• 제목/요약/키워드: HDPE pipes

검색결과 23건 처리시간 0.021초

근해역 양광시험을 위한 HDPE Pipe의 구조특성 연구 (Analysis of Structural Characteristics of HDPE Pipe for Manganese Lifting Test)

  • 이재환;윤치호
    • 한국해양공학회지
    • /
    • 제25권6호
    • /
    • pp.86-90
    • /
    • 2011
  • The mining of imitated manganese noodles in 1000 m of seawater is planned for 2012. Thus, it is necessary to prepare the lifting pipes to be used for the test. Because of storage and expense constraints, flexible and economic HDPE pipe is being considered, making it necessary to test the structural safety. Material, pressure-chamber tests and finite element analysis of HDPE pipe for the 1000-m depth were performed. The tangential stiffness of HDPE was obtained through tension and three-point bending material tests and used for a structural analysis. FEA results show that the current sample pipe segment is safe for 1000 m of water pressure, and the stress result is also within the safe value. From the current results, the HDPE pipe seems to be acceptable only for the currently suggested constraints. However, more numerical and pressure tests need to be considered by applying additional physical conditions such as gravitational and hydrodynamic loads, external and internal fluid pressure, axial force induced ship motion, and heavy pump pressure to determine future usage.

수치해석을 통한 수직 밀폐형 지중열 교환기의 열전달 거동 연구 (Thermal Behavior of Vertical Ground Heat Exchanger by Numerical Simulation)

  • 길후정;이철호;김주영;최항석
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.1638-1646
    • /
    • 2008
  • This paper presents a series of numerical simulations on the thermal performance and sectional efficiency of a closed-loop vertical ground heat exchanger (U-loop) equipped in a geothermal heat pump system (GHP). A 2-D finite element analysis, ANSYS, was employed to evaluate the temperature distribution on the borehole cross section involving HDPE pipe/grout/soil formation to compare the sectional efficiency between the conventional U-loop and a new latticed HDPE pipe system which is equipped with a thermally insulating latice in order to reduce thermal interference between the inflow and outflow pipes. In addition, a 3-D finite volume analysis (Fluent) was used to simulate the operating process of the closed-loop vertical ground heat exchanger by considering the effect of grout's thermal properties, rate of circulation pump, distance between the inflow and outflow pipes, and the effectiveness of the latticed HDPE pipe system. It was observed that the thermal interference between the two strands of U-loop is of importance in determining the efficiency of the ground heat exchanger, and thus it is highly recommendable to modify the cross section configuration of the conventional U-loop system by including a thermally insulating latice between the two strands.

  • PDF

파이프 순환수의 수치해석 모사를 통한 수직 밀폐형 지중열교환기 단면의 열전달 효율 평가 (Numerical Evaluation of Heat Transfer un Ground Heat Exchanger Considering Flow through U-loop)

  • 길후정;이강자;이철호;최항석
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.583-587
    • /
    • 2009
  • This paper presents a series of numerical simulations on the thermal performance and sectional efficiency of a closed-loop vertical ground heat exchanger (U-loop) equipped in a geothermal heat pump system (GHP). A 3-D finite volume analysis (Fluent) was used to simulate the operating process of the closed-loop vertical ground heat exchanger by considering the effect of the thickness of HDPE pipe and grout thermal properties, distance between the inflow and outflow pipes, and the effectiveness of the latticed HDPE pipe system. It was observed that the thermal interference between the two strands of U-loop is of importance in determining the efficiency of the ground heat exchanger, and thus it is highly recommendable to modify the cross section configuration of the conventional U-loop system by including a thermally insulating latice between the two strands.

  • PDF

유한요소 시뮬레이션을 통한 지역난방열배관 특성 평가 및 강화이형관의 제안 (Design Validation and Improvement of District Heating Pipe Using FE Simulation)

  • 김주용;김호범;고현일;안영모;조종두
    • 대한기계학회논문집A
    • /
    • 제33권4호
    • /
    • pp.337-345
    • /
    • 2009
  • This paper investigates the reliability of district heating pipes at thermo-elastic fatigue loading. District heating pipes, subjected to $120^{\circ}C$ and $16kg_f/cm^2$ due to water distributing service through inside the pipes, should endure long term cyclic thermal-mechanical loadings. The heating pipes are the co-centric tubes of steel pipe, poly urethane(PUR) insulator, and high density poly ethylene(HDPE) case. On installation, foam pad is externally wrapped for accommodating stress reduction near the bend sections of pipes. However, there have been frequent reports on the failures of bend sections in the middle of long term service. This study scrutinizes the observed failures near the bend sections through applying the finite element methods. Specially in this study, heating pipes are studied on the influence of foam padding on failures and proposed new designs for reinforced bend without foam pad.

