• Title/Summary/Keyword: HESS

Search Result 107, Processing Time 0.023 seconds

Compound-Type Hybrid Energy Storage System and Its Mode Control Strategy for Electric Vehicles

  • Wang, Bin;Xu, Jun;Cao, Binggang;Li, Qiyu;Yang, Qingxia
    • Journal of Power Electronics
    • /
    • v.15 no.3
    • /
    • pp.849-859
    • /
    • 2015
  • This paper proposes a novel compound-type hybrid energy storage system (HESS) that inherits the unique advantages of both battery/supercapacitor (SC) and the SC/battery HESSs for electric vehicles (EVs). Eight operation modes are designed to match this system. A mode control strategy is developed for this HESS on the basis of these modes, and five classes of operation modes are established to simplify this strategy. The mode control strategy focuses on high operating efficiency and high power output. Furthermore, the compound-type HESS is designed such that the SC is the main priority in braking energy absorption. Thus, this HESS can operate efficiently and extend battery life. Simulation results also show that the compound-type HESS can not only supply adequate power to the motor inverter but can also determine suitable operation modes in corresponding conditions. Experimental results demonstrate that this HESS can extend battery life as well. The overall efficiency of the compound-type HESS is higher than those of the battery/SC and the SC/battery HESSs.

Hunt-Hess and Fisher Grades as Predicting Factors for Chronic Hydrocephalus in Surgically Treated Ruptured Aneurysm (수술적 치료를 받은 파열성 뇌동맥류환자에서의 예후와 뇌실-복강 단락술의 예측인자로써의 Hunt-Hess Grade와 Fisher Grade)

  • Hong, Chang Ki;Park, Chong Oon;Hyun, Dong Keun;Ha, Young Soo
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.1
    • /
    • pp.60-65
    • /
    • 2001
  • Objective : The popular grading systems in use, such as Hunt-Hess grade and Fisher scale score, are based primarily on the patient's clinical conditions or computerized tomography score after aneurysmal subarachnoid hemorrhage(SAH). The author investigated whether the need for ventriculoperitoneal(VP) shunt for chronic hydrocephalus and outcome can be predicted by Hunt-Hess grade and Fisher scale. Methods : A series of 146 patients admitted to our hospital from August 1991 to July 1999, who presented with SAH and underwent craniotomy for aneurysm clipping were studied retrospectively. Chronic hydrocephalus was defined as clinically and radiographically demonstrated hydrocephalus that lasted 2 weeks or longer after initial hemorrhage which required shunting. Patients were evaluated based on following factors : Hunt-Hess grade, Fisher scale, age, sex, hypertension, aneurysm location, and intervals from aneurysm rupture to operation. Results : The overall mortality rate of the study group was 8.2%. Hunt-Hess grade(p=0.001) or Fisher scale (p=0.001) at all pretreatment times was significantly correlated with outcome. In addition, there was an increased risk of poor outcome in older age(65<). However, there were statistically no significant relationship between outcome and sex, location of aneurysm, hypertension, and interval from aneurysmal rupture to operation(p>0.05). Of 134 surviving patients, 16 patients(12%) underwent VP shunt placement secondary to chronic hydrocephalus. Hunt-Hess grade(p=0.001) is more predictive of chronic hydrocephalus than Fisher scale(p=0.146). Aneurysm location was significantly correlated with development of chronic hydrocephalus (p<0.05), without significant correlations in sex, age, hypertension. IVH, and ICH. Conclusion : This study suggests that there is a high clinical correlation between outcome and Hunt-Hess grades and Fisher scales on admission, but Hunt-Hess grade is more predictive for chronic hydrocephalus than Fisher scale. In addition, age(<65 yrs) is the significant factor for prediction of outcome. There was a trend of increasing risk for chronic hydrocephalus according to aneurymal location.

  • PDF

The Outcome of Urgent Surgery for Hunt-Hess Grade IV Patients with Ruptured Intracranial Aneurysm (두개강내 동맥류 파열로 인한 Hunt-Hess Grade IV 환자에서의 응급수술의 결과)

