• 제목/요약/키워드: H/D ratio

검색결과 2,220건 처리시간 0.04초

난방용 보일러에서 NG-H2 혼소율에 따른 열 및 공해 성능의 검토 (A Study on the Thermal and Pollution Performances of the Heating Boilers with NG-H2 Mixture Ratio)

  • 서준선;김영직;박준규;이창언
    • 한국수소및신에너지학회논문집
    • /
    • 제32권6호
    • /
    • pp.573-584
    • /
    • 2021
  • Hydrogen is evaluated as one of the new energy sources that can overcome the limitations and pollution problems of conventional fossil fuels. Although hydrogen is CO2-free, attention is required in NOx emission and flame stability in order to use hydrogen in existing gas fuel system. However, use of electric grids is an unrealistic strategy for decarbonization for residential and commercial heating. Instead, use of H2 that utilizes city gas grid is suggested as a reasonable alternative in terms of compatibility with existing systems, economic feasibility, and accessibility. In this study, the thermal efficiency and NOx performance of the boiler according to the H2 mixture ratio and vapor humidified ratio are reviewed for a humidified NG-H2 boiler that vapor humidity to combustion air. Mixed fuel with H2 (20%) is almost similar to NG in terms of efficiency, flame temperature, and pollution performance. Thus, it is expected to be directly compatible with the existing NG system. If the exhaust temperature of the H2 boiler is lowered to around 60℃ at a humidified ratio of 15-20%, the NOx emission concentration can be suppressed to about 5-10 ppm. The level of efficiency reaches 87% of the rated load efficiency, which is equivalent to the highest grade achievable.

페니토인-${\beta}$-시클로덱스트린 포접 복합체의 좌제에 관한 연구 (Studies on Suppositories of $Phenytoin-{\beta}-Cyclodextrin$ Inclusion Complexes)

  • 차재호;한건
    • Journal of Pharmaceutical Investigation
    • /
    • 제18권1호
    • /
    • pp.15-21
    • /
    • 1988
  • An inclusion complex of phenytoin (PT) with ${\beta}-cyclodextrin\;({\beta}-CyD)$ in molar ratio of 1 : 1 was prepared, and the interaction between host and guest molecules was confirmed by infrared spectrometry, differential scanning calorimetry and X-ray diffractometry. Suppositories were prepared by the fusion method. PT and $PT-{\beta}-CyD$ complex were added to PEG 1540 and Witepsol H-15 under the vigorous stirring at $40^{\circ}C$. Content uniformity was tested for different formulations of the PT suppositories. The release rates were dependent on the K.P. V dissolution apparatus and the dialyzing tubing method. Then, the release rates were increased in the following order: $PT-{\beta}-CyD$ complex in PEG 1540>PT in PEG 1540>$PT-{\beta}-CyD$ complex in Witepsol H-15>PT in Witepsol H-15. The area under the curve and maximum blood concentration after rectal administration were increased in the following order: $PT-{\beta}-CyD$ complex in PEG 1540>PT in PEG 1540>$PT-{\beta}-CyD$ complex in Witepsol H-15>PT in Witepsol-15.

  • PDF

엇갈리게 배열된 두 개의 수평관에서 수평 피치-직경비에 따른 자연대류 열전달 영향 (Effect of Horizontal Pitch-to-Diameter Ratio on the Natural-Convection Heat Transfer of Two Staggered Cylinders)

