• 제목/요약/키워드: HTS SQUID

검색결과 23건 처리시간 0.026초

비자기차폐환경에서 미세 자기장 측정을 위한 고온초전도 gradiometer 시스템의 개발 (Development of a HTS SQUID gradiometer system for the measurement of very weak magnetic field in an unshielded environment)

  • 김인선;김진목;박용기
    • 한국초전도학회:학술대회논문집
    • /
    • 한국초전도학회 2000년도 High Temperature Superconductivity Vol.X
    • /
    • pp.151-154
    • /
    • 2000
  • We have developed a YBCO SQUID gradiometer system for the measurement of a very weak magnetic field in an unshielded environment. The system consists of a SQUID gradiometer sensor, low noise pre-amp, and FLL(fluxlocked loop) control electronics. The gradiometer sensors have been fabricated on STO bicrystal substrates, and exhibit a magnetic noise of 300 fT/${\surd}$ Hz/cm at 100 Hz. The overall magnetic field noise of the SQUID gradiometer system was about 10 pT/${\surd}$ Hz/cm at 10 Hz without any magnetic shield. The system demonstrated a high stability for a long time, and real-time measurement resolution ${\le}$ 100 pT/cm in the unshielded environments.

  • PDF

심자도 측정용 고온초전도 SQUID magnetometer의 제작 (Fabrication of a HTS SQUID Magnetometer for Magnetocardiogram)

  • 김인선;이상길;김진목;권혁찬;이용호;박용기;박종철
    • 센서학회지
    • /
    • 제6권4호
    • /
    • pp.258-264
    • /
    • 1997
  • $YBa_{2}Cu_{3}O_{7}$ 단일층 박막으로 된 직접결합형 직류 SQUID magnetometer를 설계하여 $SrTiO_{3}$기판위에 제작하였다. 검출코일은 외변 8.5 mm, 선폭은 2.6 mm로 하였으며, 조셉슨 접합의 선폭은 $3\;{\mu}m$, SQUID 인덕턴스는 50pH로 하였다. 제작된 소자의 외부 자속에 대한 전압 변조신호의 크기는 최대 $65\;{\mu}V$, 자장잡음은 1 Hz에서 약0.6 pT/$\sqrt{Hz}$ 이었다. 이 SQUID magnetometer를 사용하여 자기차폐실 내에서 심자도 파형을 측정하여 가산평균하였을 때 매우 양호한 심자도 파형을 얻을 수 있었다.

  • PDF

Construction of HTS multi-channel SQUID system

  • Park, W.K.;Lee, H.J.;Moon, S.H.;Lim, S.H.;Kim, D.Y.;Oh, B.;Lee, S.M.
    • 한국초전도학회:학술대회논문집
    • /
    • 한국초전도학회 2000년도 High Temperature Superconductivity Vol.X
    • /
    • pp.169-172
    • /
    • 2000
  • We have constructed a multi-channel SQUID magnetometer system. The system is designed to operate normally with 10 high temperature direct coupled SQUIDs. The main features of the system include a remote control by serial communication, low noise with wide bandwidth and high slew rate by several MHz modulation, signal conditioning and calibration by digital signal processing.

  • PDF

변화하는 자기장 하에 있는 고온초전도체에 대한 유한요소법을 이용한 2차원 수치해석 연구 (2-Dimensional Numerical Studies on Thin HTS Film under Time Varying Magnetic Field Using Finite Element Method)

  • 곽기성;이효연;이준규;염도준;유재은;한영희;박병준
    • Progress in Superconductivity
    • /
    • 제13권3호
    • /
    • pp.151-157
    • /
    • 2012
  • In this paper, we used E-J constitutive law and H-formulation to calculate magnetic field profile, current density, and magnetization of high temperature superconductor (HTS) placed in time varying applied magnetic field. Finite element method (FEM)-based software, Comsol Multiphysics 3.5a, was employed to simulate 2-dimensional model of a superconducting thin strip. The numerical results based on Kim's critical state model were compared with the case of strip in a perpendicular field in the Brandt's paper as well as experimental data observed by Scanning Hall Probe and SQUID.

증류수 계면처리를 이용한 고온초전도체 죠셉슨 접합 제작 (HTS Josephson Junctions with Deionized Water Treated Interface)

  • 문승현;박완규;계정일;박주도;오병두
    • Progress in Superconductivity
    • /
    • 제2권2호
    • /
    • pp.76-80
    • /
    • 2001
  • We have fabricated YBa$_2$Cu$_3$$O_{7-x}$ (YBCO) ramp-edge Josephson junctions by modifying ramp edges of the base electrodes without depositing any artificial barrier layer. YBa$_2$Cu$_3$O/7-x//SrTiO$_3$ (YBCO/STO) films were deposited on SrTiO$_3$(100) by on-axis KrF laser deposition. After patterning the bottom YBCO/STO layer, the ramp edge was cleaned by ion-beam and then reacted with deionized water under various conditions prior to the deposition of counter-electrode layers. The top YBCO/STO layer was deposited and patterned by photolithography and ion milling. We measured current-voltage (I-V) characteristics, magnetic field modulation of the critical current at 77 K. Some showed resistively shunted junction (RSJ)-type I-V characteristics, while others exhibited flux-flow behaviors, depending on the dipping time of the ramp edge in deionized water. Junctions fabricated using optimized conditions showed fairly uniform distribution of junction parameters such as I$_{c}$R$_{n}$ values, which were about 0.16 mV at 77 K with 1$\sigma$~ 24%. We made a dc SQUID with the same deionized water treated junctions, and it showed the sinusoidal modulation under applied magnetic field at 77 K. 77 K.

  • PDF

A Single-Flux-Quantum Shift Register based on High-T$_c$ Superconducting Step-edge Josephson Junctions

  • Sung, G.Y.;Choi, C.H.;Suh, J.D.;Han, S.K.;Kang, K.Y.;Hwang, J.S.;Yoon, S.G.;Jung, K.R.;Lee, Y.H.;Kang, J.H.;Kim, Y.H.;Hahn, T.S.
    • 한국초전도학회:학술대회논문집
    • /
    • 한국초전도학회 1999년도 High Temperature Superconductivity Vol.IX
    • /
    • pp.133-133
    • /
    • 1999
  • We have fabricated and tested a simple circuit of the rapid single-flux-quantum(RSFQ) four-stage shift register using a single layer high-T$_c$ superconducting (HTS) YBa$_2Cu_3O_{7-x}$ (YBCO) thin film structure with 9 step-edge Josephson junctions. The circuit includes two read superconducting quantum interference devices(SQUID) and four stages. To establish a robust HTS RSFQ device fabrication process, we have focussed the reproducible process of sharp and straight step-edge formation as well as the ratio of film thickness to step height t/h. The spread of step-edge junction parameters was measured from each13 junctions with t/h=l/3, l/2, and 2/3 at various temperatures. We have demonstrated the simplified operation of the shift register at 65 K..

  • PDF