• 제목/요약/키워드: HCl solution

검색결과 705건 처리시간 0.027초

양자점 감응 태양전지의 Cu2S 상대 전극 제작조건 최적화 (Optimization of Fabrication Conditions for Cu2S Counter Electrodes of Quantum Dot-Sensitized Solar Cells)

  • 정성목;하승범;서주원;김재엽
    • 한국수소및신에너지학회논문집
    • /
    • 제32권6호
    • /
    • pp.663-668
    • /
    • 2021
  • For the development of highly efficient quantum dot-sensitized solar cells (QDSCs), it is important to enhance the electrocatalytic activity of the counter electrodes (CEs). Herein, a fabrication process of Cu2S CEs are optimized for the development highly efficient QDSCs. The surface of brass film is treated with HCl solution to prepare the Cu2S CEs, and the concentraion as well as the temperature of HCl solution are controlled. It is found that the uniformity for the thickness of prepared Cu2S CEs is enhanced when the diluted HCl solution is used, compared to the HCl solution of standard concentration. In addition, the electrocatalytic activity of the Cu2S CEs is also increased with the modificed process, which is confirmed by impedance data and Tafel polarization curves. As a result, the photoconversion efficiency of QDSCs is improved from 4.49% up to 5.73%, when the concentraion and temperature of the HCl treatment are efficiently optimized.

Ionic Equilibria and Ion Exchange of Molybdenum(VI) from Strong Acid Solution

  • Lee, Man-Seung;Sohn, Seong-Ho;Lee, Myung-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권10호
    • /
    • pp.3687-3691
    • /
    • 2011
  • Ion exchange experiments of molybdenum(VI) from strong HCl and $H_2SO_4$ solution have been done to investigate the existence of anionic complexes. The concentration of HCl and $H_2SO_4$was changed from 1 to 9 M. From the data on the complex formation of molybdenum in aqueous solution, a new distribution diagram of Mo(VI) was constructed in the pH range from zero to 10. AG 1 X-8, an anion exchange resin, and Diphonix, a cation exchange resin were used in the loading experiments. Ion exchange results indicate that anionic complexes of Mo(VI) begins to form from 3 M HCl and 1 M $H_2SO_4$ solution and the tendency to form anionic complexes is stronger in HCl than in $H_2SO_4$ solution. Our results can be utilized in the analysis of Mo(VI) in strong acid solution and in the design of a process to separate Mo(VI).

Comprehensive Analysis of the Corrosion Inhibition Performance of 4-Piperonylideneaminoantipyrine for Mild Steel in HCl Solution: Concentration, Time, Temperature Effects, and Mechanistic Insights

  • Ahmed Y. I. Rubaye;Sabah M. Beden;Ahmed A. Alamiery;A. A. H. Kadhum;Waleed K. Al-Azzawi
    • Corrosion Science and Technology
    • /
    • 제23권1호
    • /
    • pp.20-32
    • /
    • 2024
  • Metal corrosion in acidic environments is a major issue in various industrial applications. This study evaluates the 4-piperonylideneaminoantipyrine (PPDAA) corrosion inhibition efficiency for mild steel in a hydrochloric acid (HCl) solution. The weight loss method was used to determine the corrosion inhibition efficiency at different concentrations and immersion time periods. Results revealed that the highest inhibition efficiency (94.3%) was achieved at 5 mM concentration after 5 hours of immersion time. To inspect the surface morphology of the inhibitor film on the mild steel surface, scanning electron microscopy (SEM) was used before and after immersion in 1.0 M HCl. Density functional theory (DFT) calculations were performed to investigate the molecular structure and electronic properties of the inhibitor molecule to understand the corrosion inhibition mechanism. Theoretical results showed that the inhibitor molecule can adsorb onto the mild steel surface through its nitrogen and oxygen atoms, forming a protective layer that prevents HCl corrosive attack. These findings highlight the potential of PPDAA as an effective corrosion inhibitor for mild steel in HCl solution. Moreover, combining experimental and theoretical approaches provides insights into the mechanism of corrosion inhibition, which is essential for developing effective strategies to prevent metal corrosion in acidic environments.

