• Title/Summary/Keyword: HIGH WATER LEVEL

Search Result 2,613, Processing Time 0.036 seconds

Development of High Precision Underground Water Level Meter Using a Buoyant Rod Load Cell Technique (부력 추를 이용한 지하수위 측정용 센서 개발)

  • Lee Bu-Yong;Park Byoung-Yoon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.1 no.1
    • /
    • pp.36-40
    • /
    • 1999
  • A new method was developed to measure underground water level with high reliability. The principle of new method was to detect a change of a buoyant force according to change in water level of underground water measured by the use of a straingage load cell. Field test of the instrument was carried out in Cheju Island. The results were as follows; 1) The present study provided a possibility to develop a new underground water level meter. 2) This new instrument accomplished high reliability at field test in Cheju Island. 3) There is possibility of development of water level meter which measure various range of water level to detect a weight change of a buoyant forcd.

  • PDF

Development of Plastic Film Type Water Level Sensor for High Temperature (고온용 플라스틱 필름 수위 센서 개발)

  • Lee, Young Tae
    • Journal of the Semiconductor & Display Technology
    • /
    • v.18 no.4
    • /
    • pp.124-128
    • /
    • 2019
  • In this paper, a high temperature plastic film type water level sensor was developed. The high temperature film type water level sensor was manufactured by attaching a copper film to a polyimide film which can be used for a long time at 250℃, by laminating process and patterning the electrode by etching process. For the performance evaluation of the developed film type water level sensor, the temperature dependence of the capacitance was measured, and the deformation was examined after standing for 8 hours in 150℃ air. The developed film type water level sensor can be used at up to 150℃, and can be applied to electric ports and steam devices.

Design of IoT-based Buoyancy-based Level Sensors for Low-cost and High-efficiency (저비용 고효율의 IoT 기반의 부력식 레벨센서 설계)

  • Byeongkon Kim;Sookwan Jang
    • Journal of Sensor Science and Technology
    • /
    • v.33 no.5
    • /
    • pp.378-383
    • /
    • 2024
  • This study developed a buoyancy-based level sensor composed of a buoyant object, a sensing unit, and a signal generation unit to meet the demand of low-cost, high-efficiency inundation-detection sensors. The volume of the submerged buoyant object remained nearly constant even in the presence of water-level fluctuations, allowing stable water-level data acquisition. The measurement resolution and measurement repeatability were confirmed to be within 0.4 mm and 0.3%, respectively. LoRa-based communication was used to implement the IoT-based inundation-detection sensor. The measurement deviation between the sensors is approximately 0.15%. The unresponsive level at which measurement was not possible was confirmed to be approximately 2 mm. Excluding this unresponsive range, the water level measurements exhibited very high linearity, allowing precise measurements. Furthermore, a test bed was established in an inundation-vulnerable area using buoyancy-based level sensors.

A Study on the Development of Hourly Evaporation Recording Instrument for Class A Pan (대형증발계용 매시간 증발 기록계 개발에 관한 연구)

  • Bu-Yong Lee
    • Journal of Environmental Science International
    • /
    • v.10 no.5
    • /
    • pp.323-327
    • /
    • 2001
  • A new method is developed to estimate the evaporation of water from a surface with high accuracy and resolution. The principle of new method is to detect a weight change of buoyant weight according to a change in water level of Class A Pan mesured by the use of a strain-gauge load cell. Field test of evaporation recording new instrument was carried out at Suwon for 10 days July 1999. It is possible in field observation to measure hourly evaporation amount by newly developed evaporation recording instrument in Class A Pan against strong solar radiation. Present study provide a possibility of domestic high accuracy instrument development below than 0.1mm water level measurement accuracy. If there is low humidity and high wind speed conditions which is possible to evaporate from water surface during night time. And it needs continuous study to understand between meteorological elements and latent heat effect at ground level by field observation study using high accuracy evaporation recording instrument.

