• Title/Summary/Keyword: Guide Fins

Search Result 3, Processing Time 0.022 seconds

Effect of Guide Fin Structures and Boundary Parameters on Thermal Performances of Heat Exchanger for Waste Heat Recovery Thermoelectric Generator (가이드 핀 구조와 경계 파라미터가 폐열 회수용 열전발전 열교환기의 열적 성능에 미치는 영향)

  • Garud, Kunal Sandip;Seo, Jae-Hyeong;Lee, Moo-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.3
    • /
    • pp.30-35
    • /
    • 2021
  • The present study examined the effects of various guide fin structures and boundary parameters on the thermal performance of heat exchangers used in heat recovery thermoelectric generators. The heat transfer rate and pressure drop of the heat exchangers without fins, with circular fins, with triangular fins, and with combined circular and triangular fins were simulated numerically using ANSYS 19.1 commercial code to confirm the effect of the guide fin structures. The heat transfer rate of the heat exchanger with combined fins was 27.0%, 5.2%, and 1.5% higher than those without fins, with circular fins, and with triangular fins, respectively. The pressure drop characteristic of the heat exchanger with the combined fins was 28.3% higher than that without fins but 9.2% and 10.5% lower than those with circular fins and with triangular fins, respectively. The heat exchanger with combined fins as the optimal model showed the highest heat transfer rate of 5664.9 W and pressure drop of 1454.02 Pa for highest hot gas temperature, maximum flow rates of hot gas and coolant, and lowest coolant temperature.

Effects of a Guide Fin Blade on the Flow Characteristics in a Ventilating Axial Fan (환기용 축류팬의 가이드핀 블레이드 형상변화에 따른 유동특성에 관한 연구)

  • Park, Hong-Kwang;Lee, Jee-Keun;Rho, Byung-Joon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.12
    • /
    • pp.874-882
    • /
    • 2007
  • The effects of a guide fin blade on the flow characteristics in a ventilating axial fan were investigated experimentally. The guide fins were setup onto the pressure surface of the blade, and their effects on the flowrate were evaluated. Two types of the guide fin blade were designed. One is the stem fin blade, and the other is the radial fin blade. The stem fin is designed normal to the circumference of a circle, and the radial fin is designed along the circumference of a circle. The results from the guide fin blade fans are compared with that of the blade without guide fins. The position and the geometry of the radial fin setting up on the blade have an effect on the increase of flowrate with the minor sacrifice of rotational speed of the blades. The radial fin positioning at 0.84 times blade diameter shows highest performance in the flowrate. The increase of the blade weight resulting from applying the guide fins shows minor effect on the variation of rotational speed of the blades.

Heat transfer enhancement of finless TEFC induction motor frame by installing guide vanes (핀이 없는 전폐형 유도전동기 프레임의 정익 설치에 의한 열전달 향상)

  • Jeon, Chang-Seong;Go, Sang-Geun;Yun, Myeong-Geun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.6
    • /
    • pp.849-859
    • /
    • 1998
  • The heat generated in an induction motor is mostly dissipated through the frame. The study on the heat transfer characteristics of a newly manufactured finless TEFC(Totally Enclosed Fan Cooled) induction motor showed/that it had an unsuitable structure in view of the heat transfer. The angle of the cooling air flow was very large and the ribs disturbed the air flow and partially generated the wake region on the frame. In the wake region the temperature was very high. Thus the heat transfer coefficients were lower than those of the frame with fins. Also was investigated the heat transfer characteristics of the motor frame by installing various guide vanes in the fan-side end cap. An optimum heat transfer case was found and the average heat transfer coefficient of the frame was 70% higher and the average coil temperature measured by the resistance method was 9 deg. C lower than that of the frame which had no guide vanes.