• 제목/요약/키워드: Guide

검색결과 7,397건 처리시간 0.035초

재귀반사 원리를 이용한 점등이미지 향상 LIGHT GUIDE 개발 (Development of the Light Guide Lamp for Lighting Image Enhancement Using Retro Reflection Principle)

  • 김형선;최성욱;진건수
    • 자동차안전학회지
    • /
    • 제11권4호
    • /
    • pp.16-21
    • /
    • 2019
  • In recent years, most automobile manufacturers have been using slim light source images to imprint their own brand image and identity. A light guide type lamp is widely used for making these kinds of a slim light source image. A light guide lamp means using a light emitting diode light source at one end of a long cylindrical pipe. The light from the light emitting diode source moves through the pipe by total reflection principle. Moving light is sent forward by various optic structures which is applied in the cylindrical pipe. However, the light guide lamp has a problem that the image of the light differs depending on the viewing direction, and in some cases there is dark section. It means light guide has low quality about lighting image. In this paper, trying to improve the fundamental problems of the light guide mentioned above by using various triz methods. Through functional modeling, estimating the factors affecting the light in the light guide lamp and make various ideas to improve the lighting image using the chain effect cause analysis, function oriented search scientific database techniques. Using these kinds of various TRIZ methods, finally find solutions that can improve the brightness and lighting uniformity of the light guide lamp. The ideas obtained in this paper were applied to actual vehicle development, and several patents achievements were obtained. In conclusion, it is proved that TRIZ method is useful for making ideas in actual automobile industrial field and is also a useful method for acquiring patent.

정상 한국인의 하악 전방운동시 시상과로각과 절치로각에 관한 연구 (THE STUDY OF RELATIONSHIP BETWEEN SAGITTAL CONDYLAR GUIDE ANGLE AND INCISAL GUIDE ANGLE DURING MANDIBULAR PROTRUSION IN NORMAL KOREAN)

  • 권긍록;우이형;최대균
    • 대한치과보철학회지
    • /
    • 제27권2호
    • /
    • pp.11-36
    • /
    • 1989
  • Mandibular movements are guided mainly by three determinants, namely the two posterior controls (the Temporomandibular joints) and the anterior control (the incisal guidance). The aim of this study was to evaluate the incisal guide angle in effort to reconcile a patient's condylar guide angle and incisu guide angle, to develop criteria for incisal guidance in clinical practice. 48 subjects (male 33, female 15) with intact intercuspation, without past history and symptoms of stomatognathic system, were selected for this study. All of the subjects had not anterior prostheses. The sagittal condylar guide angles and incisal guide angles were measured and estimated statistically by cephalogram and articulator (Whip-Mix 8500A). The results of this study were as follows: 1. Average of condylar guide angle was 43.33 degree by cephalogram, and was 35.18 degree by articulator. 95% confidence interval was from 40.43 to 46.23 degrees in cephalogram and was from 32.98 to 37.38 degrees in articulator. 2. Average of incisal guide angle was 51.51 degree by cephalogram, and was 44.11 degree by articulator. 95% confidence interval was from 49.12 to 54.95 degrees in cephalogram and was from 40.67 to 47.56 douses in articulator. 3. Difference between condylar and incisal guide angle was 8.18 degree by cephalogram, and was 8.94 degree by articulator. 95% confidence interval was from 4.61 to 11.74 degrees in cephalogram and was from 4.90 to 12.98 degrees in articulator. 4. In case of the incisal guide angle steeper than condylar guide angle, subjects were 69% (33 of 48) in cephatogram and 75% (36 of 48) in articulator. 5. By the multiple regression equation, condylar guide angle was more influenced by the anterior teeth. 6. When the mandible protrudes from the intercuspal position to the edge to edge position the incisal linear movement was 4.18mm (S.D.:1.30mm) and the condylar linear movement was 4.38mm (S.D.:1.26mm).

  • PDF

Milling Characteristics of Cutting-Type Rice Milling Machine - According to Cutting Roller Induced Guide Angles -

