• Title/Summary/Keyword: HANARO

Search Result 488, Processing Time 0.023 seconds

Analysis on Pool Temperature Variation along Pool Water Management System Operation in Research Reactor (연구용원자로에서 수조수관리계통 운전에 따른 수조수 온도 해석)

  • Choi, Jungwoon;Lee, Sunil;Park, Ki-Jung;Seo, KyoungWoo
    • Transactions of the KSME C: Technology and Education
    • /
    • v.5 no.2
    • /
    • pp.135-143
    • /
    • 2017
  • The domestic unique research reactor, HANARO (Hi-flux Advanced Neutron Application ReactOr), has been constructed with the open-pool, the core is submerged in, for the multi-purpose neutron application. The reactor has a primary cooling system to remove the fission heat from the core and its connected fluidic systems. Since the works are required at the reactor pool top as a characteristic of the research reactor, the radiation shall be minimized with the operation of the hot water layer system to avoid unnecessary radiation exposure on the workers during work at the pool top. Moreover, the pool water management system is connected to the reactor pool to maintain the pool temperature below $50^{\circ}C$ to minimize the uprising radioactive gas or impurity from the colder pool bottom. For the efficient flow rate of the PWMS, the thermal capacity of heat exchanger is selected with 260 kW in the normal operation condition. In this paper, the modeling is formulated to figure out whether or not each pool temperature maintains below the temperature limit and the calculation results show that the designed PWMS heat exchanger has enough capacity with the design margin regardless of the reactor operation mode.

EPMA Analysis of Inter-reaction Layer in Irradiated U3Si-Al Fuels (EPMA를 이용한 U3Si/Al 조사 핵연료의 반응층 분석)

  • Jung, Yang-Hong;Yoo, Byung-Ok;Kim, Hee-Moon;Park, Jong-Man;Kim, Myung-Han
    • Analytical Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.355-362
    • /
    • 2004
  • Fission products and Inter reaction layer of $U_3Si-Al$ dispersion fuel, irradiated in HANARO research reactor with 121 kW/m of maximum liner power and 63 at% of average burn-up, was characterization by EPMA (Electron Probe Micro Analyzer). The fuel punching system developed by Irradiated Materials Examination Facility (IMEF) has used to make these samples for the EPMA. With this system a very small and thin specimen which is 1.57 mm in diameter and 2 mm in thickness respectively has been fabricated to protect the EPMA operator from high radioactive fuel and to mini-mize the equivalent dose rate less than 150 mSv/h. EPMA was performed to observe layers of sectional, Inter-reaction and oxide with specimens of cutting and polished. Stoichiometry in the Inter-reaction layer with $16{\mu}m$ of thickness was $U_{2.84}$ Si $Al_{14}$ with calibration of $UO_2$ and $U_{3.24}$ Si $Al_{14.1}$ with calibration of standard specimen. metallic precipitates in this layer were not observed using fission products examination.

Convergence Effects of Proprioceptive Neuromuscular Facilitation on Dynamic Balance in Chronic Stroke : A Meta-Analysis (고유수용성신경근촉진법이 만성 뇌졸중 환자의 동적 균형에 미치는 융복합적 효과: 메타분석)

  • Park, Se-Ju;Lee, So-In;Jung, Ho-Jin
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.4
    • /
    • pp.275-284
    • /
    • 2021
  • The study attempted to systematically and comprehensively analyze individual studies in which proprioceptive neuromuscular facilitation (PNF) was performed with chronic stroke patients. Selection criteria included type of participants (stroke patients), intervention (PNF), comparison (intervention group or non-intervention group), outcomes (effect on dynamic balance), and study design (randomized controlled trial). We searched seven literature databases, and selected 17 papers that met our selection criteria. For meta-analysis, effect size of each individual study was extracted using the R project for Statistical computing version 4.0.3. Rob 2.0 tool, developed by the Cochrane group, was used to evaluate the quality of each individual study. The overall effect size PNF with dynamic balance was 0.59 (95% CI=0.41-1.77), which was significantly different than the median effect size (p<0.05). The sub-group for dynamic balance was analyzed, for effect sizes of BBS (0.50), TUG (0.78), and FRT (0.51). Thus, PNF intervention has a positive impact on improve of dynamic balance by chronic stroke patients.

