• Title/Summary/Keyword: HFC-134a(R134a)

Search Result 38, Processing Time 0.024 seconds

Numerical Study on Tip Clearance Effect on Performance Characteristics of a Centrifugal Compressor for a R134a Turbo-Chiller (R134a 터보냉동기용 원심압축기의 익단간극이 성능특성에 미치는 영향에 관한 수치해석적 연구)

  • Lee, Kyoung-Yong;Choi, Young-Seok;Park, Woon-Jean
    • The KSFM Journal of Fluid Machinery
    • /
    • v.7 no.6 s.27
    • /
    • pp.38-44
    • /
    • 2004
  • In this study, the overall performance and the effect of the tip leakage flow of the centrifugal compressor with a refrigerant HFC-l34a were numerically studied using CFX-TASCflow. To study the effect of the tip leakage flow, the numerical study of the overall performance of HFC-l34a centrifugal compressor with a cascade diffuser was preceded and compared with the experimental result. Six different tip clearances were used to consider the influence of the tip clearance on the performance. The tip leakage flow was illustrated for qualitative discussion. The results obtained in this study can be applied to the determination of the cold clearance.

The Design and Performance Test of a Centrifugal Compressor for HFC-134a (대체냉매용 원심압축기의 설계 및 성능시험)

  • Sin, Jung-Kwan;Kim, Kyung-Hun
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.250-257
    • /
    • 2002
  • A centrifugal compressor for HFC-l34a has been newly designed and developed. Flow analysis using commertial programs was used to evaluate performance and internal flow of the impeller, inlet guide vane and diffuser etc. and design software was developed. The compressor for HFC-l34a was also investigated experimentally to check compression performance. The calculated data coincide the test results of compressor. The data obtained in the present study are useful for design of HFC-l34a centrifugal compressors.

  • PDF

Kinetics Change of the R-134a Gas Hydrate Formation in Seawater with the Addition of Edible Surfactants (R-134a 가스 하이드레이트 형성 속도에 미치는 식용 계면활성제 첨가의 영향)

  • Jeong, Hui Cheol;Kim, A Ram;Lim, Jun-Heok;Won, Yong Sun
    • Clean Technology
    • /
    • v.22 no.3
    • /
    • pp.154-160
    • /
    • 2016
  • For any conceivable desalination process using the gas hydrate formation, the kinetics has to be one of the most important parameters from the economic point of view. We thus were to improve the kinetics of the R-134a (also known as HFC-134a) gas hydrate formation by using promoters and three different kinds of edible surfactants were selected for the desalination process targeted to produce potable water; κ-carrageenan, lecithin, and polysorbate 80 among anionic, amphoteric, and nonionic surfactants, respectively. Then, the kinetics change of the R-134a hydrate formation was monitored by varying the surfactant concentration. Experimental results demonstrated that the rate of R-134a hydrate formation increases with the addition of edible surfactants in general and the effect as a promotor has an order of polysorbate 80 > κ-carrageenan > lecithin. As a supportive measure, the atomic charges of each surfactant were calculated by using a DFT (density functional theory)-based molecular modeling and the results showed a positive relationship between the promotor effect of each surfactant and the number of oxygens available for hydrogen bonding and the negativity of their atomic charge values.

Performance Analysis of a Centrifugal Compressor for HFC-134a with Variation of Diffuser Vane Angle (디퓨저 베인 설치각 변화에 따른 R134a 원심압축기 성능 분석)

  • Park, Han-Young;Shin, You-Hwan;Lee, Yoon-Pyo;Kim, Kwang-Ho;Chung, Jin-Taek;Cho, Yong-Hun;Kim, Jong-Seong
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2823-2828
    • /
    • 2007
  • Numerical simulation on the two-stage centrifugal compressor with Low Solidity Vaned Diffuser LSVD) for HFC-134a Turbo-chiller was performed using a commercial code. The comparative study with experimental results from other compressor was also investigated to testify the simulation schemes. The numerical analysis was separately simulated for each stage of the compressor and the effect of impeller-diffuser flow interaction was considered. Setting angle of the diffuser vane changed in the range of 15 deg. and the effects on its variation were discussed in detail including the flow analysis in the passage of the compressor. The vane setting angle obtained from the preliminary design was slightly adjusted to the optimal value by the performance enhancement in terms of pressure recovery and flow characteristics.

  • PDF

접촉압력을 고려한 R-134a용 냉도기유의 윤활성 평가 연구

  • 나병철;전경진;한동철
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1997.10a
    • /
    • pp.145-151
    • /
    • 1997
  • PAG(Polyalkylene Glycol) and esters are tested with HFC-134a as a refrigeration oil. This investigation enhances the testing method by taking the compressor's environment into account. A testing environment charged with refrigerant gas more closely simulates the conditions of a compressor. The friction coetTicient of the PAG/HFC-134a system is similar to that of the mineral oil/CFC-12 system at operating conditions. Ester oils are preferable at the start & stop condition in the lubricity aspect. PAG shows good lubricity in conditions of extreme contact pressure. Consequently, this test provides reliable results on compressor lubricity of refrigeration oils with HFC-134a. It suggests a methodological way for the proper selection of refrigeration oils that may improve the durability and performance of a compressor.

