• 제목/요약/키워드: HFC-134a(R134a)

검색결과 38건 처리시간 0.136초

대체냉매 R430A를 적용한 정수기 냉동시스템의 성능 평가 (Performance of R430A on Refrigeration System of Domestic Water Purifiers)

  • 박기정;이요한;정동수;김경기
    • 설비공학논문집
    • /
    • 제21권2호
    • /
    • pp.109-117
    • /
    • 2009
  • In this study, thermodynamic performance of R430A is examined both numerically and experimentally in an effort to replace HFC134a used in the refrigeration system of domestic water purifiers. Even though HFC134a is used predominantly in such a system these days, it needs to be phased out in the near future in Europe and most of the developed countries due to its high global warming potential. To solve this problem, cycle simulation and experimental measurements are carried out with a new refrigerant mixture of 76%R152a124% R600a using actual domestic water purifiers. This mixture is numbered and listed as R430A by ASHRAE recently. Test results show that the system performance with R430A is greatly influenced by the amount of charge due to the small internal volume of the refrigeration system of the domestic water purifiers. With the optimum amount of charge of 21 to 22 grams, about 50% of HFC134a, the energy consumption of R430A is 13.4% lower than that of HFC 134a. The compressor dome and discharge temperatures and condenser center temperature of R430A are very similar to those of HFC134a at the optimum charge. Overall, R430A, a new long term environmentally safe refrigerant, is a good alternative for HFC134a requiring little change in the refrigeration system of the domestic water purifiers.

R435A를 적용한 정수기 냉동시스템의 성능평가 (Performance Evaluation of R435A on Refrigeration System of Water Purifiers)

  • 이요한;강동규;최현주;정동수
    • 한국태양에너지학회 논문집
    • /
    • 제33권1호
    • /
    • pp.15-23
    • /
    • 2013
  • In this study, thermodynamic performance of R435A is examined both numerically and experimentally in an effort to replace HFC134a used in the refrigeration system of domestic water purifiers. Even though HFC134a is used predominantly in such a system these days, it needs to be phased out in the near future in Europe and most of the developed countries due to its high global warming potential. To solve this problem, cycle simulation and experimental measurements are carried out with a new refrigerant mixture of 20%R152a/80%RE170 using actual domestic water purifiers. This mixture is numbered and listed as R435A by ASHRAE recently. Test results show that the system performance with R435A is greatly influenced by the amount of charge due to the small internal volume of the refrigeration system of the domestic water purifiers. With the optimum amount of charge of 21 to 22 grams, about 50% of HFC134a, the energy consumption of R435A is 11.8% lower than that of HFC134a. The compressor discharge temperature of R435A $8^{\circ}C$ lower than that of HFC134a at the optimum charge. Overall, R435A, a new long term environmentally safe refrigerant, is a good alternative for HFC134a requiring little change in the refrigeration system of the domestic water purifiers.

대체냉매 HFC-134a의 모세관 성능에 관한 수치해석적 연구 (Investigation of the Performance of the Alternative Refrigerant HFC-134a through Capillary tube : Numerical Analysis)

  • 김창년;박영무
    • 설비공학논문집
    • /
    • 제5권3호
    • /
    • pp.169-178
    • /
    • 1993
  • Performance charts of capillary tubes for R-134a are presented. The calculation is based on the one-dimensional, adiabatic flow through capillary tube. The length of capillary tube changes with inlet pressure, mass flux, inlet quality(or subcooling), and inside diameter. The length for R-134a is shorter by 12.5~23% than that for R-12 as mass flux varies, by 13~18.5% as inlet pressure changes, by 15~15.2% as inside diameter changes, and by 3.6~20% as subcooling(or quality) changes. In general, the length for R-134a is shorter than that for R-12 by 10~20%. Pressure drop per unit length for R-134a is greater than that for R-12 since specific volume of R-134a is larger that of R-12 and vapor pressure of R-134a is greater than that of R-12. Flash point of R-134a is ahead of that of R-12.

  • PDF

대체냉매의 2중관 응축기 열 및 물질전달과 성능평가 (Heat and Mass Transfer Characteristics and Performance Evaluation of a Double-Tube Condenser for an Alternative Refrigerant)

  • 이상무;박병덕;소산번
    • 설비공학논문집
    • /
    • 제14권6호
    • /
    • pp.468-476
    • /
    • 2002
  • This paper deals with heat and mass transfer characteristics and performance evaluation of a counter flow double-tube condenser for a multi-component refrigerant mixture. The local heat and mass transfer characteristics of ternary zeotropic refrigerant mixtures composed of HFC32/HFC125/HFC134a are evaluated for a counter flow double-tube condenser cooled by water. Then, the local values of vapor quality, thermodynamic states at bulk vapor, vapor-liquid interface and bulk liquid, heat flux and condensation mass flux are obtained. The heat exchange performance for ternary zeotropic refrigerant mixtures composed of HFC32/HFC125/HFC134a on the total pressure drop and the heat transfer characteristics are also compared with those for R404A, R410A, R502, R22, R32, Rl23 and R134a.

