• Title/Summary/Keyword: Group differences

Search Result 14,060, Processing Time 0.051 seconds

Warner-Bratzler Shear Force, Sarcomere Length, Total Collagen Contents and Sensory Characteristics of Hanwoo Beef (Korean Native Cattle) Quality Grade (한우육의 육질등급에 따른 부위별 전단력, 근절길이, 콜라겐의 함량 및 관능 특성)

  • Lee, Yeon-Jung;Kim, Cheon-Jei;Park, Beom-Young;Seong, Pil-Nam;Kim, Jin-Hyong;Kang, Guen-Ho;Kim, Dong-Hun;Cho, Soo-Hyun
    • Food Science of Animal Resources
    • /
    • v.29 no.6
    • /
    • pp.726-735
    • /
    • 2009
  • This study was conducted to investigate the Warner-Bratzler shear force (WBS), sarcomere length, total collagen contents and consumer tests of different cuts of Hanwoo beef based on quality grade. Five cuts [Cheggt (striploin), Dngsim (loin), Moksim (chuck roll), Udoon (top round), Yanggi (brisket)] were obtained from Hanwoo beef (bulls and steers, 24-30 months old) and grouped by their quality grades ($1^{++}$, $1^+$, 1, 2 and 3). The WBS values of chuck cut in $1^{++}$, $1^+$ and 1 quality grade groups were 5.47 (kg/0.5 $inch^2$), 5.46 (kg/0.5 $inch^2$) and 6.54 (kg/0.5 $inch^2$), respectively, which were significantly lower than those of chuck in quality grade 3, which was 8.41 (kg/0.5 $inch^2$) (p<0.05). The sarcomere length of the quality grade groups were significantly longer for brisket (3.72 ${\mu}m$) of $1^{++}$ quality grade than for that of 3 quality grade brisket (p<0.05). Brisket of $1^{++}$ and 2 quality grade had significantly greater sarcomere lengths than strip loin and top round in the same quality grade (p<0.05). The total collagen contents of strip loins in the $1^{++}$, $1^+$, and 1 quality grade groups (1.17, 1.18 and 1.14 g/100 g, respectively) were significantly lower than those of the 3 quality grade group (1.63 g/100 g) (p<0.05). The overall sensory scores of tenderness and juiciness for the five cuts of $1^{++}$ quality grade were significantly higher than those of the other quality grade (p<0.05). Among the five cuts, loin had the highest tenderness and juiciness scores (p<0.05), whereas top round had the lowest tenderness and juiciness scores (p<0.05). Overall, there were significant differences in the WBS and sensory properties among quality grades and cuts (p<0.05). However, the sarcomere length and total collagen contents of chuck roll, top round and loin did not differ among quality grades.

On the Influence Each Other Between the Monks in the Buddhist Temples and the Society in Towns or Villages (중국(中國) 지방사회(地方社會)와 불교사원(佛敎寺院) 그리고 승인(僧人)의 상호(相互) 영향(影響)에 관한 일고(一考))

  • Yan, Yao zhong
    • Korean Journal of Heritage: History & Science
    • /
    • v.45 no.3
    • /
    • pp.60-79
    • /
    • 2012
  • Environment of ancient Chinese Buddhist temple can be classified to three types such as regional society(鄕村), famous mountain(名山), and urban areas(都市). This made differences in environment where a temple existed and in turn, affected development of Buddhism. And this made another type in relationship between Buddhist temple and a society. This study explains influences which regional society gave on not only Buddhist temple and a monk but also existence and development of Buddhism. When temples are placed in different environmental position, that is, urban areas and regional society, among a social structure, they eventually should adapt to a different society externally and internally. As told in above, ancient Chinese Buddhist temple was located in regional society, famous mountain, and urban areas. Since Eastern Jin and Sixteen Kingdoms, as number of temple much increased, and temples and monks were concentrated on famous mountain, temples in famous mountains and urban areas had developed showing similar aspects each other. But because temples in regional society were influenced a little differently, this study focused on the point. There are four kinds of influences between temples and monks in regional areas. Monks in regional areas had a comparatively close relationship with a society because they came from same area or surrounding areas. Therefore,powers of regional areas restrict influences made by monk group in temple. Second, temples in regional areas shared their joys and sorrows depending on regional economy. Temples in regional areas became a public place for the society and often a market place. In fact, construction and existence of a temple originally became a driving force in regional economy. This is because construction of temple needs artisans and materials and some temples had visitors and included market economy like consumption of incense and candles, though the economic size was large or small. And when regional areas experienced natural disaster or man-made disaster or had poor harvest or economy was in depression, monks left temples and then, temples themselves could not exist. Third, the relationship between temples in regional areas and Buddhists was distinguished from the temples in urban areas and famous mountains. This is because temples in China were places where monks practiced and at the same time, places where general Buddhists worshipped. So there were always a number of Buddhists around the temples. Forth, Buddhism in resional areas was connected to regional Folk beliefs. As a result, Buddhism was spread across the nation, worship with local color often was changed to Buddhist belief or was tinged with Buddhism. While temples in regional areas maintained a close relationship with regional society.they were influenced by the region or gave influences. As a representative example, temples in regional areas showed model behaviors instead of roles of facilities related to various cultures with comparatively advanced level - for example, school, hospital etc. The temples highly affected funerary rites in regional areas. Chinese tombs were mainlymade in regional areas. After death,people living in urban areas were buried in hometown or at least, they were buried in suburbs not urban areas. Temples in regional areas generally participated in funerary rites. Above shows that though most of famous Buddhist temples were located in urban areas not in famous mountains,majority of temples were located in vast regional areas. Through mutual interaction between temples and regional society, the temples in the regional areas were related to Chinese people of over 90% and regional areas became the most important foundation for Buddhism in China. Mutual influences between temples in regional areas and the general public in regions were omnidirectional and spreaded to every aspects of social life in small or large degree. Thus Tombs in temple were widely spreaded across regional areas over time and space. This is enough to explain a close relationship between Buddhist temples and rural society in ancient China.

