• Title/Summary/Keyword: H/T bolts

Search Result 20, Processing Time 0.025 seconds

A Comparison Study for the Fatigue Behavior of H/T and T/S Bolt Friction Joint (H/T 와 T/S 볼트 마찰이음의 피로거동 비교·검토)

  • JUN, Je Sang;WOO, Sang Ik;LEE, Seong Heang;JUNG, Kyoung Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.8 no.3 s.28
    • /
    • pp.139-150
    • /
    • 1996
  • H/T(High Tension) bolt is generally being used in joining the members of steel structure. It has some difficulties in management such as an adequate fastening force and a selection of proper instrument for fastening. T/S(Torque Shear Type High Tension) bolt which is more convenient and easier than H/T bolt in quality control has recently been developed. T/S bolts are produced and widely used these days in domestic, but those have not a detail regulation for their on. Those are only being used according to the specification for the H/T bolts. In this study, we tried to confirm the soundness of T/S bolts by the fatigue test of the modified specimens. First, we measured the reduction rate of the initial axial force with time at bolts. Second, we investigated the slip forces of bolts when the test specimen is loaded in tension. Third, we implemented the fatigue tests. During the test, we measured the variation of the axial forces of bolts under the cyclic loading. Finally, we compared and analyzed the fatigue behavior of H/T and T/S bolt, by S-N curve diagrams that are obtained in this study.

  • PDF

Experimental study on the Behavior CFT Column to H-Beam Endplate Connections with Penetrated High Strength Bolts (II) (관통형 고력볼트를 사용한 엔드플레이트형식 콘크리트 충전 각형강관 기둥.H형강 보 접합부의 거동에 관한 실험적 연구 (II))

  • Kim, Jae Keon;Moon, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.11 no.2 s.39
    • /
    • pp.109-116
    • /
    • 1999
  • This paper presents an experimental study on the behavior of CFT Column to H-Beam Endplate Connections with penetrated H/T bolts under monotonic loading. The object of this study is to estimate accurately the effect about the thickness of endplate and the arrangement of H/T bolts which was not got a grip on the results reported in the previous paper. Main parameters are the thickness of endplates (12mm, 16mm) and the arrangemement of H/T bolts (EP1, EP2, EP3 Type). The experimental results compared and analysed. 1) The specimens were classified by Bjorhovde's and EC3's method. 2) A formula to predict the ultimate moment of connection was derived based on the T-stub model, and theoretical value $(_tM_u)$ computed by the formula corresponded to the experimental value $(_eM_u)$.

  • PDF

Manufacturing Process Design of High Strength Al 6056 Bolts by Strain Hardening Effect (가공경화를 이용한 고강도 Al 6056 볼트의 생산 공정설계)

  • Park, J.S.;Kim, Y.B.;Kim, S.W.;Kim, H.S.;Ann, K.H.;Park, J.S.;Kang, J.H.
    • Transactions of Materials Processing
    • /
    • v.30 no.4
    • /
    • pp.165-171
    • /
    • 2021
  • This study was conducted on the manufacturing method of high-strength aluminum bolts. We obtained the displacement-load information by tensile test of the Al 6056 raw material and the T6 heat-treated material and calculated the precise flow stress and fracture limit using repetitive finite element analysis for before and after heat treatment. We designed a multi-stage forging process for T6 heat-treated material, and calculated that the accumulated damage value does not exceed fracture limits by finite element method. We produced the prototype forgings without any harmful defects such as cracks and folding occurring. Bolts made of T6 heat treated material show 9.6%higher tensile strength than T6 heat treated material after wire drawing.