HFC-134a용 원심압축기의 성능시험 및 설계방안 (The Design and Performance Test of a Centrifugal Compressor for HFC-134a Refrigerant)

  • 신정관;김경훈;강신형
    • 설비공학논문집
    • /
    • 제22권3호
    • /
    • pp.139-148
    • /
    • 2010
  • A centrifugal compressor for HFC-134a has been newly designed and developed. Flow analysis using commercial programs was used to evaluate performance and internal flow of the impeller, inlet guide vane and diffuser etc. The purpose of this study is to establish the design theory necessary to the development of HFC-134a centrifugal compressors and to supply basic data related to design by reviewing design values and experimental values through the performance test. The compressor for HFC-134a was also investigated experimentally to check compression performance. The calculated data coincide the test results of compressor. The data obtained in the present study are useful for design of HFC-134a centrifugal compressors.

R-12, R-134a 및 R-22를 사용한 무급유식 스크롤압축기의 성능 비교 (A Performance Comparison of Oil-free Scroll Compressors with R-12, R-134a and R-22)

  • 박희용;박경우;박용일
    • 설비공학논문집
    • /
    • 제5권4호
    • /
    • pp.306-317
    • /
    • 1993
  • In this study, a performance comparison of scroll compressor for various refrigerants(CFC-12, HCFC-22 and HFC-134a) has been numerically carried out. The thermodynamic properties have been calculated by using the recent experimental equations and the performance has been investigated qualitatively at the same geometric specifications and operating conditions of scroll compressor. The results are as follows; HFC-134a has the highest compression ratio of 5.40. The mass flow rate of HCFC-22, which affects the cooling capacity of refrigerant system, is higher than that of other refrigerants. HFC-134a has the highest adiabatic efficiency in comparison with CFC-12 and HCFC-22.

  • PDF

HFC 순수냉매 및 혼합냉매의 모세관내에서 마찰에 의한 압력강하 (Frictional Pressure Drop of a Capillary Tube Flow of Pure HFC Refrigerants and Their Mixtures)

  • 장세동;노승탁
    • 설비공학논문집
    • /
    • 제7권4호
    • /
    • pp.589-599
    • /
    • 1995
  • The frictional pressure drop of a capillary tube flow is experimentally investigated for pure refrigerants such as R32, R125, and R134a and refrigerant mixtures such as R32/R134a(30/70 by mass percent), R32/R125(60/40), R125/R134a(30/70), and R32/R125/R134a(23/25/52). The binary interaction parameters for the calculation of viscosities of refrigerant mixtures are found based upon the data in the open literature. Several homogeneous flow models predicting the viscosity of two-phase region are compared to select the best model. Cicchitti's equation is known to be the most adequate for the prediction of the viscosity for refrigerant mixtures, which is used in the analysis of adiabatic capillary flows. A model for the prediction of the frictional pressure drop of single and two-phase flow is developed for refrigerant mixtures in this study. This model may be used to design and analyze the performance of a capillary tube in the refrigerating system.

  • PDF

HFC-134a용 1300RT급 원심압축기의 설계 및 성능시험 (Design and Performance Test of 1300RT Centrifugal Compressor for a HFC-134a Turbo-Chiller)

  • 고경태;최영민;신정관;김경훈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.672-677
    • /
    • 2001
  • This study has been conducted to design the high efficiency centrifugal compressor for a HFC-134a. The 2-stage centrifugal compressor consists of inlet guide vanes, two impellers with splitters, a deswirler, a vaneless diffuser and a volute casing. We have designed the high efficiency centrifugal compressor by applying the repeated design procedure including a meanline design, a 3D geometry generation of 1st and 2nd impellers etc. Also, a fluid dynamic calculation of impellers and deswirler have been conducting using a commercial code STAR-CD.

  • PDF

HFC134a 만액식 증발전열관 외부형상 변화에 따른 열전달 특성실험 (Experimental Study on Heat Transfer Characteristics of HFC134a for Enhanced Tubes Used in a Flooded Evaporator)

  • 양승우;이영수;정진희;강용태
    • 설비공학논문집
    • /
    • 제18권12호
    • /
    • pp.971-976
    • /
    • 2006
  • The objectives of this paper are to study the characteristics of pool boiling heat transfer for enhanced tubes used in the evaporator of turbo chiller and to provide a guideline for optimum design of an evaporator using HFC134a. Three different enhanced tubes are tested at 4 different saturation temperatures. The wall super heated temperature difference ranges from $0.5^{\circ}C\;to\;3.5^{\circ}C$. The refrigerant, HFC134a evaporates on the outside of the tube while the chilled water flows inside the tube. This study provides experimental heat transfer coefficients for evaporation on the enhanced tubes. It is found that the turbo-II tube provides the highest heat transfer coefficient.

R134a 터보냉동기용 원심압축기의 익단간극이 성능특성에 미치는 영향에 관한 수치해석적 연구 (Numerical Study on Tip Clearance Effect on Performance Characteristics of a Centrifugal Compressor for a R134a Turbo-Chiller)

  • 이경용;최영석;박운진
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.451-456
    • /
    • 2003
  • In this study, the overall performance and the effect of the tip leakage flow of the centrifugal compressor with the refrigerant HFC-l34a were numerically studied using CFX-TASCflow. To study the effect of a tip leakage flow, the numerical study of the overall performance of HFC-l34a centrifugal compressor with a cascade diffuser was preceded and compared with experimental result. Six different tip clearances were used to consider the influence of a tip clearance on performance. The tip leakage flow was illustrated for qualitative discussion. The results obtained in this study can be applied to the determination of the cold clearance.

  • PDF