Change of Voice Parameters After Thyroidectomy Without Apparent Injury to the Recurrent Laryngeal or External Branch of Superior Laryngeal Nerve: A Prospective Cohort Study

  • Lee, Doh Young;Choe, Goun;Park, Hanaro;Han, Sungjun;Park, Sung Joon;Kim, Seong Dong;Kim, Bo Hae;Jin, Young Ju;Lee, Kyu Eun;Park, Young Joo;Kwon, Tack-Kyun
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.33 no.2
    • /
    • pp.89-96
    • /
    • 2022
  • Background and Objectives The quality of life after thyroidectomy, such as voice change, is considered to be as important as control of the disease. In this study, we aimed to evaluate changes in both subjective and objective voice parameters after thyroidectomy resulting in normal morbidity of the vocal cords. Materials and Method In this prospective cohort study, 204 patients who underwent thyroidectomy with or without central neck dissection at a single referral center from Feb 2015 to Aug 2016 were enrolled. All patients underwent prospective voice evaluations including both subjective and objective assessments preoperatively and then at 2 weeks, 3, 6, and 12 months postoperatively. Temporal changes of the voice parameters were analyzed. Results Values of the subjective assessment tool worsened during the early postoperative follow-up period and did not recover to the preoperative values at 12 months postoperatively. The maximal phonation time gradually decreased, whereas most objective parameters, including maximal vocal pitch (MVP), reached preoperative values at 3-6 months postoperatively. The initial decrease in MVP was significantly greater in patients undergoing total thyroidectomy, and their MVP recovery time was faster than that of patients undergoing lobectomy (p=0.001). Patients whose external branch of the superior laryngeal nerve was confirmed intact by electroidentification showed no difference in recovery speed compared with patients without electroindentification (p=0.102), although the initial decrease in MVP was lower with electroidentification. Conclusion Subjective assessment in voice quality and maximal phonation time after thyroidectomy did not show recovery to preoperative values. Aggravation of MVP was associated with surgical extent and electroidentification.

Chemical characteristics and sources of fine ambient particulate matter from the third and fourth industrial complex area of Daejeon city, Korea (대전 3, 4 공단지역의 미세분진에 대한 화학적 특성과 오염원 연구)

  • Lim, Jong-Myoung;Lee, Jin-Hong;Chung, Yong-Sam
    • Analytical Science and Technology
    • /
    • v.20 no.1
    • /
    • pp.33-40
    • /
    • 2007
  • This study centered on the quantitative analysis of about 27 trace elements including toxic ones using instrumental neutron activation analysis of fine ambient particulate matter in the third and fourth industrial complex area of Daejeon city, Korea. For analytical quality control, the certified reference material (NIST, the National Institute of Standards and Technology, U.S.A., SRM 2783, air particulate on filter media) was used. The errors relative to SRM values of Sb, Mn, V, Mg, Na, K, Ti, Co, Zn, and Sm fell below 5%, while those of Cr, Fe, Ba, Th, Ce, Al, and Cu were less than 10%. From the results of the quantitative analysis, the concentration of toxic metals such as As, Mn, Se, V, and Zn were $3.26{\pm}2.72$, $9.86{\pm}4.71$, $2.18{\pm}1.25$, $4.91{\pm}2.41$, $158{\pm}78ng/m^3$, respectively. And the results of factor analysis indicated that there are no more than six factors of sources of fine ambient particulate with statistical significance in the study area.

A Case Study of Software Architecture Design by Applying the Quality Attribute-Driven Design Method (품질속성 기반 설계방법을 적용한 소프트웨어 아키텍처 설계 사례연구)