  • Cho, Byeong-Hyo;Kang, Tae-Hwan;Lee, Dong-Il;Won, Jin-Ho;Lee, Hee-Sook;Han, Chung-Su
    • Journal of Biosystems Engineering
    • /
    • 제42권2호
    • /
    • pp.112-116
    • /
    • 2017
  • Purpose: The purpose of this study was to analyze the milling characteristics of white rice depending on the guide angles of the cutting roller's induced guide, as well as to verify optimum milling conditions for the cutting-type milling machine. Methods: Brown rice, which was produced in Cheongju-si, Chungcheongbuk-do, Republic of Korea, in 2014, was used as the experimental material. The milling characteristics of white rice were measured under six different guide angle levels of the cutting roller, which were none, $0^{\circ}$, $5^{\circ}$, $10^{\circ}$, $15^{\circ}$, and $20^{\circ}$. The quantity of brown rice for each experiment was 500 kg, and the milling characteristics were measured according to the whiteness, rice temperature, cracked rice ratio, broken rice ratio, and energy consumption. Results: The whiteness of white rice maintained a uniform level, indicating at range of $38{\pm}0.5$, regardless of the cutting roller guide angles under all conditions. The rice temperature rise during milling was found to be rather low, at $13.9^{\circ}C$ and $13.6^{\circ}C$ at $10^{\circ}$ and $15^{\circ}$ guide angles, respectively. The cracked rice ratio after milling was 18.67%-19.47%, and the broken rice ratio was 0.68% at a $10^{\circ}$ guide angle, which is the lowest in comparison to other guide angles. Energy consumption was lower when the guide was used compared to that with-out the use of the guide. The energy consumption tended to increase as the cutting roller guide angle increased. Conclusions: From the above results, we conclude that the cutting roller guide angles of $0^{\circ}$ and $10^{\circ}$ are suitable for producing high quality rice during milling with a cutting-type milling machine.

완전무치악환자의 전악 임플란트 치료 계획 수립을 위한 체계적인 접근법 (Rational treatment planning for implant treatment of the edentulous patients)

  • 배정인
    • 대한심미치과학회지
    • /
    • 제32권2호
    • /
    • pp.54-68
    • /
    • 2023
  • 디지털 방법을 사용한 무치악의 임플란트 치료계획은 surgical guide design으로 구체화된다. Surgical guide를 제작할 때, 우리는 먼저 최종 보철의 형태를 가상공간에 구현한 후 이를 바탕으로 식립 계획을 구체화하게 된다. 그러나 완전무치악 환자는 치아배열의 기준이 없고 악간관계가 정립되어 있지 않아 최종 보철의 형태를 짐작하기 어려워 surgical guide를 만드는 데 어려움이 있다. 이때 기존의 만족스러운 총의치나 부분의치, 잔존치 등이 존재한다면 그 치아배열이 가상적인 최종 보철의 reference가 될 수 있다. 만약 이러한 reference가 부재하거나 만족스럽지 못하다면, 진단용 목적으로 총의치를 제작하되 이를 구내에서 검증하는 과정이 필요하다. 이러한 과정을 통해 surgical guide를 제작할지라도 구내 상황에 따라 implant의 위치가 계획한 것과 다르게 식립될 수 있으며, 만약 guide의 positioning이 잘못된다면 그 오차는 모든 implant의 위치를 변위시킬 수 있으므로 guide 수술이 오히려 재앙으로 다가올 수 있다. 본 기고에서는 치아 배열의 reference가 될 수 있는 자료들을 적절한 시기에 채득하여 이를 디지털 공간에 이전 및 통일된 좌표계로 정렬하는 방법에 대해 논의하고, 또한 이렇게 수립된 식립계획을 현실의 구강에 적은 오차로 이전 및 정렬하는 방법에 대해 소개하여 일관적이고 체계적인 무치악 가이드 디자인의 프로토콜 정립에 대해 의견 개진하려 한다.

안내궤도를 이용한 고무차륜 경량전철 AGT 궤도부설공법 (Method for Constructing a Railway by using a Guide-way for a Rubber-wheeled automated Transit System)

  • 강남훈;이안호;이일화;김창환
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.1793-1798
    • /
    • 2011
  • The railway structure for a rubber-wheeled automated guide-way transit system consists of a driveway and a guide-way. The most important factor of this system is the driveway and the guide-way aligned with each other, especially for curves and inclines section. The conventional construction method caused many problems such as discordancy by constructing the driveway before constructing the guide-way. Therefore, in this paper we introduce a new method of constructing a railway for a rubber-wheeled light rail vehicle; the new method of constructing the guide-way beforehand as a preceding process. The new method for AGT railway system can simplify the construction process and thus the construction costs may be reduced. It should also improve the driving performance and the comfortability in operating of a light rail vehicle.