A Deep Learning Based Approach to Recognizing Accompanying Status of Smartphone Users Using Multimodal Data (스마트폰 다종 데이터를 활용한 딥러닝 기반의 사용자 동행 상태 인식)

  • Kim, Kilho;Choi, Sangwoo;Chae, Moon-jung;Park, Heewoong;Lee, Jaehong;Park, Jonghun
    • Journal of Intelligence and Information Systems
    • /
    • v.25 no.1
    • /
    • pp.163-177
    • /
    • 2019
  • As smartphones are getting widely used, human activity recognition (HAR) tasks for recognizing personal activities of smartphone users with multimodal data have been actively studied recently. The research area is expanding from the recognition of the simple body movement of an individual user to the recognition of low-level behavior and high-level behavior. However, HAR tasks for recognizing interaction behavior with other people, such as whether the user is accompanying or communicating with someone else, have gotten less attention so far. And previous research for recognizing interaction behavior has usually depended on audio, Bluetooth, and Wi-Fi sensors, which are vulnerable to privacy issues and require much time to collect enough data. Whereas physical sensors including accelerometer, magnetic field and gyroscope sensors are less vulnerable to privacy issues and can collect a large amount of data within a short time. In this paper, a method for detecting accompanying status based on deep learning model by only using multimodal physical sensor data, such as an accelerometer, magnetic field and gyroscope, was proposed. The accompanying status was defined as a redefinition of a part of the user interaction behavior, including whether the user is accompanying with an acquaintance at a close distance and the user is actively communicating with the acquaintance. A framework based on convolutional neural networks (CNN) and long short-term memory (LSTM) recurrent networks for classifying accompanying and conversation was proposed. First, a data preprocessing method which consists of time synchronization of multimodal data from different physical sensors, data normalization and sequence data generation was introduced. We applied the nearest interpolation to synchronize the time of collected data from different sensors. Normalization was performed for each x, y, z axis value of the sensor data, and the sequence data was generated according to the sliding window method. Then, the sequence data became the input for CNN, where feature maps representing local dependencies of the original sequence are extracted. The CNN consisted of 3 convolutional layers and did not have a pooling layer to maintain the temporal information of the sequence data. Next, LSTM recurrent networks received the feature maps, learned long-term dependencies from them and extracted features. The LSTM recurrent networks consisted of two layers, each with 128 cells. Finally, the extracted features were used for classification by softmax classifier. The loss function of the model was cross entropy function and the weights of the model were randomly initialized on a normal distribution with an average of 0 and a standard deviation of 0.1. The model was trained using adaptive moment estimation (ADAM) optimization algorithm and the mini batch size was set to 128. We applied dropout to input values of the LSTM recurrent networks to prevent overfitting. The initial learning rate was set to 0.001, and it decreased exponentially by 0.99 at the end of each epoch training. An Android smartphone application was developed and released to collect data. We collected smartphone data for a total of 18 subjects. Using the data, the model classified accompanying and conversation by 98.74% and 98.83% accuracy each. Both the F1 score and accuracy of the model were higher than the F1 score and accuracy of the majority vote classifier, support vector machine, and deep recurrent neural network. In the future research, we will focus on more rigorous multimodal sensor data synchronization methods that minimize the time stamp differences. In addition, we will further study transfer learning method that enables transfer of trained models tailored to the training data to the evaluation data that follows a different distribution. It is expected that a model capable of exhibiting robust recognition performance against changes in data that is not considered in the model learning stage will be obtained.