Manufacturing Technology of Titanium Alloy Bolts Using Warm Forging Process (온간 단조공정을 이용한 타이타늄합금 볼트 제조기술)

  • Lim, S.G.;Kim, J.H.;Kim, J.H.;Lee, C.H.;Bong, J.K.;Yeom, J.T.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.10a
    • /
    • pp.80-81
    • /
    • 2009
  • Ti-6Al-4V alloy has been widely used for aerospace and power generation applications because of low density and attractive mechanical and corrosion resistant properties. However, the titanium alloy bolt is generally manufactured by cutting and rolling because of their poor workability. In order to achieve the mass production of titanium alloy bolts, it needs to be solved some manufacturing problems such as the sticking between workpiece and dies, the formation of the forming defects during the forging and so on. In this study, the manufacturing technology of titanium alloy bolts using warm forging process was introduced. The aim of present work is to develop a warm forging technology for high strength Ti-6Al-4V bolts.

  • PDF

Study on Assembly of TF Coil Structure in KSTAR Tokamak (KSTAR 토카막 장치에서 TF 자석 구조물의 조립에 관한 검토)

  • Kim, K.M.;Choi, C.H.;Hong, K.H.;Yang, H.L.;Yu, I.K.;Her, N.I.;Sa, J.W.;Kim, H.K.;Kim, G.H.;Kim, S.T.;Kim, H.T.;Yang, J.S.;Bak, J.S.;Kim, C.H.
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1262-1267
    • /
    • 2003
  • TF magnet structures are the main structural components in the KSTAR magnet systems to protect the superconducting coils from mechanical, electrical, and thermal loads. TF coil structure supports CS and PF coil system. The inter-coil structure contains adjustable shear keys and conical bolts to provide pre-loading in toroidal direction and to resist against in-plane and out-of-plane forces that are the most critical loads on the TF magnet system. The conical bolts and shear keys are specially designed to assemble easily and to provide a convenient accommodation for a good alignment. The connection plate that is one of the prototype fabrications had been manufactured to study adjustability of conical bolts and shear keys for assembly of TF coil structure. We could measure the misalignments at the keyways and conical holes with the misalignment measuring instrument.

  • PDF

Performance Evaluation of Connection of Seismic Rectangular Steel Tube Column-H Beam Using One-side Bolts (원사이드 볼트를 이용한 내진 각형강관 기둥-H형강 보 접합부의 구조성능평가)

  • Shim, Hyun-Ju;Jang, Bo-Ra;Chung, Jin-An;Lee, Eun-Taik
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.4
    • /
    • pp.355-363
    • /
    • 2010
  • The objective of this study is to examine the structural performance on the Rectangular Steel Tube Column-to-H Beam connections using one-side bolts and T-stub. Although a rectangular steel tube comparing with a H-shaped steel has many advantages and is more efficient, its application is limited due to the lack of experiences and connection details. Existing steel moment connections using the rectangular steel tube are mainly using through plate diaphragms. Its processing of construction is so complicated that it is hard to apply in the field. In this study, the structural performance and the earthquake capacity for T-stub connection with one-side bolts were investigated. And it is performed a comparative analysis of strength, rigidity, total rotation and energy absorption capacity for the various connection details.

Feasibility study for blind-bolted connections to concrete-filled circular steel tubular columns

  • Goldsworthy, H.M.;Gardner, A.P.
    • Structural Engineering and Mechanics
    • /
    • v.24 no.4
    • /
    • pp.463-478
    • /
    • 2006
  • The design of structural frameworks for buildings is constantly evolving and is dependent on regional issues such as loading and constructability. One of the most promising recent developments for low to medium rise construction in terms of efficiency of construction, robustness and aesthetic appearance utilises concrete-filled steel tubular sections as the columns in a moment-resisting frame. These are coupled to rigid or semi-rigid connections to composite steel-concrete beams. This paper includes the results of a pilot experimental programme leading towards the development of economical, reliable connections that are easily constructed for this type of frame. The connections must provide the requisite strength, stiffness and ductility to suit gravity loading conditions as well as gravity combined with the governing lateral wind or earthquake loading. The aim is to develop connections that are stiffer, less expensive and easier to construct than those in current use. A proposed fabricated T-stub connection is to be used to connect the beam flanges and the column. These T-stubs are connected to the column using "blind bolts" with extensions, allowing installation from the outside of the tube. In general, the use of the extensions results in a dramatic increase in the strength and stiffness of the T-stub to column connection in tension, since the load is shared between membrane action in the tube wall and the anchorage of the bolts through the extensions into the concrete.

