahrani, Faris S.
    • Steel and Composite Structures
    • /
    • v.21 no.4
    • /
    • pp.791-803
    • /
    • 2016
  • In this article, the problem of a two-dimensional thermoelastic half-space are studied using mathematical methods under the purview of the generalized thermoelastic theory with one relaxation time is studied. The surface of the half-space is taken to be thermally insulated and traction free. Accordingly, the variations of physical quantities due to by laser pulse given by the heat input. The nonhomogeneous governing equations have been written in the form of a vector-matrix differential equation, which is then solved by the eigenvalue approach. The analytical solutions are obtained for the temperature, the components of displacement and stresses. The resulting quantities are depicted graphically for different values of thermal relaxation time. The result provides a motivation to investigate the effect of the thermal relaxation time on the physical quantities.

Surface Modification of PET Fabrics Treated with Sputter Etching (Sputter etching 처리에 의한 PET직물의 표면개질)

  • Koo, Bon Sik;Kim, Yong Hae;Cho, Yeun Chung;Park, Ki Ho;Won, Eun Hee;Koo, Kang;Son, Tae Won
    • Textile Coloration and Finishing
    • /
    • v.9 no.2
    • /
    • pp.50-56
    • /
    • 1997
  • Poly(ethylene terephthalate) (PET) has been etched by sputtering in the presence of argon gas and the resulting surface modifications investigated via weight loss, time of water permeation, half value period, scanning electron microscope(SEM) and color difference measurements. According to increasing sputter etching time, weight loss increased, the time of water permeation and half value period of the sputter etched PET fabrics decreased. Color depth of fabrics increased by increasing sputter etching time. We investigated the fabric surface modification by SEM. Many microcraters on the fabric surface formed by the sputter etching resulted in increase of surface area of the fabric and wettability.

  • PDF

The dynamic response of the FGM coated half-plane with hysteretic damping under time harmonic loading

  • Xiao-Min Wang;Liao-Liang Ke;Yue-Sheng Wang
    • Structural Engineering and Mechanics
    • /
    • v.87 no.1
    • /
    • pp.95-106
    • /
    • 2023
  • This paper investigates the dynamic response of a functionally graded material (FGM) coated half-plane excited by distributed time harmonic loading. Three types of typical distributed surface loads, including uniform load, Hertz load, and square-root singular load, are considered. The mass density and elastic modulus of the FGM coating are supposed to be described by the exponential function. The material damping is modelled by a linearly hysteretic damping which is expressed by a complex modulus in the time harmonic motion. Using Fourier integral transform technique and numerical integral method, the effects of the excitation frequency, gradient index, damping, and load type on the dynamic stresses and displacements are discussed.

Power Factor Correction of Single-phase Boost Converter for Low-cost Type UPS Configuration (저 가격형 UPS를 구성하기 위한 단상 부스트 컨버터의 고 역률 제어)

  • Park, Jong-Chan;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.62 no.3
    • /
    • pp.145-150
    • /
    • 2013
  • A novel AC to DC PWM converters with unity input power factor are proposed to overcome the above shortcoming. The main function of these converters is to shape the input line current to force it exactly in phase with the input AC voltage. Therefore, the input power factor can be improved to near unity and the input current harmonics can be eliminated. In this paper, half-bridge converter with two active switches and two diodes are utilized for low-cost type UPS configuration. By having only two semiconductors in the current path at any time, losses can be reduced over the conventional boost topology. Also, this converter provides controllable dc-link voltage, high power factor, and low cost type converter by simple power circuits. Simulation results show that the proposed half-bridge converter/inverter control technique can be applied to single-phase low-cost type UPS systems successfully.