• Title/Summary/Keyword: HEXA

Search Result 158, Processing Time 0.069 seconds

Hexa-Band Hybrid MIMO Antenna for the Mobile Phone Surrounding Ground (접지에 둘러싸인 휴대폰을 위한 6중 밴드 하이브리드 MIMO 안테나)

  • Lee, Kyeong-Ho;Son, Taeho
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.4
    • /
    • pp.357-364
    • /
    • 2015
  • In this paper, we designed and implemented a PIFA(Planar Inverted F Antenna) + IFA(Inverted F Antenna) hybrid MIMO(Multi Input Multi Output) antenna for the hexa mobile communication service band. By the simultaneous operation both PIFA and IFA using the coupled feeding structure, we tried for application to modern mobile phones that have large ground size. A PIFA is applied to the ground area, and an IFA is applied to no ground small space on top of the phone. A diagonal fed MIMO antenna is implemented PCB embedded type without antenna carrier component. Implemented antenna on the bare board measured within 3 : 1 for VSWR under hexa mobile communication band as CDMA, GSM900, DCS, KPCS, USPCS, and WCDMA. Measured average gains and efficiencies were -5.19~-3.16 dBi and 30.27~48.26 % for the CDMA, GSM900 band, and -9.50~-5.19 dBi and 11.23~30.28 % for the DCS, KPCS, USPCS, WCDMA band. It's shown that studied antenna can be applied to the antenna for the modern mobile phone.

Evaluation on the Efficiencies of Local Exhaust Systems and Airborne Concentrations of Total Chromium, Hexa-valent Chromium and Nickel in Some Electroplating Plants (일부 영세 도금사업장의 국소배기성능과 공기중 총크롬, 6가 크롬 및 니켈농도와의 관계분석)

  • Park, D.U.;Park, D.Y.;Shin, Y.C.;Oh, S.M.;Chung, K.C.
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.3 no.1
    • /
    • pp.68-77
    • /
    • 1993
  • To evaluate efficiencies of the local exhaust systems installed in chromiun and nickel eletroplating tanks, specifications of each tank and general performances of the local exhaust systems were measured in 16 electroplating plants from July 3 to November 24, 1992. Airborne concentrations of total chromium, hexa-chromium and nickel were also measured, Most of the local exhaust systems installed in electroplating plants were inadequately designed. Average capture velocities of local exhaust systems in chromium and nickel tanks were 0.45 m/sec and 0.29 m/sec. Average slot velocities in chromium and nickel tanks were 7.30 m/sec and 2.87 m/sec repectively. Both average capture and solt velocities were in noncompliance with the standards recommened by American Conference of Governmental Industrial Hygienists (ACGIH) and National Institute for Occupational Safety and Health (NIOSH), Exhausted air volume was insufficient in all local exhaust systems surveyed. Worker exposure levels to total chromium, hexa-chromium and nickel were $43.0{\mu}g/m^3$, $1.7{\mu}g/m^3$ and $9.3{\mu}g/m^3$, which were below the Korean Standard and U.S. Occupational Health and Safety Administration (OHSA) Permissible Exposure Limit(REL). However, Worker exposure level to hexa-chromium exceeded the NIOSH Recommended Exposure Limit(REL) of $1{\mu}g/m^3$. As the result of Scheffee's multiple comparions, worker exposure levels to all metals were significantly different between two groups by the management state of existing local exhaust systems (p<0.05). However, Difference between a group with local exhaust systems which were poorly managed and another group without local exhaust system was satatistically non-significant.

  • PDF

An association between diet quality index for Koreans (DQI-K) and total mortality in Health Examinees Gem (HEXA-G) study

  • Lim, Jiyeon;Lee, Yunhee;Shin, Sangah;Lee, Hwi-Won;Kim, Claire E;Lee, Jong-koo;Lee, Sang-Ah;Kang, Daehee
    • Nutrition Research and Practice
    • /
    • v.12 no.3
    • /
    • pp.258-264
    • /
    • 2018
  • BACKGROUND/OBJECTIVES: Diet quality scores or indices, based on dietary guidelines, are used to summarize dietary intake into a single numeric variable. The aim of this study was to examine the association between the modified diet quality index for Koreans (DQI-K) and mortality among Health Examinees-Gem (HEXA-G) study participants. SUBJECTS/METHODS: The DQI-K was modified from the original diet quality index. A total of 134,547 participants (45,207 men and 89,340 women) from the HEXA-G study (2004 and 2013) were included. The DQI-K is based on eight components: 1) daily protein intake, 2) percent of energy from fat, 3) percent of energy from saturated fat, 4) daily cholesterol intake, 5) daily whole-grain intake, 6) daily fruit intake, 7) daily vegetable intake, and 8) daily sodium intake. The association between all-cause mortality and the DQI-K was examined using Cox proportional hazard regression models. Hazard ratios and confidence intervals were estimated after adjusting for age, gender, income, smoking status, alcohol drinking, body mass index, and total energy intake. RESULTS: The total DQI-K score was calculated by summing the scores of the eight components (range 0-9). In the multivariable adjusted models, with good diet quality (score 0-4) as a reference, poor diet quality (score 5-9) was associated with an increased risk of all-cause mortality (hazard ratios = 1.23, 95% confidence intervals = 1.06-1.43). Moreover, a one-unit increase in DQI-K score resulted in a 6% higher mortality risk. CONCLUSIONS: A poor diet quality DQI-K score was associated with an increased risk of mortality. The DQI-K in the present study may be used to assess the diet quality of Korean adults.

