• 제목/요약/키워드: HFMT survey

검색결과 2건 처리시간 0.016초

경상남도 언양 및 봉계리 지역에서의 전기, 전자탐사에 의한 양산단층의 심부구조 연구 (A Study on the Deep Structure of Yangsan Fault by Electric and Electromagnetic Surveys in Unyang and Bong-gye Areas, Kyeongnam Province, Korea)

  • 손호웅;윤혜수;오진용
    • 자원환경지질
    • /
    • 제33권6호
    • /
    • pp.525-536
    • /
    • 2000
  • Electromagnetic and electric surveys were performed to reveal the deep structure of the Yangsan fault in the Bong-gye and Unyang areas, Kyeongnam Province, Korea. Especially, high-frequency magnetotelluric (HFMT) method of EM survey was mainly employed to study the deep subsurface configuration of Yangsan fault. HFMT survey was performed at 25 points of spacing 50 m, making 1.3 km survey line in Unyang area and 13 points of spacing 50 m, making 0.6 km survey line in Bong-gye area. Two 2-D cross-sections (Unyang and Bong-gye areas) were achieved as results. Electric survey by dipole-dipole array was performed to study the structure of shallow subsurface and compare the results with HFMT surveys. The results of HFMT and electric surveys show that Yangsan fault is a geologic boundary. It is very narrow and steep (about $80^{\circ}C$), and extends to 1~1.5 km depth.

  • PDF

필댐의 안정성 해석 연구 (1) (A STUDY ON THE SAFETY ANALYSIS OF ROCK FILL DAM (1))

  • 손호웅;이대근
    • 지구물리
    • /
    • 제6권3호
    • /
    • pp.165-177
    • /
    • 2003
  • 필댐의 안정성 해석에 있어서 누수와 내부침식은 매우 중요한 평가의 한 부분이다 연구대상 지역의 필댐은 내부침식으로 추정되는 댐 상부의 공동발생 및 과대 누수량으로 문제가 발생하여, CGS(compaction grouting system)으로 보강공사를 수행하였으며, 본 보강방법은 주입재료 및 주입압력이 중요한 변수로 작용을 한다. 본 연구에서는 CGS 보강이 필댐의 안정성에 미치는 영향을 CGS보강 전후에 지구물리탐사를 수행하여 해석하였다. 본 조사에 적용된 방법에는 전기비저항탐사, 탄성파 굴절법탐사, GPR탐사, HFMT탐사 등이 적용되었다. 조사결과 CGS 보강으로 댐의 전제척인 거동에 많은 영향을 준 것으로 나타났으며, 주입압력이 과대하여 댐 중심코아에 많은 변위가 발생된 것을 확인할 수 있었다.

  • PDF