Influence of Microcrack on Brazilian Tensile Strength of Jurassic Granite in Hapcheon (미세균열이 합천지역 쥬라기 화강암의 압열인장강도에 미치는 영향)

  • Park, Deok-Won;Kim, Kyeong-Su
    • Korean Journal of Mineralogy and Petrology
    • /
    • v.34 no.1
    • /
    • pp.41-56
    • /
    • 2021
  • The characteristics of the six rock cleavages(R1~H2) in Jurassic Hapcheon granite were analyzed using the distribution of ① microcrack lengths(N=230), ② microcrack spacings(N=150) and ③ Brazilian tensile strengths(N=30). The 18 cumulative graphs for these three factors measured in the directions parallel to the six rock cleavages were mutually contrasted. The main results of the analysis are summarized as follows. First, the frequency ratio(%) of Brazilian tensile strength values(kg/㎠) divided into nine class intervals increases in the order of 60~70(3.3) < 140~150(6.7) < 100~110·110~120(10.0) < 90~100(13.3) < 80~90(16.7) < 120~130·130~140(20.0). The distribution curve of strength according to the frequency of each class interval shows a bimodal distribution. Second, the graphs for the length, spacing and tensile strength were arranged in the order of H2 < H1 < G2 < G1 < R2 < R1. Exponent difference(λS-λL, Δλ) between the two graphs for the spacing and length increases in the order of H2(-1.59) < H1(-0.02) < G2(0.25) < G1(0.63) < R2(1.59) < R1(1.96)(2 < 1). From the related chart, the six graphs for the tensile strength move gradually to the left direction with the increase of the above exponent difference. The negative slope(a) of the graphs for the tensile strength, suggesting a degree of uniformity of the texture, increases in the order of H((H1+H2)/2, 0.116) < G((G1+G2)/2, 0.125) < R((R1+R2)/2, 0.191). Third, the order of arrangement between the two graphs for the two directions that make up each rock cleavage(R1·R2(R), G1·G2(G), H1·H2(H)) were compared. The order of arrangement of the two graphs for the length and spacing is reverse order with each other. The two graphs for the spacing and tensile strength is mutually consistent in the order of arrangement. The exponent differences(ΔλL and ΔλS) for the length and spacing increase in the order of rift(R, -0.08) < grain(G, 0.14) < hardway(H, 0.75) and hardway(H, 0.16) < grain(G, 0.23) < rift(R, 0.45), respectively. Fourth, the general chart for the six graphs showing the distribution characteristics of the microcrack lengths, microcrack spacings and Brazilian tensile strengths were made. According to the range of length, the six graphs show orders of G2 < H2 < H1 < R2 < G1 < R1(< 7 mm) and G2 < H1 < H2 < R2 < G1 < R1(≦2.38 mm). The six graphs for the spacing intersect each other by forming a bottleneck near the point corresponding to the cumulative frequency of 12 and the spacing of 0.53 mm. Fifth, the six values of each parameter representing the six rock cleavages were arranged in the order of increasing and decreasing. Among the 8 parameters related to the length, the total length(Lt) and the graph(≦2.38 mm) are mutually congruent in order of arrangement. Among the 7 parameters related to the spacing, the frequency of spacing(N), the mean spacing(Sm) and the graph (≦5 mm) are mutually consistent in order of arrangement. In terms of order of arrangement, the values of the above three parameters for the spacing are consistent with the maximum tensile strengths belonging to group E. As shown in Table 8, the order of arrangement of these parameter values is useful for prior recognition of the six rock cleavages and the three quarrying planes.

A Study on the Effect of Water Soluble Extractive upon Physical Properties of Wood (수용성(水溶性) 추출물(抽出物)이 목재(木材)의 물리적(物理的) 성질(性質)에 미치는 영향(影響))

