• Title/Summary/Keyword: HFC-22

Search Result 55, Processing Time 0.018 seconds

Pool Boiling Heat Transfer Correlation for Pure Refrigerants (순수냉매의 풀비등 열전달 상관식)

  • 고영환;김종곤;송길홍;정동수;김영일
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.10
    • /
    • pp.941-949
    • /
    • 2000
  • Pool boiling heat transfer coefficients (HTCs) of HCFC123, CFC11, HCFC142b, HFC134a, CFC12, HFC22, HFC125 and HFC32 on a horizontal smooth tube have been measured. The experimental apparatus is specially designed to simulate the real heat transfer tube with the use of the secondary fluid of water as a heat source rather than a conventional electric heat source. Data were taken in the order of decreasing heat flux starting at $80 ㎾/m^2\; and \;ending\; at\; 5㎾/m^2\;in\; the\; poo\;l temperature\; at\; 7^{\circ}C$, Test results showed that HTCs of HFC125, and HFC32 are 50~67% higher than those of HCFC22. It is also found that some of the popular pool boiling heat transfer correlations in the literature are not good to predict the HTCs of newly developed alternative refrigerants. A new correlation was developed by a regression analysis which is based upon the consistent data obtained in this study and it showed an excellent agreement with all experimental data having an absolute mean deviation of less than 10%.

  • PDF

A Performance Comparison of Oil-free Scroll Compressors with R-12, R-134a and R-22 (R-12, R-134a 및 R-22를 사용한 무급유식 스크롤압축기의 성능 비교)

  • Pak, H.Y.;Park, K.W.;Park, Y.I.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.5 no.4
    • /
    • pp.306-317
    • /
    • 1993
  • In this study, a performance comparison of scroll compressor for various refrigerants(CFC-12, HCFC-22 and HFC-134a) has been numerically carried out. The thermodynamic properties have been calculated by using the recent experimental equations and the performance has been investigated qualitatively at the same geometric specifications and operating conditions of scroll compressor. The results are as follows; HFC-134a has the highest compression ratio of 5.40. The mass flow rate of HCFC-22, which affects the cooling capacity of refrigerant system, is higher than that of other refrigerants. HFC-134a has the highest adiabatic efficiency in comparison with CFC-12 and HCFC-22.

  • PDF

Estimation of Emission Factor (Residual Rate) and Inventory of HFC-134a from Mobile Air Conditioners of Scrap Truck (폐트럭으로부터 온실가스 HFC-134a의 탈루배출계수와 인벤토리 산정에 대한 연구)

  • Kim, Eui-Kun;Kim, Seungdo;Kim, Hyerim;Lee, Young Phyo;Byun, Seokho;Lee, Dong Won
    • Journal of Environmental Science International
    • /
    • v.22 no.9
    • /
    • pp.1105-1113
    • /
    • 2013
  • This paper attempted to estimate the emissions of HFC-134a from scrap truck as a result of measuring the residual quantities of HFC-134a in air conditioner of scrap truck. We measured the residual amounts in the scrap truck of 138 by applying commercial recover for refrigerants. The average residual rate(disposal-phase emission factor) is reported to be $44.3{\pm}3.3%$ within a confidence interval of 95%. Recent year model trucks exhibit the higher residual rates. Little variation, however, is observed in regard to vehicle size. The HFC-134a emission quantity from scrap truck in 2011 is estimated to be 55,908 $tCO_2$-eq that demonstrates 21.4% increase to compare with that in 2007. As the numbers of truck have increased dramatically during the last two decades, the emissions of HFC-134a from scrap truck would increase sharply in the next coming years. HFC-134a is a very high GWP greenhouse gas. therefore have to reduce the emissions from the scrap truck and need to find ways to recycle. The chemical compositions of refrigerants from scrap truck are quite similar to those of new refrigerants, suggesting that the refrigerants from scrap truck could be reused as refrigerant.

