• Title/Summary/Keyword: HRMS

Search Result 73, Processing Time 0.022 seconds

Automated Attack Path Enumeration Method based on System Vulnerabilities Analysis (시스템 취약점 분석을 통한 침투 경로 예측 자동화 기법)

  • Kim, Ji Hong;Kim, Huy Kang
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.22 no.5
    • /
    • pp.1079-1090
    • /
    • 2012
  • As the number of information asset and their vulnerabilities are increasing, it becomes more difficult for network security administrators to assess security vulnerability of their system and network. There are several researches for vulnerability analysis based on quantitative approach. However, most of them are based on experts' subjective evaluation or they require a lot of manual input for deriving quantitative assessment results. In this paper, we propose HRMS(Hacking and Response Measurement System) for enumerating attack path using automated vulnerability measurement automatically. HRMS can estimate exploitability of systems or applications based on their known vulnerability assessment metric, and enumerate attack path even though system, network and application's information are not fully given for vulnerability assessment. With this proposed method, system administrators can do proactive security vulnerability assessment.

Analysis of all PCB Congeners in Air Samples by HRGC/HRMS (대기 시료 중 PCBs 전 이성체 분석에 관한 연구)

  • Kim, Kyoung-Soo;Song, Byung-Joo;Kim, Jong-Guk
    • Analytical Science and Technology
    • /
    • v.16 no.4
    • /
    • pp.309-319
    • /
    • 2003
  • This study was performed to describe analysis method of 209 PCB congeners in ambient air samples. The samples were collected by high volume air sampler in Chonju city. Extracted samples were cleaned by silicagel cleanup modified with sulfuric acid and activated carbon cleanup processing. The cleaned samples were analyzed by high resolution gas chromatography and high resolution mass spectrometry (HRGC/HRMS) with DB-5 column (60 m, 0.25 mm i.d., 0.25 m film thickness) to analyze the 209 kinds of PCB congeners. PCBs levels of air samples were detected to the range between 0.003 and $0.163pg-TEQ/m^3$. The PCBs congener of 162 kinds were detected in samples analysed using DB-5 column and 37 kinds peaks were overlapped with congeners more than one. It is difficult to isolate PCB 118/106 and PCB 105/127 in coplanar PCB, so it is likely to overestimate the concentration.. The distribution of coplanar-PCB congeners in origin source samples (Kanechlor and exhaust gas from incinerator) was compared with that in air samples, and PCB 81, PCB 77, PCB 126, and PCB 169 were higher in incinerator samples.

Comparative Evaluation of Three Cognitive Error Analysis Methods Through an Application to Accident Management Tasks in NPPs

  • Wondea Jung;Kim, Jaewhan;Jaejoo Ha;Wan C. Yoon
    • Nuclear Engineering and Technology
    • /
    • v.31 no.6
    • /
    • pp.8-22
    • /
    • 1999
  • This study was performed to comparatively evaluate selected Human Reliability Analysis (HRA) methods which mainly focus on cognitive error analysis, and to derive the requirement of a new human error analysis (HEA) framework for Accident Management (AM) in Nuclear Power Plants (NPPs). In order to achieve this goal, we carried out a case study of human error analysis on an AM task in NPPs. In the study we evaluated three cognitive HEA methods, HRMS, CREAM and PHECA, which were selected through the review of the currently available seven cognitive HEA methods. The task of reactor cavity flooding was chosen for the application study as one of typical tasks of AM in NPPs. From the study, we derived seven requirement items for a new HEA method of AM in NPPs. We could also evaluate the applicability of three cognitive HEA methods to AM tasks. CREAM is considered to be more appropriate than others for the analysis of AM tasks, HRMS is also applicable to the error analysis of AM tasks. But, PHECA is regarded less appropriate for the predictive HEA technique as well as for the analysis of AM tasks. In addition to these, the advantages and disadvantagesofeachmethodaredescribed.