  • Oh, Jun Gyu;Kang, Hee In;Moon, Byung Gwan;Lee, Seung Jin;Kim, Joo Seung
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.8
    • /
    • pp.1013-1018
    • /
    • 2001
  • Objective : About 40% of patients who admit to the hospital after subarachnoid hemorrhage are poor clinical grade(Hunt-Hess grade IV, V). The majority of these patients have been excluded from early, aggressive treatment. The current study was undertaken to evaluate the outcome of urgent surgery for Hunt-Hess grade IV aneurysmal subarachnoid hemorrhage. Materials and Methods : We reviewed hospital records and radiographic studies of 36 patients who were Hunt-Hess grade IV among 201 cases with ruptured intracranial aneurysm admitted between Sep. 1995 and Dec. 2000. Operated patients were treated with urgent angiography and surgery within 24 hours of presentation, except six patients, and medical records of these patients were reviewed for the clinical course and Glasgow outcome scale(GOS). Results : Overall management results of the 36 patients were good recovery in 13(36.1%), moderate disability in 12 (33.3%), severe disability in 1(2.8%), vegetative state in 1(2.8%) and 9(25.0%) of surgically treated patients had died. Conclusion : Although with limited number of patients, we conclude that urgent surgery for Hunt-Hess grade IV patients results in a better neurologic outcome and urgent surgery combined with aggressive postoperative management can minimize mortality.

  • PDF

Hoop Energy Storage System(HESS) for Electric Power Utility (전력 계통에의 이용을 위한 후프 에너지 저장 시스템)

  • 백광현;정기형
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1995.05a
    • /
    • pp.173-178
    • /
    • 1995
  • Hoop Energy Storage System(HESS) for electric power utility were discussed laying primary stress on the diurnal load leveling of Korean electric power system. A number of potential storage technologies are outlined and possibility for real application of HESS was suggested. Primary system variables were determined on the basis of state of electric power demand-supply of 1994. As a prerequisite technology for HESS, noncontacting support using magnetic pressure and high power conversion were discussed.

  • PDF

Performance Evaluation of Regenerative Braking System Based on a HESS in Extended Range BEV

  • Kiddee, Kunagone;Khan-Ngern, Werachet
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.5
    • /
    • pp.1965-1977
    • /
    • 2018
  • This paper proposed a regenerative braking system (RBS) strategy for battery electric vehicles (BEVs) with a hybrid energy storage system (HESS) driven by a brushless DC (BLDC) motor. In the regenerative braking mode of BEV, the BLDC motor works as a generator. Consequently, the DC-link voltage is boosted and regenerative braking energy is transferred to a battery and/or ultracapacitor (UC) using a suitable switching pattern of the three-phase inverter. The energy stored in the HESS through reverse current flow can be exploited to improve acceleration and maintain the batteries from frequent deep discharging during high power mode. In addition, the artificial neural network (ANN)-based RBS control mechanism was utilized to optimize the switching scheme of the vehicular breaking force distribution. Furthermore, constant torque braking can be regulated using a PI controller. Different simulation and experiments were implemented and carried out to verify the performance of the proposed RBS strategy. The UC/battery RBS also contributed to improved vehicle acceleration and extended range BEVs.

Development of an Advanced Hybrid Energy Storage System for Hybrid Electric Vehicles

  • Lee, Baek-Haeng;Shin, Dong-Hyun;Song, Hyun-Sik;Heo, Hoon;Kim, Hee-Jun
    • Journal of Power Electronics
    • /
    • v.9 no.1
    • /
    • pp.51-60
    • /
    • 2009
  • Hybrid Electric Vehicles (HEVs) utilize electric power as well as a mechanical engine for propulsion; therefore the performance of HEV s can be directly influenced by the characteristics of the Energy Storage System (ESS). The ESS for HEVs generally requires high power performance, long cycle life and reliability, as well as cost effectiveness. So the Hybrid Energy Storage System (HESS), which combines different kinds of storage devices, has been considered to fulfill both performance and cost requirements. To improve operating efficiency, cycle life, and cold cranking of the HESS, an advanced dynamic control regime with which pertinent storage devices in the HESS can be selectively operated based on their status was presented. Verification tests were performed to confirm the degree of improvement in energy efficiency. In this paper, an advanced HESS with improved an Battery Management System (BMS), which has optimal switching control function based on the estimated State of Charge (SOC), has been developed and verified.

