• 제목/요약/키워드: HTS (High Temperature Superconductor)

검색결과 178건 처리시간 0.026초

22 GHz 초전도 필터의 주파수 응답 특성 분석 (Frequency Response of Superconducting Filter with Center Frequency 22 GHz)

  • 김철수;송석천;이상렬
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.794-797
    • /
    • 2000
  • The fabrication of high quality superconducting thin films using pulsed laser deposition (PLD) has been reported to find optimized processing conditions and to make the millimeter-wave devices. High temperature superconducting (HTS) YBCO films were prepared on MgO (10${\times}$10${\times}$0.5mm) substrates by the PLD. The 3 pole bandpass filter with the center frequency of 22 GHz for satellite communication was designed consisting of hairpin coupled-lines to reduce the configuration in size. YBCO films are c-axis oriented and show superconductive transition temperatures of 88∼89 K with the transition widths < 0.5 K. The insertion loss of passband at 70 K was about 5 dB. The measured frequency response of superconducting filter will be compared with the simulation result.

  • PDF

Design of closed-loop nitrogen Joule-Thomson refrigeration cycle for 67 K with sub-atmospheric device

  • Lee, C.;Lee, J.;Jeong, S.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제15권1호
    • /
    • pp.45-50
    • /
    • 2013
  • Closed-loop J-T (Joule-Thomson) refrigeration cycle is advantageous compared to common open loop $N_2$ decompression system in terms of nitrogen consumption. In this study, two closed-loop pure $N_2$ J-T refrigeration systems with sub-atmospheric device for cooling High Temperature Superconductor (HTS) power cable are investigated. J-T cooling systems include 2-stage compressor, 2-stage precooling cycle, J-T valve and a cold compressor or an auxiliary vacuum pump at the room temperature. The cold compressor and the vacuum pump are installed after the J-T valve to create sub-atmospheric condition. The temperature of 67 K is possible by lowering the pressure up to 24 kPa at the cold part. The optimized hydrocarbon mixed refrigerant (MR) J-T system is applied for precooling stage. The cold head of precooling MR J-T have the temperature from 120 K to 150 K. The various characteristics of cold compressor are invstigated and applied to design parameter of the cold compressor. The Carnot efficiency of cold compressor system is calculated as 16.7% and that of vacuum pump system as 16.4%. The efficiency difference between the cold compressor system and the vacuum pump system is due to difference of enthalpy change at cryogenic temperature, enthalpy change at room temperature and different work load at the pre-cooling cycle. The efficiency of neon-nitrogen MR J-T system is also presented for comparison with the sub-atmospheric devices. These systems have several pros and cons in comparison to typical MR J-T systems such as vacuum line maintainability, system's COP and etc. In this paper, the detailed design of the subcooled $N_2$ J-T systems are examined and some practical issues of the sub-atmospheric devices are discussed.

Feasible waste liquid treatment from electroless nickel-plating by intense magnetic field of HTS bulk magnets

  • Oka, T.;Furusawa, M.;Sudo, K.;Dadiel, L.;Sakai, N.;Seki, H.;Miryala, M.;Murakami, M.;Nakano, T.;Ooizumi, M.;Yokoyama, K.;Tsujimura, M.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제23권3호
    • /
    • pp.37-40
    • /
    • 2021
  • Nickel (Ni) is a kind of the rare earth resources. Since Ni-containing waste is drained after several plating operations in the factories, the effective recycling technique has been expected to be introduced. An actual magnetic separation technique using HTS bulk magnet generating the strong magnetic field has succeeded in collecting the paramagnetic slurry containing Ni-sulphate coarse crystals which were fabricated from the Ni-plating waste. The Ni compound in the collected slurry was identified as NiSO4/6H2O, showing slight differences in the particle size and magnetic susceptibility between the samples attracted and not-attract to the magnetic pole. This preferential extraction suggests us a novel recycling method of Ni resource because the compound is capable of recycling back to the plating processes as a raw material.

