• Title/Summary/Keyword: HVAC control system

Search Result 142, Processing Time 0.024 seconds

A Study on HVAC Parameter Monitoring System (Regarding Computer Validation) (HVAC 파라미터 모니터링 시스템에 대한 고찰 (Computer Validation 중심으로))

  • Kim, Jong-Gu
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.90-95
    • /
    • 2008
  • This article presents practical advice regarding the implementation and management of an impeccable Building Management System. The BMS was introduced to the series of computerized systems including manufacturing, storage, distribution, and quality control. Recently revised GMP regulation is requesting an improvement in drug product quality regulatory system by computer system validation. Quality is critical to guarantee the efficacy and the safety of drugs and is approved in the evaluation process after the audit trail application. HVAC parameter monitoring system will record the identity of operators entering or confirming critical data. Authority to amend entered data should be restricted to nominated persons. Any alteration to an entry of critical data should be authorized in advance and recorded with the reason for the change.

  • PDF

FEG Development of MCR HVAC System for NPP (원자력발전소 주제어실 공기조화계통 기능적설비그룹 개발)

  • Hyun, Jin Woo
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.8 no.2
    • /
    • pp.21-25
    • /
    • 2012
  • Functional Equipment Group(FEG) of Nuclear Power Plant(NPP) is the bundling of multiple equipment subcomponents around a major equipment with a common system isolation characteristic or out-of-service consideration. The main purpose of FEG is to reduce out-of-service time to enhance maintenance effectiveness. KHNP(Korea hydro & Nuclear Power Co.) needs to develop these FEGs to successfully perform On-line Maintenance(OLM) which will be expected to institute in the future. Recently, there has been growing interest in OLM in KHNP. The aim of this paper is to suggest the way of FEG development and to build the FEG of MCR(Main Control Room) HVAC(Heat, Ventilation and Air Conditioning) system. The results of this study might be make good use of OLM and be helpful for equipment maintenance for MCR HVAC system.

VIBRATION CONTROL OF SYNCHROTRON LIGHT SOURCE BUILDING USING EXPERIMENTAL MODAL ANALYSIS (실험적 모우드 해석을 이용한 방사광 가속기 건물의 진동제어)

  • 박상규;이홍기;권형오
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1993.10a
    • /
    • pp.157-161
    • /
    • 1993
  • Optical devices and electronic equipments used in the laboratory of the synchrotron light source building of the accelerator have stringent vibration limits. In order to control the vibration of the building structure and HVAC systems which are main vibration sources are evaluated using experimental modal analysis. Double anti-vibration system is used for the HVAC system and results show that the double anti-vibration system reduces the vibrations of the building to acceptable levels.

  • PDF

Measurement and Analysis of Energy Consumption of HVAC Equipment of a Research Building (연구용 건물의 열원 및 공조기기의 에너지 소비량 측정 및 분석)

  • Kim Seong-Sil;Kim Youngil
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.10
    • /
    • pp.914-922
    • /
    • 2004
  • In this study, measurement and analysis of energy consumption of a research building have been conducted. The energy audit procedure includes monitoring of electricity and LNG consumption over a period of three yews from 2000 to 2002. Data acquisition system for collecting energy consumption data of HVAC equipment such as chillers, fan filter units, AHUs, cooling towers, boilers, pumps, fan coil units, air compressors and etc. has been installed in a building located in Seoul. Data collected at an interval of 1 minute are analyzed for studying the energy consumption pattern of a research building. Percentage of energy consumption of all HVAC equipment is $51.0\%$ in 2000, $55.4\%$ in 2001, and $62.3\%$ in 2002, respectively. Electricity consumption of chillers accounts for $17.6\%$ of the total energy consumption, which is the largest. Annual energy consumption-rate per unit area is $840.5Mcal/m^2{\cdot}y$ in 2000, $1,064.8Mcal/m^2{\cdot}y$ in 2001, and $1,393.0Mcal/m^2{\cdot}y$ year 2002, respectively.

A Numerical Study for Performance of Automotive HVAC System (전산해석에 의한 자동차용 HVAC 시스템의 성능 연구)

  • Lee Dae-Woong;Yoo Seong-Yeon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.11
    • /
    • pp.1084-1091
    • /
    • 2004
  • In automotive air handling system, mixing of air streams by the cooler and the heater affects the comfort of cabin room. In the present study, computer-aided analysis is done to improve the thermal comfort and for the optimal design of automotive HVAC system. The simulation software used was FLUENT, and complicate geometries were created by three dimensional CAD. Air flow volume, fir distribution rate and temperature controllability and temperature differences between upper and lower discharge air are analyzed through numerical simulation at vent, floor and defrost mode. Also, velocity vector of sirocco fan is investigated through the scroll housing. The velocity vector magnitude is larger at lower region of fan than that at any other regions. Recirculation and disturbance of air is relatively high near the cut-off edge in the scroll housing. By using the results of this study, the time for prototype production can be reduced and timely decisions can be made to determine initial design directions.

