• Title/Summary/Keyword: Guide system

Search Result 2,186, Processing Time 0.026 seconds

Development of 2.5 kW Class Propeller Type Micro Hydraulic Turbine (2.5 kW 급 프로펠러형 마이크로 수차 개발)

  • MA, SANG-BUM;KIM, SUNG;CHOI, YOUNG-SEOK;CHA, DONG-AN;KIM, JIN-HYUK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.31 no.3
    • /
    • pp.314-321
    • /
    • 2020
  • In this work, a preliminary design of an inlet guide vane and runner for developing a 2.5 kW hydraulic turbine was conducted by using computational fluid dynamic analysis. Three-dimensional Reynolds-averaged Navier-Stokes equations with shear stress transport turbulence model were used to analyze the fluid flow in the hydraulic turbine. The hexahedral grid system was used to construct computational domain, and the grid dependency test was performed to obtain the optimal grid system. Velocity triangle diagram considering the flow angles of the inlet guide vane and runner was analyzed to obtain a basic geometry of the inlet guide vane and runner. Through modification of the preliminary design, the hydraulic performances of the turbine have improved under overall drop conditions. Especially, the efficiency and power of the turbine increased by 0.95% and 1.45%, respectively, compared to those of the reference model.

An Indoor Localization and Guidance System for the Visually Impaired Person Based on Bluetooth 4.0 (시각 장애인을 위한 Bluetooth 4.0 기반의 실내 위치 추정 및 안내 시스템)

  • Bae, Sun-Young
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.8
    • /
    • pp.202-208
    • /
    • 2016
  • The scope of activities of the visually impaired is increasing. But they are not easy to visit the destination safely because the building was complicated and larger than ever. There is a guide system for visually impaired such as GPS and Audio alerts, Braille guide block, Acoustic signaller, etc. But they are not suitable for indoor because most of them are the outdoor guide system. Therefore, in this paper, I propose a system that provides guidance information to the visually impaired using Voice Technology, TTS (Text to Speech) and Haptic Technology, Beacon based on the wireless sensor networks. It informed the visually impaired of guidance information about destination such as distance, height, and obstacle to the destination using the generalized smart phone. The user could be received guide info about searches for the optimal route to the destination using the TTS technology and Haptic technology in test result of the proposed system.

A System for Medical Statistical Analysis Using Guide Maps and Interactive Visualization (가이드 맵과 인터랙티브 시각화를 이용한 의료 통계분석 시스템)

  • Lee Don-Soo;Choi Soo-Mi
    • Journal of Korea Multimedia Society
    • /
    • v.8 no.7
    • /
    • pp.1000-1011
    • /
    • 2005
  • This paper presents a system for medical statistical analysis that helps medical professionals analyze clinical data more easily and accurately. It is able to recommend proper methods according to the distribution of sample data, and provides guide maps composed of icons for the understanding of the process of analysis. Besides general statistical analysis, it includes commonly-used statistical methods for medical fields, such as survival analysis and methods for repetitive measurements. The results of analysis are interactively displayed by 3D glyph-based visualization with uncertainty.

  • PDF

NUMERICAL OPTIMIZATION OF TEMPERATURE DISTRIBUTION IN HRSG SYSTEM USING INLET GUIDE VANE (전치 가이드 베인 설치에 따른 열회수 보일러 입구 온도 최적화)

  • Lee, Soo-Yoon;Ahn, Joon;Shin, Seung-Won
    • Journal of computational fluids engineering
    • /
    • v.14 no.3
    • /
    • pp.1-8
    • /
    • 2009
  • Diverging channel from gas engine exit to the inlet section of Heat Recovery Steam Generator (HRSG) has been re-designed for 1 MW system. To improve the uniformity in velocity and temperature distribution of existing design(Case A and B), two additional test geometries have been chosen for the numerical simulation. At first, gas burner exit section has been centered to the inlet section of the boiler(Case C) and uniformity in velocity and temperature distribution has been improved considerably. Secondly, the diverging channel length can be further reduced to compact geometry with new guide vane design (Case D and E). Proposed design shows overall improvement in uniformity in velocity and temperature distribution compared to existing one.

