• Title/Summary/Keyword: HFC

Search Result 375, Processing Time 0.023 seconds

Investigation of vapor-liquid equilibrium of HFC-32/143a and HFC-143a/134a systems (HFC-32/143a와 HFC-143a/134a계의 기-액상평형 실험에 관한 연구)

  • Kim, C.N.;Park, Y.M.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.1
    • /
    • pp.91-99
    • /
    • 1999
  • Vapor-liquid equilibrium apparatus is designed and set up. The equilibrium data of two binary systems, HFC-32/143a and HFC-143a/134a, are measured. Fifteen equilibrium data for HFC-32/143a and HFC-143a/134a systems are measured over the temperature range 263.15~283.15K at 10K interval and the composition range 0.10~0.80, respectively. And vapor-liquid equilibrium data are calculated using equation of state and correlation of activity coefficient and compared with the present data. Equation of state is used CSD and RKS equations and correlation of activity coefficient is used Margules' and Van Ness and Abbott's correlations. Real behavior of HFC-32/143a system has very large deviation with Raoult's rule which is ideal behavior. But real behavior of HFC-143a/134a system is similar to ideal behavior. The calculated data from CSD equation are compared with the data in the open literatures and the calculated data from REFPROP. In the results for REFPROP, the relative deviations of bubble point pressure for HFC-32/143a system are within -2.16~0.84% for CSD equation and within -0.20~1.10% for RKS equation. And the relative deviations of bubble point pressure for HFC-143a/134a system are within -0.45~0.12% and -0.20~2.8% for CSD and RKS equations, respectively.

  • PDF

Performance of HFC32/HFC125 Mixtures for Heat Pumps (HFC32/HFC125 혼합냉매의 히트펌프 성능 평가)

  • Kim, Wook-Jin;Kang, Dong-Gyu;Lee, Yo-Han;Jung, Dong-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.12
    • /
    • pp.791-798
    • /
    • 2011
  • In this study, performance of R410A(50%R32/50%R125) and HFC32/HFC125 mixture is measured to examine the effect of composition shift of R410A used for various air-conditioners and heat pumps. The composition of HFC32/HFC125 mixture varies from the reference composition of R410A ${\pm}10%$ with 5% interval. Tests carried out in a heat pump bench tester at the evaporation and condensation temperatures of $7/45^{\circ}C$ and $-7/41^{\circ}C$ for summer and winter conditions, respectively. Test results show that both the coefficient of performance (COP) and compressor power of the HFC32/HFC125 mixture have the maximum difference of 2.0% as compared to those of R410A. Compressor discharge temperatures of HFC32/HFC125 mixture are increased up to $6.7^{\circ}C$ as compared to that of R410A. The amount of charge for HFC32/HFC125 mixture vary within 5.6% as compared to that of R410A. Overall, performance of R410A is not appreciably affected by the composition shift of ${\pm}10%$ of R32 under both air-conditioning and heat pumping conditions.

Effects of Chicken Treated with Hwangki-Beni Koji Sauces on ROS Generating and Scavenging Related Enzyme Activities in Rats Fed with a High Fat and High Cholesterol Diet (황기홍국소스를 처리한 계육이 고지방 및 고콜레스테롤 식이 흰쥐의 ROS 생성 및 소거계 관련 효소의 활성에 미치는 영향)

  • Kim, Jae-Won;Kim, Soon-Dong;Youn, Kwang-Sup
    • Korean Journal of Food Science and Technology
    • /
    • v.42 no.5
    • /
    • pp.605-612
    • /
    • 2010
  • The dietary effects of chicken treated with Hwangki-Beni Koji sauce (HBS) on reactive oxygen species (ROS) generating and scavenging related enzyme activities in rats fed with a high-fat and high-cholesterol diet were investigated. The rats (five rats per group) were divided into a normal control diet group (NC), a high-fat and high-cholesterol diet control group (HFC), HFC plus base sauce-treated chicken supplemented diet group (HFC-BS), and a HFC plus HBStreated chicken supplemented diet group (HFC-HBS), and fed for 5 weeks. Total type T (T) and type O (O) hepatic xanthine oxidoreductase in HFC-HBS were 27.91-35.78% and 24.57-31.84% lower than those of HFC and HFC-BS, respectively. In HFC-HBS compared with HFC and HFC-BS, superoxidase dismutase activity was 62.89-64.50% higher, glutathione S-transferase activity was 19.29-25.17% higher, glutathione content was 25.11-53.30% higher, and lipid peroxide content was 20.29-24.19% lower. Therefore, chicken treated with HBS may prevent liver damage by the ROS formed from a high-fat and high -cholesterol diet.