  • PDF

Designing an Integrated Online-guide for Overseas Applicants Seeking to Teach English in Korea: Focus on Job and Visa Application

  • Ryu, JaeYoul
    • International Journal of Contents
    • /
    • 제10권4호
    • /
    • pp.83-89
    • /
    • 2014
  • This study suggests an effective online guide for foreign teachers who want to teach English in Korean schools. When designing this guide for overseas applicants, there should be a consistent analysis to reflect the process of the system. Thus, this paper provides an analysis and results for an integrated online guide to increase the efficiency based on the pedagogical framework for analysis of the 'ADDIE' model (Analyze, Design, Development, Implementation, and Evaluation). The number of job applicants who wish to teach English in Korea is growing rapidly because Korea is one of the fastest growing economies in the world and the 'Korean Wave' has especially been experiencing significant changes with the development of social network services and digital technologies. As a result, overseas applicants' expectations regarding Korea when they are seeking information and applying is very high, but the aspects of the procedure provided by the government are somewhat disappointing. The paper presents customer needs and specific recommendation for each step of the application process to improve the guide's effectiveness.

Feasibility Study of Diffusion Film for the Light Guide of Gamma Ray Imaging System

  • Cha, Hyemi;Min, Eungi;Lee, Kisung;Jung, Young-Jun;Lee, Hakjae
    • IEIE Transactions on Smart Processing and Computing
    • /
    • 제6권2호
    • /
    • pp.124-128
    • /
    • 2017
  • A light guide improves the spatial resolution of a gamma ray imaging system by diffusing the scintillation light. Similarly, light diffusion film, which has been applied to flat-panel-display engineering, spreads the light from the light guide panel. In this study, we adopted light diffusion film for the light guide of a gamma ray imaging system, and evaluated its diffusion characteristics. We compared the light diffusion performance of the film to an ordinary acrylic plate. As a result, the diffusion film widely spreads scintillation light. As for the thickness of the light guide, we acquired more distinct images with three films overlapped than with an acrylic plate. We expect light diffusion film to be a promising candidate for light guides in gamma ray imaging systems.

CFD Analysis for Aligned and Misaligned Guide Vane Torque Prediction and Validation with Experimental Data

  • Devals, Christophe;Vu, Thi C.;Guibault, Francois
    • International Journal of Fluid Machinery and Systems
    • /
    • 제8권3호
    • /
    • pp.132-141
    • /
    • 2015
  • This paper presents a CFD-based methodology for the prediction of guide vane torque in hydraulic turbine distributor for aligned and misaligned configurations. A misaligned or desynchronized configuration occurs when the opening angle of one guide vane differs from the opening angle of all other guide vanes, which may lead to a torque increase on neighbouring guide vanes. A fully automated numerical procedure is presented, that automates computations for a complete range of operation of a 2D or 3D distributor. Results are validated against laboratory measurements.

핵연료집합체 안내관의 하중집중계수 해석 (Load Concentration Factor Analysis of Fuel Assembly Guide Thimble)

  • 이영신;전상윤
    • 한국정밀공학회지
    • /
    • 제22권3호
    • /
    • pp.93-100
    • /
    • 2005
  • The top and bottom nozzles of PWR fuel assembly are connected by guide thimbles and an instrumentation tube that are connected with spacer grids. The fuel rods are inserted into the each cell of spacer grids. The loads acting on the fuel assembly are transmitted to the guide thimbles through the flow plate of top nozzle The axial loads applied to the fuel assembly are not equally distributed among the guide thimble due to the geometry of the top nozzle flow plate and spacer grid. In this study, the load concentration factors for the $17\times17$ fuel assembly were calculated. The analytical model fur the calculation of the load concentration factor of top nozzle flow plate was developed using ANSYS 5.6. The finite element analyses were performed using the model composed of top nozzle, guide thimble, and spacer grid. And, the analysis results were compared with the test results.

입구 안내익 영향으로 인한 원심 압축기 불안정성 연구 (Experimental Study on the Effect of Inlet Guide Vane of Instabilities of a Centrifugal Compressor)

  • 임병준;차봉준
    • 한국유체기계학회 논문집
    • /
    • 제7권3호
    • /
    • pp.23-31
    • /
    • 2004
  • An experimental study on the performance and instability development characteristics of a centrifugal compressor equipped with an adjustable inlet guide vane has been performed with varying guide vane angles. The test was conducted at the design speed of 20,800 rpm for 6 guide vane angles : $-30^{\circ},\;-20^{\circ},\;10^{\circ},\;0^{\circ},\;10^{\circ},\;20^{\circ},\;30^{\circ}$. Unsteady pressures were measured using high-frequency pressure transducers at the inducer to investigate the instability phenomena such as rotating stall and surge inside the compressor. From the unsteady measurements, it is found that the transient process from rotating stall to surge was mainly affected by inlet guide vane angles. The results of the present study can be applied to the instability control of the centrifugal compressors using a adjustable inlet guide vane.