• 제목/요약/키워드: HVAC control system

검색결과 141건 처리시간 0.024초

공조설비 운전방법 및 시설개선을 통한 에너지절약 효과분석 (An Analysis of the Energy Saving Effect Through the Retrofit and the Optimal Operation for HVAC Systems)

  • 김용기;이태원
    • 설비공학논문집
    • /
    • 제24권4호
    • /
    • pp.343-350
    • /
    • 2012
  • The major goal of building energy management is to minimize the energy consumption while maintaining the comfortable environment condition. Nowadays building energy management to save HVAC energy and so on is the most critical issue for existing building service branch with high efficiency equipments and their optimal operation. The effects on the building energy savings of the building equipment retrofit and the improvement of its operation method, especially in the field of HVAC system, were analyzed in this study for domestic small and/or medium sized buildings. Over 8.8% of energy saving was achieved compared withe total energy consumption in commercial building. These results could be used for reasonable maintenance and efficient management of the various building service equipments and related systems.

하이브리드 적응 필터를 이용한 공조 덕트에서의 능동소음제어 (Active Control of Noise In HVAC Ducts Using Hybrid Adaptive Filter)

  • 남현도;김덕중;성대현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 G
    • /
    • pp.2417-2419
    • /
    • 1998
  • In this paper, a new active noise control technique which combines a hybrid active noise control technique and a subband active noise control technique is presented. To reduce the computational burden the active noise control system, a weighted hybrid control technique is applied. This algorithm shows higher stability and good noise attenuation property in either broad band or narrow band active noise control systems in HVAC ducts. Computer simulations were performed to show the effectiveness of the proposed algorithm.

  • PDF

원자력발전소 주제어실 화재 시 공조모드가 배연성능 및 거주성에 미치는 영향 분석 (Effect of the HVAC Conditions on the Smoke Ventilation Performance and Habitability for a Main Control Room Fire in Nuclear Power Plant)

  • 김범규;임혁순;이영승;김명수
    • 한국화재소방학회논문지
    • /
    • 제30권5호
    • /
    • pp.74-81
    • /
    • 2016
  • 본 연구의 목적은 원자력발전소 주제어실 화재시 운전원의 거주성을 평가하는 것이다. 운전원의 거주성 분석을 위해 FDS v.6.0을 사용하였으며 이를 통해 주제어실 화재 시 배연성능과 운전원의 거주성에 있어 도출되는 문제점을 확인하였다. 본 연구에서는 공조환기설비의 운전조건을 핵심변수로 지정하고 그에 따라 3가지 시나리오로 분류하였다. 수치해석결과, Case 1(공조설비 작동시)의 경우가 연기온도, 복사열, 광학밀도 및 연기층높이에 의한 영향이 가장 심각한 것으로 나타났다. 이에 반해, Case 2(공조설비 미작동시)와 Case 3(공조설비 미작동시 풍량 1.5배 증가 시)는 Case 1보다 더 안전한 것으로 나타났다. 약 820초경 연기온도를 확인한 결과, Case 1이 Case 2와 Case 3보다 약 63% 정도 더 높게 나타났다. 복사열에 의한 영향도 Case 1에서 가장 높게 나타나, Case 2 및 Case 3와는 최대 약 68% 이상의 차이를 보였다. 분석결과를 통해, 주제어실의 공조환기설비는 배연성능에 큰 영향을 미쳐 운전원 거주안전을 지키기 위한 주요 인자인 것을 확인하였다. 다만, 급기구와 배연구가 천정부에 동시에 설치되어 있어 Case 2와 Case 3의 경우 연기층높이에 있어 불연속적 패턴을 나타냈다.