  • Shim, Chong-Supp
    • Journal of the Korean Wood Science and Technology
    • /
    • v.10 no.3
    • /
    • pp.13-44
    • /
    • 1982
  • 1. Since long time ago, it has been talked about that soaking wood into water for a long time would be profitable for the decreasing of defects such as checking, cupping and bow due to the undue-shrinking and swelling. There are, however, no any actual data providing this fact definitly, although there are some guesses that water soluble extractives might effect on this problem. On the other hand, this is a few work which has been done about the effect of water soluble extractives upon the some physical properties of wood and that it might be related to the above mentioned problem. If man does account for that whether soaking wood into water for a long time would be profitable for the decreasing of defects due to the undue-shrinking and swelling in comparison with unsoaking wood or not, it may bring a great contribution on the reasonable uses of wood. To account for the effect of water soluble extractives upon physical properties of wood, this study has been made at the wood technology laboratory, School of Forestry, Yale university, under competent guidance of Dr. F. F. Wangaard, with the following three different species which had been provided at the same laboratory. 1. Pinus strobus 2. Quercus borealis 3. Hymenaea courbaril 2. The physical properties investigated in this study are as follows. a. Equilibrium moisture content at different relative humidity conditions. b. Shrinkage value from gre condition to different relative humidity conditions and oven dry condition. c. Swelling value from oven dry condition to different relative humidity conditions. d. Specific gravity 3. In order to investigate the effect of water soluble extractives upon physical properties of wood, the experiment has been carried out with two differently treated specimens, that is, one has been treated into water and the other into sugar solution, and with controlled specimens. 4. The quantity of water soluble extractives of each species and the group of chemical compounds in the extracted liquid from each species have shown in Table 36. Between species, there is some difference in quantity of extractives and group of chemical compounds. 5. In the case of equilibrium moisture contents at different relative humidity condition, (a) Except the desorption case at 80% R. H. C. (Relative Humidity Condition), there is a definite line between untreated specimens and treated specimens that is, untreated specimens hold water more than treated specimens at the same R.H.C. (b) The specimens treated into sugar solution have shown almost the same tendency in results compared with the untreated specimens. (c) Between species, there is no any definite relation in equilibrium moisture content each other, however E. M. C. in heartwood of pine is lesser than in sapwood. This might cause from the difference of wood anatomical structure. 6. In the case of shrinkage, (a) The shrinkage value of the treated specimen into water is more than that of the untreated specimens, except anyone case of heartwood of pine at 80% R. H. C. (b) The shrinkage value of treated specimens in the sugar solution is less than that of the others and has almost the same tendency to the untreated specimens. It would mean that the penetration of some sugar into the wood can decrease the shrinkage value of wood. (c) Between species, the shrinkage value of heartwood of pine is less than sapwood of the same, shrinkage value of oak is the largest, Hymenaea is lesser than oak and more than pine. (d) Directional difference of shrinkage value through all species can also see as other all kind of species previously tested. (e) There is a definite relation in between the difference of shrinkage value of treated and untreated specimens and amount of extractives, that is, increasing extractives gives increasing the difference of shrinkage value between treated and untreated specimens. 7. In the case of swelling, (a) The swelling value of treated specimens is greater than that of the untreated specimens through all cases. (b) In comparison with the tangential direction and radial direction, the swelling value of tangential direction is larger than that of radial direction in the same species. (c) Between species, the largest one in swelling values is oak and the smallest pine heartwood, there are also a tendency that species which shrink more swell also more and, on the contrary, species which shrink lesser swell also lesser than the others. 8. In the case of specific gravity, (a) The specific gravity of the treated specimens is larger than that of untreated specimens. This reversed value between treated and untreated specimens has been resulted from the volume of specimen of oven dry condition. (b) Between species, there are differences, that is, the specific gravity of Hymenaea is the largest one and the sapwood of pine is the smallest. 9. Through this investigation, it has been concluded that soaking wood into plain water before use without any special consideration may bring more hastful results than unsoaking for use of wood. However soaking wood into the some specially provided solutions such as salt water or inorganic matter may be dissolved in it, can be profitable for the decreasing shrinkage and swelling, checking, shaking and bow etc. if soaking wood into plain water might bring the decreasing defects, it might come from even shrinking and swelling through all dimension.

  • PDF

Liability of the Compensation for Damage Caused by the International Passenger's Carrier by Air in Montreal Convention (몬트리올조약에 있어 국제항공여객운송인의 손해배상책임)

