• Title/Summary/Keyword: HFC 순수냉매

Search Result 6, Processing Time 0.021 seconds

Condensation Heat Transfer for Pure HFC Refrigerants and a Ternary Refrigerant Mixture Inside a Horizontal Tube (HFC 순수냉매 및 3성분 혼합냉매의 수평관내 응축열전달)

  • Oh, Jong-Taek;Hihara, Eiji
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.2
    • /
    • pp.233-240
    • /
    • 2000
  • An experimental study of condensation heat transfer was performed for pure refrigerants HFC32, HFCI25, and HFC134a, and a ternary refrigerant mixture of HFC32/125/134a (23/25/52wt%). The heat transfer coefficients were measured inside a horizontal smooth tube 5.8 mm I.D. and 8.0 m long. The refrigerant temperature at inlet was 40 $^{\circ}C$, and the mass flux was varied from 150 to 400 $kg/m^2s$. As for the pure refrigerants, the heat transfer coefficient of HFC32/125/l34a decreased as the quality decreased. In addition, the heat transfer coefficient of HFC32/l25/134a was about 20 % lower than HFC 134a at a low mass flux but showed no reduction at a high mass flux. The heat transfer coefficient of ternary refrigerant mixtures was 30% lower on the average than that of the pure refrigerant.

Frictional Pressure Drop of a Capillary Tube Flow of Pure HFC Refrigerants and Their Mixtures (HFC 순수냉매 및 혼합냉매의 모세관내에서 마찰에 의한 압력강하)

  • Chang, S.D.;Ro, S.T.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.4
    • /
    • pp.589-599
    • /
    • 1995
  • The frictional pressure drop of a capillary tube flow is experimentally investigated for pure refrigerants such as R32, R125, and R134a and refrigerant mixtures such as R32/R134a(30/70 by mass percent), R32/R125(60/40), R125/R134a(30/70), and R32/R125/R134a(23/25/52). The binary interaction parameters for the calculation of viscosities of refrigerant mixtures are found based upon the data in the open literature. Several homogeneous flow models predicting the viscosity of two-phase region are compared to select the best model. Cicchitti's equation is known to be the most adequate for the prediction of the viscosity for refrigerant mixtures, which is used in the analysis of adiabatic capillary flows. A model for the prediction of the frictional pressure drop of single and two-phase flow is developed for refrigerant mixtures in this study. This model may be used to design and analyze the performance of a capillary tube in the refrigerating system.

  • PDF

Pool Boiling Heat Transfer Correlation for Mixture Refrigerants (혼합냉매의 풀비등 열전달 상관식)

  • 고영환;김종곤;박진석;정동수;김영일
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.2
    • /
    • pp.122-133
    • /
    • 2001
  • Pool boiling heat transfer coefficients(HTCs) of HFC32/HFC134a, HFC125/HFC134a, HFC32/HFC125 and HFC32/HFC125/HFC134a were measured on a horizontal smooth tube. The experimental apparatus was specially designed to simulate the real heat transfer tube with the use of the secondary fluid of water. Data were taken in the order of decreasing heat flux starting at 80kW/$m^2\; and\; ending\; at\; 5kW/m^2$ in the pool temperature at $7^{\circ}C$. Test results showed that HTCs of these mixtures were 11~38% lower than those of ideal HTCs calculated by a linear mixing rule with pure fluids、 HTCs. Experimental data were compared with Stephan & Korner, Thome, Schlunder, Thome & Shakir、s correlations only to find that those correlations were not satisfactory for all fluids. Hence, a new correlation based on the present data was proposed which could be applied even to the ternary mixture. The correlation predicts the degradation of HTCs of mixtures well, showing a mean deviation of less than 15% for all the mixture data.

  • PDF

Pool Boiling Heat Transfer Correlation for Pure Refrigerants (순수냉매의 풀비등 열전달 상관식)

  • 고영환;김종곤;송길홍;정동수;김영일
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.10
    • /
    • pp.941-949
    • /
    • 2000
  • Pool boiling heat transfer coefficients (HTCs) of HCFC123, CFC11, HCFC142b, HFC134a, CFC12, HFC22, HFC125 and HFC32 on a horizontal smooth tube have been measured. The experimental apparatus is specially designed to simulate the real heat transfer tube with the use of the secondary fluid of water as a heat source rather than a conventional electric heat source. Data were taken in the order of decreasing heat flux starting at $80 ㎾/m^2\; and \;ending\; at\; 5㎾/m^2\;in\; the\; poo\;l temperature\; at\; 7^{\circ}C$, Test results showed that HTCs of HFC125, and HFC32 are 50~67% higher than those of HCFC22. It is also found that some of the popular pool boiling heat transfer correlations in the literature are not good to predict the HTCs of newly developed alternative refrigerants. A new correlation was developed by a regression analysis which is based upon the consistent data obtained in this study and it showed an excellent agreement with all experimental data having an absolute mean deviation of less than 10%.