Development and performance evaluation of a cryogenic blower for HTS magnets

  • Kwon, Yonghyun;Mun, Jeongmin;Lee, Jaehwan;Seo, Geonghang;Kim, Dongmin;Lee, Changhyeong;Sim, Kideok;Kim, Seokho
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제22권4호
    • /
    • pp.57-61
    • /
    • 2020
  • Cooling by gas helium circulation can be used for various HTS (high temperature superconductor) magnets operating at 20~40 K, and a cryogenic blower is an essential device for circulating gas helium in the cooling system. The performance of the cryogenic blower is determined by various design parameters such as the impeller diameter, the blade number, the vane angle, the volute cross-sectional area, and the rotating speed. The trailing edge angle and the height of impeller vane are also key design factors in determining the blower performance. This study describes the design, fabrication and performance evaluation of cryogenic blower to produce a flow rate of 30 g/s at 5 bar, 35 K gas helium. The impeller shape is designed using a specific speed/specific diameter diagram and CFD analysis. After the fabrication of the cryogenic blower, a test equipment is also developed using a GM cryocooler. The measured flow rates and the pressure differences are compared with the design values at various rotating speeds and the results show a good agreement. Isentropic efficiency is also evaluated using the measured pressures and temperatures.

주위온도조건이 스터링 극저온냉동기의 성능에 미치는 영향 (Effects of the environmental temperature on the performance of the Stirling cryocooler)

  • 홍용주;김효봉;박성제
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제11권3호
    • /
    • pp.65-68
    • /
    • 2009
  • The Stirling cryocoolers have been widely used for the cooling of the infrared detector(InSb, HgCdTe, and etc,) and HTS(High Temperature Superconductor) to the cryogenic temperature. The monobloc Stirling cryocoolers with the rotary compressor are applicable to the cooling device for the compact mobile thermal imaging system, because the cryocoolers have the compact structure and light weight. The typical performance factors of the Stirling cryocooler are the cool-down time, cooling capacity at the desired temperature (80 K), the electric input power and COP. The above performance factors depend on the operating conditions such as the charging pressure of the helium gas, the thermal environment and etc.. In this study, the effects of the thermal environment (temperature of 241, 293, and 333 K) on the performance of the cryocooler were investigated by experiments. The results show the effects of the temperature of the thermal environment on the cooling capacity and input power.

고온 초전도체를 이용한 협대역 대역통과 여파기 설계 (A Design of Narrowband Bandpass Filter using High-Temperature Superconductor)

  • 윤형국;윤영중;김성민;이상렬
    • 한국통신학회논문지
    • /
    • 제24권9B호
    • /
    • pp.1668-1675
    • /
    • 1999
  • 본 논문에서는 위성통신용 멀티플렉서에 사용 가능한 협대역 대역통과 여파기를 설계하기 위해 협대역 특성을 가지며 삽입 손실 및 소자의 크기를 최소화시킬 수 있는 고온 초전도체를 이용하여 hairpin-line 및 hybrid hairpin-line/parallel-coupled-line 여파기를 설계하고 실험을 통해 그 특성을 고찰하였다. Hairpin-line만으로 설계된 대역통과 여파기는 surface wave에 의한 spurious mode가 발생한다는 단점이 있지만 본 논문에서 제안된 hybrid hairpin-line/parallel-coupled-line 여파기를 사용하여 spurious mode를 줄일 수 있다. 동작 주파수가 14.25 GHz인 협대역 대역통과 여파기는 고온 초전도체를 이용하여 동일한 3극에서 일반금속 마이크로스트립 여파기보다 더 좋은 1%미만의 협대역과 3 dB이상 적은 삽입손실을 갖도록 하였으며 따라서 같은 성능을 보이고자 할 때 그 크기를 최소화시킬 수 있도록 설계하였다.