  • Kim, Doo-Hwan
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.18
    • /
    • pp.9-39
    • /
    • 2003
  • The rule of the Warsaw Convention of 1929 are well known and still being all over the world. The Warsaw Convention is undoubtedly the most widely accepted private international air law treaty with some 140 countries. In the international legal system for air transportation, the Warsaw Convention has played a major role for more than half century, and has been revised many times in consideration of the rapid developments of air high technology, changes of social and economic circumstances, need for the protection of passengers. Some amendments became effective, but others are still not effective. As a result, the whole international legal system for air transportation is at past so complicated and tangled. However, the 'Warsaw system' consists of the Warsaw Convention of 1929 the Guadalajara Convention of 1961, a supplementary convention, and the following six protocols: (1) the Hague Protocol of 1955, (2) the Guatemala Protocol of 1971, (3) the Montreal Additional Protocols, No.1, (4) the Montreal Additional Protocol No.2, (5) the Montreal Additional Protocol No.3, and (6) the Montreal Additional Protocol No.4. of 1975. As a fundamental principle of the air carrier's liability in the international convention and protocols, for instance in the Warsaw Convention and the Hague Protocol, the principle of limited liability and a presumed fault system has been adopted. Subsequently, the Montreal Inter-carrier Agreement of 1966, the Guatemala City Protocol, the Montreal Additional Protocol No.3, and the Montreal Additional Protocol No. 4 of 1975 maintained the limited liability, but substituted the presumed liability system by an absolute liability, that is, strict liability system. The Warsaw System, which sets relatively low compensation limits for victims of aircraft accidents and regulates the limited liability for death and injury of air passengers, had become increasingly outdated. Japanese Airlines and Inter-carrier Agreement of International Air Transport Association in 1995 has been adopted the unlimited liability of air carrier in international flight. The IATA Inter-Carrier Agreement, in which airlines in international air transportation agree to waive the limit of damages, was long and hard in coming, but it was remarkable achievement given the political and economic realities of the world. IATA deserves enormous credit for bringing it about. The Warsaw System is controversial and questionable. In order to find rational solution to disputes between nations which adopted differing liability systems in international air transportation, we need to reform the liability of air carriers the 'Warsaw system' and fundamentally, to unify the liability system among the nations. The International Civil Aviation Organization(ICAO) will therefore reinforce its efforts to further promote a legal environment that adequately reflects the public interest and the needs of the parties involved. The ICAO Study Group met in April, 1998, together with the Drafting Committee. The time between the "Special Group on the Modernization and Consolidation of the 'Warsaw system'(SGMW)" and the Diplomatic Conference must be actively utilized to arrange for profound studies of the outstanding issues and for wide international consultations with a view to narrowing the scope of differences and preparing for a global international consensus. From 11 to 28 May 1999 the ICAO Headquarters at Montreal hosted a Diplomatic Conference convened to consider, with a view to adoption, a draft Convention intended to modernize and to integrate replace the instruments of the Warsaw system. The Council of ICAO convened this Conference under the Procedure for the Adoption of International Conventions. Some 525 participants from 121 Contracting States of ICAO attended, one non-contracting State, 11 observer delegations from international organizations, a total of 544 registered participants took part in the historic three-week conference which began on 10 May. The Conference was a success since it adopted a new Convention for the Unification of Certain Rules for International Carriage by Air. The 1999 Montreal Convention, created and signed by representatives of 52 countries at an international conference convened by ICAO at Montreal on May 28, 1999, came into effect on November 4, 2003. Representatives of 30 countries have now formally ratified the Convention under their respective national procedures and ratification of the United States, which was the 30th country to ratify, took place on September 5, 2003. Under Article 53.6 of the Montreal Convention, it enters into force on the 60th day following the deposit of the 30th instrument of ratification or acceptation. The United States' ratification was deposited with ICAO on September 5, 2003. The ICAO have succeeded in modernizing and consolidating a 70-year old system of international instruments of private international law into one legal instrument that will provide, for years to come, an adequate level of compensation for those involved in international aircraft accidents. An international diplomatic conference on air law by ICAO of 1999 succeeded in adopting a new regime for air carrier liability, replacing the