• Title/Summary/Keyword: Gutta-percha/AH 26 sealer

Search Result 26, Processing Time 0.028 seconds

EFFECT OF IRRIGATION METHODS ON THE ADHESION OF RESILON/EPIPHANY SEALER AND GUTTA-PERCHA/AH 26 SEALER TO INTRACANAL DENTIN (근관 세척법이 Resilon/Epiphany sealer와 Gutta-percha/AH 26 sealer의 근관 상아질과의 접착에 미치는 영향)

  • Kim, Seo-Kyong;Hwang, Yun-Chan;Hwang, In-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.2
    • /
    • pp.98-106
    • /
    • 2008
  • The purpose of this study was to evaluate whether intracanal irrigation method could affect the adhesion between intracanal dentin and root canal filling materials (Gutta-percha/AH 26 sealer and Resilon/Epiphany sealer). Thirty extracted human incisor teeth were prepared. Canals were irrigated with three different irrigation methods as a final rinse and obturated with two different canal filling materials (G groups: Gutta-percha/AH 26 sealer, R groups: Resilon/Epiphany sealer) respectively. Group G1, R1-irrigated with 5.25% NaOCl Group G2, R2-irrigated with 5.25% NaOCl, sterile saline Group G3, R3-irrigated with 5.25% NaOCl, 17% EDTA, sterile saline Thirty obturated roots were horizontally sliced and push-out bond strength test was performed in the universal testing machine. After test, the failure patterns of the specimens were observed using Image-analyzing microscope. The results were as follows. 1. Gutta-percha/AH 26 sealer groups had significantly higher push-out bond strength compared with the Resilon/Epiphany sealer groups (p < 0.05). 2. Push-out bond strength was higher when using 17% EDTA followed by sterile saline than using NaOCl as a final irrigation solution in the Resilon/Epiphany sealer groups (p < 0.05). 3. In the failure pattern analysis, there was no cohesive failure in Group G1, G2, and R1. Gutta-percha/AH 26 sealer groups appeared to exhibit predominantly adhesive and mixed failure patterns, whereas Resilon/Epiphany sealer groups exhibited mixed failures with the cohesive failure occurred within the Resilon substrate.

APICAL SEALING OF THERMAFIL OBTURATORS IN CURVED CANALS (만곡근관에서 Thermafil의 근단폐쇄성에 관한 실험적 연구)

  • Ha, Joo-Hee;Choi, Gi-Woon
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.2
    • /
    • pp.671-684
    • /
    • 1995
  • The purpose of this study was to compare the apical sealing ability, overfilling and obturation of lateral canals using two gutta-percha techniques: Thermafil obturators and cold lateral condensation. Eighty numbered epoxide blocks with one major and five lateral canals were divided into four experimental groups and obturated according to experimental groups. Four experimental groups were as follows: Group 1 : Filling with Thermafil plastic obturators and sealer(ThermaSeal) Group 2 : Filling with Thermafil plastic obturators only, without sealer(ThermaSeal) Group 3 : Fillng using lateral condensation with sealer(AH-26) Group 4 : Fillng using lateral condensation without sealer(AH-26) All the blocks were stored in 100% relative humidor at room temperature for 7 days. Each block was placed in centrifuge tube filled with India ink, and then centrifuged for 20 minutes at 3,000 rpm. Apical leakage was measured from the apical foramen to the most coronal level of dye penetration in millimeter under a stereoscope. The length of gutta-percha and sealer in each of the lateral canals was measured, too. The presence or absence of overfilling of gutta-percha and sealer was recorded. The data was analyzed by one-way ANOVA. The obtained results were as follows: l. Apical dye leakage was almost: not occurred in Group Willed with Thermafil and sealer) and Group 3(filled using lateral condensation with sealer), and there was no significant difference in linear leakage between two groups(p>0.01). 2. In both Thermafil and lateral condensation groups, linear leakage of Group I, 3(filled with sealer) was less than that of Group 2, 4(filled without sealer), and there was no significant difference in linear leakage between Group 1, 2, 3(p> 0.01). 3. Overfilling during obturation of Group 1, 2(filled with Thermafil) was more than Group 3, 4(filled using lateral condensation), and there was no significant difference between groups(p> 0.05). 4. Groups filled with Thermafil had significantly more gutta-percha than groups filled using lateral condensation in all lateral canals(p <0.01), the total length of gutta-percha and sealer found in all lateral canals were similar in Group 1 and Group 3.

