• Title/Summary/Keyword: HFOV

Search Result 7, Processing Time 0.027 seconds

The Comparison of Histopathology of Cats Received Conventional Mechanical Ventilation and High Frequency Oscillation Ventilation (전통적 인공호흡과 고빈도환기시 폐의 조직.병리학적 소견의 비교 관찰)

  • Lee, Kwan-Ho;Kim, Young-Jo;Chung, Jae-Chun;Lee, Hyun-Woo;Nam, Hae-Joo;Lee, Tae-Sook
    • Journal of Yeungnam Medical Science
    • /
    • v.6 no.2
    • /
    • pp.39-46
    • /
    • 1989
  • The tracheobronchial histopathologic findings in 7 healthy cats used with high frequency oscillation ventilation (HFOV) were compared with those in 6 cats used with conventional mechanical ventilation (CMV). 4-point, 9-variable scoring system was used to evaluate the injury in the trachea, right & left main bronchi and parenchyme. The following results were obtained ; 1) The tracheobronchial tree received HFOV had no significant damage compared with CMV (P>0.05). 2) Intraepithelial mucus loss and emphysema were s lightly more prominent in CMV groups. As above results ; the tracheobronchial histopathologic difference was not prominent between CMV and HFOV groups received with relatively short period, however, the cellular function and barotrauma may be more prominent in CMV groups. From now on, as causes of tracheobronchial injury in HFV, interaction between humidification and mechanical trauma considers further study.

  • PDF

PIV measurement of oscillatory flow in a micro-channel as a bronchiole model

  • LEE Won-je;KAWAHASHI Massaki;HIRAHARA Hiroyuki
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.125-134
    • /
    • 2004
  • The improvement of artificial respiration method has brought about the decrease in mortality of pulmonary diseases patients. Various respiratory curative methods, inclusive of HFOV (High Frequency Oscillatory Ventilation), have been developed for more effectual and less harmful management of acute respiratory failure. However, the mechanism of gas transfer and diffusion in a bronchiole has not yet been clarified in detail. As a first approach to the problem, we measured oscillatory flows in a Y-shaped micro-channels as bronchiole model by micro Particle Image Velocimetry(micro PIV). In order to establish the fundamental technique of PIV measurements on oscillatory air flow in a micro-channel, we used about 500-nm-diameter incense smoke particles, a diode laser, a high speed camera including an objective lens, and a HFOV, which is effective technique for medical care of pulmonary disease patients, especially, infants. The bronchiole model size is that parent tube is $500\{mu}m$ width and $500\{mu}m$ depth, and daughter tubes are $450\{mu}m$ width and $500\{mu}m$ depth. From this study made on the phenomenon of fluid in micro size bronchus branch of a lung, we succeeded to get time series velocity distribution in a micro scale bronchial mode. The experimental results of velocity distribution changing with time obtained by micro PIV can give fundamental knowledge on oscillatory airflow in micro-channel.

  • PDF

Factors influencing arterial $CO_2$ tension in cats during high frequency oscillation ventilation (고빈도 진동 환기가 동맥혈의 호흡성 가스에 미치는 영향)

  • Do, Jun-Young;Lee, Jae-Yick;Lee, Kwan-Ho;Kim, Yeung-Jo;Chung, Jae-Chun;Lee, Hyun-Woo;Lee, Suck-Kang
    • Journal of Yeungnam Medical Science
    • /
    • v.6 no.2
    • /
    • pp.47-55
    • /
    • 1989
  • High frequency ventilation (HFV) is a new ventilatory technique that uses very small tidal volume(less than the anatomic dead space) and high frequency, and classified 4 distinct types according to frequency and mode of gas delivery. The mechanism of gas transport of high frequency oscillation ventilation(HFOV) is somewhat different to other types of HFV. To evaluate the determinants of $PaCO_2$ in HFOV, a study was done with a HFOV on 9 cats, and the results are : 1) $PaCO_2$ was not correlated with frequency at the constant stroke volume(6 voltage) and bias flow (6L/minutes). 2) $PaCO_2$ was correlated with stroke volume but not with bias flow under the constant frequency(15Hz/min) and bias flow(3 to 6L/min). From above results, the main determinant of $PaCO_2$ on artificial ventilation with HFOV was stroke volume, but further study between flow, the site of delivery to the airway and humidification of bias flow and $CO_2$ elimination is required in future research.

  • PDF

Optical Design of a Subminiature Catadioptric Omnidirectional Optical System with an LED Illumination System for a Capsule Endoscope (LED 조명계를 결합한 캡슐내시경용 초소형 반사굴절식 전방위 광학계의 설계)

  • Moon, Tae Sung;Jo, Jae Heung
    • Korean Journal of Optics and Photonics
    • /
    • v.32 no.2
    • /
    • pp.68-78
    • /
    • 2021
  • A subminiature catadioptric omnidirectional optical system (SCOOS) with 2 mirrors, 6 plastic aspherical lenses, and an illumination system of 6 light emitting diodes, to observe the 360° panoramic image of the inner intestine, is optically designed and evaluated for a capsule endoscope. The total length, overall length, half field of view (HFOV), and F-number of the SCOOS are 14.3 mm, 8.93 mm, 51°~120°, and 3.5, respectively. The optical system has a complementary metal-oxide-semiconductor sensor with 0.1 megapixels, and an illumination system of 6 light-emitting diodes (LEDs) with 0.25 lm to illuminate on the 360° side view of the intestine along the optical axis. As a result, the spatial frequency at the modulation transfer function (MTF) of 0.3, the depth of focus, and the cumulative probability of tolerance at the Nyquist frequency of 44 lp/mm and MTF of 0.3 of the optimized optical system are obtained as 130 lp/mm, -0.097 mm to +0.076 mm, and 90.5%, respectively. Additionally, the simulated illuminance of the LED illumination system at the inner surface of the intestine within HFOV, at a distance of 15.0 mm from the optical axis, is from a minimum of 315 lx to a maximum of 725 lx, which is a sufficient illumination and visibility.