Warsaw Convention and five other related legal instruments with a single convention that provided for unlimited liability in relation to passengers. Victims of international air accidents and their families will be better protected and compensated under the new Montreal Convention, which modernizes and consolidates a seventy-five year old system of international instruments of private international law into one legal instrument. A major feature of the new legal instrument is the concept of unlimited liability. Whereas the Warsaw Convention set a limit of 125,000 Gold Francs (approximately US$ 8,300) in case of death or injury to passengers, the Montreal Convention introduces a two-tier system. The first tier includes strict liability up to l00,000 Special Drawing Rights (SDR: approximately US$ 135,000), irrespective of a carrier's fault. The second tier is based on presumption of fault of a carrier and has no limit of liability. The 1999 Montreal Convention also includes the following main elements; 1. In cases of aircraft accidents, air carriers are called upon to provide advance payments, without delay, to assist entitled persons in meeting immediate economic needs; the amount of this initial payment will be subject to national law and will be deductable from the final settlement; 2. Air carriers must submit proof of insurance, thereby ensuring the availability of financial resources in cases of automatic payments or litigation; 3. The legal action for damages resulting from the death or injury of a passenger may be filed in the country where, at the time of the accident, the passenger had his or her principal and permanent residence, subject to certain conditions. The new Montreal Convention of 1999 included the 5th jurisdiction - the place of residence of the claimant. The acceptance of the 5th jurisdiction is a diplomatic victory for the US and it can be realistically expected that claimants' lawyers will use every opportunity to file the claim in the US jurisdiction - it brings advantages in the liberal system of discovery, much wider scope of compensable non-economic damages than anywhere else in the world and the jury system prone to very generous awards. 4. The facilitation in the recovery of damages without the need for lengthy litigation, and simplification and modernization of documentation related to passengers. In developing this new Montreal Convention, we were able to reach a delicate balance between the needs and interests of all partners in international civil aviation, States, the travelling public, air carriers and the transport industry. Unlike the Warsaw Convention, the threshold of l00,000 SDR specified by the Montreal Convention, as well as remaining liability limits in relation to air passengers and delay, are subject to periodic review and may be revised once every five years. The primary aim of unification of private law as well as the new Montreal Convention is not only to remove or to minimize the conflict of laws but also to avoid conflict of jurisdictions. In order to find a rational solution to disputes between nations which have adopted differing liability systems in international air transport, we need fundamentally to reform their countries's domestic air law based on the new Montreal Convention. It is a desirable and necessary for us to ratify rapidly the new Montreal Convention by the contracting states of lCAO including the Republic of Korea. According to the Korean and Japanese ideas, airlines should not only pay compensation to passengers immediately after the accident, but also the so-called 'condolence' money to the next of kin. Condolence money is a gift to help a dead person's spirit in the hereafter : it is given on account of the grief and sorrow suffered by the next of kin, and it has risen considerably over the years. The total amount of the Korean and Japanese claims in the case of death is calculated on the basis of the loss of earned income, funeral expenses and material demage (baggage etc.), plus condolence money. The economic and social change will be occurred continuously after conclusion of the new Montreal Convention. In addition, the real value of life and human right will be enhanced substantially. The amount of compensation for damage caused by aircraft accident has increased in dollar amount as well as in volume. All air carrier's liability should extend to loss of expectation of leisure activities, as well as to damage to property, and mental and physical injuries. When victims are not satisfied with the amount of the compensation for damage caused by aircraft accident for which an airline corporation is liable under the current liability system. I also would like to propose my opinion that it is reasonable and necessary for us to interpret broadly the meaning of the bodily injury on Article 17 of the new Montreal Convention so as to be included the mental injury and condolence. Furthermore, Korea and Japan has not existed the Air Transport Act regulated the civil liability of air carrier such as Air Transport Act (Luftverkehrsgestz) in Germany. It is necessary for us to enact "the Korean Air Transport Contract Act (provisional title)" in order to regulate the civil liability of air carrier including the protection of the victims and injured persons caused by aircraft accident.

