• 제목/요약/키워드: HVDC cable

검색결과 60건 처리시간 0.048초

Search Coil법의 EMTP 분석을 통한 HVDC 케이블 상세 고장지점 판정 정확도 개선 (Improvement of Detailed Fault Point Decision Using EMTP Analysis of Search Coil Method for HVDC Cables)

  • 정채균;박진우;양병모;강지원;이종범
    • 전기학회논문지
    • /
    • 제60권9호
    • /
    • pp.1656-1662
    • /
    • 2011
  • In a previous paper, the EMTP modeling technique using search coil test is established through various transient analysis including system grounding condition and grounding resistance for HVDC submarine cables. It was also proved by comparison with real test results. Based on this EMTP modeling technique, in this paper, it will be applied for modeling of ${\pm}180kV$ real HVDC submarine system(Jeju~Haenam). This paper variously analyses the effects of fault resistance including the resistance between core and sheath, the resistance between sheath and amore and the resistance between amore and sea water through EMTP modeling of search coil method. The results can contribute to the accuracy of detailed fault point prediction of search coil test for HVDC submarine cables.

HVDC 해저케이블 고장점 탐지를 위한 EMTP 모델링 (EMTP Modeling for Fault Location in HVDC Sea Submarine Cable)

  • 양병모;박진우;박준우;최경규;강지원;윤형희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 Techno-Fair 및 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.79-80
    • /
    • 2008
  • 제주-해남간 운영중인 HVDC 해저케이블에서 발생한 절연파괴사고('06.4)와 관련하여 써징코일을 이용한 고장점 탐색을 실시하고 고장지점 추정 및 향후 대책마련에 활용하코자, 제주-해남 HVDC 해저케이블 고장점 모의용 EMPT 모델링을 개발하였으며 유인잠수정을 이용한 실측 데이터 값과 EMTP를 활용한 시뮬레이션값을 비교하였다. 향후, 다양한 HVDC 해저케이블 고장유형에 따른 과도해석용 시뮬레이션을 위하며 본 논문에서 개발한 EMTP 모델링 활용이 가능할 것으로 생각된다.

  • PDF

HVDC 해저케이블 고장점 탐지 사례 연구 (A Study on the HVDC Submarine Cable Fault Location Searching Case)

  • 문신용;김정대;장석한
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.138-140
    • /
    • 2006
  • 한국전력공사(이하 한전)에서는 제주지역 전력공급의 안정을 위해 '98년부터 국내 최초로 육지전력 계통과 연계하여 장거리 해저케이블 송전선로를 건설하여 운영하고 있다. 해저케이블은 해저에 포설되고 외부적 환경에 견디기 위해 육상케이블과 다른 많은 보호층을 포함하고 있어 설비의 유지보수에 많은 제약사항을 안고 있다. 특히 해남${\sim}$제주 연계선로는 기술적 장점 때문에 AC송전 대신 HVDC 송전을 하고 있어 한단계 Upgrade된 설비운영 기술이 필요하다. 본 고에서는 HVDC 해저 케이블의 설비운영에 있어 선로의 고장시 케이블의 고장점 위치를 탐지하는데 중점을 두어 실제 고장점 탐지 사례를 중심으로 HVDC 해저 케이블 고장점 탐지 방법 및 시험 결과를 검토하고 향후 유사 고장 발생에 효과적으로 대응하기 위한 절차를 제시하였다.

  • PDF

HVDC 육상케이블 매설위치 탐지특성 분석 (Study on the Searching Property of Buried Position for HVDC Land Cable)

  • 안용호;장병태;송인준;곽노홍;황갑철;정길조;이태희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.746-747
    • /
    • 2007
  • 본 논문은 HVDC 해저케이블 육상구간 지중선로 매설경과지 탐지와 관련하여, 해남-제주간 연계선로의 지중구간에 매설된 HVDC 지중케이블의 정확한 매설경과지 정보 획득 가능성 진단을 목적으로 HVDC 시스템 운전상태에서 해저케이블 탐지 시스템을 육상에 적용하여 현장탐색 측정을 실시한 결과 및 향후 가능성을 제시하였다.

  • PDF

HVDC 해저케이블 장기과통전 신뢰성 시험평가 방법 (Evaluation on Long-Term Reliability of HVDC Submarine Cable)

  • 양병모;박준우;문경희;노태형;김양상;강지원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.377_378
    • /
    • 2009
  • HVDC 케이블은 장거리 전력전송, 국가간 계통연계, 비동기 전력계통연계, 전력의 시장화에 따른 전력공급 제어 필요에 따라 세계적으로 널리 사용되고 있다. 국내에서는 현재 유일하게 제주-해남간 180kV HVDC 해저케이블이 운영 중에 있으며, 향후 제주도의 안정적인 전력공급을 위하여 2011년에 제주-육지간 250kV HVDC 해저케이블이 추가로 건설될 예정이다. 그래서 HVDC 해저케이블의 신속 정확하게 안정적이고 신뢰성 있는 운영을 위해서 국내에서 자체 개발한 HVDC 해저케이블에 대한 장기과통전 시험에 대한 평가 및 절차가 필요하게 되었다. 본 논문에서는 HVDC 해저케이블의 장기과통전 시험평가를 위하여 전기적 시험은 CIGRE에서 권고하고 있는 Electra 189, 219에 근거하고 기계적 시험은 IEC 60055-1, Elecrta 171에 근거하여 기술하고자 한다.