  • PDF

초전도 한류기를 이용한 Bi-2223/Ag 선재의 퀜치 보호를 위한 기초 연구 (Preliminary study on the quench protection of Bi-22231 Ag tape using superconducting fault current limiter)

  • 두호익;임성우;현옥배;황시돌;조철용;박충렬;한영성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.243-244
    • /
    • 2006
  • As an preliminary study for the quench protection of high temperature superconducting (HTS) cable using superconducting fault current limiter (SFCL), experimental research was carried out. The test circuit was composed of Bi-2223/Ag HTS tape and a SFCL made of YBCO thin films. In the normal state, the applied current of 56 A, which was critical current of HTS tape, could be flown through the circuit without resistive loss. Increasing the currents, the quench development of both materials was investigated from the voltage signal acquired from the resistance of the quenched superconductor. Up to around 10 times of the critical current was applied to the HTS tape and the current limiting characteristics of SFCL were investigated. In addition, for the finding out the optimal operating condition of SFCL such as the numbers of elements, a shunt resistor was applied to the SFCL and quench characteristics were analyzed as well.

  • PDF

공정변수에 따른 초전도 튜브의 전기적 특성변화

  • 박치완;장건익;하동우;성태현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 추계학술대회 논문집 Vol.17
    • /
    • pp.73-76
    • /
    • 2004
  • High-temperature Superconductor(HTS) tubes were fabricated in term of different processing variables such as preheating temperature, speed of mold rotation and cooling rate by centrifugal forming method. For powder melting by induction the optimum range of melting temperatures and preheating temperature were $1050^{\circ}C{\sim}1100^{\circ}C$ and $550^{\circ}C$ for 30min, respectively. The mould roating speed was 1000rpm. A tube was annealed at $840^{\circ}C$ for 72hours in oxygen atmosphere. The plate-like grains were well developed along the roating direction and typical grain size was about more than $40{\mu}m$. It was found that Ic values increased with increasing the preheating temperature and speed of mold rotation. While Ic decreased with increasing the cooling rate. The measured Ic in $50mm{\times}70mm{\times}2.5mm$ tube was about 896Amp.

  • PDF

공정변수에 따른 초전도 튜브의 전기적 특성 (Electrical Characteristics of HIS Tube Depending on Processing Parameters)

  • 박치완;장건익;하동우;성태현
    • 한국전기전자재료학회논문지
    • /
    • 제18권5호
    • /
    • pp.468-472
    • /
    • 2005
  • High-temperature Superconductor(HTS) tubes were fabricated in term of different processing variables such as preheating temperature, speed of mold rotation and cooling rate by centrigugal forming method. For powder melting by induction the optimum range of melting temperatures and preheating temperature were $1050{\circ}C{\sim}1100{\circ}C\;and\;550{\circ}C\;for\;30\; min$, respectively The mould roating speed was 1000 rpm. A tube was annealed at $840 {\circ}C$ for 72 hours in oxygen atmosphere. The plate-like grains were well developed along the loafing direction and typical grain size was about more than $40{\mu}$. It was found that Ic values increased with increasing the Preheating temperature and speed of mold rotation. While Ic decreased with increasing the cooling rate. The measured Ic in $50mm{\times}70mm{\times}2.5mm$ tube was about 896 Amp.

레이저 공정을 이용한 고온초전도 멀티플렉서의 제작과 특성 분석 (Investigation of Characterization and Fabrication High-Temperature Superconducting Multiplexer by Pulse laser Deposition)

  • 김철수;송석천;이상렬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 D
    • /
    • pp.1858-1860
    • /
    • 1999
  • To fabricate superconducting multiplexers with narrow pass band characteristics and reduce the physical size of device, we have designed multiplexer using hair-pin type filters with the center frequency of 13.6 GHz. Multiplexers have been fabricated superconductor(HTS), because It has low surface resistance. The $YBa_2Cu_3O_{7-{\delta}}$(YBCO) films were deposited on MgO substrates$(20{\times}20{\times}0.5mm^3)$ by using pulsed laser deposition and conventional photo-lithographic methods were used to pattern the multiplexer. Epitaxial YBCO films were grown on(100) MgO substrates and showed strongly c_axis orientations observed by X-ray diffraction technique. Superconducting transition temperatures were measured to be about 89K. Simulated results of superconducting multiplexer consisting of hair-pin type filters show the insertion loss of about 1.2dB. The measured frequency response will be compared with the simulated results.

  • PDF