An experimental study on the Behaviour of Concrete-Filled Square Steel Tubular Column·H-Beam End-plate Connections with Penetrated HT-Bolts (관통형 고력볼트를 사용한 엔드플레이트형식 콘크리트 충전 각형강관 기둥-H형강 보 접합부의 거동에 관한 실험적연구)

  • Kim, Jae Keon;Lee, Myong Jae;Lee, Seung Joon;Moon, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.10 no.2 s.35
    • /
    • pp.211-219
    • /
    • 1998
  • The objective of this study is to investigate the structural behavior of Concrete-Filled Tubular Column H-Beam End-Plate Connections with Penetrated HT-Bolts under monotonic load. Simple bending tests are carried out with 5 kinds of specimens including beam specimen. The parameters of these tests are the thickness (T=22, 26. 30mm) of End-plates and the diameter (M=20, 22mm) of bolts. From the tests, the increasing values of yielding strength and initial stiffness of each specimen were gained as the thickness of End-plates and diameter of bolts are increasing. And the application of Bjorhovde et al and Eurocode 3 classification method by non-dimensional moment-rotation curves to the connections showed that all of them are included in rigid region as far as initial stiffness is concerned and all of them are also rigid as far as ultimate strength.

  • PDF

Compressive Stress Distribution of High Tension Bolted Joints (고장력 볼트 이음부의 내부 압축응력 분포)

  • Kim, Sung Hoon;Lee, Seung Yong;Choi, Jun Hyeok;Chang, Dong Il
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.2 s.31
    • /
    • pp.171-179
    • /
    • 1997
  • The high-tension bolted joints are clamped by the axial force which approaches the yielding strength. The introduced axial force is transmitted to the connection members pass through washer. The transferred load in connections is balanced to the compressive stress of plates, axial force in bolts and the external loads. In this mechanism, the compressive stress and slip load we dominated by the effective stiffness of bolted joints and plates. In general the effective stiffness is specified to product to the effective area and elasticity modulus in connections. In this reason, the conic projection formular which is assumed that the axial force in bolts is distributed to the cone shape and that region is related to the elastic deformation mechanism in connections, was proposed. But it conclude what kind of formula is justified. Therefore in this paper, the fatigue tests are performed to the high tension bolted joints and inspected to the phase on the friction face. And using the FEM and numerical method, it is analyzed and approximated to the compressive stress distribution and its region. Moreover, it is estimated to the effective area and to the relation the friction area to the effective compressive distribution region.

  • PDF

Study on behavior of T-section modular composite profiled beams

  • Ryu, Soo-Hyun
    • Steel and Composite Structures
    • /
    • v.10 no.5
    • /
    • pp.457-473
    • /
    • 2010
  • In this study, specimens were made with profile thicknesses and shear reinforcement as parameters. The bending and shear behavior were checked, and comparative analysis was conducted of the results and the theoretical values in order to see the applicability of T-section Modular Composite Profiled Beams (TMPB). In TMPB, the profiles of formwork functions play a structural role resisting the load. Also, the module concept, which is introduced into TMPB, has advantages: it can be mass-produced in a factory, it is lighter than an existing H-beam, it can be fabricated on the spot, and its section size is freely adjustable. The T1 specimens exhibited ductile behavior, where the whole section displayed strain corresponding to yielding strain at least without separation between modules. They also exhibited maximum strength similar to the theoretical values even if shear reinforcement was not applied, due to the marginal difference between shear strength and maximum bending monment of the concrete section. A slip between modules was incurred by shear failure of the bolts in all specimens, excluding the T1 specimen, and therefore bending moment could not be fully displayed.