• Title/Summary/Keyword: Guidance Device

Search Result 153, Processing Time 0.021 seconds

Clinical Application of Stent-graft in Thoracic Aortic Diseases (흉부 대동맥 질환에서 스텐트-그라프트의 임상적 적용)

  • Kim, Kyung-Hwan;Lee, Cheul;Chang, Ji-Min;Chung, Jin-Wook;Ahn, Hyuk;Park, Jae-Hyung
    • Journal of Chest Surgery
    • /
    • v.34 no.9
    • /
    • pp.698-703
    • /
    • 2001
  • Background: Endovascular stent-graft insertion in aortic diseases is now generally accepted as an attractive alternative treatment modality. We reviewed our clinical experiences of endovascular stent-graft insertion in thoracic aorta. Material and Method: Since 1995, we performed 8 cases of endovasclar stent-graft insertion. Preoperative diagnoses were aortic aneurysms in 4, traumatic aortic ruptures in 3, and ruptured aortic pseudoaneurysm in 1. All procedures were performed in angiography room with the guidance of fluoroscopy. The stent-graft device is a custom-made 0.35mm thickness Z-shaped stainless steel wires, intertwined with each other using polypropylene suture ligation. It is covered with expanded Dacron vascular graft. Result: All procedures were performed successfully. Follow-up studies revealed 2 minimal perigraft leakages. There was no significant leakage or graft migration. 2 patients expired due to multiple organ failure and fungal sepsis. Other survivors(6) are doing well. Conclusion: Endovascular stent-graft insertion is relatively saft and effective treatment modality in the managment of various types of aortic diseases. In may be an effective alternative in aortic diseases of great surgical risk.

  • PDF

Combined Radiotherapy and Hyperthermia for Nonresectable Hepatocellular Carcinoma (절제 불가능한 원발성 간암의 온열 및 방사선 병용 요법)

  • Seong Jin Sil;Juhn Juhn Kyu;Suh Chang Ok;Kim Gwi Eon;Han Kwang Hyub;Lee Sang In;Roh Jae Kyung;Choi Heung Jai;Kim Byung Soo
    • Radiation Oncology Journal
    • /
    • v.7 no.2
    • /
    • pp.247-257
    • /
    • 1989
  • Thirty patients with nonresectable hepatocellular carcinoma (HCC) due to either locally advanced lesion or association with liver cirrhosis, treated with combined radiotherapy and hyperthermia between April 1988 and July 1988, at Dept. of Radiation Oncology, Yonsei university College of medicine, were analysed. External radiotherapy of a total dose of 3060cGy/3.5 wks was given. Hyperthermia was given twice a week with a total of 6 treatment sessions using 8MHz radiofrequency capacitive type heating device, i.e., Thermotron RF-8 and Cancermia. In all cases hyperthermia was given within 30 minutes after radiotherapy for 30~60min. Temperature was measured by inserting thermocouple into the tumor mass under the ultrasonographic guidance only for those who had not bleeding tendency. As a result, partial response (PR) was achieved in 12 patients (40%), and symptomatic improvement was observed in 22 patients (78.6%) among 28 patients who had suffered from abdominal pain. The most significant factor affecting the tumor response rate was the type of tumor (single massive: 10/14, 71.4%; diffuse infiltrative: 2/10, 20%; multinodular:0/6, 0%; p<0.005). There were not any significant side effects relating to combined treatment. The overall 1 year survival rate was 34%, with 50% in the PR group and 22% in the no response group (NR), respectively. Median survival was 6.5 months and longer for those of PR than of NR (11 mos. vs 5, p<0.05). In conclusion, combined radiotherapy and hyperthermia appeared to be effective in local control and symptomatic palliation of HCC. Further study including a larger number of the patients to confirm its effect in survival and detrimental side effect should be urged.

  • PDF

Development of a smart cane concept for guiding the visually impaired - focused on design thinking learning practices for students - (시각장애인을 위한 길 안내용 스마트 지팡이 콘셉트 개발)

  • Park, Hae Rim;Lee, Min Sun;Yang, Ho Jung
    • Journal of Service Research and Studies
    • /
    • v.13 no.1
    • /
    • pp.186-200
    • /
    • 2023
  • This study aims to improve the usability of the white cane, which is walking equipment that most local visually impaired people use and carry when going out, and to contribute to the prevention of safety accidents and the walking rights of visually impaired people by providing improvement and resolution measures for the problems identified. Also, this study is a study on the visually impaired, primarily targeting the 1st to 2nd degree visually impaired people, who cannot go out on their own without walking equipment such as a white cane, corresponding to 20% among approximately 250,000 blind and low vision people in the Korean population. In the study process, the concept has been developed from the user's point of view in order that the white cane becomes a real help in the walking step of the visually impaired and the improvement of usability of the white cane, the main walking equipment for the visually impaired, are done by problem identification through the Double Diamond Model of Design Thinking (Empathize → Define → Ideate → Prototype → Test (verify)). As a result of the investigation in the process of Empathy, a total of five issues was synthesized, including an increase in the proportion of the visually impaired people, an insufficient workforce situation to help all the visually impaired, an improvement and advancement of assistive devices essential for the visually impaired, problems of damage, illegal occupation, demolition, maintenance about braille blocks, making braille block paradigms for the visually impaired and for everyone. In Ideate and Prototype steps, situations derived from brainstorming were grouped and the relationship were made through the KJ method, and specific situations and major causes were organized to establish the direction of the concept. The derived solutions and major functions are defined in four categories, and representative situations requiring solutions and major functions are organized into two user scenarios. Ideas were visualized by arranging the virtual Persona and Customer Journey Map according to the situation and producing a prototype through 3D modeling. Finally, in the evaluation, the final concept derived is a device such a smart cane for guidance for the visually impaired as ① a smart cane emphasizing portability + ② compatibility with other electronic devices + ③ a product with safety and convenience.