Nanometric Positioning Over a One-Millimeter Stroke Using a Flexure Guide and Electromagnetic Linear Motor

  • Fukada, Shigeo;Nishimura, Kentaro
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.8 no.2
    • /
    • pp.49-53
    • /
    • 2007
  • In this study, we investigated experimentally the potential of a planer positioning mechanism with three degrees of freedom using a flexure guide and an electromagnetic linear motor. The goal was to produce a multi-axis positioning system with nanometric resolution over a 1-mm stroke. An $X-Y-\theta$ stage was designed based on previous results from a single-axis prototype and was constructed with a flexure guide mechanism and voice coil motor type linear actuators. We examined the necessity of a driving method and control system to ensure high resolution for multi-axis positioning. Experiments were conducted to evaluate the performance, and the results confirmed the mechanism's potential; fine point-to-point (PTP) positioning was achieved over a 1-mm stroke, with a resolution of 2 nm for translation in X-Y and 0.01 asec for yaw in $\theta$.

THE STUDY OF RELATIONSHIP BETWEEN SAGITTAL CONDYLAR GUIDE ANGLE AND INCISAL GUIDE ANGLE DURING MANDIBULAR PROTRUSION IN NORMAL KOREAN (정상 한국인의 하악 전방운동시 시상과로각과 절치로각에 관한 연구)

  • Kwon, Kung-Rock;Woo, Yi-Hyung;Choi, Dae-Gyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.27 no.2
    • /
    • pp.11-36
    • /
    • 1989
  • Mandibular movements are guided mainly by three determinants, namely the two posterior controls (the Temporomandibular joints) and the anterior control (the incisal guidance). The aim of this study was to evaluate the incisal guide angle in effort to reconcile a patient's condylar guide angle and incisu guide angle, to develop criteria for incisal guidance in clinical practice. 48 subjects (male 33, female 15) with intact intercuspation, without past history and symptoms of stomatognathic system, were selected for this study. All of the subjects had not anterior prostheses. The sagittal condylar guide angles and incisal guide angles were measured and estimated statistically by cephalogram and articulator (Whip-Mix 8500A). The results of this study were as follows: 1. Average of condylar guide angle was 43.33 degree by cephalogram, and was 35.18 degree by articulator. 95% confidence interval was from 40.43 to 46.23 degrees in cephalogram and was from 32.98 to 37.38 degrees in articulator. 2. Average of incisal guide angle was 51.51 degree by cephalogram, and was 44.11 degree by articulator. 95% confidence interval was from 49.12 to 54.95 degrees in cephalogram and was from 40.67 to 47.56 douses in articulator. 3. Difference between condylar and incisal guide angle was 8.18 degree by cephalogram, and was 8.94 degree by articulator. 95% confidence interval was from 4.61 to 11.74 degrees in cephalogram and was from 4.90 to 12.98 degrees in articulator. 4. In case of the incisal guide angle steeper than condylar guide angle, subjects were 69% (33 of 48) in cephatogram and 75% (36 of 48) in articulator. 5. By the multiple regression equation, condylar guide angle was more influenced by the anterior teeth. 6. When the mandible protrudes from the intercuspal position to the edge to edge position the incisal linear movement was 4.18mm (S.D.:1.30mm) and the condylar linear movement was 4.38mm (S.D.:1.26mm).

  • PDF

Rational treatment planning for implant treatment of the edentulous patients (완전무치악환자의 전악 임플란트 치료 계획 수립을 위한 체계적인 접근법)

