• 제목/요약/키워드: HVDC cable

검색결과 61건 처리시간 0.031초

고조파에 의한 초전도 직류 전력케이블의 손실 특성 분석 (Harmonics based loss characteristics analysis of HTS DC power cable)

  • 김성규;김석호;박민원;유인근;이상진;조전욱;심기덕;원영진;황시돌
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제13권3호
    • /
    • pp.19-23
    • /
    • 2011
  • An HTS DC power cable is expected to perfectly eliminate transmission loss caused by resistance. However, when the HTS DC power cable is applied to the power system, loss of the HTS DC power cable is generated due to harmonics caused by HVDC converter. We designed and analyzed the HTS DC power cable with a critical current of 1 kA to investigate the loss characteristics using a finite element method package. In this paper, the loss characteristics caused by harmonics in the HTS DC power cable were analyzed according to order and magnitude of harmonics. Based on the analysis results, the critical current of HTS DC power cable considered with the rated current could be determined to minimize the capacity of cooling system for the design the HTS DC power cable.

진도~제주간 직류연계 사업을 위한 변환소 건설 개요 (The Introduction of Converter Station Construction for HVDC Link Project between Jindo and Jeju)

  • 이종석;문봉수;강원탁;김경석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.357_358
    • /
    • 2009
  • According to the 4th BPE(Basic Plan for long-term Electricity Supply and Demand), Electricity demand of Jeju island in 2012 will be reached to 682MW. Jeju island will be faced with severe shortage of electricty, also needed to find transport route to supply green energy which will be made from "Carbon free island" energy policy toward land at that time. For that reason, The plan which construct 400MW size HVDC connection line was decided for potential supply stabilization and transportation of green energy. KEPCO organized special construction office not only to observe the successful project completion which aims 2011 December but also to build up professional manpower. KEPCO is putting spur to the HVDC project these days. Construction site of converter stations has been already confirmed and contracts of cable, converter have done as per turn-key early this year. On this report, we would like to discuss about project scheme, main characteristics of system, and the furture progress plan of "Jindo~Jeju HVDC construction project expecially converter station part" which is being pushed by KEPCO.

  • PDF

HVDC용 크라프트 절연지의 전기적 특성 평가 (Electrical Properties on Kraft Insulating Paper used as HVDC Cable)

  • 연복희;이상진;김정년;김동욱;전승익
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2250-2252
    • /
    • 2005
  • 본 논문은 HVDC용 크라프트 절연지의 기본 전기적 특성평가를 목적으로 온도별 역률의 변화, 절연저항 및 임펄스 절연파괴강도 등을 측정한 결과이다. 온도에 따른 크라프트 절연지의 역률은 $50{\sim}70^{\circ}C$에서 최소 값을 나타내었으며, 밀도가 낮은 시료일수록 낮은 역률을 나타내었다. 하지만, 임펄스 절연파괴 강도는 밀도가 낮을수록 저하되는 특성을 나타내어 적절한 밀도의 선정이 필요하다는 사실을 알았다. 또한, 온도 및 인가 전계에 따른 절연저항을 측정하여 크라프트 절연지의 온도상수 및 전계상수를 측정한 결과, 온도상수 ${\alpha}$$0.09{\sim}0.1^{\circ}C^{-1}$, 전계상수는 약 1.5을 얻었다. 이는 HVDC용 케이블의 설계 시 절연체의 전계분포 및 두께 산정에 기본적인 데이터를 제공할 수 있다.

  • PDF

육지-제주간 초고압직류연계선로 제어용 해저광통신케이블 도입사례 (The cases of applying submarine optical fiber cable to control HVDC link between JEJU and main land)

  • 유승환;유동희;홍승택;신현조;주재성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.400-402
    • /
    • 2008
  • 제주도의 지속적인 전력수요 증가에 능동적으로 대처하고자 육지-제주간 초고압 직류연계(HVDC) 추가 건설사업이 추진 중에 있다. 초고압 직류 송전계통을 신뢰성 있게 운전하기 위해 양측 변환소에 설치될 제어 및 감시계통간 정보전송로의 화보는 매우 중요하다. 본 논문에서는 고품질, 대용량화 되어가는 전력데이터를 안정적으로 전송하고 해저케이블 고장감시 및 향후 정보 통신 분야의 부가가치 창출을 위한 최적의 해저광통신케이블을 소개하고자 한다.

  • PDF

계통과도전압분석기를 이용한 직류송전선로의 과전압에 대한 기초적 해석 (The Basic Study on Overvoltage of HVDC Transmission Line Using TNA)

  • 우정욱;심정운;곽주식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1810-1812
    • /
    • 1997
  • This paper describes the results of ground fault analysis on HVDC Transmission Line using TNA (Transient Network Analyzer). The maximum overvoltage is about 1.7 p.u. in the case of single line to ground fault on the overhead transmission line. When the cable is linked to the end of the overhead transmission line, the maximum overvoltage is about 1.58 p.u..

