• Title/Summary/Keyword: HVAC시스템

Search Result 264, Processing Time 0.034 seconds

Efficiency of Photoplasma of HVAC System for Train (철도차량 HVAC시스템의 광플라즈마 성능평가)

  • Han, Hwan-Su;Jeon, Seung-Gie;Park, Tae-Young;Kim, Bong-Sang;Park, Duck-Shin;Kwon, Soon-Bark
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1293-1296
    • /
    • 2007
  • An amenity requirement of the passenger using public traffic is rising continuously, and also The Ministry of Environment established "Indoor air quality management guidelines in public facilities(Dec. 2006)". To satisfy such requirement, the photoplasma device to decrease VOCs(Volatile Organic Compounds) and suspended bacillus is applied to the underframe mounted HVAC(Heating, Ventilating and Air-Conditioning) system for train. Air purifying method of photoplasma device is optical and chemical reaction that UV-light(wavelength less than 280nm) react with catalyst material(TiO2). To analyze the efficiency of photoplasma in this study, we measured the requirement time for toluene to decease down to 0.3ppm after contaminating the passenger cabin for train to toluene 1ppm.

  • PDF

Noise Reduction of HVAC Equipment for High Speed Train Operating at 200km/h (시속 200km급 고속철도차량의 공조시스템 소음저감기술개발)

  • 박철희;이우식;주재만;김주홍
    • Proceedings of the KSR Conference
    • /
    • 1998.05a
    • /
    • pp.273-279
    • /
    • 1998
  • This study represents the technique about the noise reduction of HVAC equipment for high speed train(HST) operating at 200km/h. HST is different from the low speed train in the various points as well as the speed. Especially, the noise of cabin is closely related to the comfort of passenger and the noise from HVAC is one of main noise source in the cabin. In this study, the noise from HVAC was reduced by 5 dB(A) using the concept of multiple resonator and guide vein. Therefore, the noise of cabin decreased from 60 dB(A) to 55 dB(A) at the center of the cabin.

  • PDF

A Numerical Study on Automobile Interior Environment (자동차 실내 환경에 관한 수치적 연구)

  • Jeon, Hee-Ho;Ko, Seok-Bo;Lee, Kum-Bae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.1
    • /
    • pp.36-42
    • /
    • 2007
  • The latest cars give much importance in the role of HVAC system that controls the environment of the area for passengers more than just basic capability In this study, we drew the automobile interior as three dimension and arranged a method of numerical analysis on HVAC environment in the automobile interior displaying air current distribution and temperature distribution through simulation of the automobile interior on the ventilation volume and outlet area, The aim of this study is to develop the estimated method for HVAC environment in the automobile interior. Results of numerical analysis, to cool automobile interior needs more considerations if thinking cheerful surroundings of automobile interior air but the more magnitude of outlet is small, the more cooling capability is excellent and realistic countermeasures about a realistic geometry and boundary condition.

Characteristics of noise in HVAC duct for vehicle (차량용 공조덕트의 소음특성에 관한 연구)

  • Kim, Jae-Won;Kim, Jin-Min;Park, Jeong-Young
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.529-534
    • /
    • 2003
  • Comprehensive study on the system, including blower and ducts, of HVAC device of a vehicle has been carried out for improvements of noise characteristics. The parameters of design improvements are concerned with geometric informations such as the shape of ducts and presence of a windshield window. Test results show that noise level increasing the following order: HV (HD) < V (D) < BH ${\sim}$ BHV (BHD) < B (B, H, V, D denote for blower, heater unit, vent duct, defrost duct, respectively). The effects of windshield glass on the noise level in the case of defrost mode are pronounced and the effects of the geometry of ducts on the overall HVAC noise prove to be not small.

  • PDF

Economic Analysis of Voltage Source Converter(VSC) HVDC Technologies - HVAC, LCC-HVDC, VSC-HVDC (focusing on CIGRE WG-B4.46 492 Report) - (VSC-HVDC 적용 기술의 경제성 평가 분석 - HVAC, LCC-HVDC, VSC-HVDC (CIGRE WG-B4.46 492 Report를 중심으로) -)

  • Yeo, Seo-Hyun;Seon, Hwi-il;Kim, Sun-Pil;Park, Seong-mi;Yoo, Dong-Wook;Park, Sung-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.982-983
    • /
    • 2015
  • 본 논문은 CIGRE 492 보고서를 따른 것으로 최근 해외 선도 기업 및 미국, 유럽, 중국 등에서 도입하고 있는 LCC-HVDC, VSC-HVDC와 기존 송전시스템인 HVAC의 기술 및 경제적 효율성을 비교분석하였다. 분석 방법은 동일한 조건을 설정하여 각 시스템에 모의 적용하였으며, (1) HVAC와 VSC-HVDC와의 비교 (2) LCC-HVDC와 VSC-HVDC와의 비교를 진행하였다. 그 결과 시간 흐름에 따라 AC보다 DC에서의 경제적 효율성을 확인하였고, 또한 HVDC의 전류형과 전압형의 비용 분석에서는 오차범위, 추가적 편익 등을 고려할 시 전압형의 경제성에 대한 긍정적 측면을 확인할 수 있었다. 본 연구에서는 일반적인 PWM 방식을 택하였으나, 추후 연구에서는 최근 선도 기술이라 평가받는 MMC 방식의 전압형 HVDC를 적용하여 연구하고자 한다.

