• Title/Summary/Keyword: HCHO

Search Result 236, Processing Time 0.025 seconds

Characteristics of pollutant emission from wallpapers - Around TVOC and HCHO - (벽지에서 발생되는 오염물질 방출특성 - TVOC와 HCHO를 중심으로 -)

  • Jang, Seong-Ki;Kim, Mi-Hyun;Lee, Hong-Suk;Lim, Jun-Ho;Jang, Mee;Seo, Soo-Yun
    • Analytical Science and Technology
    • /
    • v.18 no.6
    • /
    • pp.542-551
    • /
    • 2005
  • This study is to investigate the characteristics of emission concentration according to wallpaper sort and emission time using small chamber method. The target compounds included 45 VOCs and formaldehyde, which were respectively determined by adsorption sampling and thermal desorption coupled with GC/MS method, and by sampling in DNPH cartridge and HPLC method. The emission factor of TVOC and HCHO was detected to $1.1mg/m^2{\cdot}h$ and $0.01mg/m^2{\cdot}h$ respectively, and the wallpapers of 25 satisfied emission standard. TVOC emission factor appeared in order of the concentration of PVC, natural, and Non-PVC wallpaper, while HCHO was detected very low concentration without relation to wallpaper sort. The paraffin hydrocarbons appeared to be the most contributable class of hydrocarbons in terms of their concentrations, followed by aromatics, and olefins, halogenated hydrocarbons was not detected. PVC wallpapers plentifully emitted TVOC above other wallpapers, and toluene was showed higher concentration of 10 times than natural wallpaper. In addition to, emission factor according to elapse was gradually decreased.

Studies on the Emission control of methanol engine exhaust with modified 3-way catalyst at cold start condition (변형된 삼원촉매에 의한 저온시동조건에서의 메탄올엔진 배가스 정화효과에 관한 연구)

  • 홍종성;정석진
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.9 no.2
    • /
    • pp.160-167
    • /
    • 1993
  • As the major methanol fueled vehicle exhaust components, formaldehyde & methanol conversion over the existing commercial 3-way catalyst was examined in a labolatory tains different Ag loadings on commercial 3-way catalyst, and german commercial catalysts for methanol engine exhaust manufactured by a commercial manufacturer. Silver catalysts were prepared by the wet impregnation of silver nitrate solution on commercial 3-way catalyst. These catalysts were characterized with BET Surface area and pore size distribution. In general, the formaldehyde(HCHO) conversion of the tested catalysts was similar to that of methanol$(CH_3OH)$. At 100$^\circ$C, which is equivalent to the cold start condition, 5wt% Ag cat. showed the most excellent HCHO and $CH_3OH$ conversion. The order of activity for conversion of HCHO & $CH_3OH$ to carbon dioxide and water vapor was as follows ; 5wt% Ag/3-way cat.>2wt% Ag/3-way cat.>german cat. front(1) > german cat. rear(2) > 10wt% Ag/3-way cat.> commercial 3-wat catalyst. However there was no significant activity difference between those tested catalysts in the hot run condition of 400$^\circ$C. Therefore, it could be concluded that the Ag-modified 3-way catalyst was the most effective and practical catalyst system which could be capable of removal the HCHO and methanol at the special condition of low temperature such as cold start condition.

  • PDF

Characterization and Assessment of Indoor Air Quality in Newly Constructed Apartments -Volatile Organic Compounds and Formaldehyde- (신축공동주택의 실내공기질 특성 및 평가 -휘발성 유기화합물 및 포름알데히드 중심으로-)

  • Sim, Sang-Hyo;Kim, Yoon-Shin
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.4 s.91
    • /
    • pp.275-281
    • /
    • 2006
  • Indoor air quality is the dominant contributor to total personal exposure because most people spend a majority of their time indoors. Especially exposure to indoor air can potentially pose a greater threat than exposure to ambient air when indoor environments have sources of contaminants. In this study, volatile organic compounds (VOCs) and formaldehyde (HCHO) within newly constructed apartment have been determined in 27 houses of apartment in Seoul from December 2004 to March 2005. The measured indoor air pollutants were HCHO, volatile organic compounds including benzene, toluene, styrene, xylene, ethylbenzene and sampled on the standard method of Ministry of Environment in Korea. The indoor levels for benzene, xylene, toluene, ethylbenzene, styrene, and HCHO have significant increase trend after 5 hours closing of windows and doors. Levels of measured air pollutants concentrations between living rooms and bedrooms have not shown significant difference. Spearman correlation coefficient among the measured air pollutants ranged from 0.303 to 0.946, indicating similar source in building materials.