고밀도 내부부하 중심 건물의 에너지 절약적 공조방식에 대한 연구 (Viability of HVAC System for Energy Conservation in High Density Internal-load Dominated Buildings)

  • 조진균;정차수;김병선
    • 설비공학논문집
    • /
    • 제22권8호
    • /
    • pp.530-537
    • /
    • 2010
  • With the advancement of technology, the density of IT equipment, heat load and power consumption continue to increase in high density internal-load dominated buildings as datacenters. To improve the HVAC system's energy performance and efficiency, there is a need to find methods of using outside air. Through cooling tower control that is based on outside wet-bulb temperature, the water-side economizer made it possible to achieve a maximum energy performance improvement of about 16.6% over the basic chilled water system, whereas the air-side economizer, through control based on outdoor air enthalpy, made it possible to achieve about 42.4% improvement.

자연환기와 복사냉방을 병용한 하이브리드 시스템의 제안 (A Proposal of Hybrid Cooling System Coupled with Radiation Panel Cooling and Natural Ventilation)

  • 송두삼
    • 설비공학논문집
    • /
    • 제15권6호
    • /
    • pp.543-550
    • /
    • 2003
  • In order to saving the energy for HVAC system of buildings, utilization of wind-induced cross ventilation is thought to be promising. However, utilization of natural ventilation alone is not sufficient for maintaining the human thermal-comfort such as in hot and humid regions. A hybrid air conditioning system with a controlled natural ventilation system, or combination of natural ventilation with mechanical air conditioning is thought to overcome the deficiency of wind-driven cross ventilation and to have significant effects on energy reduction. This paper describes a concept of hybrid system and propose a new type of hybrid system using radiational cooling with wind-induced cross ventilation. Moreover, a radiational cooling system is compared with an all-air cooling system. The characteristics of the indoor environment will be examined through CFD (Computational Fluid Dynamics) simulation, which is coupled with a radiation heat transfer simulation and with HVAC control in which the PMV value for the human model in the center of the room is controlled to attain the target value.

공조기를 적용한 고분내부 실내환경 (Indoor Environment of Inside Ancient Tomb with HVAC System)

  • 이금배;전희호;고석보;박진양;전용두
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.141-147
    • /
    • 2005
  • Although the importance of good conservation of historic sites including ancient royal tombs is wet] aware, still not much attention has been paid for the facilities and systems to preserve those historic sites, which includes precious artifacts as wall paints and carved works, etc. Even the general understanding about the environment of the underground space of tombs is not satisfactory. In the present study, vibration levels due to the operation of an HVAC system to maintain the desired indoor temperature and humidity are investigated experimentally. According to the measured data, the level of vibration inside the present model tomb with the indoor unit inside, showed order of magnitude less values than the Swiss Standards, but still higher than the value suggested by German standards, which is, zero. For the vibration level depends not only on the system design, but also on the installation methods, further study will be pursued for cases including different ways of installation.

  • PDF

LonWork fieldbus 기반을 가진 HVAC 공기조화기용 고성능 지능형제어모듈 개발 (A Novel Development of Distributed Intelligent Control Module Based on the LonWorks Fieldbus for Air Handling Units in the Healing, Ventilating and Air Conditioning)

  • 홍원표
    • 조명전기설비학회논문지
    • /
    • 제18권1호
    • /
    • pp.115-121
    • /
    • 2004
  • 본 연구에서는 프랜트 및 빌딩자동제어 분야에서 적용이 확대 되고 있는 LonWorks 필드버스를 이용하여 기존의 공기조화시스템를 제어하고 있는 DDC제어기를 대체할 수 있도록 필드버스에서 사용이 가능한 고성능 저가의 지능형 제어모듈을 개발하였다. 이는 필드버스 기반의 AHU 전용 지능형제어기를 새로운 설계기술로 개발하고 상품화를 실현하였다. 특히 S/W부분에서도 8 bit Neuron chip에 매우 콤팩트하게 내재된 고성능 응용프로그램도 개발하였다. 공조기의 실험시스템을 구축하여 개발된 전용 제어기를 실험한 결과 밸브, 댐퍼제어 및 감시기능이 기존 DDC 제어기보다 우수함을 확인하였다.