  • PDF

Retreatability of two endodontic sealers, EndoSequence BC Sealer and AH Plus: a micro-computed tomographic comparison

  • Oltra, Enrique;Cox, Timothy C.;LaCourse, Matthew R.;Johnson, James D.;Paranjpe, Avina
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.1
    • /
    • pp.19-26
    • /
    • 2017
  • Objectives: Recently, bioceramic sealers like EndoSequence BC Sealer (BC Sealer) have been introduced and are being used in endodontic practice. However, this sealer has limited research related to its retreatability. Hence, the aim of this study was to evaluate the retreatability of two sealers, BC Sealer as compared with AH Plus using micro-computed tomographic (micro-CT) analysis. Materials and Methods: Fifty-six extracted human maxillary incisors were instrumented and randomly divided into 4 groups of 14 teeth: 1A, gutta-percha, AH Plus retreated with chloroform; 1B, gutta-percha, AH Plus retreated without chloroform; 2A, gutta-percha, EndoSequence BC Sealer retreated with chloroform; 2B, gutta-percha, EndoSequence BC Sealer retreated without chloroform. Micro-CT scans were taken before and after obturation and retreatment and analyzed for the volume of residual material. The specimens were longitudinally sectioned and digitized images were taken with the dental operating microscope. Data was analyzed using an ANOVA and a post-hoc Tukey test. Fisher exact tests were performed to analyze the ability to regain patency. Results: There was significantly less residual root canal filling material in the AH Plus groups retreated with chloroform as compared to the others. The BC Sealer samples retreated with chloroform had better results than those retreated without chloroform. Furthermore, patency could be re-established in only 14% of teeth in the BC Sealer without chloroform group. Conclusion: The results of this study demonstrate that the BC Sealer group had significantly more residual filling material than the AH Plus group regardless of whether or not both sealers were retreated with chloroform.

MEASUREMENT OF ADHESION OF ROOT CANAL SEALER TO DENTINE AND GUTTA-PERCHA (상아질과 Gutta-Percha에 대한 근관충전용 Sealer의 결합강도의 측정)