파이프 재질 및 형태에 따른 에너지 슬래브의 현장 열교환 성능 평가 (Evaluation on in-situ Heat Exchange Efficiency of Energy Slab According to Pipe Materials and Configurations)

  • 이석재;오광근;한신인;박상우;최항석
    • 한국지열·수열에너지학회논문집
    • /
    • 제13권4호
    • /
    • pp.1-7
    • /
    • 2017
  • The energy slab is a ground coupled heat exchanger equipped in building slab structures, which represents a layout similar to the horizontal ground heat exchanger (GHEX). The energy slab is installed as one component of the floor slab layers in order to utilize the underground structure as a hybrid energy structure. However, as the energy slab is horizontally arranged, its thermal performance is inevitably less than the conventional vertical GHEXs. Therefore, stainless steel (STS) pipes are alternatively considered as a heat exchanger instead of high density polyethylene (HDPE) pipes in order to enhance thermal performance of GHEXs. Moreover, not only a floor slab but also a wall slab can be utilized as a heat-exchangeable energy slab in order to maximize the use of underground space effectively. In this paper, four field-scale energy slabs were constructed in a test bed, which consist of the STS and HDPE pipe, and a series of thermal response tests (TRTs) was conducted to evaluate relative heat exchange efficiency per unit pipe length according to the pipe material and the configuration of energy slabs. The energy slab equipped with the STS pipe shows higher thermal performance than the energy slab with the HDPE pipe. In addition, thermal performance of the wall-type energy slab is almost equivalent to the floor-type energy slab.

해상 부유식 1MW 해수온도차발전 시스템의 라이저 설계 (Design of Riser in 1MW OTEC system mounted on Floating Barge)

  • 권용주;정동호;김현주
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제18권1호
    • /
    • pp.22-28
    • /
    • 2015
  • 1 MW 해수온도차발전 시스템의 라이저에 관한 설계를 수행한다. 라이저의 직경은 1 MW 발전을 위한 심층수 취수량에 기초하여 결정되고, 관종은 제작 가능한 상업용 파이프를 대상으로 종류별 특성을 분석한 후 선정한다. 강관, GFRP관, 그리고 HDPE관 중 HDPE관을 선정하며, 선정된 관종의 중량과 강도를 보강하기 위하여 설계를 수행한다. HDPE 라이저 하부 끝단에 중량체를 설치하여 중량을 보강하며, HDPE 라이저 축방향으로 와이어로프를 설치하여 강도를 보강한다. 중량체의 중량은 GFRP관 무게 대비 25%와 50%가 되도록 설계되며, 라이저 끝단에 연결되는 중량체의 모든 하중은 와이어로프가 지지하도록 설계된다. 설계된 HDPE라이저는 연중 온도차발전이 가능한 하와이 인근 해역에 설치되는 것으로 가정하여, 수치해석적 방법에 의한 안전성 평가를 수행한다. 안전성이 검증된 HDPE 라이저에 대하여 경제적으로 가장 유리한 HDPE 라이저의 최종 제원을 결정한다. 설계된 라이저는 향후 1MW 해수온도차발전 시스템 실증을 위한 설계 자료로 활용될 수 있을 것으로 기대된다.

이중관형 지중열교환기 구성에 따른 현장 열성능 평가 (Evaluation on in-situ Thermal Performance of Coaxial-type Ground Heat Exchanger with Different Configurations)

  • 이석재;정현석;오광근;박상우;최항석
    • 한국지열·수열에너지학회논문집
    • /
    • 제15권4호
    • /
    • pp.8-15
    • /
    • 2019
  • In order to design coaxial-type Ground Heat Exchangers (GHEXs) efficiently, the effect of components (i.e, heat exchange pipe and grouting material) on the thermal performance of coaxial-type GHEXs should be identified in advance. In this paper, three coaxial-type GHEXs with different configurations were constructed in a test bed. Then, the effect of heat exchange pipes and grouting materials on the thermal performance of coaxial-type GHEXs was investigated by performing in-situ thermal response tests (TRTs) and thermal performance tests (TPTs). In the TRTs, the effective thermal conductivities of the coaxial-type GHEXs with concrete grouting and STS pipes were improved by 6.15 and 22.7%, respectively compared to those of bentonite grouting and HDPE pipes. Additionally, in the TPTs, the use of concrete grouting and STS pipes in the coaxial-type GHEXs enhanced the in-situ thermal performance by 15 and 33.8%, respectively.