  • PDF

Asymmetric Capacitive Sensor for On-line and Real-time Partial Discharge Detection in Power Cables

  • Changhee Son;Hyewon Cheon;Hakson Lee;Daekyung Kang;Jonghoo Park
    • 센서학회지
    • /
    • 제32권4호
    • /
    • pp.219-222
    • /
    • 2023
  • Partial discharges (PD) have long been recognized as a major contributing factor to catastrophic failures in high-power equipment. As the demand for high voltage direct current (HVDC) facilities continues to rise, the significance of on-line and real-time monitoring of PD becomes increasingly prominent. In this study, we have designed, fabricated, and characterized a highly sensitive and cost-effective PD sensor comprising a pair of copper electrodes with different arc lengths. The key advantage of our sensor is its non-invasive nature, as it can be installed at any location along the entire power cable without requiring structural modifications. In contrast, conventional PD sensors are typically limited to installation at cable terminals or insulation joint boxes, often necessitating invasive alterations. Our PD sensor demonstrates exceptional accuracy in estimating PD location, with a success rate exceeding 95% in the straight sections of the power cable and surpassing 89% in curved sections. These remarkable characteristics indicate its high potential for realtime and on-line detection of PD.

FEM을 이용한 초전도 직류 케이블의 손실 특성 분석 (Loss characteristics analysis of HTS DC cable using FEM)

  • 김성규;김석호;김진근;박민원;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.822-823
    • /
    • 2011
  • The authors analyzed harmonic current based loss of a high temperature superconducting (HTS) DC model cable. The loss in HTS DC cable is generated due to the variation of magnetic field caused by harmonic current in a HVDC transmission system. The authors designed and fabricated two meters of HTS DC model cable for verification of real loss characteristic. In this paper, the loss characteristics caused by harmonic current in the HTS DC model cable are analyzed using commercial finite element method software package. The loss of the HTS DC cable is much less than the loss of the HTS AC cable but the loss should be considered to decide a proper capacity of cooling system.

  • PDF

축소형 초전도 직류 케이블 시스템의 제작 및 시험 (Fabrication and test of a miniaturized superconducting DC cable system)

  • 김진근;김성규;박민원;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.794-795
    • /
    • 2011
  • The DC side voltage and current of a HVDC transmission system are directly affected by non-linear switching devices such as the thyristor valve which causes real power losses, even under the superconducting conditions of a high temperature superconducting (HTS) power cable. This paper deals with the development of miniaturized superconducting DC cable system. The authors designed and fabricated two thyristor converters for DC transmission system. One is operated as a rectifier and the other is an inverter. The HTS model cable was connected between the DC side of the rectifier and inverter. Real DC transport current and voltage were applied to the miniaturized HTS DC cable. Experimental results are discussed in detail.

  • PDF

HVDC 해저케이블 고장점 추정에 관한 연구 (A Study on Fault Location of HVDC Submarine Cables)

  • 정채균;박준우;문경희;양병모;강지원;김종채
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.369_370
    • /
    • 2009
  • This paper describes the fault location method for HVDC submarine cables. Most conventional fault location methods can be applied in off-line. However, in this paper, on-line fault location algorithm is proposed using multi-scale correlating of wavelet coefficient and travelling wave. The propagation velocity is measured by field test on Jeju-Heanam submarine cable section. Finally, the fault location algorithm is tested by same system modeling using EMTP/ATP.

  • PDF

고조파에 의한 초전도 직류 전력케이블의 손실 특성 분석 (Harmonics based loss characteristics analysis of HTS DC power cable)

  • 김성규;김석호;박민원;유인근;이상진;조전욱;심기덕;원영진;황시돌
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제13권3호
    • /
    • pp.19-23
    • /
    • 2011
  • An HTS DC power cable is expected to perfectly eliminate transmission loss caused by resistance. However, when the HTS DC power cable is applied to the power system, loss of the HTS DC power cable is generated due to harmonics caused by HVDC converter. We designed and analyzed the HTS DC power cable with a critical current of 1 kA to investigate the loss characteristics using a finite element method package. In this paper, the loss characteristics caused by harmonics in the HTS DC power cable were analyzed according to order and magnitude of harmonics. Based on the analysis results, the critical current of HTS DC power cable considered with the rated current could be determined to minimize the capacity of cooling system for the design the HTS DC power cable.