  • PDF

Measurement of R-134a Leakage from Vehicle Equipped Mobile Air Conditioning(MAC) System (실차를 이용한 자동차 에어컨 냉매 누출량 평가)

  • Kim, Ji Young;Seo, Chungyoul;Lee, Sangeun;Kim, Jeongsoo
    • Journal of Climate Change Research
    • /
    • v.3 no.2
    • /
    • pp.153-159
    • /
    • 2012
  • CFC-12 used in mobile air conditioning(MAC) system has been replaced by R-134a, a type of HFC refrigerant, from 1991 to 1994. R-134a has since been widely used as a refrigerant of a mobile air conditioner. However, it is one of the six main green house gases listed in Kyoto Protocol, which makes it imperative to regulate its emission and develop alternative refrigerants. In this study, the concentration of leaked R-134a was measured using VT(Variable Temperature) shed and Running loss test shed to analyze the level of air conditioner refrigerant leaked in a vehicle. According to the analysis of the concentration of R-134a leaked from a vehicle parked, annual leakage amount of R-134a was in the range of 6.46~13.28 g/yr. The figure was similar with the leakage from the mobile air conditioning system currently used. In a study using the same vehicle model, a vehicle equipped with dual evaporation system had a higher leakage rate of refrigerant than a vehicle with a single evaporation system. It appears that the added fittings and joints of the dual evaporator system led to higher leakage rate. Besides, the analysis of the change in R-134a concentration under various car speed found that more refrigerant leaked under high speed(100km/hr) and but the volume of the wind did not affect to the variation of refrigerant leakage.

An Experimental Study on Vapor-Liquid Equilibria of HFC and HC Refrigerant Mixtures (탄화수소 및 불화탄화수소 혼합냉매의 기상-액상 평형에 관한 실험적 연구)

  • 강병복;김민수;김영일
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.11
    • /
    • pp.1031-1037
    • /
    • 2000
  • Isothermal vapor-liquid equilibrium(VLE) data have been obtained for the systems of propane(R290)+1,1,1,2-tetrafluoroethane(R134a) and 1,1,1,2-tetrafluoroethane(R134a)+isobutane(R60A) in the temperature range of 253.15 to 323.15K. Experiments were performed in a circulation type apparatus by injecting vapor through liquid pool using a magnetic pump. Both systems form azeotropes in the temperature range of this study. The experimental results were estimated with the Peng-Robinson equation of state. When the temperature-dependent binary interaction parameter was used in the Peng-Robinson equation of state, the absolute average deviation of the measured bubble point pressures from the values correlated by the Peng-Robinson equation was 0.65% and 0.78% for R290+R134a and R134a+600a, respectively. Azeotropic compositions for both systems were presented.

  • PDF

Design of an evaporator heat exchanger for R123 and R134a refrigerants (Rl23, R134a냉매 특성에 따른 증발기 설계)

  • 김익생
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.28 no.5
    • /
    • pp.368-374
    • /
    • 1999
  • 최근 세계적으로 환경보호에 대한 관심이 고조됨에 따라 기술개발 방향이 환경을 고려한 규정 및 장치에 제한을 받고 있다. 따라서 냉동 공조 기기에 사용되는 기존의 CFC계열 냉매가 오존층 파괴의 주 원임이 판명됨에 따라 환경 문제가 없는 HCFC계열인 R123와 HFC R134a로의 대체가 불가피하게 되었다.

  • PDF

A Prediction Model for Condensation of Zeotropic Refrigerant Mixtures Inside a Horizontal Smooth Tube (수평평활관내의 비공비 혼합냉매의 응축에 대한 예측모델)

  • ;;小山繁
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.4
    • /
    • pp.262-270
    • /
    • 2001
  • This paper deals with a prediction method for the condensation of ternary refrigerant mixture inside a horizontal smooth tube. Based on some reliable assumptions, the governing equations for the local heat and mass transfer characteristics are derived, and the prediction for the condensation of ternary zeotropic refrigerant mixtures composed of HFC32/HFC125/HFC134a, including R407C, is carried out. The local values of vapor quality, thermodynamic states at bulk vapor, vapor-liquid interface and bulk liquid, mass flux etc. are obtained for a constant wall temperature and a constant wall heat flux conditions, and the effects of the composition of HFC32/HFC125/HFC134a on heat transfer characteristics are examined. The prediction result is also compared with experimental data for condensation of ternary refrigerant mixtures. The predicted wall temperature distribution has a similar trend with experimental data but the predicted local heat transfer coefficients are 20-30% higher than the experimental data.

  • PDF