Condensation Heat Transfer for Pure HFC Refrigerants and a Ternary Refrigerant Mixture Inside a Horizontal Tube (HFC 순수냉매 및 3성분 혼합냉매의 수평관내 응축열전달)

  • Oh, Jong-Taek;Hihara, Eiji
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.2
    • /
    • pp.233-240
    • /
    • 2000
  • An experimental study of condensation heat transfer was performed for pure refrigerants HFC32, HFCI25, and HFC134a, and a ternary refrigerant mixture of HFC32/125/134a (23/25/52wt%). The heat transfer coefficients were measured inside a horizontal smooth tube 5.8 mm I.D. and 8.0 m long. The refrigerant temperature at inlet was 40 $^{\circ}C$, and the mass flux was varied from 150 to 400 $kg/m^2s$. As for the pure refrigerants, the heat transfer coefficient of HFC32/125/l34a decreased as the quality decreased. In addition, the heat transfer coefficient of HFC32/l25/134a was about 20 % lower than HFC 134a at a low mass flux but showed no reduction at a high mass flux. The heat transfer coefficient of ternary refrigerant mixtures was 30% lower on the average than that of the pure refrigerant.

A Study on Characteristics of HFC-l34a and OS-l2a Refrigerant in Automobile Air-Conditioning System (자동차 에어컨용 냉매인 HFC-134a와 OS-12a의 성능 특성에 관한 연구)

  • 이종인;하옥남
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.3
    • /
    • pp.136-142
    • /
    • 2002
  • HFC-134a is currently used as the refrigerant in automobile air-conditioner, replacing the ozone depleting refrigerant CFC-12. Although HFC-l34a has no ozone depletion potential, it has a relatively high global warming potential, approximately 1300 tins that of CO$_2$ over a 100 year time horizon. Therefore, HFC- l34a does not seem to be a perfect alternative refrigerant due to high GWP. For this reason, non-azeotrope refrigerant mixture have been proposed as a long-term and drop-in alternative to HFC-l34a in the automobile air-conditioning system which has variable operating conditions with changes in RPM and pressure ratio. In this study,OS-l2a of which thermodynamic properties are similar to those of HFC-l34a is selected among the mixed refrigerant. HFC-l34a and OS-l2a are examined experimently by the performance test in the same automobile air-conditioning system.

Performance Analysis of an Collision Resolution Algorithm in HFC-CATV Network (HFC-CATV 망에서의 충돌해결알고리즘에 대한 성능분석)

  • 이수연;안정희
    • The Journal of the Korea Contents Association
    • /
    • v.2 no.3
    • /
    • pp.113-118
    • /
    • 2002
  • To provide interactive sonics in HFC(Hybrid Fiber Coax)-CATV network, there must be supported a MAC(Medium Access Control) protocol. It is wet known that collision can be occurred in the HFC upstream channel because it is shared by up to 500 users. Thus it needs the collision resolution algorithm. Consequently, this paper proposes the analysis mood to study stability of binary stack algorithm for adaptive collision resolution algorithm in HFC-CATV. Also, it compares a system throughput between IPP model and D-BMAP model.

