• 제목/요약/키워드: HTC

검색결과 84건 처리시간 0.02초

Research on improving efficiency in VR game development

  • Kim Tae Gyu
    • International Journal of Advanced Culture Technology
    • /
    • 제11권4호
    • /
    • pp.74-80
    • /
    • 2023
  • Currently, hardware companies such as Oculus, Samsung, and HTC are producing virtual reality devices, and game software development companies are developing or servicing VR games using these devices. Accordingly, the VR game market is expected to continue to grow in the future. However, in order for the VR game market to become active, various problems raised during game development and service must be resolved. This paper investigates solutions to problems raised during the development and service of VR games, such as cyber sickness, risk of injury due to environmental restrictions during play, and reconnection induction problems. Cybersickness can be alleviated by utilizing multiple GPUs for each display processing to achieve higher frame rates and optimizing play space design. Environmental constraints during play can be mitigated by optimizing space design, and the problem of inducing reconnection can be solved by continuously providing the motivation and purpose used in existing game methods. Through this, we were able to apply it to develop VR content that can be played continuously.

몰입형 에이전트의 사실적인 수중환경 인지를 위한 가상현실 프레임워크 (Virtual Reality Framework for Realistic Underwater Environment Perception of Immersive Agents)

  • 홍성훈;김종현
    • 한국컴퓨터정보학회:학술대회논문집
    • /
    • 한국컴퓨터정보학회 2024년도 제69차 동계학술대회논문집 32권1호
    • /
    • pp.391-393
    • /
    • 2024
  • 본 논문에서는 수중에 존재하는 몰입형 에이전트의 움직임을 사실적으로 표현하고 수중 오브젝트들과의 상호작용에서 나타나는 외력을 시각적으로 표현할 수 있는 프레임워크를 제안한다. Unity3D와 HTC Vive를 이용해 사용자의 움직임을 추적하고 수중 물리적 요소인 부력, 저항력, 매그너스 효과를 몰입형 에이전트에 적용시켜 사용자로 하여금 수중에 작용하는 외력을 사실적으로 인지할 수 있게 한다.

  • PDF

계산 과학 응용을 위한 과학 워크플로우 통합 수행 환경 설계 (A Design of Integrated Scientific Workflow Execution Environment for A Computational Scientific Application)

  • 김서영;윤경아;김윤희
    • 인터넷정보학회논문지
    • /
    • 제13권1호
    • /
    • pp.37-44
    • /
    • 2012
  • 빠르게 발전하는 컴퓨팅 기술에 비례해서 컴퓨팅 기기의 이용이 더욱 편리해짐에 따라 계산과학 분야의 연구자들은 점점 더 컴퓨팅 기술에 의존하고 있으며 더욱 계산 집약적인 연구를 진행하고 있다. 이러한 계산 과학 연구자들의 연구 환경 지원을 위하여 전 세계적으로 e-사이언스 환경에 대한 연구가 활발하게 진행되고 있으며, 여전히 연구자의 실험 환경과 컴퓨팅 자원간의 별도의 설정과 설치 과정이 필요 없는 자유로운 연구 환경에 대한 보장이 요구되고 있다. 본 논문에서는 계산과학 분야의 연구자들의 실험 환경을 분산된 고성능 컴퓨팅 인프라와 함께 웹 브라우저를 통해 쉽게 접근 가능한 과학 워크플로우 통합 수행 환경을 제시한다. 이 환경에서는 워크플로우 설계 툴을 통해 정의된 순서와 작업 특성을 고려하여 분산된 그리드 자원에 제출함으로써 작업들에 대한 자동화된 수행을 제공한다. 포탈을 통해 제공되는 워크플로우 설계 툴은 사용이 용이한 인터페이스를 제공하며 실시간으로 워크플로우의 실행 상태를 모니터링 서비스를 통해 제공한다. 사용자는 워크플로우의 실행에서의 중간 결과를 확인하고 수행의 흐름을 결정할 수 있다. 이로써 복잡한 HTC 기반의 실험 수행을 효과적으로 진행할 수 있으며 연구의 생산성을 높일 수 있다.

