• Title/Summary/Keyword: HEAT SINK

Search Result 561, Processing Time 0.028 seconds

Analysis of Natural Convection around Radial Heat Sink (원형 히트싱크의 자연대류 해석)

  • Yu, Seung-Hwan;Lee, Kwan-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1172-1176
    • /
    • 2009
  • In the present study, natural convection over a heat sink with a horizontal circular base and rectangular fins was numerically analyzed. To calculate natural convection heat transfer, the assumptions of ideal gas and laminar flow were made for air. Flow patterns around the heat sink were chimney-like. The resultant temperature distribution on the circular base appeared almost uniform. Parametric studies were performed to compare the effects of fin length, fin height, the ideal number of fins, and heat flux on the average temperature of a heat sink and the average heat transfer coefficient from the heat sink array. Correlation to predict the average Nusselt number was presented.

  • PDF

A Study on Heat Transfer Performances of a Heat Pipe Heat Sink for Power Control Semiconductors (전력제어 반도체용 히트파이프 냉각기의 열전달 성능 연구)

  • 강환국;김재진;김철주
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.8
    • /
    • pp.701-709
    • /
    • 2001
  • In this days, heat pipe heat sink has been widely applied to power controllers for railway substations to remove heat from power semiconductors(diodes or thyristors). The heat pipe heat sink consists of a aluminum heating block for mounting the thyristor, 2~3 heat pipes and large number of aluminum fins. The present study was to get fundamental informations of the structure, design parameters and heat transfer performances of heat pipe heat sink. Series of operational test for a unit with 3 heat pipes were performed and its heat flow circuit was analysed from the experimentally obtained data on wall temperature distribution. Total resistance was ranged 0.02~$0.03^{\circ}C$/W for a power range from 40W to400W. The time to get the steady state was approximately longer than 20 minutes, and overshooting was not occurred during start up operation.

  • PDF

Effects of Nozzle Size and Height of Aluminum Foam Heat Sink on Jet Impingement Heat Transfer (충돌제트 열전달에 발포알루미늄 방열기의 높이와 노즐의 크기가 미치는 영향)

  • Kim, Seo-Yeong;Baek, Jin-Uk;Gang, Byeong-Ha
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.9
    • /
    • pp.1263-1271
    • /
    • 2001
  • An experimental study is carried out for an aluminum foam heat sink attached to an isolated heat source to evaluate high potential of aluminum foam as a heat sink with impinging jets. The effects of the pore density and the height of the aluminum foam heat sink, the jet Reynolds number, and the nozzle diameter are delineated in comparison with a conventional pin type heat sink. It is found that the aluminum foam with small pores is inefficient for the heat transfer enhancement due to the large flow friction at the given porosity. In the parameter ranges of the present study, the change in the nozzle diameter shows no significant effects on the surface temperature of the aluminum foam heat sink at a given Reynolds number. The heat transfer enhancement is strongly dependent on the jet Reynolds number and shows a maximum value at a moderate Reynolds number.

Shape Optimization of Heat Sink for Power Amplifier by Heat Transfer Analysis (열전달 해석에 의한 파워 증폭기 방열기의 형상 최적화)

  • Lee, Dong-Ryul
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.3
    • /
    • pp.1-6
    • /
    • 2011
  • In order to find better performance of heat sink, in this research, different cases were analysed by changing number of slots and shape of fins. Round shape fins which have wide surface showed 24% better heat transfer rate than vertical fins. There were not big discrepancies between 1 slot and 2 slots fins. Consequently, for better performance of heat sink, developments for widening surface and better material for high heat transfer rate are needed.

Optimization of Al 6063 Heat Sink using CFD Simulation and Comparative Analysis of Thermal Dissipation Properties with Thermal Conductive Polycarbonate (CFD전산모사를 이용한 Al 6063 Heat Sink 최적화 설계와 열전도성 Polycarbonate와의 방열성능 비교 분석)

  • Her, In-Sung;Lee, Se-Il;Lee, A-Ram;Yu, Young Moon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.7
    • /
    • pp.19-25
    • /
    • 2014
  • In the LED lighting applications, because LED packages are the origin of heat generation, there are thermal design problem on heat sinks. In the thermal design, it is important to consider the total volume and the total weight of heat sink simultaneously. In this study, an Al 6063 heat sink was optimized using Computational Fluid Dynamics(CFD) simulation tool for the cooling of 30W LED module, and then the cooling performance and the total weight of heat sinks with Al 6063 and Thermal Conductive Polycarbonate(TCP) were compared under the same conditions. As the result of simulation, an Al 6063 heat sink was optimized with 22 ea. of fins and 1.6 mm of fin thickness. LED Junction Temperature of the TCP Heat Sink was $5.6^{\circ}C$ higher, but total weight of it was 47 % less than the Al 6063.