Heat and Mass Transfer Characteristics and Performance Evaluation of a Double-Tube Condenser for an Alternative Refrigerant (대체냉매의 2중관 응축기 열 및 물질전달과 성능평가)

  • 이상무;박병덕;소산번
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.6
    • /
    • pp.468-476
    • /
    • 2002
  • This paper deals with heat and mass transfer characteristics and performance evaluation of a counter flow double-tube condenser for a multi-component refrigerant mixture. The local heat and mass transfer characteristics of ternary zeotropic refrigerant mixtures composed of HFC32/HFC125/HFC134a are evaluated for a counter flow double-tube condenser cooled by water. Then, the local values of vapor quality, thermodynamic states at bulk vapor, vapor-liquid interface and bulk liquid, heat flux and condensation mass flux are obtained. The heat exchange performance for ternary zeotropic refrigerant mixtures composed of HFC32/HFC125/HFC134a on the total pressure drop and the heat transfer characteristics are also compared with those for R404A, R410A, R502, R22, R32, Rl23 and R134a.

Pool Boiling Heat Transfer Coefficients of New Refrigerants on Various Enhanced Tubes (열전달 촉진관에서 신냉매의 풀비등 열전달계수)

  • 박진석;김종곤;정동수;김영일
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.8
    • /
    • pp.710-719
    • /
    • 2001
  • Pool boiling heat transfer coefficients (HTCs) of HCFC123, HFC134a, HCFC22, HFC407C, HFC410A and HFC32 wre measured on a horizontal smooth tube, 26 fpi low fin tube, Turbo-B and Thermoexcel-E enhanced tubes. AN experimental apparatus was designed such that all tubes heated by cartridge heaters could be installed at the same time to save the refrigerant. Data were taken in the pool of $7^{\circ}C$ with the heat flux decreasing from 80 kW/$m^2\;to\;5kW/m^2$. Test results showed that HTCs of pure refrigerants and those of a azeotrope were greatly influenced by reduced pressure. HTCs of HFC407C were 21~25% lower than those of HCFC22 due to mass transfer resistance. For all refrigerants, enhanced tubes with sub-surface and sub-tunnels showed the largest heat transfer enhancement. Especially the largest heat enhancement was obtained for HCFC123 whose reduced pressure is the lowest among al the refrigerants tested. This indicates that either Turbo-B or Thermoexcel-E enhanced tube would be the best choice when used with a low vapor pressure refrigerant.

  • PDF

HTPB Propellant Ageing Property and HFC Base Shelf-life Evaluation Method (HTPB 추진제 노화 특성 및 HFC 기반 수명 평가 기법)

  • Cho, Wonho;Westerlund, M.;Ryoo, Baekneung;Jung, Gyoodong;Yoo, Jichang
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.5
    • /
    • pp.59-65
    • /
    • 2018
  • During natural aging, hydroxyl-terminated polybutadiene(HTPB) propellant undergoes a series of slow physico-chemical degradation reactions. By using accelerated ageing conditions it is possible to simulate the material behavior at different time-temperatures focusing on in-service conditions. Aging behaviors of HTPB propellant are investigated using HFC(heat flow calorimeter), a universal technique for measuring the rate of slow chemical and physical processes in long-term storage.

Application of Procedures to Calculate Thermodynamic Properties of Carbon Dioxide, HFC-134a and HCFC-22

  • Park Hyoung Joon;Park Kyoung Kuhn
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.12 no.4
    • /
    • pp.176-183
    • /
    • 2004
  • Systematic methods to calculate thermodynamic properties of carbon dioxide, HFC-134a and HCFC-22 are presented. First, application of a basic method to identify the saturation state with given temperature or pressure is attempted and the feasibility of auxil­iary equations is tested. Next, detailed procedures are suggested to tell a phase when tem­perature/pressure and another property are specified. Finally the Newton-Raphson method is applied to calculate unknown thermodynamic properties fixing the state with the two inde­pendent properties specified. The procedures described here are utilized to develop a computer program, which is used to find the relation between temperature and pressure with maximum isobaric heat capacity for super-critical carbon dioxide.

