Design and Performance Evaluation of Electrical Impactor for Nano Environmental Aerosols (나노 환경입자 측정용 전기적 임팩터의 설계 및 성능평가)

  • Ji, Jun-Ho;Cho, Myung-Hoon;Bae, Gwi-Nam;Hwang, Jung-Ho
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1417-1422
    • /
    • 2003
  • An electrical cascade impactor is a multistage impaction device to separate airborne particles into aerodynamic size classes using electrical method. We designed a real-time three-stage electrical low-pressure impactor, which is proper to nanometer sized environmental aerosols. Performance evaluation was carried out for stage 1 and 2. The monodisperse liquid dioctyl sebacate (DOS) particles were generated using condensation-evaporation followed by electrostatic classification using DMA (differential mobility analizer) for particles with diameters in the range of $0.04{\sim}0.8{\mu}m$. The evaluation of the electrical impactor is based on the use of two electrometers, one connected to the impaction plate of the impactor, and the other to the faraday cage as backup filter. The results showed that the experimental 50% cutoff diameters in the operation pressure were 0.53 and $0.12{\mu}m$ for stage 1 and stage 2. The effect of operation pressure on the cutoff diameter and the steepness of collection effcieicy curves is investigated.

  • PDF

An Experimental Study on the Operation of a Power Generation Engine with Syngas from RPF (폐기물 열분해 합성가스를 이용한 발전용 엔진구동에 대한 실험적 연구)

  • Jeong, Hyo-Jae;Lee, Jeong-Woo;Lee, Jae-Wook;Moon, Ji-Hong;Choi, In-Soo;Park, Sang-Shin;Hwang, Jung-Ho;Yu, Tae-U;Lee, Uen-Do
    • Journal of the Korean Society of Combustion
    • /
    • v.15 no.3
    • /
    • pp.48-56
    • /
    • 2010
  • Performances of power generation engine were investigated with syngas from RPF. A stoker type, multi-staged pyrolysis-gasification system, was employed for syngas generation and the syngas was refined with the sequential cleaning processes composed of a gas cooler, a bag filter and a wet scrubber. 20 kWe commercial syngas power generation engine was adopted to burn the cleaned syngas which is mainly composed of hydrogen, carbon monoxide, carbon dioxide and methane. The performance of the engine was tested with various syngas compositions and the results were compared to LNG case. Electric power output, exhaust gas temperature, and emission characteristics were measured, and the efficiency of engine generation was investigated as a function of load of power generation.

Nano Particle Charging Characteristics of Aerosol Charge Neutralizers (에어로졸 중화기의 나노 입자 하전 특성)

  • Ji, Jun-Ho;Bae, Swi-Nam;Hwang, Jung-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.10
    • /
    • pp.1489-1497
    • /
    • 2003
  • Aerosol charge neutralizers with various radioactive sources have been used to apply an equilibrium charge distribution to aerosols of unknown charge distribution. However, the performance of aerosol charge neutralizers is not well known, especially for highly charged particles. Measurements of highly charged particles are needed in air cleaning devices, e.g. electrostatic precipitator, bag filter with a pre-charger, and electrical cyclone. In this study, the particle charging characteristics of two different aerosol charge neutralizers were experimentally investigated for singly charged monodisperse particles and highly charged polydisperse particles. One has radioactive source of $^{85}$ Kr (beta source, 2 mCi) and the other has $^{210}$ Po (alpha source, 0,5 mCi). The air flow rate passing through each aerosol charge neutralizer was changed from 0.2 to 2.5 L/min. The results show that the charge distribution of singly charged monodisperse particles passing through the $^{85}$ Kr aerosol charge neutralizer is well agreed with the Boltzmann equilibrium charge distribution at an air flow rate of 0.3 L/min, However, it deviates from the equilibrium charge distribution when the air flow rates are 0.6, 1,0, and 1,5 L/min, On the other hands, the effect of air flow rate is insignificant for the $^{210}$ Po aerosol charge neutralizer. The non-equilibrium character in charge distribution of highly charged polydisperse particles passing through the $^{85}$ Kr aerosol charge neutralizer greatly depends on the air flow rate, however it is insensitive to the air flow rate for the $^{210}$ Po aerosol charge neutralizer.