The Actual State of TVOC and the Responses of Sick House Syndrome in Newly Built University Dormitory (대학교 신축기숙사의 휘발성유기화합물 농도 및 새집증후군 반응)

  • Choi, Yoon-Jung;Kim, Jung-Jae;Jang, Yoon-Jeong;Oh, Ye-Seul
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2008.11a
    • /
    • pp.255-260
    • /
    • 2008
  • The purposes of this study were to determine the actual state of the indoor air quality by TVOC concentration and residents' responses and to analyze the influencing factors of IAQ in newly built university dormitory. The field measurements on the levels of TVOC and HCHO were carried out three times at an interval of 4 weeks in 3 rooms of a dormitory. The questionnaire survey on the residents that inquired into the lifestyle, the consciousness related to IAQ, and the responses of SHS was fulfilled. According to the results, the level of TVOC was approximately $0.14{\sim}18.5ppm$ and HCHO was $0.23{\sim}6.89ppm$ during 3 month since construction completion, which are seriously in excess of standard level, and seemed to be on the decrease as time goes by. The factors influencing the differences of the levels of TVOC or HCHO were the amount of ventilation including infiltration, heating temperature, relative humidity, or the use of living things including chemical. However, the residents rarely felt the responses of SHS and did not be conscious of the importance of ventilation.

  • PDF

The Actual State of TVOC and the Responses of Sick House Syndrome in Newly Built University Dormitory (대학교 신축 기숙사의 휘발성유기화합물 농도 및 새집증후군 반응)

  • Choi, Yoon-Jung;Oh, Ye-Seul;Jang, Yoon-Jeong;Kim, Jung-Jae
    • Journal of the Korean housing association
    • /
    • v.20 no.6
    • /
    • pp.135-143
    • /
    • 2009
  • The purposes of this study were to determine the actual state of the indoor air quality by measuring TVOC Concentration and surveying residents' responses in a newly built university dormitory and to analyze the influencing factors of IAQ. Field measurements on the concentrations of TVOC and HCHO were carried out three times at 4 week intervals in 3 rooms of a dormitory. A questionnaire survey was conducted on residents which inquired into the resident's lifestyle, their consciousness of IAQ, and the responses to SHS. According to the results, TVOC concentrations were 0.14~18.5 ppm and HCHO concentrations were 0.23~6.89 ppm during the 3 months following the completion of construction, showing a serious state in which standard levels are exceeded, though these levels seemed to decrease over time. The factors influencing the differences in the levels of TVOC and HCHO were the ventilation volume including infiltration, the heating temperature, relative humidity, or the use of living matter that include chemical ingredients. However, the residents rarely felt the symptoms of SHS and were not conscious of the importance of ventilation.

A Study on the Mock up Test for Reduction of HCHO Using the Functional Gypsum Board (기능성 석고보드의 폼알데히드(HCHO) 저감성능 평가를 위한 실물시험(Mock up test)연구)

  • Kim, Hea-Jeong;Song, Kyoo-Dong;Lee, Yun-Gyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.12
    • /
    • pp.814-819
    • /
    • 2008
  • The purpose of this study was developing the building materials for creation the comfortable IAQ. By reducing formaldehyde(HCHO) known as the main factors of Sick House Syndrome. This material must be revealed the physical and eco-friendly performance, so this study set up the basic standards for building materials. The source of physical performance evaluation is Korea Industrial Standards and the base of environmental ability is the Eco Label considering certificated system related to an apartment house. Because the developed material was satisfied with the established standards, it was tested in mock-up room for obtaining the real date from indoor air. The mock-up test was conducted according environmental standard method for indoor air Quality of the ministry of environment. The result of this study were as follows; the functional building materials had a effect to reduce the formaldehyde concentration for a initial period without wall paper, so additional development is needed for application with the wall paper and the available period.