  • 채명선;허정환;정범진
    • 대한기계학회논문집B
    • /
    • 제36권3호
    • /
    • pp.259-268
    • /
    • 2012
  • 엇갈리게 배열된 두 개의 수평관의 수직 이격거리($P_v$/D)와 수평 이격거리($P_h$/D)를 변화시키며 자연대류 열전달을 실험적으로 측정하였다. 열/물질전달의 상사성을 이용하여 물질전달 실험을 수행하였고 난류영역까지 확장하였다. Pr 수 2,014, RaD 수 $1.5{\times}10^8\sim2.5{\times}10^{10}$, $P_v$/D는 1.02~5, $P_h$/D는 0~2 범위에서 수행하였다. 하단 수평관의 물질전달은 단일 수평관 상관식의 예측치와 일치하였다. 상단 수평관의 물질전달은 $P_v$/D가 작을 때, 하단 수평관에서 상승하는 플룸의 예열영향(Preheating effect)으로 인해 감소하였고, $P_h$/D가 증가하면 급격히 상승하였다. 그러나 $P_v$/D가 클 때, 상단 수평관의 물질전달은 하단 수평관의 플룸 속도영향으로 인하여 단일 수평관보다 컸고, $P_h$/D가 증가함에 따라 완만하게 감소하였다. $P_h$/D가 매우 증가하여도 굴뚝효과(Chimney effect)와 측면유동효과(Side flow effect) 인하여 상단 수평관의 열전달이 하단 수평관의 열전달보다 크게 나타났다.

사질토 지반에서 단일 강성말뚝의 수평거동에 대한 시공방법의 영향 (Effect of Pile Construction on Lateral Behavior of Single Rigid Pile in Sand)

  • 김병탁;김영수;서인식
    • 한국지반공학회논문집
    • /
    • 제15권6호
    • /
    • pp.29-44
    • /
    • 1999
  • 본 논문은 균질 및 비균질의 사질토 지반에서 항타 시공된 단일 강성말뚝의 수평거동에 대한 모형실험 결과들을 고찰하였다. 본 연구의 목적은 말뚝의 수평거동 특성에 대한 말뚝 시공상태 (Driven & Embedded), 말뚝 근입길이에 대한 하부지반의 두께비 (H/L),그리고 지반의 상대밀도의 영향에 관하여 실험적인 연구를 수행하고 이러한 영향들을 정량화 할 수 있는 실험결과를 얻었다. 모형 실험 결과들에 의하면, 수평거동은 느슨한 균질지반에서 시공방법에 상당히 의존하는 것으로 나타났다. 말뚝시공시 항타방법에 의존할 경우 균질지반에서는 느슨한 지반일수록 그리고 비균질 지반 $(E_{h1}/E_{h2}/=0.18)$에서는 상부층 두께가 클수록 수평변위 감소에 상당한 효과를 얻을 수 있으나, 최대 휨모멘트 감소는 수평변위 감소와 정반대의 결과를 나타냈다. 수평변위 측면에서, 매입말뚝에 대한 항타말뚝의 변위비 $(y_{Driven}y_{Embedded})$는 균질지반의 각 상대 밀도에 대하여 0.65-0.88 $(D_r=90%)$와 0.38-0.65 (D$_{r}$=61.8%)의 범위로 그리고 비균질지반에서 0.6-0.88 의 범위로 나타났다. 또한, 본 연구에서는 $y_D/y_E \;와\; NBM_D/MBM_E$에 대한 항타고와 H/L의 영향들을 모형실험 결과들로부터 실험식으로 제안하였다.

  • PDF

생태독성기준 미적용 업종 사업장 배출수 생태독성 수준 평가 (Evaluation of Effluent Toxicity which were Exempted from Applying of Ecotoxicity Criteria)

