• 제목/요약/키워드: HF(High Frequency)

검색결과 282건 처리시간 0.025초

HF-CT센서를 이용한 고분자애자의 오손특성 (Contamination Characteristics of Polymer Insulator using High Frequency Current Transformer)

  • 박재준
    • 정보학연구
    • /
    • 제8권4호
    • /
    • pp.1-7
    • /
    • 2005
  • Investigations of high frequency current transformer(HF-CT) waveform characteristics of the surface leakage on kaolin polluted EPDM polymer insulators have been performed. This work is part of a program aimed at examining the potential for HF-CT waveform characteristics analysis to provide information about the environment contaminants and environment condition of polymer insulators. The investigation reported examined the HF-CT waveform characteristics at high frequencies. The use of high frequency measurements for on-line applications reduces electrical inference. This work was peformed utilizing HF-CT to monitor of surface polluted discharge. It was found that HF-CT waveform frequency spectrum, magnitude depend on importantly the duration of the surface discharge activity.

  • PDF

극초단파치료기를 사용하는 물리치료실의 환경이 물리치료사의 인체자율신경계에 미치는 영향 (The Effect of the Physical Therapy Treatment Room Environment Using Microwave Diathermy on the Autonomic Nervous System of Human Body)

  • 신한기;이태규;전재윤;김주승;강종호
    • 대한물리의학회지
    • /
    • 제10권1호
    • /
    • pp.37-43
    • /
    • 2015
  • PURPOSE: The purpose of this study is to investigate the effect of the physical therapy treatment room environment using microwave diathermy on the autonomic nervous system of human body. METHODS: Participants were 24 healthy adults. Standard deviation of all normal R-R intervals(SDNN), root mean square of successive differences(RMSSD), low frequency(LF), high frequency(HF), LF/HF ratio were compared in microwave irradiation and non-irradiation group. Data were analyzed in Wilcoxon's signed-ranks test and Mann-Whitney U test. RESULTS: Standard deviation of all normal R-R intervals (SDNN), root mean square of successive differences (RMSSD), low frequency(LF), high frequency(HF), LF/HF ratio were not significantly different in microwave irradiation group. Standard deviation of all normal R-R intervals(SDNN), root mean square of successive differences (RMSSD), low frequency(LF), high frequency(HF), LF/HF ratio were not significantly different in microwave non-irradiation group. Standard deviation of all normal R-R intervals(SDNN), root mean square of successive differences (RMSSD), low frequency(LF), high frequency(HF), LF/HF ratio were not significantly different between two groups. CONCLUSION: There was no significant change in the sympathetic nervous system and parasympathetic nervous system regardless of the presence of microwave irradiation. There was no significant change in the autonomic nervous system adaptability regardless of the presence of microwave irradiation.According to this study, microwave diathermy does not have significant effect on the autonomic nervous system.Future study is necessary to investigate the long term effect of the physical therapy treatment room environment using microwave diathermy on the autonomic nervous system of the human body.

양릉천(陽陵泉) 고주파(高周波) 전침자극(電鍼刺戟)이 $CCl_4$로 유발된 흰 쥐의 간손상(肝損傷)에 미치는 영향(影響) (A Study on the Effect of High Frequency Electroacupuncture at Yanglingquan(GB34) on $CCl_4$-intoxicated Rats)

  • 허윤경;이현
    • Korean Journal of Acupuncture
    • /
    • 제26권1호
    • /
    • pp.111-123
    • /
    • 2009
  • Objective : The purpose of this study is to observe the effect of high frequency electro-acupuncture (hf-EA) at Yanglingquan(GB34) on $CCl_4$-induced liver damage in rats. Methods : The author performed several experimental items, including measurements of body weight and liver weight, hematological analysis for RBC, WBC, PLT, hemoglobin, lymphocytes, neutrophils, monocytes and biochemical assays for ALT, AST, ALP and total cholesterol in serum, and histological analysis of liver tissue. Results & Conclusion : 1. WBC level in blood was slightly reduced by acupuncture and hf-EA at GB34. 2. Lymphocyte level in blood was decreased by $CCl_4$-intoxication and significantly increased by acupuncture and hf-EA at GB34. 3. Neutrophils level in blood was slightly reduced by acupuncture and hf-EA at GB34. 4. ALT and AST in serum were reduced significantly by acupuncture and hf-EA at GB34. 5. The pathological changes of liver tissue induced by $CCl_4$ was reduced by hf-EA at GB34. 6. No significant difference was found between the effects of acupuncture and hf-EA on CCl4-induced liver damage in rats.