A New Device and Procedure for Kinematic Calibration of Parallel Manipulators

  • Rauf, Abdul;Kim, Sung-Gaun;Ryu, Je-Ha
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1615-1620
    • /
    • 2003
  • Kinematic calibration is a process whereby the actual values of geometric parameters are estimated so as to minimize the error in absolute positioning. Measuring all components of Cartesian posture, particularly the orientation, can be difficult. With partial pose measurements, all parameters may not be identifiable. This paper proposes a new device that can identify all kinematic parameters with partial pose measurements. Study is performed for a six degree-of-freedom fully parallel Hexa Slide manipulator. The device, however, is general and can be used for other parallel manipulators. The proposed device consists of a link with U joints on both sides and is equipped with a rotary sensor and a biaxial inclinometer. When attached between the base and the mobile platform, the device restricts the end-effector's motion to five degree-of-freedom and can measure position of the end-effector and one of its rotations. Numerical analyses of the identification Jacobian reveal that all parameters are identifiable. Computer simulations show that the identification is robust for the errors in the initial guess and the measurement noise. Intrinsic inaccuracies of the device can significantly deteriorate the calibration results. A measurement procedure is proposed and formulations of cost functions are discussed to prevent propagation of the inaccuracies to the calibration results.

  • PDF

The Role of (Chloro-) Phenols in the Formation of Polychlorinated Dibenzofurans in Municipal Waste Incinerators

  • Ryu, Jae-Yong;Jang, Seong-Ho
    • Journal of Environmental Science International
    • /
    • v.16 no.1
    • /
    • pp.9-19
    • /
    • 2007
  • Comparing predicted PCDF isomer patterns with those obtained from a municipal waste incinerator assessed the role of two-phenol condensation pathways in the formation of PCDFs. Complete PCDF homologue and isomer distributions were obtained from a Fluidized Bed Incinerator (FBI). Two-phenol condensation model, dependent only on the distributions of phenols, was developed to predict the PCDF congeners produced from phenol precursors. R-squared values from linear correlations are presented for the dichlorinated through hexa-chlorinated isomer distributions between measured and predicted. They range from 0.00: to 0.1 far the di-chlorinated through hexa-chlorinated isomer sets. Agreement between predicted and measured PCDF isomer distributions was very poor for all homologues. Two-phenol condensation pathways are not likely to be the pre-dominant pathways in the formation of PCDF in a FBI. However, dibenzofuran (DF) is likely to be produced from a condensation of two phenols. This work demonstrates the use of PCDF homologue and isomer patterns for testing PCDF formation mechanism from two-phenol condensation pathways in municipal waste incinerators.

Calibration of Parallel Manipulators using a New Measurement Device (새로운 측정장비를 이용한 병렬구조 로봇의 보정에 관한)

  • Rauf, Abdul;Kim, Sung-Gaun;Ryu, Je-Ha
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1494-1499
    • /
    • 2003
  • Kinematic calibration is a process whereby the actual values of geometric parameters are estimated so as to minimize the error in absolute positioning. Measuring all components of Cartesian posture, particularly the orientation, can be difficult. With partial pose measurements, all parameters may not be identifiable. This paper proposes a new device that can be used to identify all kinematic parameters with partial pose measurements. Study is performed for a six degree-of-freedom fully parallel Hexa Slide manipulator. The device, however, is general and can be used for other parallel manipulators. The proposed device consists of a link with U joints on both sides and is equipped with a rotary sensor and a biaxial inclinometer. When attached between the base and the mobile platform, the device restricts the end-effector's motion to five degree-of-freedom and can measure position of the end-effector and one of its rotations. Numerical analyses of the identification Jacobian reveal that all parameters are identifiable. Computer simulations show that the identification is robust for the errors in the initial guess and the measurement noise.