  • PDF

Information Privacy Concern in Context-Aware Personalized Services: Results of a Delphi Study

  • Lee, Yon-Nim;Kwon, Oh-Byung
    • Asia pacific journal of information systems
    • /
    • v.20 no.2
    • /
    • pp.63-86
    • /
    • 2010
  • Personalized services directly and indirectly acquire personal data, in part, to provide customers with higher-value services that are specifically context-relevant (such as place and time). Information technologies continue to mature and develop, providing greatly improved performance. Sensory networks and intelligent software can now obtain context data, and that is the cornerstone for providing personalized, context-specific services. Yet, the danger of overflowing personal information is increasing because the data retrieved by the sensors usually contains privacy information. Various technical characteristics of context-aware applications have more troubling implications for information privacy. In parallel with increasing use of context for service personalization, information privacy concerns have also increased such as an unrestricted availability of context information. Those privacy concerns are consistently regarded as a critical issue facing context-aware personalized service success. The entire field of information privacy is growing as an important area of research, with many new definitions and terminologies, because of a need for a better understanding of information privacy concepts. Especially, it requires that the factors of information privacy should be revised according to the characteristics of new technologies. However, previous information privacy factors of context-aware applications have at least two shortcomings. First, there has been little overview of the technology characteristics of context-aware computing. Existing studies have only focused on a small subset of the technical characteristics of context-aware computing. Therefore, there has not been a mutually exclusive set of factors that uniquely and completely describe information privacy on context-aware applications. Second, user survey has been widely used to identify factors of information privacy in most studies despite the limitation of users' knowledge and experiences about context-aware computing technology. To date, since context-aware services have not been widely deployed on a commercial scale yet, only very few people have prior experiences with context-aware personalized services. It is difficult to build users' knowledge about context-aware technology even by increasing their understanding in various ways: scenarios, pictures, flash animation, etc. Nevertheless, conducting a survey, assuming that the participants have sufficient experience or understanding about the technologies shown in the survey, may not be absolutely valid. Moreover, some surveys are based solely on simplifying and hence unrealistic assumptions (e.g., they only consider location information as a context data). A better understanding of information privacy concern in context-aware personalized services is highly needed. Hence, the purpose of this paper is to identify a generic set of factors for elemental information privacy concern in context-aware personalized services and to develop a rank-order list of information privacy concern factors. We consider overall technology characteristics to establish a mutually exclusive set of factors. A Delphi survey, a rigorous data collection method, was deployed to obtain a reliable opinion from the experts and to produce a rank-order list. It, therefore, lends itself well to obtaining a set of universal factors of information privacy concern and its priority. An international panel of researchers and practitioners who have the expertise in privacy and context-aware system fields were involved in our research. Delphi rounds formatting will faithfully follow the procedure for the Delphi study proposed by Okoli and Pawlowski. This will involve three general rounds: (1) brainstorming for important factors; (2) narrowing down the original list to the most important ones; and (3) ranking the list of important factors. For this round only, experts were treated as individuals, not panels. Adapted from Okoli and Pawlowski, we outlined the process of administrating the study. We performed three rounds. In the first and second rounds of the Delphi questionnaire, we gathered a set of exclusive factors for information privacy concern in context-aware personalized services. The respondents were asked to provide at least five main factors for the most appropriate understanding of the information privacy concern in the first round. To do so, some of the main factors found in the literature were presented to the participants. The second round of the questionnaire discussed the main factor provided in the first round, fleshed out with relevant sub-factors. Respondents were then requested to evaluate each sub factor's suitability against the corresponding main factors to determine the final sub-factors from the candidate factors. The sub-factors were found from the literature survey. Final factors selected by over 50% of experts. In the third round, a list of factors with corresponding questions was provided, and the respondents were requested to assess the importance of each main factor and its corresponding sub factors. Finally, we calculated the mean rank of each item to make a final result. While analyzing the data, we focused on group consensus rather than individual insistence. To do so, a concordance analysis, which measures the consistency of the experts' responses over successive rounds of the Delphi, was adopted during the survey process. As a result, experts reported that context data collection and high identifiable level of identical data are the most important factor in the main factors and sub factors, respectively. Additional important sub-factors included diverse types of context data collected, tracking and recording functionalities, and embedded and disappeared sensor devices. The average score of each factor is very useful for future context-aware personalized service development in the view of the information privacy. The final factors have the following differences comparing to those proposed in other studies. First, the concern factors differ from existing studies, which are based on privacy issues that may occur during the lifecycle of acquired user information. However, our study helped to clarify these sometimes vague issues by determining which privacy concern issues are viable based on specific technical characteristics in context-aware personalized services. Since a context-aware service differs in its technical characteristics compared to other services, we selected specific characteristics that had a higher potential to increase user's privacy concerns. Secondly, this study considered privacy issues in terms of service delivery and display that were almost overlooked in existing studies by introducing IPOS as the factor division. Lastly, in each factor, it correlated the level of importance with professionals' opinions as to what extent users have privacy concerns. The reason that it did not select the traditional method questionnaire at that time is that context-aware personalized service considered the absolute lack in understanding and experience of users with new technology. For understanding users' privacy concerns, professionals in the Delphi questionnaire process selected context data collection, tracking and recording, and sensory network as the most important factors among technological characteristics of context-aware personalized services. In the creation of a context-aware personalized services, this study demonstrates the importance and relevance of determining an optimal methodology, and which technologies and in what sequence are needed, to acquire what types of users' context information. Most studies focus on which services and systems should be provided and developed by utilizing context information on the supposition, along with the development of context-aware technology. However, the results in this study show that, in terms of users' privacy, it is necessary to pay greater attention to the activities that acquire context information. To inspect the results in the evaluation of sub factor, additional studies would be necessary for approaches on reducing users' privacy concerns toward technological characteristics such as highly identifiable level of identical data, diverse types of context data collected, tracking and recording functionality, embedded and disappearing sensor devices. The factor ranked the next highest level of importance after input is a context-aware service delivery that is related to output. The results show that delivery and display showing services to users in a context-aware personalized services toward the anywhere-anytime-any device concept have been regarded as even more important than in previous computing environment. Considering the concern factors to develop context aware personalized services will help to increase service success rate and hopefully user acceptance for those services. Our future work will be to adopt these factors for qualifying context aware service development projects such as u-city development projects in terms of service quality and hence user acceptance.

The Impact of Human Resource Innovativeness, Learning Orientation, and Their Interaction on Innovation Effect and Business Performance : Comparison of Small and Medium-Sized vs. Large-Sized Companies (인적자원의 혁신성, 학습지향성, 이들의 상호작용이 혁신효과 및 사업성과에 미치는 영향 : 중소기업과 대기업의 비교연구)

