• 제목/요약/키워드: Group delay time controller

검색결과 5건 처리시간 0.018초

Design of Group Delay Time Controller Based on a Reflective Parallel Resonator

  • Chaudhary, Girdhari;Choi, Heung-Jae;Jeong, Yong-Chae;Lim, Jong-Sik;Kim, Chul-Dong
    • ETRI Journal
    • /
    • 제34권2호
    • /
    • pp.210-215
    • /
    • 2012
  • In this paper, a group delay time controller (GDTC) is proposed based on a reflection topology employing a parallel resonator as the reflection termination. The design equations of the proposed GDTC have been derived and validated by simulation and experimental results. The group delay time can be varied by varying the capacitance and inductance at an operating frequency. To show the validity of the proposed circuit, an experiment was performed for a wideband code division multiple access downlink band operating at 2.11 GHz to 2.17 GHz. According to the experiment, a group delay time variation of $3{\pm}0.17$ ns over bandwidth of 60 MHz with excellent flatness is obtained.

가변이득을 가지는 디지털제어 단상 역률보상회로 (Single-Phase Power Factor Correction(PFC) Converter Using the Variable gain)

  • 백주원;신병철;정창용;이영운;유동욱;김홍근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.240-243
    • /
    • 2001
  • This paper presents the digital controller using variable gain for single-phase power factor correction (PFC) converter. Generally, the gain of inner current control loop in single-stage PFC converter has a constant magnitude. This is why input current is distorted under low input voltage. In particular, a digital controller has more time delay than an analog controller which degrades characteristics of control loop. So, it causes the problem that the gain of current control loop isn't increased enough. In addition, the oscillation happens in the peak value of the input voltage open loop PFC system gain changes according to ac input voltage. These aspects make the design of the digital PFC controller difficult. In this paper, the improved digital control method for single-phase power factor converter is presented. The variable gain according to input voltage and input current help to improve current shape. The 800W converter is manufactured to verify the proposed control method.

  • PDF

열공정에 대한 셀 콘트롤러 운영의 설계와 해석 (Design and Analysis of Cell Controller Operation for Heat Process)

  • 소예인;전상준;김정호
    • Journal of Platform Technology
    • /
    • 제8권2호
    • /
    • pp.22-31
    • /
    • 2020
  • 생산라인의 운영 효율화, 설비의 융통성을 위하여 제조계획부터 생산에 이르기까지 산업자동화의 구축과 운영이 활발히 이루어지고 있다. ISO/TC184는 생산라인에서 지역적으로 분산되어 있는 PLC, IoT 등 프로그램식 단위제어기기(Programmable Devices)들의 정보를 공유할 수 있는 운영방식들에 대한 표준화가 진행 중이다. 본 연구에서 셀 콘트롤러의 설계는 열 공정에 대한 온도센서, 가스센서, 압력센서 등의 신호와 이를 대응하는 모터나 밸브 등의 동작을 수행하는 PLC그룹과 IoT 그룹으로 구성하였다. 셀 콘트롤러의 동작과 해석은 SDN(Software Defined Network)를 활용한 열공정에서 수행되는 공정 서비스 유형으로는 실시간(real-time) 전송 서비스, 손실에 민감한 대용량 전송 서비스, 일반(normal) 전송 서비스로 세 종류로 설정하고 수행하였다. 모의실험 결과는 SDN 경로 기법을 활용하여 결과 트래픽 증가 시에 평균 손실률은 약 17% 개선되었고, 실시간 서비스의 지연은 1ms의 낮은 수준으로 성능향상을 확인할 수 있었다.

  • PDF

Superheat Control of an Inverter-driven Heat Pump Using PI Control Algorithm

  • Park, Jong-Min;Kim, Yong-Chan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제10권2호
    • /
    • pp.106-115
    • /
    • 2002
  • The performance of an inverter-driven water-to-water heat pump with an electronic expansion valve (EEV) was measured as a function of compressor frequency, load conditions, and EEV opening. Based on the test results, a controller using proportional integral (PI) feedback or PI feedforward algorithm was designed and tested to investigate capacity modulation and transient response control of the system. Although the relation between superheat and EEV opening of the heat pump showed nonlinear characteristics, a control gain obtained at the rated frequency was applicable to various operating conditions without causing large deviations. When the simple PI feedback control algorithm was applied, a large overshoot of superheat and wet compression were observed due to time delay effects of compressor frequency. However, applying PI feedforward control scheme yielded better system performance and higher reliability, compared to the PI feedback algorithm.

광섬유 Sagnac 간섭계를 이용한 초음파의 비접촉식 감지 (Non-contact Detection of Ultrasonic Waves Using Fiber Optic Sagnac Interferometer)

  • 이정주;장태성;이승석;김영길;권일범;이왕주
    • 대한기계학회논문집A
    • /
    • 제25권9호
    • /
    • pp.1400-1409
    • /
    • 2001
  • This paper describes a fiber optic sensor suitable for non-contact detection of ultrasonic waves. This sensor is based on a fiber optic Sagnac interferometer. Quadrature phase bias between two interfering laser beams in Sagnac loop is introduced by a polarization controller. A stable quadrature phase bias can be confirmed by observing the interferometer output versus phase bias. This method eliminates a digital signal processing for detection of ultrasonic waves using Sagnac interferometer. Interference intensity is affected by the frequency of ultrasonic waves and the time delay of Sagnac loop. Collimator is attached to the end of the probing fiber to focus the light beam onto the specimen surface and to collect the reflected light back into the fiber probe. Ultrasonic waves produced by conventional ultrasonic transducers are detected. This fiber optic sensor based on Sagnac interferometer is very effective for detection of small displacement with high frequency such as ultrasonic waves used in conventional non-destructive testing.