  • Jeong-In Bae
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.32 no.2
    • /
    • pp.54-68
    • /
    • 2023
  • Treatment planning of edentulous patient with digital method is materialized by designing the surgical guide. When designing the surgical guide, we first implement the shape of the final prosthesis in the virtual space and then materialize the implantation plan based on this. However, it is challenging to make surgical guides for edentulous patients as their lack of both the reference for the arrangement of teeth and interocclusal relationship makes it hard to envision the shape of the final prosthesis. If there exists good partial or complete dentures or residual teeth, its teeth arrangement can be used as a reference for the virtual final prosthesis and the subsequent surgical guide. If such a reference is absent or unsatisfactory, a process of manufacturing a complete denture for diagnostic purposes and verifying it on patient's mouth is necessary and use it as a new reference for the virtual final prosthesis. But even if a surgical guide is produced through the reference from the thorough reflection of the virtual final prosthesis, when we use it in the surgical field, the intraoral condition of the patient may make the implants deviated from planned in the surgical guide. In the worst case, if the positioning of the surgical guide on the mouth is incorrect, it can lead to a catastrophic error that displaces all the implant, in which case the guided surgery would be much worse than the non-guided one. In this article, we will discuss how to obtain references of tooth arrangements in a timely manner and align or register them into a unified coordinate system in digital space, and also introduce how to transfer such an implantation plan from the virtual world into the patient's mouth of real world with minimum error. And lastly, I would like to express my opinion on the establishment of a rational and systematic protocol of guided surgery of the edentulous patients.

Invention of the Guide Catheter Irrigation Monitoring Device for Neuroendovascular Therapy

  • Ozkul, Ayca;Park, Jong-Hyun;Shin, Dong-Seung;Yilmaz, Ali;Kim, Bum-Tae
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.4
    • /
    • pp.471-474
    • /
    • 2017
  • Objective : The thromboembolic events during neuroendovascular therapy (NET) are the major complications of concern that can be occasionally fatal. The thrombotic occlusion of the guide catheter for NET is thought to be the risk of the thromboembolic events. We have developed an idea for inventing the monitoring system of the continuous irrigation through the guide catheter. We herein present a unique invention of the guide catheter irrigation monitoring device. Methods : We have developed ideas for preventing the thrombotic occlusion of the guide catheter. In order to design a convenient device working in the practical use, we have consulted and shared the ideas with the electrical engineers about putting the invention. Results : The guide catheter irrigation monitoring device (GCIMD) consisted of three parts of optical sensor, main body and electric adapter. In brief, the basic principles of working of the GCIMD are as follows. The optical sensor is attached to the dripping chamber of the line to irrigation solution. The main body had the small light and speaker to make an alarm sounds. The sensor monitors the dripping of flush solution. If the dripping stops more than three seconds, a warning alarm has been activated. So, the operating physicians can concentrate and check the guide catheter irrigation. After the use of the GCIMD, there was no major thromboembolic complication in conjunction with the thrombotic occlusion of the guide catheter in our institute. Conclusion : We have developed a brilliant invention of the GCIMD for NET.

The Effects of Injection Molding Conditions on Uniformity and Brightness of Light Guide Plate (도광판의 균일도 및 휘도에 사출성형조건이 미치는 영향)

  • Lee Sung-Hee;Kim S.W.;Lee H.S.;Kim J.D.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1609-1612
    • /
    • 2005
  • The effects of injection molding conditions on the uniformity and brightness of light guide plate(LGP) with micro-patterns were investigated in the present study. An injection molding system for stampers with mirco-pattern was designed and manufactured to perform experiment. Variations of injection molding speed, mold and melt temperature for LGP were considered in this work. Also, injection molding characteristics of LGP were investigated by numerical analysis using plastic injection molding commercial code. It was shown that injection molding conditions such as injection speed, melt temperature and mold temperature can have an effect on the uniformity and brightness of light guide plate.

  • PDF

Three-Dimensional Numerical Analysis on Recirculation Generated by Obstacles Around a Cooling Tower (냉각탑 주위 장애물에 의한 재순환 현상에 관한 3차원 수치해석)

  • Choi, Young-Ki
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.4
    • /
    • pp.225-234
    • /
    • 2009
  • The present study has been preformed to investigate the effect of obstacles around a cooling tower with air-guide to prevent recirculation. The external region as well as the cooling tower are included in the computational domain to analyze the flow phenomena around a cooling tower accurately. Three-dimensional analysis is performed using the finite volume method with non-orthogonal and unstructured grid system. The standard turbulence model is used to consider the turbulence effect. In order to investigate the recirculation phenomena, flow and temperature fields are calculated with the distance between cooling tower and obstacle, the allocated geometrical type and the air-guide. The moisture fraction rates decrease with increment of the distance between cooling tower and obstacle. The effect of air-guide to reduce the mean recirculation rate is obviously observed.