지열냉난방시스템 수직형 지중열교환기 그라우트의 열적 특성에 관한 연구 (A Study on Thermal Conductivity Properties of Ground Heat Exchangers for GSHP systems)

  • 백성권;전중규;안형준
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.429-433
    • /
    • 2007
  • Cement mortar and concrete can be used as grouts but problems regarding shrinkage and the discord of coefficients of thermal expansion between grouts and HDPE pipes has to be solved. Thermal conductivities of wet condition two times larger than those of dry condition, except for pure cement mortar. The addition of sand into the cement grouts greatly increases the thermal conductivity. The addition of bentonite into the cement grouts reduces thermal conductivity thus reducing the density. Bentonite grouting must be used only below the groundwater table since bentonite grouts possesses high shrinkage property in dry condition. The addition of sand prevents the shrinkage of bentonite grouts. Bentonite manufactured in Korea can be used since they possess similar thermal conductivities with imported products. The addition of sand into the bentonite grouts greatly increases the thermal conductivity.

  • PDF

해수 담수화 설비의 취수 및 배출수 해저 배관 최적화 설계 (Optimal Design of Submarine Pipeline for Intake and Discharge of Seawater Desalination Facilities)

  • 최광민;한인섭
    • 상하수도학회지
    • /
    • 제31권6호
    • /
    • pp.599-609
    • /
    • 2017
  • Desalination plants have been recently constructed in many parts of the world due to water scarcity caused by population growth, industrialization and climate change. Most seawater desalination plants are designed with a submarine pipeline for intake and discharge. Submarine pipelines are installed directly on the bottom of the water body if the bottom is sandy and flat. Intake is located on a low-energy shoreline with minimal exposure to beach erosion, heavy storms, typhoons, tsunamis, or strong underwater currents. Typically, HDPE (High Density Polyethylene) pipes are used in such a configuration. Submarine pipelines cause many problems when they are not properly designed; HDPE pipelines can be floated or exposed to strong currents and wind or tidal action. This study examines the optimal design method for the trench depth of pipeline, analysis of on-bottom stability and dilution of the concentrate based on the desalination plant conducted at the Pacific coast of Peru, Chilca. As a result of this study, the submarine pipeline should be trenched at least below 1.8 m. The same direction of pipeline with the main wind is a key factor to achieve economic stability. The concentrate should be discharged as much as high position to yield high dilution rate.

수직 밀폐형 지중열교환기 뒤채움재로서 시멘트 그라우트의 적용성 검토 (Study on Cement-based Grout for Closed-loop Vertical Grout Heat Exchanger)

  • 박문서;위지혜;이철호;최항석;강신형
    • 한국지반공학회논문집
    • /
    • 제26권7호
    • /
    • pp.107-115
    • /
    • 2010
  • 본 연구에서는 수직 밀폐형 지중열교환기 뒤채움 용도로, 기존 벤토나이트 그라우트의 대안으로서 시멘트 그라우트의 적용성을 검토하였다. 실내 시험을 통하여 물/시멘트 비, 천연규사 첨가비 흑연 첨가비의 변화에 따른 시멘트 그라우트 열전도도 및 유동성에 미치는 영향을 평가하였으며 배합비에 따른 시멘트 그라우트의 일축압축강도를 측정하였다. 실제 지중열교환기용 파이프내 순환유체의 온도변화가 시멘트 그라우트의 재료적 안정성에 미치는 영 향을 검토하기위해 $-5^{\circ}C$$50^{\circ}C$를 한 주기로 하여 일축압축강도를 반복적으로 측정하였다. 또한, 시멘트 그라우트가 지중에서 양생된 후, 냉난방 운전에 따른 순환수의 계절적 변화에 의한 시멘트 그라우트와 순환파이프의 접촉면의 양호한 부착성 유지 여부를 판단하기 위해 시멘트 그라우트에 HDPE 파이프를 삽입한 시료의 등가투수계수를 flexible wall penneameter) 이용하여 장기간 측정하였다.