  • PDF

Effect of Sealing Materials and Parameters on the Corrosion Resistance of HVOF-Sprayed CrC-NiCr Coatings (실링재 및 실링방법이 HVOF 용사된 CrC-NiCr 코팅의 내식성에 미치는 영향)

  • Jeong, Younghun;Nam, Uk-Hee;Byon, Eungsun;Kang, Tae-Il;Kang, Chung-Yun
    • Journal of the Korean institute of surface engineering
    • /
    • v.47 no.6
    • /
    • pp.323-329
    • /
    • 2014
  • Effects of sealant and sealing procedure on corrosion resistance of high velocity oxy-fuel (HVOF) sprayed coatings were studied. HVOF-sprayed CrC-20NiCr coatings were sealed using three commercial sealants based on phenolics and epoxy. Penetration depth of sealants, measured by fluorescent microscope technique, was between $19{\mu}m$ and $340{\mu}m$ depending on sealant, sealing condition or sealing procedure. It was found that sealing on rotation status was more effective than that on stationary specimen due to the Coriolis effect of fluid in pores of the coating. From the CASS results, corrosion resistance of properly sealed CrC-20NiCr coatings was equal to that of hexa-valent chromium plating.

Effect of sodium hexa-meta phosphate as pore-sealing agent on the corrosion performance of Al-Zn coating deposited by twin-wire arc thermal spray process in 3.5 wt.% NaCl solution (3.5 중량% NaCl 용액에서 쌍선 아크 용사 공정으로 증착된 Al-Zn 코팅의 부식 성능에 대한 기공 밀봉제로서의 헥사메타인산나트륨의 영향)

  • Singh, Jitendra Kumar;Adnin, Raihana Jannat;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.81-82
    • /
    • 2022
  • Al and Zn are used to protect the steel structures from corrosion. In the present studies, 15Al-85Zn alloy wires has been used for the deposition of coating by arc thermal spray process. Moreover, this process of coating exhibited severe defects formation, therefore, this coating was post-treated with different concentrations i.e. 0.05, 0.1 and 0.5M sodium hexa meta phosphate (Na6[(PO3)6]: SHMP) to fill to defects of deposited coatings and assessed their corrosion resistance in 3.5 wt.% NaCl solution with exposure periods. After the treatment, the porosity of the coating reduced significantly by formation of composite oxide films onto the coating surface. Initially, 0.5 M SHMP treated coating exhibited highest in total impedance due to significant reduction of porosity but once the exposure periods are extended, the composite oxides are dissolved, thus, total impedance is decreased.

  • PDF

Effects of Phosphate Complex on the Functional Properties of Fish Meat Paste (혼합 인산염의 첨가가 어류연육의 기능적 성질에 미치는 영향)

  • Kim, Dong-Soo;Kim, Young-Myung;Kim, Il-Hwan;Lee, Byung-Joon
    • Korean Journal of Food Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.253-257
    • /
    • 1985
  • Effects of four kinds of phosphate complex on the water holding capacity (W.H.C) and protein solubility of yellow-corvenia (Pseudosciance manchurica) and hair tail (Tichurus lepturus) meat paste were investigated. The formulations of four kinds of phosphate complex employed to this experiment were made by mixing several phosphates such as sodium polyphosphate, sodium pyro-phosphate, sodium acid pyro-phosphate, potassium pyro-phosphate, sodium tetra meta-phosphate, sodium ultra meta-phosphate and sodium hexa meta-phosphate, and monoglyceride at different mixture ratios. Among the four kinds of phosphate complex, phosphate B complex which was formulated by mixing sodium poly-phosphate 50%, sodium pyrophosphate 20%, sodium tetra meta-phosphate 20%, sodium acid pyrophosphate 5% and sodium ultra meta-phosphate 5% was most effective on enhancing the W.H.C and protein solubility of yellow corvenia meat paste, and in case of hair tail meat paste, phosphate C complex which was formulated by mining sodium poly-phosphate 40%, sodium pyro-phosphate 30%, potassium pyro-phosphate 15%, sodium tetra meta-phosphate 10%, and sodium hexa meta-phosphate 5% was more effective than other phosphate complex, and their optimum addition level was 0.4% respectively in weight of fish meat paste. Texture characteristics such as hardness, cohesiveness, and springiness value of Kamaboko (fish meat paste product) were evaluated as best when 0.3% of phosphate B complex was added. The optimum cooking condition of Kamaboko to get good texture was heating for 45 mimutes at $85^{\circ}C$.

  • PDF