A Study on Cooling Performance of Aluminium Heat Sink with Pulsating Heat Pipe (PHP를 결합한 알루미늄 히트싱크의 냉각성능에 관한 연구)

  • Kim, Jong-Soo;Ha, Soo-Jung;Kwon, Yong-Ha
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.8
    • /
    • pp.1016-1021
    • /
    • 2011
  • The enhancement for cooling performance of heat sink is surely necessary to guarantee the performance of electronic products. So in this paper, the cooling performances of the aluminum heat sink with pulsating heat pipe(PHP) were investigated experimentally and numerically. The pulsating heat pipe was used as a heat spreader. Working fluid of PHP was R-22. Heat inputs were 30W, 60W, 80W and 100W, respectively. Heat sink was tested for forced convection conditions with air velocity of 1 ~ 4m/s. And CFD simulations were conducted for two different heat sinks. The results showed that the cooling performance of heat sink with pulsating heat pipe was higher than that of conventional heat sink. Therefore, the pulsating heat pipe can be a good tool to improve cooling performance of heat sink.

Evaluation of Heat Release Performance of Swaged- and Extruded-type Heat Sink Used in Industrial Inverter (산업용 인버터에 사용되는 압입식 및 압출식 히트싱크의 방열 성능 평가)

  • Kim, Jung Hyun;Ku, Min Ye;Lee, Gyo Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.2
    • /
    • pp.523-528
    • /
    • 2013
  • In this experiment, we investigated the performance of two types of heat sink, swaged- and extruded-type, used in the inverter of industrial electricity generator. The swaged-type heat sink has 62 fins, and the extruded-type has 38 fins having the same dimension as that of the swaged-type. But the extruded-type heat sink maintains the same heat transfer area by the laterally waved surface which has 1 mm in radius. As a result, the swaged- and extruded-type heat sinks released 70.7% and 63.8% of the heat incoming to the heat sink, respectively. The other incoming heat were naturally convected and radiated to the ambient. In spite of 40% decrease in number of fins, the heat release performance of the extruded-type heat sink was lowered only 6.9% than that of the swaged-type. We believe that, this shows the increment of effective heat transfer area by the laterally waved surface of fins and the better heat transfer property of the extruded-type heat sink.

Heat Sink Design Optimization using Genetic Algorithm (Genetic Algorithm을 활용한 Heat Sink 최적 설계)

  • Kim, Won Gon
    • Proceeding of EDISON Challenge
    • /
    • 2015.03a
    • /
    • pp.500-509
    • /
    • 2015
  • This paper presents the single objective design optimization of plate-fin heat sink equipped with fan cooling system using Genetic Algorithm. The proper heat sink and fan model are selected based on the previous studies. And the thermal resistance of heat sinks and fan efficiency during operation are calculated according to specific design parameters. The objective function is combination of thermal resistance and fan efficiency which have been taken to measure the performance of the heat sink. And Decision making procedure is suggested considering life time of semiconductor and Fan Operating cost. And also Analytical Model used for optimization is validated by Fluent, Ansys 13.0 and this model give a quite reasonable and reliable design.

  • PDF

Investigation of the Optimal Cooling Performance Using Peltier Module and Heat Sink (펠티에 소자 및 히트싱크를 이용한 최적 냉각성능에 관한 연구)

  • Lee, Dong-Ryul
    • Journal of Power System Engineering
    • /
    • v.10 no.4
    • /
    • pp.65-70
    • /
    • 2006
  • This study is to experimentally evaluate the cooling performance of the Bonding type and Injection type of heat sink using three different kinds of industrial Peltier module by digital LabViewTM measurement. Injection type of heat sink could be more efficient for the heat transfer than Bonding type, even with 30% more radiating surface area. In addition, the experimental results revealed that the sufficient power supplied was able to show the better cooling performance of Peltier module. In order to verify the optimal cooling performance of the cooling device, two Peltier module, HMN 6040 and HMN 1550 with Bonding and Injection type of heat sink were used. The cooling performance with injection type of heat sink was 2.11% and 6.24% better than that with bonding type of heat sink under the HMN 6040 and HMN 1550, respectively.

  • PDF

A NUMERICAL SIMULATION FOR THE PERFORMANCE CHARACTERIZATION OF HEAT SINKS (Heat Sink의 특성확인을 위한 수치적 Simulation)

  • Kim, Chang Nyung;Moon, Sung-il
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.3 no.2
    • /
    • pp.147-156
    • /
    • 1999
  • A numerical simulation has been carried out for the performance characterization of heat sinks in electronic equipment. Heat transfer characteristics have been analyzed for various design parameters including the shape of heat sink, thickness of fin base and fin pitches. A commercial program called Flotherm has been employed for the numerical calculation. Optimal design of the heat sink has been persued which is closely related with the reduction of heat resistance involved in conduction and convection of heat.

  • PDF