  • Her, Mi-Ja;Yu, Mi-Kyung;Lee, Se-Joon;Lee, Kwang-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.1
    • /
    • pp.89-99
    • /
    • 2003
  • The purpose of this study was to investigate the bonding of resin- based root canal sealer, AH26 when the sealer was applied as a thin layer between dentine and gutta-percha surface. In this study forty non-caries extracted human molars and resin-based root canal sealer(AH 26, DeTrey/Dentsply, Germany) were used. Disks of gutta-percha, 6mm in diameter.6mm thick (Diadent/Dentsply, Korea) for thermoplastic obturation were used and dentin surfaces were treated with 2% NaOCl(Group 1) or 2%NaOCl+17% EDTA(Group 3). Disks of gutta-Percha, 6mm in diameter.6mm thick (Diadent/Dentsply, Korea) for conventional obturation were used and dentin surface were treated with 2% NaOCl(Group 2) or 2%NaOCl+17% EDTA(Group 4). Enamel was removed by a horizontal section 1mm below the deepest portion of the central occlusal groove by using a watercooled low speed diamond saw. A second horizontal section was done around cementoenamel junction. Exposed dentin surface was cut to approximately $8{\times}8{\;}mm$ rectangular shape and was ground against 320, 400, 600 grade silicon carbide abrasive paper serially. After grinding, the dentine surface were soaked in a solution of 2% NaOCl for 30 minutes and twenty of specimens were treated with 17% EDTA solution for 1 minute. The treated specimens were washed and dried, Root canal sealer, AH26 was prepared according to the manufacture's instructions The Gutta-percha and dentin surface were coated with a thin layer of the freshly mixed seal or. The specimens were left overnight at room temperature. After their initial set, they were transferred to an incubator at $37$^{\circ}C$ for 72 h. After 72 hours, resin blocks were made. The resin block was serially sectioned vertically into stick of $1{\cdot}1mm$. Twenty sticks were prepared from each group. After that, tensile bond strength f3r each stick was measured with Microtensile Tester Failure patterns of the specimens at the interface between gutta-percha and dentin were observed under the SEM(x1000) and Stereomicroscope (LEICA M42O, Meyer Inst., TX U.S.A) at 1.25 x25 magnification. The results were statistically analysed by using a One-way ANOVA and Tukey's test. The results were as follows; 1. Tensile bond strengths($mean{\pm}SD$) were expressed with ascending order as follows: Group 1, $3.09{\pm}$ 1.05Mpa : Group 2, $6.23{\pm}1.16MPa$ : Group 3, $7.12{\pm}1.07MPa$ : Group 4, $10.32{\pm}2.06MPa$. 2. Tensile bond strengths of the group 2 and 4 used disks of gutta-percha for conventional obturation were significantly higher than that of the group 1 and 3 used fir thermoplastic obturation. (p < 0.05). 3. Tensile bond strengths of the group 3 and 4 treated with 2% NaOC1+17% EDTA were significantly higher than that of the group 1 and 2 treated with 2% NaOCl. (p < 0.05). 4. In analysis of failure patterns at the interface between sealer and gutta-percha, there were observed 49 (61%)cases of adhesive failure patterns and 31 (39%) cases of mixed failures patterns.

A STUDY OF SEALING ABILITY OF DENTIN BONDING AGENT AS ROOT CANAL SEALER (Dentin Bonding Agent의 근관폐쇄(根管閉鎖) 효과(效果)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Min, Hyo-Kie;Min, Byung-Soon;Choi, Ho-Young;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.13 no.1
    • /
    • pp.103-111
    • /
    • 1988
  • The purpose of this study was to, examine the sealing ability of the denting bonding agent, when used with gutta percha cone, as a root canal sealer. Seventy two upper and lower extracted human teeth with single root were randomly selected and instrumented in a conventional method with K-file. After instrumentation and dry the canal with paper point, there were divided into three groups and twenty four teeth in each group were filled with the following material; In group I: Scotchbond in combination with gutta percha cone. In group II: AH 26 in combination with gutta percha cone. In group III: Tubli-Seal in combination with gutta percha cone. All specimens were immersed in Indian Ink, decalcified, and cleared. The depth of dye penetration into the canals were evaluated by caliper at the intervals of 1 day, 1 week, 2 weeks. The results were as follows; 1. Depth of dye penetration for all groups increased with time. 2. As to difference in mean dye penetration at time interval of 1 day and 14 days, Scotchbond group exhibited the smallest value as 0.53mm and Tubli-Seal group exhibited the largest value as 0.70mm. 3. There was the difference of dye penetration between each group, but its difference was not significant, statistically.

  • PDF

IN VITRO STUDY ON APICAL SEAL AND SEM MORPHOLOGY IN CANALS FILLED WITH RESIN-BASED ROOT CANAL SEALER AND SELF-ETCHING PRIMER (SELF-ETCHING PRIMER와 레진계 근관 SEALER 사용시 근관벽의 형태와 치근단 근관밀폐에 대한 실험적 연구)