  • PDF

Residues of Co-planar PCBs in Ginseng at Environment of North Gyeongbuk (경북 북부 인삼 재배환경 중 Co-planar PCBs의 잔류)

  • Kim, Jung-Ho
    • Journal of Environmental Science International
    • /
    • v.20 no.8
    • /
    • pp.987-995
    • /
    • 2011
  • Co-planar PCBs(polychlorinated biphenyls) of non-ortho are investigated in soil and ginseng on the North Gyeongbuk with HRGC/HRMS. PCB77 in soil on Yeongju and Sangju are detected 0.0007 pgTEQ/g and 0.0009 pgTEQ/g, respectively. PCB81 in soil on Yeongju and Sangju are detected 0.0113 pgTEQ/g and 0.0108 pgTEQ/g, respectively. Also PCB126 in soil on Yeongju and Sangju are detected 0.0907 pgTEQ/g and 0.0944 pgTEQ/g, respectively. But PCB169 in soil on Yeongju and Sangju is not detected. Total Co-planar PCBs of non-ortho in soil on Yeongju and Sangju are 0.1027 pgTEQ/g and 0.1061 pgTEQ/g, respectively. PCB77 in ginseng on Yeongju and Sangju are detected 0.0008 pgTEQ/g. Then PCB81 in ginseng on Yeongju and Sangju are detected 0.0104 pgTEQ/g and 0.0112 pgTEQ/g, respectively. But PCB126 in ginseng on Yeongju and Sangju are detected 0.0585 pgTEQ/g and 0.0579 pgTEQ/g, respectively. PCB169 in ginseng on Yeongju and Sangju is not detected. Total Co-planar PCBs of non-ortho in ginseng on Yeongju and Sangju are 0.0697 pgTEQ/g and 0.0700 pgTEQ/g, respectively. Relationship of PCBs in between soil and ginseng shown significance($R^2$ : 0.99).

Determination of PCDD/Fs in Disposable Diaper for Infant (유아용 일회용 기저귀의 다이옥신 분석)

  • Shin Jeoung Hwa;Ahn Yun Gyong;Seo Jung Ju
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.29 no.6
    • /
    • pp.814-824
    • /
    • 2005
  • This study analyzed and standardized the harmful substances of organic compounds(dioxins) in disposable diapers for infant's clothing. Commercial samples obtained from Korea, Japan, America and German were determined by HRGC/HRMS. Experimental Methods were consisted of comparision of extracting solvent, analysis of PCDD/Fs, and analysis of PCDD/Fs of extraction in disposable diaper. The results were as follows. No high TEQ values in TCDD(1), PCDD(0.5) and HxCDD(0.1) were found for commercial disposable diapers from country Korea, Japan, U.S.A and German. In extraction for 6hrs experiments, HpCDD and OCDD were detected in disposable diapers of U1, U2 and G2, respectively. In extraction fur 24hrs experiments, HpCDD, OCDD and OCDF were detected in disposable diapers of J3, U1, U2 and U3. So we need to set standards of measurement for harmful materials contained in textile goods. This will make a safe and comfortable clothing environment for all users, regardless of age.

Comparison of the elution patterns for polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDDs/Fs) and dioxin-like polychlorinated biphenyls (PCBs) by manual open columns and automatic parallel LC columns (수동 및 자동화 액체 크로마토그래피 칼럼에 의한 PCDDs/Fs 및 다이옥신과 유사한 PCBs의 용출 패턴 비교)

  • Ahn, Yun Gyong;Shin, Jeoung Hwa;Yoo, Sun Young;Khim, Jeehyeong;Hong, Jongki
    • Analytical Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.13-22
    • /
    • 2005
  • The elution patterns of seventeen 2,3,7,8-substituted PCDDs/Fs and 12 dioxin-like PCBs were studied by both manual open columns and automatic parallel LC columns in cleanup procedure. PCDDs/Fs and non-ortho-PCBs from other mono-ortho-PCBs were separated on automatic LC column, whereas they were not separated on an open manual column. The elution study on two cleanup methods was carried out using the PAR solution of unlabeled congeners and checked the recovery of each congener. Total recoveries of cleanup fractionation were ranged between 61.9 ~ 96.0% for PCDDs/Fs and 70.4 ~ 79.0% for PCBs by manual open columns and 71.8 ~ 104.5% for PCDDs/Fs and 61.3-120.3% for PCBs by automatic parallel LC columns, respectively. Unfortunately, #169-HxCB and 1,2,3,7,8-PeCDD were not separated on DB-5MS capillary column. The ions of 1,2,3,7,8-PeCDD were selected at M/M+2 instead of M+2/M+4 suggested by EPA method 1613. It is possible to discriminate 1,2,3,7,8-PeCDD and PCB #169 in HRGC/HRMS analysis.