  • PDF

Hydrate Phase Equilibria for the Ternary $N_2$ + HFC-134a + Water and $N_2$ + $SF_6$ + Water Mixtures (질소 + HFC-134a와 질소 + $SF_6$의 가스 하이드레이트 상평형)

  • Cha, In-Uk;Lee, Seung-Min;Lee, Ju-Dong;Lee, Gang-Woo;Seo, Yong-Won
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.213-215
    • /
    • 2008
  • 최근 지구온난화가 국제적인 이슈화되면서 온실가스의 효과적인 처리에 많은 관심이 집중되고 있다. 냉매로 주로 사용되는 HFC-134a와 절연제로 주로 사용되고 있는 $SF_6$는 각각 이산화탄소의 11,700배와 23,900배의 지구온난화지수를 가지는 온실가스이다. 본 연구에서는 이 두 물질의 효과적인 분리/회수를 위하여 가스 하이드레이트 형성을 이용한 방법을 제안하였다. 하이드레이트 형성법을 이용 할 경우 공정이 단순하고 저압에서 분리가 가능하므로 타 분리공정과의 경쟁이 가능할 것으로 예상된다. 본 실험은 275-290 K의 온도범위와 3 - 30 bar의 압력범위에서 질소 + HFC-134a (20, 40, 60, 80%)와 질소 + $SF_6$ (10, 30, 50, 70%)의 혼합기체를 사용하여 각 조성에 따른 하이드레이트(H)-물($L_W$)-기상 (V)의 3상 평형점을 측정하였다. HFC-134a 또는 $SF_6$의 조성이 낮은 혼합기체의 3상 평형점은 순수 질소의 3상 평형점에 비하여 주어진 온도에서 평형압력이 현저히 낮은 것을 볼 수 있었으며 HFC-134a 또는 $SF_6$의 조성이 증가할 수록 순수한 HFC-134a 또는 $SF_6$의 3상 평형점에 근접하는 것을 볼 수 있었다. 특히 $SF_6$는 다른 기체와 달리 하이드레이트의 생성/해리에 긴 시간이 필요하다는 것을 알 수 있었다. 본 실험에서 얻어진 결과는 하이드레이트를 이용한 HFC-134a와 $SF_6$ 분리 공정의 중요한 기초 자료가 되며 다른 혼합 기체의 분리 공정에도 응용될 수 있을 것이다.

  • PDF

Hydrate Phase Equilibria for the Gas Mixtures Containing HFC (수소불화탄소를 포함하는 혼합기체의 가스 하이드레이트 상평형)

  • Seo, Yong-Won;Lee, Seung-Min;Lee, Ju-Dong;Lee, Gang-Woo;Yamasaki, Akihiro;Kiyono, Fumio
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.581-584
    • /
    • 2007
  • (HFC(hydrofluorocarbon, 수소불화탄소)는 오존층 파괴 지수가 낮기 때문에 CFC(chlorofluorocarbon)의 대체 물질로 냉매와 발포제로 널리 사용되고 있는 물질이다. 하지만 HFC는 지구온난화 지수가 높은 기체이므로 대기중으로 방출되는 것을 막기 위해 분리/회수하여 재활용하는 것이 중요하다. 본 연구에서는 공기와 HFC의 혼합기체로부터 HFC만을 분리해 내는 방법으로 가스 하이드레이트 형성법을 제안하였다. 이 방법의 열역학적 타당성을 검증하기 위하여 질소+HFC-134a 혼합기체에 대하여 275-285 K의 온도 범위와 1-27 bar의 압력범위에 걸쳐서 가스 하이드레이트 상평형을 측정하였다. 질소는 가스 하이드레이트를 형성하기 위하여 0 $^{\circ}C$에서 150 bar 이상의 높은 압력이 필요한 반면 HFC-134a는 대기압에 가까운 낮은 압력이 필요하다. 두 기체의 평형 압력의 차가 크다는 것은 가스 하이드레이트 형성법을 이용할 경우 기체의 분리 효율이 매우 높다는 것을 나타낸다. 그리고, 본 실험을 통해서 얻어진 혼합기체의 하이드레이트상(H)-액상($L_W$)-기상(V)의 3상 평형선이 순수한 HFC-134a의 3상 평형선에 가깝게 위치하였다. 이는 가스 하이드레이트를 이용한 분리법이 낮은 압력에서 운전될 수 있음을 나타낸다. 이 분리법은 낮은 압력에서 운전되어 경제적일 뿐만 아니라 물 이외의 다른 매개체를 사용하지 않기 때문에 환경 친화적인 공정이라 할 수 있다.

  • PDF