  • PDF

Analysis of a Mount Type HVAC Control System Using Axiomatic Design (공리적 설계를 이용한 매립형 공기조화시스템의 분석)

  • Lee, Se-Jung;Hong, Eul-Pyo;Kim, Dae-Whan;Kim, Su-Ok;Park, Gyung-Jin
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1028-1033
    • /
    • 2008
  • The mount type HVAC control system is a type of an HVAC control system which is installed between a ceiling and ceiling boards of a room to control room temperature. Although the device is quite popular, design is conducted by a conventional way where engineering intuition and experiences are utilized. It is found that the design process is fairly inefficient and time-consuming because there are a lot of feedbacks. The axiomatic approach is used to investigate the design characteristics of the mount type HAVC control system and the Independence Axiom is utilized for the investigation. The Overall hierarchy is established up to the level of parts. It is found that the current design has many coupled and redundant aspects. The hierarchy is reorganized based on the Independence Axiom and a new design process is found. To exploit the new design process in practice, a design manual is made.

  • PDF

A Numerical Study for Performance of Automotive HVAC System (전산해석에 의한 자동차용 HVAC 시스템의 성능 연구)

  • Lee Dae-Woong;Yoo Seong-Yeon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.11
    • /
    • pp.1084-1091
    • /
    • 2004
  • In automotive air handling system, mixing of air streams by the cooler and the heater affects the comfort of cabin room. In the present study, computer-aided analysis is done to improve the thermal comfort and for the optimal design of automotive HVAC system. The simulation software used was FLUENT, and complicate geometries were created by three dimensional CAD. Air flow volume, fir distribution rate and temperature controllability and temperature differences between upper and lower discharge air are analyzed through numerical simulation at vent, floor and defrost mode. Also, velocity vector of sirocco fan is investigated through the scroll housing. The velocity vector magnitude is larger at lower region of fan than that at any other regions. Recirculation and disturbance of air is relatively high near the cut-off edge in the scroll housing. By using the results of this study, the time for prototype production can be reduced and timely decisions can be made to determine initial design directions.

An Experimental Study on Multi-Fault Detection and Diagnosis Analysis of HVAC System (HVAC 시스템의 중복고장 검출을 위한 실험적 연구)

  • Cho Sung-Hwan;Hong Young-Ju;Yang Hooncheul;Ahn Byung-Cheon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.10
    • /
    • pp.932-941
    • /
    • 2004
  • The objective of this study is to detect the multi-fault of HVAC system using a new pattern classification technique. To classify the effect of single-fault in determining the pattern, supply air temperature, OA-damper, supply fan, and air flowrate were chosen as experimental parameters. The combination of supply temperature, flow rate, supply fan and OA-damper were chosen as multi-fault conditions. Three kinds of patterns were introduced in the analysis of multi-fault problem. To solve multi-fault problem, the new pattern classification technique using residual ratio analysis was introduced to detect the multi-fault as well as single-fault. The residual ratio could diagnose single-fault or multi-fault into several patterns.

Development of Robust Intelligent Digital Controller for Smart Space (스마트 스페이스 구축을 위한 강인 지능형 디지털 제어기 개발)

  • Joo, Young-Hoon
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.18 no.1
    • /
    • pp.60-65
    • /
    • 2008
  • In this paper, we concern the stability of smart space by using the robust digital controller. The proposed methodologies are based on the intelligent digital redesign (IDR). More precisely, we represent the nonlinear and uncertain analog system as the Takaki-Sugeno (T-S) fuzzy model. Then the IDR problem can be reduced to find the digital gains minimizing the norm distance between the closed-loop states of the analog and digital control. Its constructive conditions are expressed as the linear matrix inequalities (LMIs). At last, a numerical example, HVAC system, is demonstrated to visualize the feasibility of the proposed methodology.

The On-Line Diagnostic Test of Fault Diagnosis System for Air Handling Unit (공조설비용 고장진단시스템의 실시간 진단실험)

  • 소정훈;유승신;경남호;신기석
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.8
    • /
    • pp.787-795
    • /
    • 2001
  • An experimentation on the on-line fault detection and diagnosis(FDD) system has been performed with HVAC system in he experimental building constructed inside the large scale environmental chamber. Personal computer with a home-made FDD program by pattern recognition method utilizing artificial neural network was connected on-line via Ether-net TCP/IP to the supervisory control server for HVAC system. The FDD program monitored the HVAC system by 1 minuted interval. The results showed that he FDD program detected the sudden or abrupt faults such s those in fans, sensors and heater, etc.

  • PDF