  • Yoh, Eunah
    • Korean small business review
    • /
    • v.31 no.2
    • /
    • pp.19-37
    • /
    • 2009
  • The purpose of this research is to explore differences between small and medium-sized companies and large-sized companies in the impact of human resource innovativeness(HRI), learning orientation(LO), and HRI-LO interaction on innovation effect and business performance. Although learning orientation has long been considered as a key factor influencing good performance of a business, little research was devoted to exploring the effect of HRI-LO interaction on innovation effect and business performance. In this study, it is investigated whether there is a synergy effect between innovative human workforce and learning orientation corporate culture, in addition to each by itself, to generate good business performance as well as a success of new innovations in the market. Research hypotheses were as follows, including H1) human resource innovativeness(HRI), learning orientation(LO), and interactions of HRI and LO(HRI-LO interaction) positively affect innovation effect, H2) there is a difference of the effect of HRI, LO, and HRI-LO interaction on innovation effect between large-sized and small-sized companies, H3) HRI, LO, HRI-LO interaction, innovation effect positively affect business performance, and H4) there is a difference of the effect of HRI, LO, HRI-LO interaction, and innovation effect on business performance between large-sized and small-sized companies. Data were obtained from 479 practitioners through a web survey since the web survey is an efficient method to collect a national data at a variety of fields. A single respondent from a company was allowed to participate in the study after checking whether they have more than 5-year work experiences in the company. To check whether a common source bias is existed in the sample, additional data from a convenient sample of 97 companies were gathered through the traditional survey method, and were used to confirm correlations between research variables of the original sample and the additional sample. Data were divided into two groups according to company size, such as 352 small and medium-sized companies with less than 300 employees and 127 large-sized companies with 300 or more employees. Data were analyzed through t-test and regression analyses. HRI which is the innovativeness of human resources in the company was measured with 9 items assessing the innovativenss of practitioners in staff, manager, and executive-level positions. LO is the company's effort to encourage employees' development, sharing, and utilizing of knowledge through consistent learning. LO was measured by 18 items assessing commitment to learning, vision sharing, and open-mindedness. Innovation effect which assesses a success of new products/services in the market, was measured with 3 items. Business performance was measured by respondents' evaluations on profitability, sales increase, market share, and general business performance, compared to other companies in the same field. All items were measured by using 6-point Likert scales. Means of multiple items measuring a construct were used as variables based on acceptable reliability and validity. To reduce multi-collinearity problems generated on the regression analysis of interaction terms, centered data were used for HRI, LO, and Innovation effect on regression analyses. In group comparison, large-sized companies were superior on annual sales, annual net profit, the number of new products/services in the last 3 years, the number of new processes advanced in the last 3 years, and the number of R&D personnel, compared to small and medium-sized companies. Also, large-sized companies indicated a higher level of HRI, LO, HRI-LO interaction, innovation effect and business performance than did small and medium-sized companies. The results indicate that large-sized companies tend to have more innovative human resources and invest more on learning orientation than did small-sized companies, therefore, large-sized companies tend to have more success of a new product/service in the market, generating better business performance. In order to test research hypotheses, a series of multiple-regression analysis was conducted. In the regression analysis examining the impact on innovation effect, important results were generated as : 1) HRI, LO, and HRI-LO affected innovation effect, and 2) company size indicated a moderating effect. Based on the result, the impact of HRI on innovation effect would be greater in small and medium-sized companies than in large-sized companies whereas the impact of LO on innovation effect would be greater in large-sized companies than in small and medium-sized companies. In other words, innovative workforce would be more important in making new products/services that would be successful in the market for small and medium-sized companies than for large-sized companies. Otherwise, learning orientation culture would be more effective in making successful products/services for large-sized companies than for small and medium-sized companies. Based on these results, research hypotheses 1 and 2 were supported. In the analysis of a regression examining the impact on business performance, important results were generated as : 1) innovation effect, LO, and HRI-LO affected business performance, 2) HRI by itself did not have a direct effect on business performance regardless of company size, and 3) company size indicated a moderating effect. Specifically, an effect of the HRI-LO interaction on business performance was stronger in large-sized companies than in small and medium-sized companies. It means that the synergy effect of innovative human resources and learning orientation culture tends to be stronger as company is larger. Referring to these result, research hypothesis 3 was partially supported whereas hypothesis 4 was supported. Based on research results, implications for companies were generated. Regardless of company size, companies need to develop the learning orientation corporate culture as well as human resources' innovativeness together in order to achieve successful development of innovative products and services as well as to improve sales and profits. However, the effectiveness of the HRI-LO interaction would be varied by company size. Specifically, the synergy effect of HRI-LO was stronger to make a success of new products/services in small and medium-sized companies than in large-sized companies. However, the synergy effect of HRI-LO was more effective to increase business performance of large-sized companies than that of small and medium-sized companies. In the case of small and medium-sized companies, business performance was achieved more through the success of new products/services than much directly affected by HRI-LO. The most meaningful result of this study is that the effect of HRI-LO interaction on innovation effect and business performance was confirmed. It was often ignored in the previous research. Also, it was found that the innovativeness of human workforce would not directly influence in generating good business performance, however, innovative human resources would indirectly affect making good business performance by contributing to achieving the development of new products/services that would be successful in the market. These findings would provide valuable managerial implications specifically in regard to the development of corporate culture and education program of small and medium-sized as well as large-sized companies in a variety of fields.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • Bulletin of the Korean Space Science Society
    • /
    • 1993.10a
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF