• 제목/요약/키워드: Half-Bridge

검색결과 685건 처리시간 0.023초

Copolymerization of Ethylene and Norbornene via Polymethylene Bridged Dinuclear Constrained Geometry Catalysts

  • Zhu, Yin-Bang;Jeong, Eung-Yeong;Lee, Bae-Wook;Kim, Bong-Shik;Noh, Seok-Kyun;Lyoo, Won-Seok;Lee, Dong-Ho;Kim, Yong-Man
    • Macromolecular Research
    • /
    • 제15권5호
    • /
    • pp.430-436
    • /
    • 2007
  • The dinuclear half-sandwich CGCs (constrained geometry catalyst) with a polymethylene bridge, $[Ti({\eta}^5 : {\eta}^1-indenyl)SiMe_2NCMe_3]_2(CH_2)_n]$[n = 6 (1) and 12 (2)], have been employed in the copolymerization of ethylene and norbornene (NBE). To compare the mononuclear metallocene catalysts; $Ti({\eta}^5 : {\eta}^1-2-hexylindenyl)SiMe_2NCMe_3$ (3), $(Cp^* SiMe_2NCMe_3)$Ti (Dow CGC) (4) and ansa-$Et(Ind)_2ZrCI_2$ (5), were also studied for the copolymerization of ethylene and NBE. It was found that the activity increased in the order: 1 < 2 < 3 < 5 < 4, indicating that the presence of the bridge between two the CGC units contributed to depressing the polymerization activity of the CGCs. This result strongly suggests that the implication of steric disturbance due to the presence of the bridge may playa significant role in slowing the activity. Dinuclear CGCs have been found to be very efficient for the incorporation of NBE onto the polyethylene backbone. The NBE contents in the copolymers formed ranged from 10 to 42%, depending on the polymerization conditions. Strong chemical shifts were observed at ${\delta}$42.0 and 47.8 of the isotactic alternating NBE sequences, NENEN, in the copolymers with high NBE contents. In addition, a resonance at 47.1 ppm for the sequences of the isolated NBE, EENEE, was observed in the $^{13}C-NMR$ spectra of the copolymers with low NBE contents. The absence of signals for isotactic dyad at 48.1 and 49.1 ppm illustrated there were no isotactic or microblock (NBE-NBE) sequences in the copolymers. This result indicated that the dinuclear CGCs were effective for making randomly distributed ethylene-NBE copolymers.

러버쉬팅변환을 통한 「동궐도(東闕圖)」의 평면도 제작 가능성 연구 - 창덕궁 금천교 주변을 중심으로 - (A Study on the Possibility of Producing a Floor Plan of 「Donggwoldo(東闕圖)」 through the Use of Rubber Sheeting Transformation - With a Focus on the Surroundings near the Geumcheongyo Bridge in Changdeokgung Palace -)

  • 이재용;김영모
    • 헤리티지:역사와 과학
    • /
    • 제50권4호
    • /
    • pp.104-121
    • /
    • 2017
  • 본고는 "동궐도(東闕圖)"의 작도원리를 기반으로 러버쉬팅변환(Rubber Sheeting Transformation)을 통해 조선후기 창덕궁 금천교 주변의 평면도 제작을 시도하였으며, 연구결과는 다음과 같다. 첫째, "동궐도(東闕圖)" 제작 당시부터 현존하는 주요 전각의 실제 크기와 그림에 묘사된 크기를 비교하여 전각의 정입면이 약 1/200으로 축소되어 작성되었음을 밝혀냈다. 그러나 측입면에서는 동일한 제작 비율이 확인되지 않았다. 다만, 측입면의 길이가 실제의 약 절반 정도로 그려지고, 사선 각도가 평균 $39^{\circ}$로 파악됨에 따라 캐비닛 투영(Cabinet Projection)과 유사한 방식으로 작도되었음을 확인하였다. 둘째, "동궐도(東闕圖)"의 작도 원리를 역추적하여 "사투영평면도"를 작성하고 러버쉬팅변환을 통해 "동궐도(東闕圖)"의 창덕궁금천교 주변 평면도를 제작하였다. 변환 시 투영변환(projective transformation)이 가장 적합한 것으로 확인되었고, 표준 오차는 2.1208m로 비교적 높은 정확도를 나타냄으로써 "동궐도(東闕圖)"의 평면도 제작이 유의미하였다. 이는 "동궐도(東闕圖)"뿐만 아니라 평행사선도법으로 작성된 각종 기록화의 평면도 제작 가능성을 시사한다. 셋째, 작성된 평면도가 제공하는 공간 정보의 정확성을 검토하기 위해 금천교의 위치, 금천교와 진선문의 배치, 금천의 석축 위치를 시기에 따라 비교하였다. 그 결과 작성된 평면도의 내용이 금천교 발굴조사결과와 그 맥락을 함께 함으로써 러버쉬팅변환이 "동궐도(東闕圖)" 제작 당시 모습을 이해하는데 유용한 도구로서의 활용 가능성이 검증되었다. 본 연구는 러버쉬팅변환을 적용하여 "동궐도(東闕圖)"에 수록된 공간정보를 2차원 평면도로 제작하기 위한 가능성을 모색하고, 이를 통해 조선후기 동궐의 모습을 이해하기 위한 새로운 방법론을 제시하였다는데 의의가 있다.

고령 환자의 관절경적 회전근 개 봉합술의 결과 (Arthroscopic Full-Thickness Rotator Cuff Repair in Elderly Patients)

  • 천상진;이동호;박용건;손승민
    • 대한정형외과학회지
    • /
    • 제55권1호
    • /
    • pp.38-45
    • /
    • 2020
  • 목적: 65세 이상 고령의 회전근 개 전층파열 환자에 대해 일열 봉합술 또는 교량형 봉합술을 시행하고 최소 2년간 추시한 임상적 결과와 영상의학적 결과를 분석한다. 대상 및 방법: 2008년 8월부터 2017년 8월 사이에 본원에서 회전근 개 전층파열로 진단하고 보존적 치료 시도에 불응하는 65세 이상 환자에 대해 관절경적 회전근 개 봉합술을 시행하였다. 과도하지 않은 일정한 장력하에 견인하여 회전근 개 건이 족문 절반 이상을 덮으면 교량형 봉합술을, 절반 이상을 덮지 못하면 일열 봉합술을 시행하였다. 술 후 6개월째 시행한 추시 자기공명영상과 술 후 2년째 시행한 임상적 평가 지표(The University of California Los Angeles score, Constant Shoulder Score, visual analogue scale)를 참고하여 분석하였다. 환자의 술 전후 임상적 평가 지표, 술 후 구조적 연속성 분포 및 재파열 빈도를 분석하였다. 결과: 연구대상 기준을 충족한 환자는 모두 158예로 일열 봉합술 93예, 교량형 봉합술 65예였다. 임상적 지표는 전례에서 술 후 유의하게 향상되었고 두 군 간의 유의한 차이는 보이지 않았다. 구조적 연속성의 Sugaya 분류 분포는 1형 49예(31.0%), 2형 62예(39.2%), 3형 30예(19.0%), 4형 11예(7.0%), 5형 6예(3.8%)를 보였고 재파열률은 일열 봉합군에서 9.7% (93예 중 9예), 교량형 봉합군에서 12.3% (65예 중 8예)를 보였다. 결론: 65세 이상 고령 환자의 회전근 개 전층파열 환자에 대한 관절경적 봉합술 결과, 우수한 임상적 및 방사선적 결과를 얻었으며 일열 봉합술과 교량형 봉합술 모두 유용한 것으로 생각한다.

Analysis of a New Parallel Three-Level Zero-Voltage Switching DC Converter

  • Lin, Bor-Ren;Chen, Jeng-Yu
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권1호
    • /
    • pp.128-137
    • /
    • 2015
  • A novel parallel three-level zero voltage switching (ZVS) DC converter is presented for medium voltage applications. The proposed converter includes three sub-circuits connected in parallel with the same power switches to share load current and reduce the current stress of passive components at the output side. Thus, the size of the output chokes is reduced and the switch counts in the proposed converter are less that in the conventional parallel three-level DC/DC converter. Each sub-circuit combines one half-bridge converter and one three-level converter. The transformer secondary windings of these two converters are connected in series in order to reduce the size of output inductor. Due to the three-level circuit topology, the voltage stress of power switches is equal to $V_{in}/2$. Based on the resonant behavior by the output capacitance of power switches and the leakage inductance (or external inductance) at the transition interval, each switch can be turned on under ZVS. Finally, experiments based on a 2 kW prototype are provided to verify the performance of the proposed converter.

전계결합을 이용한 면대면 무선 에너지 전송회로 개발 (Power Stage Design for a Surface Wireless Power Transmission System using a Coupled Electric Field)

  • 최성진;김세영;최병우
    • 제어로봇시스템학회논문지
    • /
    • 제20권2호
    • /
    • pp.143-148
    • /
    • 2014
  • Conventional wireless power transfer methods based on coupled magnetic fields need a complex winding structure on the surface of the energy transfer and shows poor efficiency near metal objects due to the eddy current effect. In this study, to mitigate these problems, we investigate an electric field-coupled power transmission system, which is less prone to metal object problems and EMI. Because of the fundamental physical limit in the size of link capacitances, a half-bridge converter with an impedance matching transformer is proposed and the design procedure is derived to provide a soft-switching scheme. Hardware implementation shows that the proposed scheme with a pair of 10cm by 10cm copper plate can power a 1.4W USB FAN in a separation of 0.2mm by using insulating paper when driven by 227 kHz gate pulse.

Study on Change of Poly ADP Ribose Polymerase in the Rat with Thrombotic Stroke by Full Wave Cockroft Walton method's Transcranial Magnetic Stimulation

  • Kim, Whi-Young;Kim, Jun-Hyoung
    • Journal of Magnetics
    • /
    • 제19권1호
    • /
    • pp.20-27
    • /
    • 2014
  • This study examined the relationships between protein expression and Poly ADP ribose polymerase in brain cell death in brains damaged by thrombotic stroke and treated with the Full Wave- Cockroft Walton (FWCW) method of Transcranial Magnetic Stimulation (TMS). The two-way switching element for TMS drove a half-bridge inverter of the current resonance of direct current voltage (+) and direct current voltage (-), and the experiment was conducted by stimulating the mice with thrombotic stroke through a range of pulses. Thrombotic stroke was caused of ligation of the common carotid artery of male SD mice, and blood reperfusion was conducted five minutes later. Protein expression was examined in immune reaction cells, which reacted to an antibody to Poly ADP ribose polymerase in the cerebrum cells, and western blotting. Observations of the PARP changes after thrombotic stroke showed that the number of Poly ADP ribose polymerase reactions were significantly lower (p < 0.05) in the group treated with TMS of the FWCW than the group with thrombotic stroke 24 hours after its onset. The application of FWCW-TMS helped prevent the necrosis of nerve cells and might prevent the brain damage that occurs as a result of thrombotic stroke, and improve the function recovery and disorder of brain cells.

액티브 스너버를 이용한 고주파 용접기 컨버터 개발 (Development of Converter for High Frequency Welding Machines using Active Snubber)

  • 신준영;이재민;최승원;이준영
    • 전력전자학회논문지
    • /
    • 제21권4호
    • /
    • pp.351-355
    • /
    • 2016
  • Welding machines are high-capacity systems used in a low-frequency range using IGBT. As their system is similar to a large transformer, most welding machines suffer a great loss because of hard switching and vast leakage inductance. A voltage-balancing circuit is designed to overcome these shortcomings. This circuit can reduce the transformer size by making it into a high frequency and reducing the input voltage by half and by adopting a serial structure that connects two full-bridges in a series to use a MOSFET with a good property at high frequency. In addition, a Schottky diode is used in the primary rectifier to overcome the low efficiency of most welding machines. To use the Schottky diode with a reliably relatively low withstanding voltage, an active snubber is adopted to effectively limit the ringing voltage of the diode cut-off voltage.

IGBT-MOSFET 병렬 스위치를 이용한 고효율 직류-직류 변환기 (A High Efficiency DC-DC Converter Using IGBT-MOSFET Parallel Switches)

  • 장동렬;서영민;홍순찬;윤덕용;황용하
    • 전력전자학회논문지
    • /
    • 제4권2호
    • /
    • pp.152-158
    • /
    • 1999
  • IGBT는 전압정격 및 전류정격이 높고 도통손실이 낮아서 스위칭 전원장치에 많이 쓰이고 있는 추세에 있다. 그러나 IGBT는 MOSFET에 비해 스위칭 특성이 좋지 않아서 스위칭 손실이 많이 발생하며 주파수에도 제한을 받는다. 본 논문에서는 IGBT와 MOSFET의 장점을 살리기 위하여 IGBT에 MOSFET를 병렬로 접속한 IGBT-MOSFET 병렬 스위치를 사용한 2.4kW, 48V 출력의 고효율 반브리지 직류-직류 변환기를 제안한다. 병렬 스위치에서 주 스위칭 소자인 IGBT는 도통구간에서 주된 역할을 하며 MOSFET는 스위칭시에 주된 역할을 한다. 스위칭 손실을 분석하기 위하여 선형화 모델을 사용하였으며 시뮬레이션을 통하여 변환기의 동작을 확인하였다.

  • PDF

Pulse Density Modulation Controlled Series Load Resonant Zero Current Soft Switching High Frequency Inverter for Induction-Heated Fixing Roller

  • Sugimura, Hisayuki;Kang, Ju-Sung;Saha, Bishwajit;Lee, Hyun-Woo;Nakaoka, Mutsuo
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.226-228
    • /
    • 2006
  • This paper presents the two lossless auxiliary inducors-assisted voltage source type half bridge(single ended push pull:SEPP) series resonant high frequency inverter for induction heated fixing roller in copy and printing machines. The simple high-frequency inverter treated here can completely achieve stable zero current soft switching (ZCS) commutation forwide its output power regulation ranges and load variations under constant high frequency pulse density modulation (PDM) scheme. Its transient and steady state operatprinciple is originally described and discussed for a constant high-frequency PDM control strategy under a stable ZCS operation commutation, together with its output effective power regulation charactertics-based on the high frequency PDM strategy. The experimenoperating performances of this voltage source SEPP ZCS-PDM series resonant high frequency inverter using IGBTs are illustrated as compared with computer simulation results and experimenones. Its power losses analysis and actual efficiency are evaluated and discussed on the basis of simulation and experimental results. The feasible effectiveness of this high frequency inverter appliimplemented here is proved from the practical point of view.

  • PDF

대용량 및 높은 입력전압에 적합한 새로운 Three Level DC/DC 컨버터 (A Novel Three Level DC/DC Converter for High power applications operating from High Input Voltage)

  • 한상규;오원식;문건우;윤명중
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(1)
    • /
    • pp.317-322
    • /
    • 2003
  • A novel three-level DC/DC converter (TLC)for high power applications operating from high input voltage Is proposed. Its switch voltage stress can be ensured to be only one-half of the Input voltage. Nevertheless, since all input voltage is applied to the transformer primary side, it has good turns ratio. The driving method of each module is same as those of the conventional phase-shifted ZVS full bridge PWM converter (PSFB) and the zero-voltage-switching (ZVS) of the leading leg are achieved exactly in the same manner as that of the PSFB. Moreover, its three-level operation can considerably reduce the current ripple through the output inductor and it has no problems of the DC-link voltage unbalance. Therefore, it features a low voltage stress, high efficiency, low EMI, high power density, and small sized filter. To confirm the operation, validity, and features of the proposed circuit, experimental results from a 200W, 600V/DC-48V/DC prototype are presented.

  • PDF