도시철도시설 성능평가 시뮬레이션 구현을 위한 기초 연구 (Preliminary Study on the Simulation for Urban Railway Facility Performance Assessment)

  • 강고운;정인수;김정렬;서명배
    • 한국산학기술학회논문지
    • /
    • 제21권3호
    • /
    • pp.190-198
    • /
    • 2020
  • 노후화율이 19.7%인 국내 도시철도에 대한 개량투자계획을 수립하기 위해서는 성능평가가 선행되어야 한다. 최근 관련법에서 제정된 성능평가는 데이터 획득 및 평가에 소요되는 시간 및 노력이 과다하다고 지적되고 있다. 이에 본 연구는 철도시설의 성능평가를 위한 교육용 컨텐츠로 활용하기 위하여 가상현실(VR) 기법을 적용한 성능평가 시뮬레이션 프로토타입을 개발하였다. 이를 위해 기존연구 고찰을 통해 어려운 환경에서의 작업시간 단축을 위한 VR기법의 활용성을 확인하였다. 도시철도 전문가들을 대상으로 계층화분석법 설문조사 및 자문을 실시하였으며, 결과를 분석하여 성능평가 항목 및 도시철도 시설분류체계의 가중치를 확정하고 시뮬레이션을 위한 평가시트를 개발하였다. 평가시트를 기반으로 VR 기법을 이용하여 승강장 안전문의 성능을 평가하는 교육 컨텐츠 프로로타입을 개발하였다. 시스템은 HTC VIVE 장비로 구현하였으며, 6명의 플레이어를 대상으로 VR 시뮬레이션 테스트를 진행하였다. 개발된 프로토타입은 평가대상 시설물 정보의 시각적 확인에 충분히 장점이 있는 것으로 분석되었다. 본 연구의 결과는 향후 도시철도시설의 성능평가시 엔지니어가 실제 평가에 앞서 평가절차를 효율적으로 숙지하는데 도움을 줄 것으로 사료된다.

세관을 사용한 응축기에서 R-22의 대체냉매인 R-410A의 응축 열전달 특성 (Condensation Heat Transfer Characteristics of R-410A as an Alternative R-22 in the Condenser with Small Diameter Tubes)

  • 손창효
    • 청정기술
    • /
    • 제13권2호
    • /
    • pp.151-158
    • /
    • 2007
  • 프레온계 냉매의 지구온난화와 오존층파괴 문제로 인해 대체냉매로서 R-410A가 주목을 받고 있다. 이러한 대체냉매를 세관에 적용시킬 경우 효율을 향상시킬 뿐만 아니라 지구환경에 미치는 영향을 감소시키고, 대기를 청정하게 만드는 기술 및 방안으로 각광 받고 있다. 따라서 본 연구에서는 R-22의 대체냉매로 각광받고 있는 R-410A의 세관응축기 내에서의 응축열전달 특성에 대해 실험적으로 고찰하고자 하였다. 실험장치는 유동양식, 열전달, 압력강하 특성을 파악할 수 있도록 제작되었고, 주요 구성품은 냉매펌프, 증발기, 응축기(시험부), 사이트 글라스(가시화부), 압력탭, 측정장치 등이다. 시험부의 내관은 내경 3.36 mm와 5.35 mm인 수평평활 동관이다. 실험변수들의 범위로서 질량유속 $200{\sim}500\;kg/m^2s$이고, 열유속은 $1.0{\sim}2.4\;kW$이다. R-410A의 응축열전달 계수가 R-22에 비해 최대 5% 정도 높은 것을 알 수 있었다. 세관 내 R-410A와 R-22의 유동양식은 환상류 영역이 지배적으로 나타남을 관찰하였고, 건도가 0.2 이하인 영역에서는 성층류가 나타남을 확인할 수 있었다. 내경 3.36 mm의 압력강하가 내경 5.35 mm에 비해 $30{\sim}50%$정도 높았다. 종래의 응축 열전달 상관식과 실험데이터를 비교한 결과, Fujii의 상관식과 최대 40%이내에서 일치하였다.

  • PDF

A Decision Support Model for Financial Performance Evaluation of Listed Companies in The Vietnamese Retailing Industry

  • NGUYEN, Phi-Hung;TSAI, Jung-Fa;NGUYEN, Viet-Trang;VU, Dang-Duong;DAO, Trong- Khoi
    • The Journal of Asian Finance, Economics and Business
    • /
    • 제7권12호
    • /
    • pp.1005-1015
    • /
    • 2020
  • This paper aims to propose a Comprehensive Decision Support Model to evaluate retail companies' financial performance traded on the Vietnam Stock Exchange Market. The financial performance has been examined in terms of the valuations ratios, profitability ratios, growth rates, liquidity ratios, efficiency ratios, and leverage ratios. The data of twelve companies from the first quarter to the fourth quarter of 2019 and the first quarter of 2020 were employed. The weights of 18 chosen financial ratios are calculated by using the Standard Deviation method (SD). Grey Relational Analysis technique was applied to obtain the final ranking of each company in each quarter. The results showed that leverage ratios have the most significant impact on the retail companies' financial performance and gives some long-term investment recommendations for stakeholders and indicated that the Taseco Air Services Joint Stock Company (AST), Mobile World Investment Corporation (MWG), and Cam Ranh International Airport Services Joint Stock Company (CIA) are three of the top efficient companies. The three of the worst companies are Viglacera Corporation (VGC), Saigon General Service Corporation (SVC), and HocMon Trade Joint Stock Company (HTC). Furthermore, this study suggests that the GRA model could be implemented effectively to ranking companies of other industries in the future research.