Optical Design of a Reflecting Omnidirectional Vision System for Long-wavelength Infrared Light (원적외선용 반사식 전방위 비전 시스템의 광학 설계)

  • Ju, Yun Jae;Jo, Jae Heung;Ryu, Jae Myung
    • Korean Journal of Optics and Photonics
    • /
    • v.30 no.2
    • /
    • pp.37-47
    • /
    • 2019
  • A reflecting omnidirectional optical system with four spherical and aspherical mirrors, for use with long-wavelength infrared light (LWIR) for night surveillance, is proposed. It is designed to include a collecting pseudo-Cassegrain reflector and an imaging inverse pseudo-Cassegrain reflector, and the design process and performance analysis is reported in detail. The half-field of view (HFOV) and F-number of this optical system are $40-110^{\circ}$ and 1.56, respectively. To use the LWIR imaging, the size of the image must be similar to that of the microbolometer sensor for LWIR. As a result, the size of the image must be $5.9mm{\times}5.9mm$ if possible. The image size ratio for an HFOV range of $40^{\circ}$ to $110^{\circ}$ after optimizing the design is 48.86%. At a spatial frequency of 20 lp/mm when the HFOV is $110^{\circ}$, the modulation transfer function (MTF) for LWIR is 0.381. Additionally, the cumulative probability of tolerance for the LWIR at a spatial frequency of 20 lp/mm is 99.75%. As a result of athermalization analysis in the temperature range of $-32^{\circ}C$ to $+55^{\circ}C$, we find that the secondary mirror of the inverse pseudo-Cassegrain reflector can function as a compensator, to alleviate MTF degradation with rising temperature.

Prognosis of Bochdalek Hernia in Neonate after Change in Management Principle (치료 원칙 변화에 따른 신생아 Bochdalek 탈장의 예후)

  • Seo, Jin-Young;Nam, So-Hyun;Kim, Dae-Yeon;Kim, Seong-Chul;Kim, Ai-Rhan E.;Kim, Ki-Soo;Pi, Soo-Young;Kim, In-Koo
    • Advances in pediatric surgery
    • /
    • v.12 no.2
    • /
    • pp.192-201
    • /
    • 2006
  • There are considerable controversies in the management of congenital diaphragmatic hernia. By 1997, early operation, routine chest tube on the ipsilateral side and maintainingrespiratory alkalosis by hyperventilation were our principles (period I). With a transition period from 1998 to 1999, delayed operation with sufficient resuscitation, without routine chest tube, and permissive hypercapnia were adopted as our practice. High frequency oscillatory ventilation (HFOV) and nitric oxide (NO) were applied, if necessary, since year 2000(period II). Sixty-seven cases of neonatal Bochdalek hernia from 1989 to 2005 were reviewed retrospectively. There were 33 and 34 cases in period I and II, respectively. The neonatal survival rates were 60.6 % and 73.5 %, respectively, but the difference was not significant. In period I, prematurity, low birth weight, prenatal diagnosis, inborn, and associated anomalies were considered as the significant poor prognostic factors, all of which were converted to nonsignificant in period II. In summary, improved survival was not observed in later period. The factors considered to be significant for poor prognosis were converted to be nonsignificant after change of the management principle. Therefore, we recommend delayed operation after sufficient period of stabilization and the avoidance of the routine insertion of chest tube. The validity of NO and HFOV needs further investigation.

  • PDF

Clinical Outcome and Prognostic Factors of Acute Respiratory Distress Syndrome in Children (소아 급성 호흡곤란 증후군의 치료 성적 및 예후 인자)

  • Ko, Jung-Min;Ha, Eun-Ju;Lee, Eun-Hee;Lee, So-Youn;Kim, Hyo-Bin;Hong, Soo-Jong;Park, Seong-Jong
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.6
    • /
    • pp.599-605
    • /
    • 2005
  • Purpose : The purpose of this study was to examine the causes, clinical courses and outcomes in children with acute respiratory distress syndrome(ARDS), and evaluate the physiologic variables as prognostic factors in the patients. Methods : Retrograde medical chart review was carried out in 24 patients who were diagnosed with ARDS at the pediatric intensive care unit(PICU) during 20-month period. Results : The incidence of ARDS among all PICU admission was 3.7 percent and the mortality rate was 37.5 percent, which was 14.8 percent of overall deaths in PICU. The most common causes of ARDS were pneumonia and sepsis. We found significant differences between survivors and nonsurvivors in $PaO_2/FiO_2$ ratio(P/F ratio), alveolar arterial oxygen gradient and oxygenation index(OI) on the second day from the onset of ARDS. Therapies for ARDS such as high frequency oscillator ventilation(HFOV), recruitment maneuver and low dose corticosteroid improved the P/F ratio and OI, especially in survivors. Conclusion : The mortality rate of children with ARDS was 37.5 percent; an important cause of death in PICU. HFOV, recruitment maneuver and low dose corticosteroid seemed to be effective in pediatric ARDS. The P/F ratio, alveolar arterial oxygen gradient and OI on the second day from the onset of ARDS may be useful as prognostic factors.