• 제목/요약/키워드: HVAC System

검색결과 431건 처리시간 0.03초

폐열회수환기를 위한 열교환장치의 경제성 평가 (An economic evaluation of heat exchanger for heat recovery ventilation)

  • 박용효;이상범
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2008년도 추계 학술논문 발표대회
    • /
    • pp.241-244
    • /
    • 2008
  • Recently, The high Air-Tightness and high heat insulation for building construction cause a ventilation air volume deficiency. Also, Worldwide high energy price is strongly urging to economize the air conditioning energy. Therefore Heat Recovery Ventilation is used for the satisfaction of ventilation air volume and building energy saving. Accordingly, this study dose the heat exchanger performance evaluation and economic efficiency evaluation of Heat Recovery Ventilation. And, we wish to make a basic study about HRV System application of HVAC System and Multi System Air-conditioning.

  • PDF

HACCP의 환경 최적화를 위한 식품 클린룸 설계에 관한 연구 (A study on the food clean room system observing the regulations of HACCP)

  • 원영재;서기원
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.520-526
    • /
    • 2009
  • This study proposed the optimum design values for the biological clean room system observing the regulations of Hazard Analysis Critical Control Point (HACCP). Even though the standard for industrial clean room system has been well established, the basis for biological food clean room system is the first stage. In order to prevent the contaminations in advance for food storages, processes, and distributions, the criterion of Hazard Analysis Critical Control Point is positively required. This study also suggested the possible ways of how to avoid the hazardous contaminations.

  • PDF

빌딩자동제어시스템의 공조설비에 적용을 위한 Internet 기반 모니터링 및 제어시스템 구축 (Internet_Based Monoitoring and Control System for Air handling Units in Building Automation System)

  • 홍원표
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.412-418
    • /
    • 2004
  • In this paper, a new distributed intelligent control module based on LonWorks fieldbus for air handling unit(AHU) of heating, ventilating and air-conditioning(HVAC) is proposed to replace with a conventional direct digital control(DDC) with 32 bit microprocessor. This article also addresses an Internet-based HVAC system architecture that combines Web technology and networking. The proposed control architecture has a excellent features such as highly compact and flexible function design, a low priced smart front-end and reliable performance with various functions. This also addresses issues in control network configuration, logical design of field devices by S/W tool, Internet networking and electronic element installation. Experimental results showing the system performance are also included in this paper.

  • PDF

실대실험에 의한 에어베리어형 페리미터레스 공조시스템의 실내 열환경 평가 (Evaluation of Thermal Environment through Large-scale Model Experiment on Air-barrier Type Perimeter-less System)

  • 김용경;이정재
    • 설비공학논문집
    • /
    • 제15권11호
    • /
    • pp.970-978
    • /
    • 2003
  • This paper aims at suggesting design guidelines for a perimeter-less HVAC system that contributes energy savings. Perimeter-less HVAC system is one that relieves difficulties such as handling mixing loss, uneven radiative environment, and maintenance and repair. It prevents heat load gained through window and outdoor wall without modifying a previously equipped building skin system. In this paper, we conducted a large-scale model experiment to see how the push-pull air flow would handle indoor heat to obtain an optimized perimeter-less design, and then we plan to perform several kinds of CFD (computational fluid dynamics) cases through numerical simulation

원자력발전소 주제어실 화재 시 공조모드가 배연성능 및 거주성에 미치는 영향 분석 (Effect of the HVAC Conditions on the Smoke Ventilation Performance and Habitability for a Main Control Room Fire in Nuclear Power Plant)

  • 김범규;임혁순;이영승;김명수
    • 한국화재소방학회논문지
    • /
    • 제30권5호
    • /
    • pp.74-81
    • /
    • 2016
  • 본 연구의 목적은 원자력발전소 주제어실 화재시 운전원의 거주성을 평가하는 것이다. 운전원의 거주성 분석을 위해 FDS v.6.0을 사용하였으며 이를 통해 주제어실 화재 시 배연성능과 운전원의 거주성에 있어 도출되는 문제점을 확인하였다. 본 연구에서는 공조환기설비의 운전조건을 핵심변수로 지정하고 그에 따라 3가지 시나리오로 분류하였다. 수치해석결과, Case 1(공조설비 작동시)의 경우가 연기온도, 복사열, 광학밀도 및 연기층높이에 의한 영향이 가장 심각한 것으로 나타났다. 이에 반해, Case 2(공조설비 미작동시)와 Case 3(공조설비 미작동시 풍량 1.5배 증가 시)는 Case 1보다 더 안전한 것으로 나타났다. 약 820초경 연기온도를 확인한 결과, Case 1이 Case 2와 Case 3보다 약 63% 정도 더 높게 나타났다. 복사열에 의한 영향도 Case 1에서 가장 높게 나타나, Case 2 및 Case 3와는 최대 약 68% 이상의 차이를 보였다. 분석결과를 통해, 주제어실의 공조환기설비는 배연성능에 큰 영향을 미쳐 운전원 거주안전을 지키기 위한 주요 인자인 것을 확인하였다. 다만, 급기구와 배연구가 천정부에 동시에 설치되어 있어 Case 2와 Case 3의 경우 연기층높이에 있어 불연속적 패턴을 나타냈다.