Separator Effect on the Cell Failure of Lithium Secondary Battery using Lithium Metal Electrode (리튬금속 전극을 이용한 리튬이차전지의 내부단락에 대한 분리막의 영향)

  • Kim, Ju-Seok;Bae, Sang-Ho;Hwang, Min-Ji;Heo, Min-Yeong;Doh, Chil-Hoon
    • Journal of the Korean Electrochemical Society
    • /
    • v.14 no.3
    • /
    • pp.171-175
    • /
    • 2011
  • Lithium secondary batteries using lithium metal count electrode are easy to use and to analyze the specific characteristics of working electrode. Nevertheless, during the charge operation internal electrical short circuit could be caused by the dendritic growth of lithium. The cell failure by the short circuit depends on the condition of separator such as constitutive material and thickness. To prevent the cell failure caused by the dendritic growth of lithium, the electrochemical properties of the cell of lithium metal count electrode were evaluated for four different kinds of separator. Among the tested separators, GMF (glass micro-fiber filter, $300{\mu}m$) was the most promising one because it could effectively prevent the cell failure during the charge. The cell using GMF separator had relatively low impedance. Generally the cell using thicker separator than $50{\mu}m$ could effectively avoid the cell failure by internal short circuit and had the good cycleability. The highest rate capability by the signature method was acquired in the case of GMF separator.

Rapid Detection Method for Human Rotavirus from Vegetables by a Combination of Filtration and Integrated Cell Culture/Real-Time Reverse Transcription PCR (Filtration과 Integrated Cell Culture/Real-Time Reverse Transcription PCR 기법을 이용한 채소류에서 Human Rotavirus 신속 검출)

  • Hyeon, Ji-Yeon;Chon, Jung-Whan;Song, Kwang-Young;Hwang, In-Gyun;Kwak, Hyo-Sun;Lee, Jung-Soo;Kim, Moo-Sang;Lee, Jung-Bok;Seo, Kun-Ho
    • Korean Journal of Microbiology
    • /
    • v.47 no.2
    • /
    • pp.117-123
    • /
    • 2011
  • The purpose of this study was to evaluate and compare different elution and concentration methods for optimization of human rotavirus (HRV) detection method using real-time RT-PCR and cell culture techniques. The leafy vegetable samples (lettuce, Chinese cabbage) were artificially inoculated with HRV. Viruses were extracted from the vegetables by two different elution buffers, buffer A (100 mM Tris-HCl, 50 mM glycine, 3% beef extract, pH 9.5) and buffer B (250 mM Threonine, 300 mM NaCl, pH 9.5), and the extracted viruses were concentrated by filtration and PEG precipitation sequentially. To determine infectivity of the viruses, the viruses recovered from the samples were infected to the MA-104 cells, and integrated cell culture real-time RT-PCR was performed at 1, 48, 72, 96, 120, 144, 168 h post-infection (p.i.). The elution buffer A was more efficient in extracting the virus from the produce samples tested than the buffer B, 29.54% and 18.32% of recoveries, respectively. The sensitivity of real-time RT-PCR method was markedly improved when the virus was concentrated by the filtration method. When the viruses were eluted and concentrated by buffer A and filtration, respectively, the average recovery rate was approximately 51.89%. When the viruses recovered from samples were infected to MA-104 cell, infectious HRV was detected within 48 h p.i. by ICC/real-time RT-PCR, whereas cytopathic effects were not observed until 72 h p.i. The optimized detection method evaluated in this study could be useful for rapid and reliable detection of HRV in fresh produce products and applied for detection of other food-borne viruses.