A study on the control of HVAC system (HVAC시스템의 제어에 관한 연구)

  • 홍규장;박성기;송언빈;정찬수
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1990.10a
    • /
    • pp.57-62
    • /
    • 1990
  • This paper describes the development and testing of a degitial controller for heat-ing ventilating and air-conditioning system. The controller uses properational-integral control action and self tunes to provide the Zigeler-Nichols when given a step input. The algorithm has been simulated fas static pressure.

  • PDF

An Enhanced Technologies of Intelligent HVAC PID Controller by Parameter Tuning based on Machine Learning

  • Kim, Jee Hyun;Cho, Young Im
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.12
    • /
    • pp.27-34
    • /
    • 2017
  • Design of an intelligent controller for efficient control in smart building is one of the effective technologies to reduce energy consumption by reducing response time with keeping comfortable level for inhabitants. In this paper, we focus on how to find major parameters in order to enhance the ability of HVAC(heating, ventilation, air conditioning) PID controller. For the purpose of that, we use machine learning technologies for tuning HVAC devices. We show the simulation results to illustrate the behavioral relation of whole system and each control parameter while learning process.

An application to HVAC control system based on occupants' thermal response in office buildings (공조제어 적용을 위한 재실자 온열반응 데이터의 유효성 분석에 관한 연구)

  • Han, Hyesim;Kim, Jonghun;Jeong, Hakgeun;Jang, Cheol-Yong
    • KIEAE Journal
    • /
    • v.14 no.4
    • /
    • pp.111-117
    • /
    • 2014
  • In South Korea, the government has recently enforced regulations associated with buildings. Temperature restriction in indoor environment is one of the common ways of energy reduction in order not to dissipate heating and cooling energy; however the people who are in restricted temperature feels uncomfortable. Furthermore, occupants cannot feel the same thermal sensation even they are in the same place. For the reason, occupants should express their thermal sensation and HVAC system should be able to apply their demand. It is proved by an adaptive principle. The adaptive model means that people react in ways which tend to restore their comfort, when change occurs such as to produce discomfort. In order to design HVAC control strategies based on adaptive model, we designated an existing office building as a reference building to gather data from actual field. Furthermore, we gathered occupants' thermal sensation and clothing insulation in real-time. We filtered the data with Kalman's filter method. The data was reasonable when there is an alarm messages for asking questionnaire. The response ratio were different in occupants' thermal condition. In conclusion, the filtered occupants' thermal sensation can be used as a real time HVAC control and input value of HVAC control.

Active Control of Noise in HVAC Ducts Using Fuzzy LMS Algorithms (퍼지 LMS 알고리즘을 이용한 공조덕트에서의 능동소음제어)

  • 남현도;안동준;박용식
    • Journal of KSNVE
    • /
    • v.9 no.2
    • /
    • pp.265-272
    • /
    • 1999
  • A LMS algorithms has been widely used for an adaptive filter algorithm in active noise control systems. But this algorithm has poor convergence and it is very difficult to select optimal convergence parameters in this algorithm. In this paper, a fuzzy LMS algorithm where the convergence parameters are computed using a fuzzy logic controller was proposed. A proposed algorithm was applied to active noise control system in HVAC(central Heating Ventilation and Air Conditioning) ducts. The experimental ducts and experimental apparatus were designed and manufactured for experiments, and the modelling of the experimental ducts was also performed for computer simulations. Computer simulations and experiments were performed to show the effectiveness of a proposed algorithm.

  • PDF

A Study of Rule-based Fault Detection Algorithm in the HVAC System (규칙기반 고장진단 알고리즘의 실험적 연구)

  • Cho, Soo;Tae, Choon-Seob;Jang, Cheol-Yong;Yang, Hoon-Cheol
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.241-246
    • /
    • 2005
  • The objective of this study is to develop a rule-based fault detection and diagnosis algorithm and an experimental verification using air handling unit. To develop an analytical algorithm which precisely detects a faulted component, energy equations at each control volume of AHU were applied. An experimental verification was conducted in the AHU at Green Building in KIER. In the experiment conducted in hot summer condition, the rule based FDD algorithm isolated a faulted sensor from HVAC components.

  • PDF