토양세척용매의 종류 및 농도에 따른 폐금속광산 폐기물내 중금속의 추출특성 (Evaluation on Extractability of Heavy Metals in Mine Tailings of Disused Metal Mines with Concentrations and Kinds of Soil Washing Solutions)

  • 김정대;남궁완
    • 대한환경공학회지
    • /
    • 제27권8호
    • /
    • pp.787-798
    • /
    • 2005
  • 본 연구에서는 폐광산지역에서 발생되는 폐기물인 광미를 대상으로 토양세척공정을 이용하여 다양한 세척용매와 농도, 그리고 추출시간에 따른 중금속의 추출특성을 파악하였다. 세척용매로는 물, HCl(0.1, 0.3, 1.0 N), EDTA(0.01, 0.05, 0.1 M), SDS(0.1, 0.5, 1.0%)를 이용하였다. 그 결과, 물과 SDS 용매에서 Zn과 Cd이 Pb과 Cu보다 높은 추출효율을 보였지만, 전체적으로는 1%이하로 중금속의 추출에 효과적이지 못하였다. 그러나, SDS에서 Pb과 Cu의 추출효율은 추출시간이 길어질수록 증가하였다. HCl과 EDTA를 이용한 중금속의 추출은 물과 SDS보다 빠른 추출경향을 보였고, 대부분의 중금속이 6시간 이내에 추출되었으며 용매의 농도와 무관하였다. 6시간 이후에는 느린 추출경향을 보였지만 세척용매의 농도에 따라 좌우되었다. 또한, 용매의 농도가 증가할수록 추출경향은 빨라졌고, 추출 효율도 증가하였다. 추출효율은 1.0 N HCl에서 Cd>Pb>Zn>Cu로, 0.1M EDTA에서 Pb>Cd>Zn>Cu 순으로 높았다. 농도증가에 따른 추출효과는 HCl에서 Pb이, EDTA에서 Pb과 Cd이 가장 컸으며, 중금속제거를 위한 6시간이상의 추출은 비효과적이었다.

Estimation of Interaction Parameter of FeCl+ from Hydrochloric Acid Solution by Solvent Extraction with Amine

  • Lee, Man-Seung;Nam, Sang-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권9호
    • /
    • pp.3429-3432
    • /
    • 2011
  • Distribution diagram of $FeCl_2$ in HCl solution indicated that $FeCl^+$ was a predominant species in strong HCl solution up to 10 M. Solvent extraction of $FeCl_2$ has been performed in the HCl concentration range from 5 to 9 M by using Alamine336 as an extractant. Interaction parameter of $FeCl^+$ for Bromley equation was estimated from our solvent extraction data. This parameter thus obtained in our study can be employed in calculating the activity coefficient of $FeCl^+$ in high concentration of HCl.

전이방사선을 이용한 의료제품 멸균연구 II (Radiosterilization of Medical Products(II))

  • 이강순;천기정;김기수
    • 미생물학회지
    • /
    • 제13권2호
    • /
    • pp.64-70
    • /
    • 1975
  • As a serial experiment of radiosterilization of medical products, we investigated the feasibility of using gamma ray to sterilize antibiotics, tetracycline HCl. Tetracycline HCl in aqueous solution and dried state irradiated with several dose levels was assayed for physico-chemical properties by checking UV absorption spectra, paper chromatogrph. IR spectra and NMR sepctra, and antibiotic activities by [means of agar plaque technique and tube $d_1$]ution method. In physico-chemical propertis and biological activities, the teracycline HCl in dried state remained radioresistant up to exposure of 10 Mrad, however, in aqueous solution, the dose of 300 Krad produced a significant inactivation. From the results of this study, radiosterilization of tetracycline HCl is more recommendable in the dried state than in aqueous solution.

  • PDF

알루미늄 전해 콘덴서용 양극박 전해 에칭 (Electorchemical Etching of Anode Foil for Aluminum electorlytic Capacitors)

  • 이중선;유연철
    • 한국표면공학회지
    • /
    • 제26권5호
    • /
    • pp.271-279
    • /
    • 1993
  • Experiments on electorchemical etching of aluminum foils with high cubic textures were carried out in this study. Etching behaviours and pit shapes with respect to various conditions of eletrochemical etching were in-vestigated. When HCl and NaCl solutions were used as electrolytes, the highest capacitanes were observed in solutions of 1MHCl and 5M NaCl. It was foundd that capacitance was improved by addition of H2SO4 to HCl so-lution which is considered to be due to the suppression of oxide film formation on the aluminum surface. The homogeneous distribution of each pits obtained in the HCl solution, while the degree of weight loss was lowest in the Nacl solution. The best etching properties in 1M HCl solution were obtained at the etching condi-tions of 0.15 A/$\textrm{cm}^2$, 150sec and$ 90^{\circ}C$.