A Study on the Calculation of Ventilation Rate in Apartment House according to VOCs and HCHO Substances of Building Material and Furniture (건축 마감재와 가구재의 VOCs, HCHO 유해물질에 따른 공동주택 적정 환기량 산정에 관한 연구)

  • Choi Jeong-Min;Park Jin-Seok;Son Young-Hwan;Park Chang-Sub;Park Min-Yong;Lee Kyung-Hee
    • Journal of the Korean housing association
    • /
    • v.16 no.4
    • /
    • pp.101-108
    • /
    • 2005
  • Because of the airtightness of building, misuse of building materials and abuse of furniture, indoor air pollution problems have been increasingly concerned especially with apartment buildings. To improve the IAQ(Indoor Air Quality) in apartment building, this study was aimed at analyzing the factor of interior building material and furniture and calculating the ventilation rate of living room and bed room according to the surface area of interior building material and furniture in terms of VOCs(Volatile Organic Compounds) and HCHO(Formaldehyde). The results of this study are as follows; 1) In the concerned rooms, the living room has less pollution emission rate L(surface area/volume) than that of the bed room but, the living room needs more ventilation rate than that of the bed room because of built-in furniture in terms of VOCs and HCHO. 2) Built-in interior furniture is very important factor in IAQ problems of apartment building, but until now there is no provision about the built-in furniture, so that the provision must be regulated to control the IAQ. 3) To control the IAQ problem, the effective ventilation plans must be established according to the required ventilation rate by means of natural or mechanical ventilation method.

Differential Modification of Sperm Parameters by Various Volatile Organic Compounds

  • Choi, Dal-Woong;Sohn, Jong-Ryeul;Moon, Kyung-Whan;Byeon, Sang-Hoon;Yoo, Dong-Chul;Kim, Hi-Chol;Kim, Young-Whan
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2005.06a
    • /
    • pp.319-322
    • /
    • 2005
  • Porous building materials are not only sources of indoor air pollutants such as volatile organic compounds (VOCs) but they are also strong sinks of these pollutants. Volatile organic compounds have been implicated in impaired spermatogenesis, increase in the incidence of malformed sperm and decrease in the percentage of moving sperm. The aim of this study was to determine and compare the direct effects of various volatile organic compounds (phenol, formaldehyde; HCHO, ethanol, toluene, styrene) on motility and survival rate of human sperm in vitro. Semen samples from 3 health subjects were prepared using swim-up method and 1-10mM volatile organic compounds were added to the test medium. HCHO and phenol produced significant decreases in the motility and survival rate with a different potency. The most potent inhibition of motility and survival rate was observed after exposure to HCHO. Less than 1mM HCHO significantly inhibited sperm motility. When ethanol is added directly to sperm, at concentrations equivalent to that in serum after heavy drinking, these damaging effects were lowest compared with other volatile organic compounds. Present study shows that each compound has differential toxic potency to human sperm and we need special caution for the use of HCHO and phenol.

  • PDF

A study on the chemical emission of furnitures using the large chamber method (대형챔버에 의한 생활제품(가구류) 방출오염물질 특성연구)

  • Park, Jae-Hyoung;Knag, Yoon-Kyung;Lee, Yun-Gyu
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.742-747
    • /
    • 2008
  • Formaldehyde(HCHO) and total volatile organic compounds(VOCs) can cause adverse health effects to the building occupants and may contribute to symptoms of 'Sick Building Syndrome'. These chemical contaminants are emitted from furnishings and electronic equipments as well as building materials. The purpose of this study is to measure and analyze VOCs and HCHO emission concentration from furnitures composed of wood materials including various chemicals by the large chamber method. This paper presents experiment results on the emission concentration of TVOCs and HCHO released from furnitures, such as bed, kitchen, sofa and table by a large chamber($24m^3$). The temperature and air humidity in the chamber are controlled to $25{\pm}1{\circ}C$ and $50{\pm}5%$ for this experiment. When the air change rate is $0.5hr^{-1}$, the background concentrations within the large chamber are below $50{\mu}g/m^3$ for TVOC, $5{\mu}g/m^3$ for HCHO and individual VOCs. The study is investigated the characterization of the chemical emission TVOC and HCHO concentrations and unknown VOCs from 6 furnitures.

  • PDF