  • Kang, Sam-Hee;Park, Dong-Sung;You, Heyon-Mee;Oh, Tae-Seok
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.4
    • /
    • pp.543-549
    • /
    • 2000
  • Gutta-percha와 근관sealer를 사용한 근관 충전은 가장 많이 이용되고 성공률이 높은 방법이지만, 현재 사용되는 모든 근관sealer는 미세누출을 나타낸다. 따라서 더 효과적인 근관 폐쇄를 이루기 위한 재료 및 방법들이 연구되어왔다. 이중 상아질 접착제는 근관 충전재와 함께 사용되어 미세누출을 감소시키지만, 근관 내에 사용하기에 술식이 복잡하고 기술이 요구된다. 본 연구의 목적은 gutta-percha와 레진계 근관 sealer로 충전한 근관에서 self-etching primer를 미리 도포한 경우와 도포하지 않은 경우의 치근단 미세누출을 비교하고, self-etching primer를 도포함에 있어 근관 내에 적용하는 방법에 따른 미세누출을 비교하는 것이다. 또한 근관sealer와 상아질 계면을 주사전자현미경으로 관찰하여, 이 결과를 미세누출과 관련시켜보고자 하였다. 36개의 발거된 사람의 단근치에서 치관부를 절단, 제거하고 ProFile로 근관 형성한 후, 무작위로 선택하여 4개의 군으로 분류하였다. 1군에서는 주사기와 30게이지 주사 바늘로 self-etching primer를 근관 내에 적용하였고, 2군에서는 self-etching primer를 paper point에 적셔 근관 내에 적용하였다. 3군에서는 self-etching primer를 적용하지 않았다. 1, 2, 3군의 치아를 gutta-percha와 AH26 sealer를 사용하여 continuous wave 충전법으로 충전한 후 치근단공 주위 3mm를 제외한 치근변에 nail polish를 2회 도포하였고, 4군(음성 대조군)은 치근면 전체에 도포하였다. 1군과 2군에서 각각 2개의 치아는 주사전자현미경적 관찰을 위해 준비하였다. 모든 치아를 Methylene Blue 수용액에 48시간동안 침적, 수세한 후 치아 장축에 평행하게 양분하여 10배의 실물확대현미경 하에서 치근단 색소 침투를 관찰하였다. Self-etching primer를 도포한 군과 도포하지 않은 군 사이에는 평균 미세누출량에 유의한 차이가 없었다. 주사 바늘로 적용한 군과 paper point로 적용한 군 사이에도 평균 미세누출량에 유의한 차이가 없었다. 상아질과 근관 sealer계면의 주사전자현미경 관찰 결과 일부분에서 긴밀한 접착 관계를 나타내었고, 다른 부분에서는 간극을 나타내었다.

  • PDF

Push-out bond strength and dentinal tubule penetration of different root canal sealers used with coated core materials

  • Sungur, Derya Deniz;Purali, Nuhan;Cosgun, Erdal;Calt, Semra
    • Restorative Dentistry and Endodontics
    • /
    • v.41 no.2
    • /
    • pp.114-120
    • /
    • 2016
  • Objectives: The aim of this study was to compare the push-out bond strength and dentinal tubule penetration of root canal sealers used with coated core materials and conventional gutta-percha. Materials and Methods: A total of 72 single-rooted human mandibular incisors were instrumented with NiTi rotary files with irrigation of 2.5% NaOCl. The smear layer was removed with 17% ethylenediaminetetraacetic acid (EDTA). Specimens were assigned into four groups according to the obturation system: Group 1, EndoRez (Ultradent Product Inc.); Group 2, Activ GP (Brasseler); Group 3, SmartSeal (DFRP Ltd. Villa Farm); Group 4, AH 26 (Dentsply de Trey)/gutta-percha (GP). For push-out bond strength measurement, two horizontal slices were obtained from each specimen (n = 20). To compare dentinal tubule penetration, remaining 32 roots assigned to 4 groups as above were obturated with 0.1% Rhodamine B labeled sealers. One horizontal slice was obtained from the middle third of each specimen (n = 8) and scanned under confocal laser scanning electron microscope. Tubule penetration area, depth, and percentage were measured. Kruskall-Wallis test was used for statistical analysis. Results: EndoRez showed significantly lower push-out bond strength than the others (p < 0.05). No significant difference was found amongst the groups in terms of percentage of sealer penetration. SmartSeal showed the least penetration than the others (p < 0.05). Conclusions: The bond strength and sealer penetration of resin-and glass ionomer-based sealers used with coated core was not superior to resin-based sealer used with conventional GP. Dentinal tubule penetration has limited effect on bond strength. The use of conventional GP with sealer seems to be sufficient in terms of push-out bond strength.

