• Title/Summary/Keyword: Gunshots

Search Result 7, Processing Time 0.026 seconds

Improvement of Muzzle Localization Using Linear Microphone Array (선형마이크로폰 어레이를 이용한 총구 거리 추정 개선 방법)

  • Jung, Seong-Woo;Kim, Yang-Hann
    • The Journal of the Acoustical Society of Korea
    • /
    • v.34 no.1
    • /
    • pp.60-65
    • /
    • 2015
  • In this paper, we used the sound of gunshots recorded by multiple microphones to increase the accuracy of the calculation of the distance between sniper and the microphone array. This method is crucial for achieving military objectives. Gunshots are comprised of the explosion of driving gas from the muzzle and the supersonic shock wave from the flying bullet. The original distance calculation method compares the time difference of arrival and angle of incidence to estimate the sniper's location. The disadvantage of this method is that when the angles of incidence coincide the margin of error increases, to solve this problem we suggest a new method using the characteristic changes of the shock wave with the increase of perpendicular distance between the microphone and the trajectory of the bullet. This theory is verified by experiments.

Gunshot Injury to the Anterior Arch of Atlas

  • Park, Jun-Hee;Kim, Hyeung-Sun;Kim, Seok-Won;Do, Nam-Yong
    • Journal of Korean Neurosurgical Society
    • /
    • v.51 no.3
    • /
    • pp.164-166
    • /
    • 2012
  • Penetrating injuries to the upper cervical spine resulting from gunshots are rare in South Korea due to restrictions of gun use. Moreover, gunshot wounds to the upper cervical spine without neurological deficits occur infrequently because of the anatomic location and surrounding essential structures. We present an uncommon case involving the surgical removal of a bullet located in the anterior arch of first cervical vertebra (C1) via a transoral approach without neurological complications or subsequent mechanical instability.

Traumatic Aneurysm of the Callosomarginal Artery-Cortical Artery Junction from Penetrating Injury by Scissors

  • Kim, Myoung Soo;Sim, Sook Young
    • Journal of Korean Neurosurgical Society
    • /
    • v.55 no.4
    • /
    • pp.222-225
    • /
    • 2014
  • Traumatic intracranial aneurysms (TICAs) are rare and are associated with high rates of morbidity and mortality. TICAs usually result from head injuries caused by traffic accidents, industrial accidents, or gunshots. We report a traumatic aneurysm of the callosomarginal artery-cortical artery junction arising from a penetrating injury by scissors. A 51-year-old woman was admitted to our hospital after suffering a penetrating injury caused by scissors. Computed tomography (CT) and CT-angiography demonstrated a right orbital roof fracture, subarachnoid hemorrhage, frontal lobe hemorrhage, intraventricular hemorrhage, and a traumatic aneurysm of the right callosomarginal artery-cortical artery junction. We trapped the traumatic aneurysm and repositioned a galeal flap. Postoperative CT showed a small infarction in the left frontal lobe. Follow-up angiography two months later showed no residual aneurysm. We suggest that an aggressive surgical intervention be performed whenever TICA is diagnosed.

An Assessment for Anti-piercing Designs of RC Slabs against Small Caliber Bullets (소구경 탄자에 대한 철근콘크리트 슬래브의 관입저항력 평가)

  • Kim, Suk-Bong;Kang, Young-Chul;Lee, Jong-Chan;Baek, Sang-Ho;Park, Young-Jun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.10 no.2
    • /
    • pp.69-75
    • /
    • 2007
  • So far, anti-piercing depths for concrete slabs have been determined using Conventional Weapon's Effects Program(CONWEP) that was developed by the U. S. Army's Corps of Engineering. However, it has been suggested by a number of field officers that the values computed by CONWEP tend to be too high for protective facilities used in small military units and that indiscriminate application of these values to such facilities would lead to uneconomical penetration-proof designs. In this study, gunshots onto RC slabs were carried out using KM80 bullets in order to measure the piercing depths. The observed depths and the depths offered by the CONWEP system differed greatly from each other by up to 119 centimeters. Based on the depth values obtained through this experiment, we have proposed a new equation to calculate effective anti-piercing depths for RC slabs against small caliber bullets.