The Design and Performance Test of a Centrifugal Compressor for HFC-134a Refrigerant (HFC-134a용 원심압축기의 성능시험 및 설계방안)

  • Sin, Jung-Kwan;Kim, Kyung-Hoon;Kang, Shin-Hyoung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.3
    • /
    • pp.139-148
    • /
    • 2010
  • A centrifugal compressor for HFC-134a has been newly designed and developed. Flow analysis using commercial programs was used to evaluate performance and internal flow of the impeller, inlet guide vane and diffuser etc. The purpose of this study is to establish the design theory necessary to the development of HFC-134a centrifugal compressors and to supply basic data related to design by reviewing design values and experimental values through the performance test. The compressor for HFC-134a was also investigated experimentally to check compression performance. The calculated data coincide the test results of compressor. The data obtained in the present study are useful for design of HFC-134a centrifugal compressors.

Effects of Chicken Treated with Hwangki-Beni Koji Sauces on ROS Generating and Scavenging Related Enzyme Activities in Rats Fed with a High Fat and High Cholesterol Diet (황기홍국소스를 처리한 계육이 고지방 및 고콜레스테롤 식이 흰쥐의 ROS 생성 및 소거계 관련 효소의 활성에 미치는 영향)

  • Kim, Jae-Won;Kim, Soon-Dong;Youn, Kwang-Sup
    • Korean Journal of Food Science and Technology
    • /
    • v.42 no.5
    • /
    • pp.605-612
    • /
    • 2010
  • The dietary effects of chicken treated with Hwangki-Beni Koji sauce (HBS) on reactive oxygen species (ROS) generating and scavenging related enzyme activities in rats fed with a high-fat and high-cholesterol diet were investigated. The rats (five rats per group) were divided into a normal control diet group (NC), a high-fat and high-cholesterol diet control group (HFC), HFC plus base sauce-treated chicken supplemented diet group (HFC-BS), and a HFC plus HBStreated chicken supplemented diet group (HFC-HBS), and fed for 5 weeks. Total type T (T) and type O (O) hepatic xanthine oxidoreductase in HFC-HBS were 27.91-35.78% and 24.57-31.84% lower than those of HFC and HFC-BS, respectively. In HFC-HBS compared with HFC and HFC-BS, superoxidase dismutase activity was 62.89-64.50% higher, glutathione S-transferase activity was 19.29-25.17% higher, glutathione content was 25.11-53.30% higher, and lipid peroxide content was 20.29-24.19% lower. Therefore, chicken treated with HBS may prevent liver damage by the ROS formed from a high-fat and high -cholesterol diet.

Glasswort Powder Diet Activates Lipid Metabolism in Rat (함초분 첨가 고지방식이 흰쥐의 지방대사 연구)

  • Seo, Hyo-Bin;Kwak, Yun-Young;Nam, Ju-Ock;Song, Young-Ju;Kim, Byung-Oh;Ryu, Sung-Pil
    • Journal of Life Science
    • /
    • v.22 no.4
    • /
    • pp.478-485
    • /
    • 2012
  • The purpose of this study was to investigate the effects of glasswort powder intake on lipid metabolism. Rats were divided into three groups: a group fed a normal diet (CON), one fed a high fat diet (HFC), and one fed a high fat diet with glasswort powder (HFG). They were fed their respective diet for four weeks. Body weight was significantly lower (9%) in the HFG group than in the HFC group at the fourth week. According to the feces analysis, the HFG group showed the highest fat level (120% vs. CON; 138% vs. HFC) and fecal calories (110%). The concentration level of TG and LDL-C was 71.8% lower in the HFG group compared to the HFC group, while the concentration level of HDL-C was 152% higher in the HFG group. Expression of FABP in the liver was 197% greater in the HFG compared to the HFC group, with the expression of CPT-1 showing a similar tendency. These results suggest that glasswort powder intake suppresses weight gain and improves fat metabolism at the level of liver cells. From these results, we suggest that glasswort powder is effective against obesity by inhibiting the absorption of fat in the digestive tract.