THE INFLUENCE OF OBTURATION TIMING AND THICKNESS OF MINERAL TRIOXIDE AGGREGATE ON SEALING ABILITY OF CANAL WITH OPEN APEX (근관충전 시기와 MINERAL TRIOXIDE AGGREGATE의 APICAL MATRIX두께에 따른 치근단 밀폐도의 평가)

  • Kwak, Kyung-In;Park, Dong-Sung;Yoo, Hyeon-Mee;Oh, Tae-Seok
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.4
    • /
    • pp.536-542
    • /
    • 2000
  • 임상에서 점차 Mineral Trioxide Aggregate (MTA)에 대한 우수성이 소개되면서, apical matrix로의 사용은 주목할 만하다 할 수 있다. 본 연구의 목적은 개방형근관에서 MTA가 apical matrix로 사용될 때의 치근단 밀폐효과를 알아 보고, 근관충전의 시기와 matrix의 두께가 치근단 밀폐에 미치는 영향을 치근단 미세누출의 측면과 matrix탈락빈도의 측면에서 관찰하고자 하는 것이다. 개방형 근관을 재현하고자 45개의 발거된 단근치에 #90크기로 근단공을 형성하였고, 투명레진등을 이용하여 치근단 병소를 갖는 치조골을 재현한 후, 4개의 실험 군과 1개의 대조 군으로 분류하였다. A군: 2mm두께의 MTA matrix 형성후, 열연화된 Gutta-percha와 AH26 sealer를 이용하여 즉시 근관충전. B군: 2mm 두께의 MTA matrix 형성후, A군과 같은 방법으로 24시간 후 근관충전. C군: 4mm 두께의 MTA matrix 형성후, A군과 같은 방법으로 즉시 근관충전. D군: 4mm 두께의 MTA matrix 형성후, A군과 같은 방법으로 24시간 후 근관충전. 대조군: matrix를 사용하지 않고 열연화된 Gutta-percha와 AH26 sealer를 이용하여 근관충전하였다. Matrix의 탈락이 있는 경우 기록하고 완전 수세 후 다시 시행하였다. 색소침투정도의 평가를 위해 methylene blue에 치아를 48시간 침수시킨 후 협설로 양분하였다. 각 시편들을 고배율 현미경 관찰 후 비디오촬영 하였고, digitalized image analysing program을 이용하여 두명의 관찰자가 누출의 정도를 평가한 후, One-way ANOVA로 통계적 유의성을 검증하여 다음과 같은 결과를 얻었다. 1. Matrix를 사용한 실험 군이 matrix를 사용하지 않은 대조 군에 비해 유의성 있게 낮은 누출을 보였다(p<0.05). 그러나 근관충전시기와 matrix의 두께를 달리한 실험군 내에서는 누출에 유의성 있는 차이가 나타나지 않았다. 2. 모든 실험군에서 gutta-percha를 이용한 근관충전의 시기에 matrix탈락 및 gutta-percha의 압출은 발생하지 않았다.