Analysis of Dioxins in Meat by HRGC/HRMS (HRGC/HRMS를 이용한 국내유통 육류 중 다이옥신류 분석)

  • Choi, Dongmi;Hu, Soojung;Jeong, Jiyoon;Won, Kyungpoong
    • Analytical Science and Technology
    • /
    • v.14 no.1
    • /
    • pp.88-93
    • /
    • 2001
  • To measure the levels of dioxins in food selling at local markets, meat was analyzed by high resolution gas chromatography/high resolution ass spectrometry (HRGC/HRMS). The food samples were obtained from 5 large cities of Seoul, Chunchon, Daejon, Kwangju and Busan in Korea. All the samples were minced and extracted with Soxhlet extractor for 18 hours. After extraction, extracts were cleaned up by sulfuric acid impregnated silica gel, purified on a series of silica gel, alumina, carbon column chromatography and then analyzed by HRGC/HRMS. The contaminated levels were calculated as the TEQs by multiplying with the corresponding WHO-TEFs for each congeners. The overall recoveries were ranged from 80% to 153% and the limit of detection was about 0.01 ppt at S/N>3. The levels of PCDD/Fs for beef, pork and chicken were 0.018, 0.008 and <0.001 pgTEQ/g, respectively. In addition, the levels of non-ortho-co-planar PCBs for beef, pork and chicken were 0.008, 0.002 and 0.001 pgTEQ/g, respectively. Among food samples analyzed, chicken showed the lowest level of dioxin-like compounds. Regarding congener pattern, OCDD and PCB #77 were the highest contributing congeners.

  • PDF

Residual Multi Pesticides Screening of Dead Birds by Orbitrap High Resolution Mass Spectrometry (오비트랩 고분해능 질량분석기를 이용한 폐사 조류 중 다성분 잔류 농약 스크리닝 기법)

  • Lee, Doo-Hee;Kim, Bo-Kyong;Wang, Seung-Jun;Son, Ki-Dong;Jung, Hyen-Mi;Choi, Jong-Woo
    • Korean Journal of Environmental Agriculture
    • /
    • v.36 no.4
    • /
    • pp.269-278
    • /
    • 2017
  • BACKGROUND: The objective of this study was to evaluate screening method of residual multi pesticides in dead birds by Orbitrap high resolution mass spectrometry (HRMS) to identify the cause of death for birds. METHODS AND RESULTS: Extraction and clean-up method of residual pesticides in liver of dead birds was used QuEChERS (Quick Easy Cheap Effective Rugged and Safe) and method validations was conducted using liquid chromatography and gas chroamtography with triple-quadrupole mass spectrometer (LC/MS/MS and GC/MS/MS) Also, we were evaluated screening method for the determination of residual pesticides in liver of dead birds by LC and GC Orbitrap Mass Spectrometry. Results of method validations, Correlation coefficients of the matrix matched calibration curves were >0.978, and the method detection limits (MDLs) and limits of quantitation (LOQ) were 2.8~72.1 ng/g (18.4 ng/g on average) and 9.0~230 ng/g (58.5 ng/g on average). The accuracy ranged from 69.1%to 130% (103% on average), and the precision values were less than 14.8%(3.8%on average). The screening of residual pesticides in liver of dead birds by LC and GC Orbitrap HRMS was detected monocrotophos, carbofuran, carbosulfan, deltametrin, benfuracarb, carbofuran, phosphamidon, prochloraz in investigated samples. CONCLUSION: This results showed that accurate mass were extraction of residual pesticides in dead birds by Orbitrap HRMS. It suggested that this screening method is applicable to the residual pesticide analysis for the cause of death as a main tool.