  • PDF

TMOS 용액을 이용한 실리카 유리의 제조 (Preparation of Silica Glass using TMOS Solution)

  • 서정민;신대용;한상목
    • 한국세라믹학회지
    • /
    • 제28권4호
    • /
    • pp.324-328
    • /
    • 1991
  • Monolithic silica gel and glass were prepared from TMOS solution with high concentration of HCl. Appearance of the dried gels and gelation time varied with content of HCl and H2O were observed in the TMOS-CH3OH-HCl-H2O system. The conversion from gel to glass during heat treatment stage was investigated using TG-DTA, XRD, IR and SEM and characteristics of the gel were examined by measuring bulk density, linear shrinkage and Vicker's hardness. A transparent silica glass was prepared from the gel after heat treatment at 1050℃.

  • PDF

염산테트라싸이클린의 적용시간에 따른 임플란트 표면변화에 관한 주사전자현미경적 연구 (Scanning Electron Microscopic Study of the Effect of Tetracycline-HCl on the Change of Implant Surface Microstructure according to Application Time)

  • 김우영;이만섭;박준봉;허익
    • Journal of Periodontal and Implant Science
    • /
    • 제32권3호
    • /
    • pp.523-537
    • /
    • 2002
  • The present study was performed to evaluate the effect of tetracycline - HCl on the change of implant surface microstructure according to application time. Implants with pure titanium machined surface, SLA surface and $TiO_2blasted$ surface were used. Implant surface was rubbed with 5Omg/ml tetracycline - HCl solution for ${\frac}{1}{2}$ min., 1 min., $1{\frac}{1}{2}$ min., 2 min., and 3min. respectively in the test group and with no conditioning in the control group. Then, the specimens were processed for scanning electron microscopic observation. The following results were obtained. 1. In the pure titanium machined surfaces, the control specimen showed a more or less rough machined surface composed of alternating positive and negative lines corresponding to grooves and ridges. After treatment, machining line was more pronounced for the control specimens. but in general, test specimens were similar to control. 2. In the SLA surfaces, the control specimen showed that the macro roughness was achieved by large-grit sandblasting. subsequently, the acid-etching process crated the micro roughness, which thus was superimposed on the macro roughness. 3. In the SLA surfaces, irrespective of the application time of 50mg/ml tetracycline-HCl solution, in general, test specimens were similar to control. 4. In the $TiO_2blasted$ surfaces the control specimen showed the rough surface with small pits. The irregularity of the $TiO_2blasted$ surfaces with 50mg/ml tetracycline-HCl solution was lessened and the flattened areas were wider relative to the application time of tetracycline - HCl solution. In conclusion, pure titanium machined surfaces and SLA surfaces weren't changed irrespective of the application time of tetracycline-HCl solution. And the $TiO_2blasted$ surfaces conditioned with tetracycline - HCl solution began to be changed from $1{\frac}{1}{2}$ min. This results are expected to be applied to the regenerative procedures for peri-implantitis treatment.

Extraction of La(III) by a nonionic microemulsion containing D2EHPA in hollow fiber contactor

  • Ou, Huilin;Gong, Fuzhong;Tang, Yanxia;Luo, Yan;Liu, Liheng
    • Membrane and Water Treatment
    • /
    • 제12권2호
    • /
    • pp.75-82
    • /
    • 2021
  • This study aimed to prepare a W/O nonionic microemulsion system(MEs) consisting of OP-4[polyoxyethylene(4) nonylphenol], OP-7[polyoxyethylene(7) nonylphenol], 1-hexanol, D2EHPA, kerosene and HCl solution and applied to the extraction of La(III) from chloride aqueous solution within the polysulfone hollow fiber contactor (HFC),laboratory-scale experiments were carried out to investigate the recovery of La(III) using as-prepared microemulsion from the simulation wastewater containing La(III),Al(III) and Fe(III). The right weight ratio(Rs) of OP-4 to OP-7 was firstly confirmed through determination of the solubilization capacity of HCl solution(W0,HCl) in microemulsion, the effect of several factors such as the HCl concentration, temperature and effective extraction time on the extraction efficiency of La(III) was discussed. Results showed that the acceptable Rs was 4:6 to prepare the W/O MEs. The extraction yield of La(III) increased with the increasing of HCl concentration, temperature and effective extraction time and reaches to 97.3% while using five-stage modules. The recovery yield of La(III) from simulation La-bearing wastewater was 90.6%.