  • PDF

The effects of total-etch, wet-bonding, and light-curing of adhesive on the apical seal of a resin-based root canal filling system (접착제의 접착변수가 레진계 근관충전제의 근단밀폐효과에 미치는 영향)

  • Ryu, Won-Il;Shon, Won-Jun;Baek, Seung-Ho;Lee, In-Han;Cho, Byeong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.5
    • /
    • pp.385-396
    • /
    • 2011
  • Objectives: This study evaluated the effects of adhesion variables such as the priming concepts of canal wall and the curing modes of adhesives on the sealing ability of a resin-based root canal filling system. Materials and Methods: Apical microleakage of the Resilon-RealSeal systems filled with 3 different combinations of adhesion variables was compared with the conventional gutta-percha filling using a dye penetration method. Experimental groups were SEDC, Resilon (Resilon Research LLC) filling with self-etch RealSeal (SybronEndo) primer and dual-cure RealSeal sealer; NELC, Resilon filling with no etching, Scotchbond Multi-Purpose (3M ESPE) primer application and light-curing adhesive; and TELC, Resilon filling with Scotchbond Multi-Purpose primer and adhesive used under total etch / wet bonding and lightcure protocols. GPCS, gutta-percha filling with conventional AH26 plus sealer, was the control group. Results: The median longitudinal dye penetration length of TELC was significantly shorter than those of GPCS and SEDC (Kruskal-Wallis test, p < 0.05). In the cross-sectional microleakage scores, TELC showed significant differences from other groups at 2 to 5 mm from the apical foramen (Kruskal-Wallis test, p < 0.05). Conclusions: When a resin-based root canal filling material was used, compared to the self-etching primer and the dual-cure sealer, the total etch/wet-bonding with primer and light-curing of adhesive showed improved apical sealing and was highly recommended.

Sealing Ability of Root Canals Obturated with Gutta-percha, Epoxy Resin-based Sealer, and Dentin Adhesives (에폭시레진계 봉함제와 상아질접착제로 근관충전시 미세누출에 관한 연구)

  • Kim, Hee-Jung;Baek, Seung-Ho;Bae, Kwang-Shik
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.1
    • /
    • pp.51-57
    • /
    • 2004
  • 본 연구는 에폭시레진계 봉함제 (AH26)과 두 가지의 상아질 접착제와 함께 근관충전을 시 행하였을 때와 에폭시레진계 봉함제 단독으로 사용하였을 때의 미세누출을 혐기성 세균모델을 이용하여 평가하였다. 52개의 단근치를 이용하여 .04, .06 taper Profile (Dentsply-Maillefer, Ballaigues, Swiss)을 사용하여 변형된 crown-down pressureless법으로 근관형성 하였다. 형성된 치근을 12개씩 무작위로 나누어 4개의 실험군으로 하였으며, 나머지 치아 중 2개를 양성대조군에, 2개는 음성대조군으로 사용하였다. 제1군은 All Bond 2(Bisco, Itasca, IL, USA)를 적용하고 거타퍼쳐와 AH26 (Dentsply, Konstanz, Germany)을 이용하여 continuous wave of condensation technique으로 근관충전 하였으며, 제 2군은Prime & Bond NT (Dentsply, Konstanz, Germany)를 적용 후 거타퍼쳐와 AH26을 이용하여 충전하였으며, 제3군은 17% EDTA를 적용하여 도말층을 제거한 후 거터퍼쳐 와 AH26을 사용하여 충전하였다. 제4군은 17% EDTA를 적용하지 않고 거터퍼쳐와 AH26을 사용하여 충전하였다. Fusobacterium nucleatum (VPI 10197)을 추적자로 이용한 혐기성세균모델을 사용하여 혐기성배양기에서 배양시키면서 60일 동안 각군에 대한 미세누출 여부를 관찰하였다. 매일 배양액의 혼탁도와 색상변화를 관찰하여 기록하였다. 제4군에서 통계학적으로 유의할만한 미세누출을 가장 많이 보였으며(p<0.0005) 나머지 3개의 실험군에서는 서로간의 통계학적으로 유의할 만한 차이를 보이지 않았다. 주사전자현미경 관찰 시 제 1군과 제2군의 상아질 접착제가 상아세관으로 침투한 소견을 관찰 할 수 있었다.