The Comparison of the Relationship between the Gunfire Shot and Its Resulting Heavy Metal Pollution Rate (소화기 사격장의 사격에 따른 중금속 오염도 비교(I))

  • Hong, Sung Tae;Hyun, Jae Hyuk
    • Journal of Soil and Groundwater Environment
    • /
    • v.19 no.6
    • /
    • pp.1-5
    • /
    • 2014
  • The following research was initiated in order to compare the relationship between the amount of gunfire shot and its resulting heavy metal pollution rate. The research was conducted at two firing ranges located inside a military unit stationed in the rear strategical area, where one full distance firing range is used by soldiers in active service, and the other is used by recruits and reserves. The heavy metal pollution rate was measured also on water sample collected from the target zone while raining. Based on values such as the real amount of gunshot fired, amount of heavy metal in the soil of the target zone, and the degree of heavy metal pollution for each firing range, the research showed that although pollution rate was higher when more gunshots were fired, there was no close correlation between the two. The water samples showed that this might result from the soils containing heavy metals eroded and transported by rain due to the target zone having no vegetation.

An Analysis of the Cotton Fabric armour(綿甲) in the late Joseon Korea - with Emphasis on the Remaining Artifact in the National Museum of Korea - (조선 후기 면갑(綿甲) 유물 분석 - 국립중앙박물관 소장 유물을 중심으로 -)

  • Park, Ga Young;Song, Mi Kyung
    • Journal of the Korean Society of Costume
    • /
    • v.63 no.4
    • /
    • pp.158-167
    • /
    • 2013
  • The cotton fabric armour for lower class soldiers can be found from the historical records of the mid-Joseon Korea. And the records show that the form and the structure of the armour was modified in the late 19th century in order to provide better protection from gunshots for the soldiers in the midst of the invasions from the West. This is a survey and research of the only artifact of the cotton fabric armour remaining in Korea - for its form, dimensions, and design. Using the historical records as reference, we can confirm the structure and characteristics of the cotton fabric armour of the Joseon period. This cotton fabric armour, preserved in National Museum of Korea, is a vest-type armour made of 30 layers of cotton. On the right shoulder, there is a button for tying knots and strings were tied under both armpits. On the surface of the cotton fabric armour there were some characters and patterns stamped in black. Presently, this artifact in Korea is the only specimen relic of its sort, but there are some other related relics in foreign countries including helmets and belts. Continuous researches would help extend the scope of armour study beyond the traditional researches that only focuses on the armours of the officials, thus helping us to understand the military costumes in traditional Korea.

Treatment of Open Proximal Humerus Fracture by Gunshot (총격에 의한 개방성 근위 상완골 골절의 치료 - 증례 보고 -)

  • Kim, Sung-Jae;Lee, Jae-Hoo;Chun, Yong-Min
    • Clinics in Shoulder and Elbow
    • /
    • v.15 no.1
    • /
    • pp.37-42
    • /
    • 2012
  • Purpose: To consider the proper management of proximal humerus fracture on gunshot wounds. Materials and Methods: A 28-year-old male patient, who sustained a gunshot injury on the left arm 5 days ago, was admitted through the emergency department. Although he underwent an emergency surgery (bullet fragment removal and debridement), there remained bullet fragments around the proximal humerus fracture site. The wound seemed to be infected and a partial dehiscence occurred. No neurologic deficit was noted. Immediate exploration and debridement were performed, and an external fixator was applied to restore the anatomical alignment and manage the wounds. Intravenous antibiotics were administered. On the 9th postoperative day, wound debridement was done again, and cement beads mixed with antibiotics were inserted. After two weeks, the external fixator was removed, and the pin sites were closed after debridement. One week later, the open reduction and internal fixation with locking compression plate and screws were done. Result: At 3 months after the internal fixation, the bone union was obtained with satisfactory alignment of the humerus. Conclusion: The severity of the soft tissue injury influences the fracture management plan. Further, the risk on lead toxicity should be considered.