  • PDF

Parallel Connected High Frequency AC Link Inverters Based on Full Digital Control

  • Sha, Deshang;Guo, Zhiqiang;Deng, Kai;Liao, Xiaozhong
    • Journal of Power Electronics
    • /
    • 제12권4호
    • /
    • pp.595-603
    • /
    • 2012
  • This paper presents a full digital control strategy for parallel connected modular inverter systems. Each modular inverter is a high frequency (HF) AC link inverter which is composed of a HF inverter and a HF transformer followed by a cycloconverter. To achieve equal sharing of the load current and to suppress the circulating currents among the modules, a three-loop control strategy, consisting of a common output voltage regulation (OVR) loop, individual circulating current suppression (CCS) loops and individual inner current tracking (ICT) loops, is proposed. The ICT loops are implemented with predictive current control from which high precision current tracking can be obtained. The effectiveness of the proposed control strategy is verified by simulation and experimental results from parallel connected two full-bridge HF AC link inverter modules.

Estimation of Ocean Current Velocity near Incheon using Radarsat-1 SAR and HF-radar Data

  • Kang, Moon-Kyung;Lee, Hoon-Yol
    • 대한원격탐사학회지
    • /
    • 제23권5호
    • /
    • pp.421-430
    • /
    • 2007
  • This paper presents the results of the ocean surface current velocity estimation using 6 Radarsat-1 SAR images acquired in west coastal area near Incheon. We extracted the surface velocity from SAR images based on the Doppler shift approach in which the azimuth frequency shift is related to the motion of surface target in the radar direction. The Doppler shift was measured by the difference between the Doppler centroid estimated in the range-compressed, azimuth-frequency domain and the nominal Doppler centroid used during the SAR focusing process. The extracted SAR current velocities were statistically compared with the current velocities from the high frequency(HF) radar in terms of averages, standard deviations, and root mean square errors. The problem of the unreliable nominal Doppler centroid for the estimation of the SAR current velocity was corrected by subtracting the difference of averages between SAR and HF-radar current velocities from the SAR current velocity. The corrected SAR current velocity inherits the average of HF-radar data while maintaining high-resolution nature of the original SAR data.

High-Frequency Zero Current Soft Switching Inverter with Pulse Density Modulation for Induction Heated Roller

  • Kang, Shin-Chul;Mun, Sang-Pil
    • 조명전기설비학회논문지
    • /
    • 제22권7호
    • /
    • pp.49-57
    • /
    • 2008
  • This paper presents a voltage source type half-bridge series resonant high frequency (HF) inverter for induction heated fixing roller in copy machines. This high-frequency inverter works under zero current soft switching (ZCS) commutation and has wide power regulation range due to employing a pulse density modulation (PDM) scheme. Transient and steady state operating modes of the inverter are presented in this paper together with its PDM-based power regulation system. Experimental operating performances of the developed HF-ZCS inverter as well as power losses and actual efficiency are discussed and compared with computer simulation results.

박스용 UHF-HF 이중대역 RFID 태그 설계 (UHF-HF Dual-Band RFID Tag Antenna Design for Boxes)

  • 남세현;강주원;정유정
    • 한국전자파학회논문지
    • /
    • 제29권2호
    • /
    • pp.93-98
    • /
    • 2018
  • 본 논문은 스마트 RFID(Radio Frequency Identification) 박스에 920 MHz UHF(Ultra High Frequency) 대역과 13.56 MHz HF(High Frequency) 대역의 NFC(Near Field Communication)가 사용 가능한 태그를 박스 자체에 임베디드시켜서 설계하였다. 이중대역 태그에서 HF 대역은 NFC를 사용하여 일반인이 스마트 폰으로 인식과 검수를 가능하게하고, UHF RFID 대역은 상자 속에 물건 내용과 물류 이동을 파악하기 위함이다. 박스의 유전율을 측정하여 simulation에 반영하였으며, HF 대역은 NFC가 가능한 NXP사의 Ntag213칩을 사용하여 Loop형 안테나로 설계하였다. UHF 태그는 Alien사의 Higgs-3 칩을 사용하였고, HF 태그의 주변 가장자리에 위치하도록 설계하여 HF 태그와 상호 작용이 최소가 되도록 설계 하였으며, 본 태그는 두 대역에서 사용이 가능하므로 내용물의 검수와 물류 정보를 효과적으로 파악이 가능하다.