  • PDF

Development of Capacitive Water Level Sensor System for Boiler (보일러용 정전용량형 수위센서 시스템 개발)

  • Lee, Young Tae;Kwon, Ik Hyun
    • Journal of the Semiconductor & Display Technology
    • /
    • v.20 no.3
    • /
    • pp.103-107
    • /
    • 2021
  • In this paper, a capacitive water level sensor for boilers was developed. In order to accurately monitor the water level in a high-temperature boiler that generates a lot of precipitates, the occurrence of precipitates on the surface of the water level sensor should be small, and a sensor capable of measuring even if the sensor surface is somewhat contaminated is required. The capacitive water level sensor has a structure in which one of the two electrodes is insulated with Teflon coating, and the stainless steel package of the water level sensor is brought into contact with the water tank so that the entire water tank becomes another electrode of the water level sensor. A C-V converter that converts the capacitance change of the capacitive water level sensor into a voltage change was developed and integrated with the water level sensor to minimize noise. The performance of the developed capacitive water level sensor was evaluated through measurement.

A Study for the Selection Method of Control Area of Nonpoint Pollution Source (비점오염원 관리지역의 선정 기법에 관한 연구)

  • Park, Sanghyun;Jeong, Woohyeok;Yi, Sangjin;Lim, Bongsu
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.5
    • /
    • pp.761-767
    • /
    • 2010
  • This study introduces a model of territorial analysis on Chungcheongnam-do Nonsan-chun valley area, which gives an example of a method of selecting the management area for non-point pollution source from land use to help eliminate its source. High discharge load per unit area signify high level of land ratio with high level of basic unit of development load (including factory sites, school sites, roadways), which mean that there are a significant level of urbanization. It is these areas with the examination of the water quality of the nearby river that should be considered as the management area for non-point pollution source. Thus, the management area for non-point pollution source should be sought in areas with high discharge load per unit area and high density of water pollution area. When level of drainage is high the pollution density level is relatively lower, and when the level of drainage is low the density level is relatively higher. The level of pollution from non-point pollution source is much lower with more water flowing through. The possible non-point pollution source areas that were selected with these standards were then examined with the distance from the river, the slope angle, land usage, elevation, BOD discharge density load, T-N discharge density load, T-P discharge density load, and were given a level one through five. Out of the possible areas Nonsan-si Yeonmu-eup Anshim-li was the densest area, and it was given level one. The level one area should be examined further with the field analysis to be selected as the actual management area for non-point pollution source.

Effect of Codonopsis lanceolata Water Extract on the Levels of Lipid in Rats Fed High Fat Diet (더덕 물추출물이 고지방식이를 급여한 흰쥐의 체내 지질 수준에 미치는 영향)

  • 조수열;한은경;성인숙;문혜경
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.27 no.5
    • /
    • pp.940-944
    • /
    • 1998
  • This research was performed to investigate the effect of Codonopsis lanceolata water extracted on the levels of lipid in serum and liver of rats fed high fat diet for 6 weeks. Experimental groups were divided into normal group(NF), high fat diet group(HF), high fat diet and Codonopsis lanceolata water extract treated group(HFW). Codonopsis lanceolata water extract was orally administrated at the level of 0.1ml/100g body weight per day. Body weight gain and feed intake were not significantly different in three groups, but feed efficiency ratio was increased in HF and HFW. The weights of liver, kidney, heart were not significantly different among the groups. The level of serum total lipid was higher in HF than NF, but Codonopsis lanceolata water extract decreased the level of the lipid. The levels of serum triglyceride and total cholesterol were significantly increased in HF, but they were significantly decreased by administration of Codonopsis lanceolata water extract. The levels of serum HDL-cholesterol and phospholipid were slightly increased by Codonopsis lanceolata water extract. Codonopsis lanceolata water extract significantly decreased the levels of liver total lipid, triglyceride and total cholesterol which were increased by high fat diet.