  • PDF

Efficiency Optimization Control of IPMSM Drive using multi HFC (다중 HFC를 이용한 IPMSM 드라이브의 효율 최적화 제어)

  • Choi, Jung-Sik;Ko, Jae-Sun;Kang, Sung-Jun;Baek, Jeong-Woo;Jang, Mi-Geum;Kim, Soon-Young;Chung, Dong-Hwa
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.355-358
    • /
    • 2009
  • This paper proposes efficiency optimization control of IPMSM drive using multi hybrid fuzzy controller(HFC). The design of the speed controller based on fuzzy-neural network that is implemented using fuzzy control and neural network. The design of the current based on HFC using model reference and the estimation of the speed based on neural network using ANN controller. In order to maximize the efficiency in such applications, this paper proposes the optimal control method of the armature current. The controllable electrical loss which consists of the copper loss and the iron loss can be minimized by the optimal control of the armature current. The minimization of loss is possible to realize efficiency optimization control for the proposed IPMSM The optimal current can be decided according to the operating speed and the load conditions. This paper considers the design and implementation of novel technique of high performance speed control for IPMSM using multi HFC. Also, this paper proposes speed control of IPMSM using HFC1, current control of HFC2-HFC3 and estimation of speed using ANN controller. The proposed control algorithm is applied to IPMSM drive system controlled HFC, the operating characteristics controlled by efficiency optimization control are examined in detail.

  • PDF

Development of High Speed Multimedia Transmission System based on HFC Network (HFC 망에서의 고속 멀티미디어 전송시스템 개발)

  • Son, Byoung-Hee;Nahm, Eui-Seok;Yang, Hyo-Sik
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.12 no.2
    • /
    • pp.102-106
    • /
    • 2011
  • The transfer capability of HFC (Hybrid Fiber Coax) network is superior to xDSL. HFC network, however, is not suitable for transferring high quality video due to cable model interfaces. For the services of high quality IPIV or VOD, the extra exclusive downstream transfer system is required without upgrading pre-equipped cable modem and service capability. This paper is aimed to develop the extra exclusive downstream transfer system not changing existing cable modem system but providing same quality of services. This system is composed of the extra exclusive downstream IP-cable sender and modem. This sender and modem have 30 Mbps transfer capability and HDTV stream can be served in the Cable TV network using 21 Mbps HDTV transport stream.

Pool Boiling Heat Transfer Correlation for Mixture Refrigerants (혼합냉매의 풀비등 열전달 상관식)

  • 고영환;김종곤;박진석;정동수;김영일
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.2
    • /
    • pp.122-133
    • /
    • 2001
  • Pool boiling heat transfer coefficients(HTCs) of HFC32/HFC134a, HFC125/HFC134a, HFC32/HFC125 and HFC32/HFC125/HFC134a were measured on a horizontal smooth tube. The experimental apparatus was specially designed to simulate the real heat transfer tube with the use of the secondary fluid of water. Data were taken in the order of decreasing heat flux starting at 80kW/$m^2\; and\; ending\; at\; 5kW/m^2$ in the pool temperature at $7^{\circ}C$. Test results showed that HTCs of these mixtures were 11~38% lower than those of ideal HTCs calculated by a linear mixing rule with pure fluids、 HTCs. Experimental data were compared with Stephan & Korner, Thome, Schlunder, Thome & Shakir、s correlations only to find that those correlations were not satisfactory for all fluids. Hence, a new correlation based on the present data was proposed which could be applied even to the ternary mixture. The correlation predicts the degradation of HTCs of mixtures well, showing a mean deviation of less than 15% for all the mixture data.

  • PDF

A Study on Pore Structure of High-Fluidity Concrete using Lime Stone Powder and Fly-ash (석회석 미분말 및 플라이 애시를 사용한 고유동 콘크리트의 공극구조에 관한 연구)

  • Choi, Yun-Wang;Hooton, R.D.;Eom, Joo-Han
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.6 no.3
    • /
    • pp.118-125
    • /
    • 2011
  • The size and distribution of concrete void was one among the factor determining durability of concrete. Recently, there was a lot of researches related to the High-Fludity Concrete(HFC) with field applications. However, the research about the void structure having an effect on durability of concrete is insufficient. Therefore, in this research, Conventional Concrete(CC) and HFC using lime stone powder and fly-ash of 30 MPa range was manufactured and observed the void structure of CC and HFC. Experimental results showed that average pore diameter in the case of the 30 MPa range HFC was to be lower than CC and SEM analyzed result, HFC was firmer inner structure than CC.

  • PDF