Bonding Performance of Adhesives with Lamina in Structural Glulam Manufactured by High Frequency Heating System

  • Kim, Keon-Ho;Kim, Se-Jong;Yang, Sang-Yun;Yeo, Hwanmyeong;Eom, Chang-Deuk;Shim, Kugbo
    • Journal of the Korean Wood Science and Technology
    • /
    • 제43권5호
    • /
    • pp.682-690
    • /
    • 2015
  • The bonding performance of two types of wood adhesives, namely phenol-resorcinol-formaldehyde (PRF) resin and melamine-urea-formaldehyde (MUF) resin for glued laminated timber manufactured by high frequency (HF) heating was evaluated. The HF heating system consists of HF oscillator with dielectric heating system for curing adhesives, and hydraulic press system for clamping glued laminated timber. The designed frequency and output power of the HF system was as 5 MHz and 60 kW, respectively. To verify dielectric heating mechanism under HF oscillation, the heat loss factors of laminae and adhesives were measured. The results show that it is possible to selectively heat adhesives for their curing due to the remarkably higher loss factor of the adhesives than those of wood laminae. The temperature of adhesive in the bonding line reached up to the set temperature within a few seconds by high frequency oscillating, which advanced the curing of adhesive afterwards. The bonding performance, such as shear strength of bonding line, water soaking delamination, and boiling water soaking delamination of PRF resin met the requirement of Korean Standard (KS), however the MUF resin did not meet the KS requirement of boiling water soaking delamination. These results indicate that the HF heating system is successful to manufacture glued laminated timbers with PRF resins to meet the bonding requirements.

경피신경전기자극이 자율신경계에 미치는 영향 (The Influence of Transcutaneous Electrical Stimulation on Autonomic Function)

  • 강종호;김용남
    • 대한물리의학회지
    • /
    • 제4권4호
    • /
    • pp.241-247
    • /
    • 2009
  • Purpose:The purpose of this study is to investigate the effect of transcutaneous electrical stimulation on autonomic nervous system using heart rate variability analysis. Methods:31 subjects were evaluated with HRV before and after a single high-frequency TENS for 15minutes treatment. The standard deviation of all the normal RR-interval(SDNN) and lower frequency/high frequency ratio(LF/HF ratio) were recorded with TAS-9. Results:After single TENS treatment, autonomic adaptation as analyzed by SDNN was increased from $42.47\pm12.96$ to $4.43\pm16.76$(p>0.05) and autonomic balance as analyzed by LF/HF ratio was increased from $1.4\pm0.45$ to $1.45\pm0.41$(p>0.05). Conclusion:In this study, SDNN and LF/HF ratio changed in health young students as a result of single TENS treatment. But there is no significant difference between pre-treatment and post-treatment of SDNN and LF/HF ratio.

  • PDF

음향방출법에 의한 SM45C 고주파 열처리 강의 기계적 특성 평가 (The Estimation of Mechanical Properties of the High Frequency Induction Hardening SM45C Steel by Acoustic Emission)

  • 이장규;김봉각
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2009년도 추계학술대회
    • /
    • pp.471-481
    • /
    • 2009
  • This study is deal with the high frequency induction hardening (HF at $850^{\circ}C$, 120kHz & 50kW condition) SM45C steel. (1) The HF specimen which was tempered at $150^{\circ}C$, did not appear any tempering effect. A brittle fracture occurred at rounded area of the tensile specimen. AE amplitude distribution showed between 45~60dB. (2) The HF specimen which was tempered at $300^{\circ}C$, slip and fracture occurred at the hole area of the tensile specimen. As it passes the yield point, the AE energy increased intermittently and AE amplitude distribution showed between 70~85dB. In addition, after the maximum tensile load, it showed high amplitude and energy distribution. The AE amplitude showed between 45~70dB. (3) The HF specimen which was tempered at $450^{\circ}C$, a brittle fracture occurred as if it is torn in the direction of $45^{\circ}$ on parallel area over the both sides of the tensile specimen, which led to several peak to be appeared in AE energy. It was found that the AE amplitude was relatively low and the AE energy was high.

  • PDF