  • PDF

HDPE/EVA혼합수지의 공간 전하 분포에 관한 연구 (A Study on Space Charge Distribution of HDPE Mixed with EVA)

  • 정의환;허준;윤재훈;임기조;이흥규
    • 전기학회논문지
    • /
    • 제58권11호
    • /
    • pp.2229-2235
    • /
    • 2009
  • In this paper, each specimen blended at weight proportions of 80% HDPE to 20% EVA, 70% HDPE to 30% EVA, 60% HDPE to 40% EVA, and 50% HDPE to 50% EVA was manufactured respectively. The insulation performances of the proposed insulator were compared with conventional XLPE, main insulating material of CV cable on the basis of the investigation results of DC insulation performances. From the space charge density, electric field and potential profiles with raising DC voltage and time variation in HE82, distortion of electric field distribution was improved. As EVA mixed into the bulks acts as nucleation in crystallization process of HDPE, the size of spherulites became decreased and finally formed continuous network structure. Ultimately, it resulted from extinction of space charge in the interfacial region of spherulites.

제주지역 전력공급 대안과 특성분석 (A Study on the Generating Capacity Expansion Characteristics in Jeju Island)

  • 김창수;이창호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.275-277
    • /
    • 2004
  • Although Jeju island Is connected with main network system by HVDC cable line, it's network assumes the form of independent system in an operating point of view. Therefore Jeju needs it's own independent capacity expansion planning. Continuos growth of demand and increase of antiquated plants in Jeju requires additional generating capacity. This paper analyzes characteristics of two alternatives which include it's own expansion of facilities and capacity expansion of network system for Jeju island. Furthermore this paper evaluates economic efficiency of those alternatives and analyzes long-term program of demand-supply of electricity.

  • PDF

A New Directional Coupler Type Partial Discharge Sensor Installed on the Power Lead of Rotating Machine

  • Yi, Sang-Hwa;Hwang, Don-Ha;Park, Wee Sang
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권6호
    • /
    • pp.1769-1776
    • /
    • 2016
  • For on-line partial discharge (PD) monitoring of rotating machines, a novel sensor is proposed, which can be installed on the power lead inside the terminal box of the machine. The sensor has been designed to have high capacitance, and minimal reflection of measured pulses. As a sensitivity of the sensor, transfer impedance $Z_t$ has been measured and compared to conventional coupler-type sensors. A simple method is presented for measuring $Z_t$ of coupler sensors, using a vector network analyzer and a practical lead-cable of rotating machine. Through this method, it became possible to measure the $Z_t$ of coupler sensors including the installation environment of them. The $Z_t$ of the proposed sensor is higher than that of same sized other conventional couplers at frequencies between 30 and 92 MHz. Another sensitivity test has been performed using a PD calibrator as a test pulse source. The proposed sensor has higher measured peak voltage than the conventional coupler type sensors when the same charges were input.

나노 충진제에 따른 에폭시 나노 컴퍼지트의 절연파괴강도 특성 (Dielectric Breakdown Characteristics Depending on The Nano Filler of Epoxy Nano-composites)

  • 박태학;백승학;이동건;박홍규;정인범;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.92-92
    • /
    • 2010
  • In this paper, the test is performed on MgO, which is used as a filler in epoxy additives, respectively (0, 1.0, 3.0, 5.0, 7.0, 10 [wt%]) for HVDC(high voltage direct current) submarine cable insulating material to improve electrical properties of epoxy resin in high temperature. The breakdown strength due to increasing amount of filler increased to 5.0 [wt%] by the effects of the Coulomb blockade. However, it is confirmed that strength of dielectric breakdown decreased because the filler functioned as impurities and affected the breakdown when filler additive exceeded by 5.0 [wt%] or more. We have found that the highest dielectric breakdown strength of specimen added 5.0 wt% at $25^{\circ}C$, and is more increased approximately 13.7 [%] than virgin specimen.

  • PDF

MgO를 첨가한 에폭시 나노 컴퍼지트의 절연파괴강도 온도의존성 (Temperature Dependence on dielectric breakdown strength of Epoxy Nano-Composites depending on MgO)

  • 정인범;한현석;이영상;조경순;신종열;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.48-48
    • /
    • 2010
  • In this paper, we have investigated temperature dependence of dielectric breakdown voltage at epoxy with added nano-filler(MgO), which is used as a filler of epoxy additives for HVDC(high voltage direct current) submarine cable insulating material with high thermal conductivity and restraining tree to improve electrical properties of epoxy resin in high temperature region. In order to find dispersion of the specimen, the cross sectional area of nano-composite material is observed by using the SEM(Scanning Electron Microscope) and it is conformed that each specimen is evenly distributed without the cohesion. As a result, it is confirmed that the strength of breakdown of all specimen at 50 [$^{\circ}C$] decreased more than that of the dielectric breakdown strength at room temperature. When temperature increases from 50 [$^{\circ}C$] to 100 [$^{\circ}C$], we have confirmed that breakdown strength of virgin specimen decreases, but specimens with added MgO show constant dielectric breakdown strength.

  • PDF