  • 김종민;신기식;이수형;이정서;이택준
    • 한국물환경학회지
    • /
    • 제33권2호
    • /
    • pp.197-202
    • /
    • 2017
  • This paper aimed to evaluate the test results of acute toxicity on effluent samples which were exempted from applying of ecotoxicity criteria. Total 316 effluent samples which were free from controlling of ecotoxicity regulation, were tested. Ratio of effluent samples which were exceeded the ecotoxicity criteria (TU > 1) indicated 23.7%. This ratio was a little bit higher than previous study (22.7%) on effluent samples which were controlled under ecotoxicity criteria. These results mean that our ecotoxicity management system is not appropriate and applying of ecotoxicity criteria to all effluent samples (82 industry categories) were needed in order to improve our ecotoxicity system. In addition, the same numeric criteria (TU 1 or 2) for all industry categories were proposed in consideration of these results. Ratio of effluent samples which exceeded the ecotoxicity criteria (TU > 1) with D. magna indicated 23.7%. However V. fischeri showed 14.6%. As a acute toxicity test organism, D. magna seemed to be more sensitive than V. fischeri. Ratio of samples which were exceeded TU 1 with D. magna by 24 h exposure period test indicated 35 %, whereas 48 h showed 41%.

Effects of oscillation parameters on aerodynamic behavior of a rectangular 5:1 cylinder near resonance frequency

  • Pengcheng Zou;Shuyang Cao;Jinxin Cao
    • Wind and Structures
    • /
    • 제38권1호
    • /
    • pp.59-74
    • /
    • 2024
  • Large Eddy Simulation (LES) is used to explore the influence of vibration frequency and amplitude on the aerodynamic performance of a rectangular cylinder with an aspect ratio of B/D=5 (B: breadth; D: depth of cylinder) at a Reynolds number of 22,000 near resonance frequency. In smooth flow conditions, the research employs a sequence of three-dimensional simulations under forced vibration with diverse frequency ratios fe / fo = 0.8-1.2 (fe : oscillation frequency; fo : Strouhal frequency when the rectangular cylinder is stationary ) and oscillation amplitudes Ah/D = 0.05 - 0.3. The individual influences of fe / fo and Ah/D on the characteristics of integrated and distributed aerodynamic forces are the focal points of discussion. For the integrated aerodynamic force, particular emphasis is placed on the analysis of the dependence of velocity-proportional component C1 and displacement-proportional component C2 of unsteady aerodynamic force on amplitude and frequency ratio. Near the resonance frequency, the dependencies of C1 and C2 on amplitude are stronger than that of frequency ratio. For the distributed aerodynamic force, the increase in frequency and amplitude promotes the position of the main vortex core and reattachment to the leading edge in the streamwise direction. In the spanwise direction, vibration enhances the spanwise correlation of aerodynamic force to weaken the three-dimensional effect of the flow field, and a lower frequency ratio and larger amplitude amplify this effect.

Slaughterhouse wastewater treatment in a bamboo ring anaerobic fixed-bed reactor

  • Tritt, Wolfgang P.;Kang, Ho
    • Environmental Engineering Research
    • /
    • 제23권1호
    • /
    • pp.70-75
    • /
    • 2018
  • A pilot scale anaerobic fixed-bed with a reactor volume of $2.8m^3$ was built to treat slaughterhouse wastewater. Bamboo rings were chosen as support media mainly because of their cheaper price in underdeveloped countries. Even with their lower porosity and specific surface, the reactor performance showed a maximum 95% COD removal efficiency at an organic loading rate (OLR) of $1kg\;COD/m^3-d$ with its corresponding hydraulic retention time (HRT) of 7.5 d. At a higher OLR of $4.0kg\;COD/m^3-d$, the COD removal efficiency of 75% was achieved with an HRT of 2 d. No big difference in COD removal efficiencies was found between the reactors operated in both upflow and downflow modes. Their operational behavior and effluent characteristics were similar. The effluent COD/TKN ratio of 6.67 at an OLR of $4.0kg\;COD/m^3-d$ was only marginal acceptable range for a subsequent biological denitrification process. Otherwise carbon supplementation is required at a lower OLR.