Heat Transfer Correlation during Gas-Cooling Process of Carbon Dioxide in a Horizontal Tube

  • Kang Byung-Ha;Choi Yi-Cheol;Kim Suk-Hyun
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제14권1호
    • /
    • pp.19-27
    • /
    • 2006
  • The characteristics of heat transfer and pressure drop have been investigated experimentally during gas-cooling process of carbon dioxide. The results of this study are useful information in the design of a heat exchanger of $CO_2$ refrigerator. The test section consists of 6 series of copper tube, 4.15 and 2.18mm ID, respectively. The inlet temperature, the operating pressure, and the mass flux are varied in the range of $80{\sim}120^{\circ}C,\;{7\sim}10MPa,\;and\;400{\sim}1,900kg/m^2s$, respectively. The heat transfer coefficient of $CO_2$ is affected by temperature, inlet pressure, and mass flux of $CO_2$. At the maximum HTC, the temperature of $CO_2$ nearly accords with the psuedocritical temperature. It is found that the pressure drop is substantially affected by mass flux and inlet pressure of $CO_2$ . The results have been compared with those of previous work. The heat transfer correlation at the gas-cooling process has been also suggested which predicts within the error of 20%.

하수슬러지의 Biochar특성을 이용한 토양내 중금속 제거 연구 (A Study on the Removal of Heavy Metals in Soil by Sewage Sludge Biochar)

  • 김혜원;배선영;이재영
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제18권3호
    • /
    • pp.58-64
    • /
    • 2013
  • This study proposed a low temperature hydrothermal carbonization to treat and recycle sewage sludge and determined the optimal conditions for the biochar production. The physical and chemical properties of biochar were analyzed and its sorption capacity for heavy metals was evaluated. To produce biochar, 50 g of sewage sludge was heated at 220, 230, and $240^{\circ}C$ for 1, 2, 3, 5, 8, and 10 hours in a reactor. The optimal conditions to produce biochar was $230^{\circ}C$ and 8 hours. Sorption capacity tests were conducted for arsenic (As), cadmium (Cd), copper (Cu), lead (Pb), zinc (Zn) and nickel (Ni). Among them, lead was shown the highest heavy metal adsorption efficiency of biochar, followed by copper, cadmium, zinc, and nickel, but arsenic was hardly adsorbed overall.

Joint Resource Allocation Scheme for OFDM Wireless-Powered Cooperative Communication Networks

  • Liang, Guangjun;Zhu, Qi;Xin, Jianfang;Pan, Ziyu
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제11권3호
    • /
    • pp.1357-1372
    • /
    • 2017
  • Energy harvesting techniques, particularly radio frequency energy harvesting (RF-EH) techniques, which are known to provide feasible solutions to enhance the performance of energy constrained wireless communication systems, have gained increasing attention. In this paper, we consider a wireless-powered cooperative communication network (WPCCN) for transferring energy in the downlink and forwarding signals in the uplink. The objective is to maximize the average transmission rate of the system, subject to the total network power constraint. We formulate such a problem as a form of wireless energy transmission based on resource allocation that searches for the joint subcarrier pairing and the time and power allocation, and this can be solved by using a dual approach. Simulation results show that the proposed joint optimal scheme can efficiently improve system performance with an increase in the number of subcarriers and relays.

30(kVA) 초전도발전기 제작 및 특성 (Fabrication and Characteristics of 30〔kVA〕 Superconducting Generator)

  • 손명환;권영길;백승규;박도영;이언용;조영식;류강식
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제3권2호
    • /
    • pp.32-38
    • /
    • 2001
  • A 30[kVA] superconducting generator (SCG) is built and tested at Korea Electrotechnology Research Institute (KERI) in Korea. This superconducting generator has an air-gap winding instead of the typical steel teeth structure. The rotor has 4 field coils of race-track type with NbTi superconducting wired. The rotor is composed of two dampers and a liquid helium composed of two dampers and a liquid helium container in which the field poles reside. The space between the outermost damper and the container is vacuum insulated. A ferrofluid seal is used between the stationary part connected to the couping and the rotor. A helium transfer coupling(HTC) has 3 passages of the recovered heilum gas and a gas flow control system. The open circuit test and sustained short circuit test are preformed to obtain the open circuit characteristics (OCC) and short circuit characteristics (SCC) Also. the test results usder the light load (up to 3.6[kW]) are given. The structure, manufacturing and basis test of the 30[kVA]SCG are discussed.

  • PDF