Literature Review on Health Effect Surveys of Residents in Environmentally Contaminated Areas in South Korea from 1997 to 2021 (한국 환경오염 취약지역 주민 건강영향조사 문헌고찰(1997~2021))

  • Kyung-Hwa Choi;Sujung Kim;Hyun A Jang;Dahee Han;Ho-Jang Kwon;Yong Min Cho
    • Journal of Environmental Health Sciences
    • /
    • v.49 no.3
    • /
    • pp.134-148
    • /
    • 2023
  • Background: The conducting of health effect surveys (HESs) in environmentally contaminated vulnerable areas (ECVAs) by the central and local governments has been increasing apace with the increase in demand for HESs since the Environmental Health Act was enacted in South Korea in 2008. Objectives: This study aimed to review the HESs of residents in ECVAs conducted in South Korea. Methods: An analysis was performed on 125 reports obtained from the Environment Digital Library, PRISM, and local government websites after selecting from 803 projects obtained as ECVAs from the Korea ON-Line E-Procurement System (1997~2021), National Institute Environment Research (2000~2021), and Korea Environmental Industry and Technology Institute (2009~2021). The reports were classified by background (residents' demand, HES, and more), research design (cross-sectional study, cohort, ecological study, and panel), pollution source (abandoned metal mine (AMM), industrial complex (IC), and more), and assessment method of exposure and health effects. The survey area was converted into administrative district codes for geographical mapping. Results: There were 37, 34, 18, and 10 cases associated with AMM, IC, waste incinerators, and coal-fired power plants, respectively. Most of the studies conducted were cross-sectional studies and ecological studies. The proportion of epidemiological investigations by residents' demand showed an increase from 0.0% to 8.9% for the central government while decreasing from 16.7% to 14.3% for local governments after 2008 compared to before 2008. HESs increased at both the central and local government levels since 2014. For the evaluation method, 365 environmental hazards, 319 health outcomes, and 302 biological markers were investigated, with the most commonly investigated items being metals, cancer, and blood metals. Conclusions: HESs of residents in ECVAs in South Korea have been continuously developed both quantitatively and qualitatively. Future improvements are expected, and systematic review and classification of the HESs is warranted.

HESS(Hoop Energy Storage System)에서의 안정화 조건(stabilization condition) 과 공심코일실험을 통한 가능성 유효 출력의 계산

  • 오범환;조수범;김동일;이관철;정기형
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1996.10b
    • /
    • pp.13-17
    • /
    • 1996
  • 관성 에너지 저장 장치인 HESS (Hoop Energy Storage System)의 안정적인 운용을 위해 가장 중요한 자기 반발력하에서의 안정화 조건을 dipole approximation을 이용하여 계산하였다. 또한 고주파 입출력을 고려하여 공심코일을 이용한 자기유도 실험을 통하여 HESS에 있어서 가능한 출력을 예측하여 보았다.

  • PDF

Fermi Large Area Telescope Observations of the Dark Accelerator HESS J1745-303

  • Yeung, Paul
    • Journal of Astronomy and Space Sciences
    • /
    • v.33 no.4
    • /
    • pp.319-321
    • /
    • 2016
  • Reviewing the two MeV-GeV investigations in the field of the HESS J1745-303 performed using Fermi Large Area Telescope data, we confirmed that the emission peak comfortably coincides with 'Region A' in the TeV regime, which is the brightest part of this feature. The MeV-TeV spectrum can be precisely described by a single power-law. Also, recent investigation has shown that the MeV-GeV feature is elongated from 'Region A' toward the north-west, which is similar to the case of largescale atomic/molecular gas distribution.

Power Distribution Strategy for Wireless Tram with Hybrid Energy Storage System (하이브리드 에너지 저장장치를 탑재한 무가선 트램의 전력분배전략)

  • Kang, Kyung-Jin;Oh, Yong-Kuk;Lee, Jee-Ho;Yeom, Min-Kyu;Kwak, Jae-Ho;Lee, Hyeong-Cheol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.11
    • /
    • pp.1615-1621
    • /
    • 2014
  • A wireless tram which runs without catenary and instead uses batteries installed in the tram has been recently researched actively. This paper presents a new method maximizing absorption of regenerative energy of a wireless tram and extending life cycle of the energy storage device in the wireless tram by applying line-optimized charging and discharging scenario. Energy efficiency and life cycle of energy storage system (ESS) are highly dependent on the characteristic of operating conditions. For example, frequent charge and discharge with high power cause the problems that decrease the battery life cycles. Hybrid energy storage system (HESS) is combination of two ESSs which have complementary characteristics to each other. HESS can provide even better functionality and performance than the battery only ESS due to the synergy effect of two ESSs. This paper also provides a power distribution strategy and driving scenarios which increase the life cycle and energy efficiency of the HESS consisting of a battery and an ultra-capacitor. The developed strategy was tested and verified by a hardware-in-the-loop-simulation (HILS) system which emulates the a wireless tram.