이온교환 칼럼 충진비의 변화가 도금폐수 중 니켈이온 흡착에 미치는 영향 (Effect of Packing Density of ion-Exchange on the Nickel Adsorption Column in Electroplating Rinse Water)

  • 황택성;이진혁
    • 폴리머
    • /
    • 제26권5호
    • /
    • pp.551-558
    • /
    • 2002
  • 술폰산형 섬유이온교환체를 이용하여 도금 폐수 중 니켈 이온 분리를 위해 각각의 조건에 따른 니켈 이온에 대한 흡착 특성을 관찰하였다. 술폰산형 섬유이온교환체의 함수율은 술폰화도 극성이 클수록 크게 나타났으며 이온교환용량은 술폰화도가 증가함에 따라 증가하였으며 술폰화도 16%에서 3.38 meq/g로 높게 나타났다. 니켈이온의 흡착은 pH 변화에 따라 크게 변화하지 않았고 모든 흡착은 10분 이내에 약 7.5 mg/min의 흡착속도로 매우 빠르게 평형에 도달하였다. 재생 시 흡착용량은 7회까지 3.15 meq/g으로 거의 100% 가까이 탈착되었으며 그 이상에서는 2.01 meq/g으로 약간 감소하는 것으로 보아 본 연구에 사용한 이온교환체는 내구성에 문제가 없는 것으로 판단되었다. 한편 흡착평형 시간은 L/D의 값이 증가함에 따라 선형적으로 증가하였으며, 최대 흡착용량은 각각 2.71∼3.01 meq/g으로 약간 증가하였고 L/D의 변화에 크게 영향이 없는 것으로 보아 L/D<2로 흡착칼럼의 설계가 가능할 것으로 사료되었다. 또한 이온교환 섬유의 충전비가 일정할 때 pH 변화에 따른 니켈 이온의 흡착량은 산성 pH에서는 큰 변화가 없는 것으로 보아 도금수세액의 pH가 산성인 점을 고려할 때 pH 5 이하가 적합한 것으로 판단되었다.

회전원판공정과 화학침전공정 조합을 이용한 유기물과 질소*인의 동시제거 (Integrated System of RBC-lime Precipiatation for Simultaneous Removal of Organics and Nutrients)

  • 박종안;허준무;손부순
    • 한국환경보건학회지
    • /
    • 제24권1호
    • /
    • pp.132-140
    • /
    • 1998
  • 회전원판공정(rotating biological contactorRBC)과 화학적 처리공정을 결합한 처리시스템을 이용하여 도시하수내 포함된 유기물과 영양염류를 제거할 경우에 수리학적 부하 (hydraulic loading)와 처리수 반송율 (recirculation rate)의 시스템 처리효율에 미치는 영향을 알아보고자 하였다. 각각의 수리학적 부하 0.031, 0.0535 및 0.076 $m^3/m^2/d에서 반송율을 100%, 200%, 300%로 변화시켰고, 질산화에 필요한 알카리도의 보충 및 화학적 처리를 위하여 lime(CaCO$_3$)을 가하여 유입수의 pH를 10.4-11.0으로 유지시켰다. 실험결과 수리학적 부하 0.0535 $m^3/m^2/d에서 BOD, COD의 제거효율이 가장 높게 나타났으며, 질산화 효율 및 질소 제거효율에서는 수리학작 부하 0.035 $m^3/m^2/d, 반송율 300%에서 가장 높았으며, 반송율별에서는 수리학적 부하를 고려할 때 300% 반송하는 것이 가장 높은 유기물 제거효율을 보였다. 반송율과 수리학적 부하를 증가시킬 경우에 발생되는 슬러지내 유기물 함량은 점점 증가하였고, 수리학적 부하 0.076 $m^3/m^2/d, 반송율 300%일 경우에는 유기물 함량이 47%로 매우 높았다. 이는 부하증가에 따른 미생물 성장의 증가와 더불어 수리학적 부하 증가에 따른 전단력의 증가가 영향을 미쳤기 때문이다. 인을 제거하기 위하여 pH를 10.4-11.0으로 유지시킨 경우에 인을 90%이상 제거할 수 있었으며, 유출수내 평균 SS농도는 40 mg/l를 상회하였다.

  • PDF