  • PDF

Patterns of Water Level Increase by Storm Surge and High Waves on Seawall/Quay Wall during Typhoon Maemi (태풍 매미 내습시 해일$\cdot$고파랑에 의한 호안$\cdot$안벽에서의 수위증가 패턴 고찰)

  • Kang, Yoon-Koo
    • Journal of Ocean Engineering and Technology
    • /
    • v.19 no.6 s.67
    • /
    • pp.22-28
    • /
    • 2005
  • We investigated the characteristics of the overflow/wave overtopping, induced by the storm surge and high waves in Masan bay and Busan Coast during Typhoon 'Maemi', which landed at the southeast coast of the Korean peninsula on September, of 2003, causing a severe inundation disaster. Characteristics of the water level, increase by the overflow / wave overtopping, were discussed in two patterns. One is the increase of water level in the region, located inside of a bay, like Masan fishing port, and the waves are relatively small. The other is in the open sea, in which the waves act directly, as on the seawall in Suyong bay. In the former region, the water level increase was affected by the storm surge, as well as the long period oscillation and waves. In Masan fishing port, about $80\%$ of the water level increase on the quay wall was caused by the storm surge. In the latter one, it was greatly affected by the wave run-up. In Suyong bay, about $90\%$ of the water level increase on the seawall was caused by the wave run-up.

Study on Measurement of Flood Risk and Forecasting Model (홍수 위험도 척도 및 예측모형 연구)

  • Kwon, S.H.;Oh, H.S.
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.38 no.1
    • /
    • pp.118-123
    • /
    • 2015
  • There have been various studies on measurements of flood risk and forecasting models. For river and dam region, PDF and FVI has been proposed for measurement of flood risk and regression models have been applied for forecasting model. For Bo region unlikely river or dam region, flood risk would unexpectedly increase due to outgoing water to keep water amount under the designated risk level even the drain system could hardly manage the water amount. GFI and general linear model was proposed for flood risk measurement and forecasting model. In this paper, FVI with the consideration of duration on GFI was proposed for flood risk measurement at Bo region. General linear model was applied to the empirical data from Bo region of Nadong river to derive the forecasting model of FVI at three different values of Base High Level, 2m, 2.5m and 3m. The significant predictor variables on the target variable, FVI were as follows: ground water level based on sea level with negative effect, difference between ground altitude of ground water and river level with negative effect, and difference between ground water level and river level after Bo water being filled with positive sign for quantitative variables. And for qualitative variable, effective soil depth and ground soil type were significant for FVI.

Storm Surge Caused by the Typhoon “Maemi” in Kwangyang Bay in 2003 (광양만에서의 2003년 태풍 “매미”에 의한 폭풍해일)

  • 김현성;이석우
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.9 no.3
    • /
    • pp.119-129
    • /
    • 2004
  • The surges caused by the typhoon “Maemi” which struck the southern coast of Korea are analysed in Kwangyang Bay on September 12, 2003. The deviations of the high water level were 93∼108 cm and the maximum deviations of the water level (maximum surges) were 176∼196 cm in Kwangyang Bay during the typhoon “Maemi”. The major parameters of the maximum deviations of the water level are as follows: Analysis shows that the pressure drop increased the sea level by 59 cm, the flood of the Sumjin River by 4-5 cm and the external surge propagation and wind setup by 113∼132 cm. During the typhoon “Maemi”, the highest high water recorded in Kwangyang Port (PT3) is 460 cm, which is higher by 5 cm than the highest high water (455 cm) with return period of 100 years estimated in planning the Kwangyang steelworks (POSCO) grounds and higher by 15 cm than the observed highest high water (445 cm) recorded during the typhoon “Thelma” on 1987. Thus, the highest high water caused by the typhoon “Maemi” is higher than the extreme highest high water for the last 20 years in Kwangyang Bay.