  • Suh, Yong-Suk;Hong, Seok-Boong;Kim, Hyeon-Soo
    • The KIPS Transactions:PartD
    • /
    • v.14D no.1 s.111
    • /
    • pp.121-130
    • /
    • 2007
  • in a software development, the design or architecture prior to implementing the software is essential for the success. This paper presents a case that we successfully designed a software architecture of radiation monitoring system (RMS) for HANARO research reactor currently operating in KAERI by applying the quality attribute-driven design method which is modified from the attribute-driven design (ADD) introduced by Bass[1]. The quality attribute-driven design method consists of following procedures: eliciting functionality and quality requirements of system as architecture drivers, selecting tactics to satisfy the drivers, determining architectures based on the tactics, and implementing and validating the architectures. The availability, maintainability, and interchangeability were elicited as duality requirements, hot-standby dual servers and weak-coupled modulization were selected as tactics, and client-server structure and object-oriented data processing structure were determined at architectures for the RMS. The architecture was implemented using Adroit which is a commercial off-the-shelf software tool and was validated based on performing the function-oriented testing. We found that the design method in this paper is an efficient method for a project which has constraints such as low budget and short period of development time. The architecture will be reused for the development of other RMS in KAERI. Further works are necessary to quantitatively evaluate the architecture.

Iron Status According to Serum Selenium Concentration and Physique in Young Female Adults (젊은 여성의 혈청 셀레늄 농도 및 체격에 따른 체내 철 수준)

  • Lee, Ok-Hee;Chung, Yong-Sam;Moon, Jong-Wha
    • Journal of Nutrition and Health
    • /
    • v.43 no.2
    • /
    • pp.114-122
    • /
    • 2010
  • Se and Fe are trace minerals acting as antioxidant scavenging free radicals. Iron deficiency is the most frequently reported nutritional deficiency in females. Body iron status are known to be dependent not only upon dietary iron intake, but also upon micro-mineral nutrition and obesity. Antioxidants such as selenium are reported to play an important role on the regulation of erythropoiesis by protecting RBC membrane from antioxidative damage. In this study, iron status in young females and its relationships with selenium status and physique were examined. Serum selenium and iron concentrations were measured by HANARO research reactor using neutron activation analysis method (NAA-method). The proportion with iron deficiency and anemia were 27.1% and 8.6%, respectively in young females, but the proportion with iron deficient anemia was 1.4%. The mean serum selenium level was $12.0\;{\mu}g/dL$ and in normal range in the young women. The study participants were tertiled according to BMI and serum selenium levels. Serum ferritin and iron levels inclined with increasing BMI tertiles. Serum iron and RBC count were higher in middle selenium group than low selenium group. Individuals had significantly lower hematocrit level in the lowest tertile for their serum selenium levels compared with the highest tertile. The serum ferritin level was predicted 25% by BMI and RBC count 26.2% by the serum selenium level and body fat%. In conclusion, this study shows that body iron status in young adult females are influenced by obesity and body selenium status.

Development of B4C Thin Films for Neutron Detection (스퍼터링 코팅기법을 이용한 중성자 검출용 B4C 박막 개발)

  • Lim, Chang Hwy;Kim, Jongyul;Lee, Suhyun;Cho, Sang-Jin;Choi, Young-Hyun;Park, Jong-Won;Moon, Myung Kook
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.2
    • /
    • pp.79-86
    • /
    • 2015
  • $^3He$ gas has been used for neutron monitors as the neutron converter owing to its advantages such as high sensitivity, good ${\gamma}$-discrimination capability, and long-term stability. However, $^3He$ is becoming more difficult to obtain in last few years due to a global shortage of $^3He$ gas. Accordingly, the cost of a neutron monitor using $^3He$ gas as a neutron converter is becoming more expensive. Demand on a neutron monitor using an alternative neutron conversion material is widely increased. $^{10}B$ has many advantages among various $^3He$ alternative materials, as a neutron converter. In order to develop a neutron converter using $^{10}B$ (actually $B_4C$), we calculated the optimal thickness of a neutron converter with a Monte Carlo simulation using MCNP6. In addition, a neutron converter was fabricated by the Ar sputtering method and the neutron signal detection efficiencies were measured with respect to various thicknesses of fabricated a neutron converter. Also, we developed a 2-dimensional multi-wire proportional chamber (MWPC) for neutron beam profile monitoring using the fabricated a neutron converter, and performed experiments for neutron response of the neutron monitor at the 30 MW research reactor HANARO at the Korea Atomic Energy Research Institute. The 2-dimensional MWPC with boron ($B_4C$) neutron converter was proved to be useful for neutron beam monitoring, and can be applied to other types of neutron imaging.