• Title/Summary/Keyword: Groundwater system

Search Result 1,187, Processing Time 0.029 seconds

Chemical Ranking and Scoring Methodology for the Drinking and non-drinking Groundwater pollutants: CROWN (Chemical Ranking of Groundwater PollutaNts) (음용 및 비음용 지하수 우선관리대상 항목 선정기법: CROWN (Chemical Ranking of Groundwater PollutaNts))

  • An, Youn-Joo;Lee, Woo-Mi;Jeong, Seung-Woo
    • Journal of Soil and Groundwater Environment
    • /
    • v.18 no.1
    • /
    • pp.16-25
    • /
    • 2013
  • The Korean groundwater law regulates 20 groundwater contamination parameters, including 14 specific harmful substances. Expanding the number of groundwater quality standards are needed to cope with recent groundwater quality deterioration due to the use of various chemicals. Chemical ranking and scoring system (CRS) is a scientific tool to sort priority chemicals by considering exposure and toxicity potentials. In this study, we developed a CRS for scoring and ranking of possible groundwater pollutants and screened priority substances to be later considered in the Korean standard expansion. Chemical Ranking Of groundWater pollutaNts (CROWN) incorporates important parameters consisting of exposure potential, human and water ecotoxicity, interests, and certainty. Furthermore, CROWN additionally evaluated existence of other media standards to consider impacts by contamination of other media. The 197 substances that were common to 9 countries were selected first. CROWN evaluated and ranked each chemical, and finally suggested priority substances. Suggested priority substances were classified into two groups according to the groundwater use purposes: drinking and non-drinking. The priority substances were further classified into $1^{st}$ and $2^{nd}$ group priorities. The $1^{st}$ group consists of 75 substances, including the all the Korean groundwater standard parameters. CROWN will be used in selecting groundwater pollutants for possible inclusion in the Korean standard expansion.

Groundwater Recharge and Discharge in the Urban-rural Composite Area (도농복합지역 지하수 함양과 배출에 대한 연구)

  • Lee, Byung-Sun;Hong, Sung-Woo;Kang, Hee-Jun;Lee, Ji-Seong;Yun, Seong-Taek;Nam, Kyoung-Phile
    • Journal of Soil and Groundwater Environment
    • /
    • v.17 no.2
    • /
    • pp.37-46
    • /
    • 2012
  • This study was conducted to identify groundwater recharge and discharge amounts of a representative urban-rural composite area located in Yongin city, Kyounggi-do, Korea. Groundwater recharge would be affected by mainly two processes in the study area: rainfall and leakage from public water pipelines including water-supply and sewage system. Groundwater recharge rate was estimated to be 13.5% by applying annual groundwater level data from two National Groundwater Monitoring Stations to the master regression curve method. Subsequently, the recharge amounts were determined to be $13,253{\times}10^3m^3/yr$. Leakage amounts from water-supply and sewage system were estimated to be $3,218{\times}10^3$ and $5,696{\times}10^3m^3/yr$, respectively. On the whole, a total of the recharge amounts was $22,167{\times}10^3m^3/yr$, of which 60% covers rainfall recharge and 40% pipeline leakage. Groundwater discharge occurred through three processes in the composite area: baseflow, well pumping, and discharge from urban infrastructure including groundwater infiltration into sewage pipeline and artificial extraction of groundwater to protect underground facilities from submergence. Discharge amounts by baseflow flowing to the Kiheung agricultural reservoir and well pumping were estimated to be $382{\times}10^3$ and $1,323{\times}10^3m^3/yr$, respectively. Occurrence of groundwater infiltration into sewage pipeline was rarely identified. Groundwater extraction amounts from the Bundang subway line as an underground facility were identified as $714{\times}10^3m^3/yr$. Overall, a total of the discharge amounts was determined to be $2,419{\times}10^3m^3/yr$, which was contributed by 29% of artificial discharge. Even though groundwater budget of the composite area was identified to be a surplus, it should be managed for a sound groundwater environment by changing deteriorated pipelines and controlling artificial discharge amounts.

A Subsurface Environmental Management System using Spatial Information System and Groundwater Model (공간정보시스템과 지하수모형을 결합한 지하환경관리시스템의 구축)

  • Kim, Joon Hyun;Han, Young Han
    • Journal of Industrial Technology
    • /
    • v.19
    • /
    • pp.287-291
    • /
    • 1999
  • This study was performed to develop an information processing system for the sound conservation of soil and groundwater resources. The system contains the geographic spatial information system(GSIS), and the numerical model of groundwater flow and contamination. Numerical models (MODFLOW, MOC3D, MT3D, PMPATH, PEST, UCODE) and GSIS(ArcView) were integrated for the construction of an integrated management system of subsurface environment. The developed system was applied to the management of three mineral water companies located in clean mountain area. The impact of pumping over the overall catchment basin was modeled using the developed system for the decision of future management criteria.

  • PDF

Remediation Groundwater contaminated with Nitrate and Phosphate using Micellar-enhanced ultrafiltration

  • 백기태;양지원
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.04a
    • /
    • pp.334-337
    • /
    • 2002
  • The drinking water industry faces a growing number of difficultiesin the treatment of groundwater for drinking water production. Groundwater sources are frequently contaminated with nitrates and phosphates due to usage of chemical fertilizer In this study, feasibility of micellar enhanced ultrafiltation (MEUF) was investigated to remediate groundwater contaminated with nitrate and phosphate. Ultrafiltration membrane was cellulose acetate with molecular weight cut off (MWCO) 10,000 and celtyl pyridinium chloride (CPC) was used to form pollutant-micelle complex with nitrate and phosphate. The results show that nitrate and phosphate rejections are satisfactory. The removal efficiency of nitrate and phosphate show 80% and 84% in single pollutant system, respectively with 3 molar ratio of CPC to pollutants. In the multi-pollutant systems, the removalefficiency increased to 90 % and 89 % for nitrate and phosphate, respectively, The presence of nitrate in the solutions did not affect the removal of phosphate and that of phosphate did not affect the removal of nitrate. The concentration of CPC in the permeate and removal efficiency of CPC was a function of the concentration of CPC in the feed solutions.

  • PDF

3 Dimensional Numerical Simulation for the Closed Loop Heat Pump System Using TOUGH2 (TOUGH2를 이용한 폐쇄형 지열펌프 시스템의 3차원 모델링 연구)

  • Kim, Seong-Kyun;Bae, Gwang-Ok;Lee, Kang-Kun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.36-39
    • /
    • 2006
  • To evaluate the effect of groundwater flow on the outlet temperature of a geothermal heat pump, 3 dimensional numerical simulations are performed considering both groundwater flow and pipe flow in the U-tube using TOUGHS, The present study involved the following 4 simulation cases (1) no groundwater flow, (2) slow groundwater flow (hydraulic conductivity: $1.0{\times}10^{-9}m/s)$, (3) fast groundwater flow (hydraulic conductivity, $1.0{\times}10^{-7}m/s$), and (4) groundwater flow varying with the depth (hydraulic conductivity: $1.0{\times}10^{-7}-1.0{\times}10^{-10}m/s$). The effect of groundwater flow on the outlet temperature is significant where hydraulic conductivity of aquifer is $1.0{\times}10^{-7}m/s$. Where hydraulic conductivity of aquifer is $1.0{\times}10^{-10}m/s$, however, that effect is negligible.

  • PDF

Reaction Path Modelling on Geochemical Evolution of Groundwater and Formation of Secondary Minerals in Water-Gneiss Reaction System (편마암-물 반응계에서 지하수의 지화학적 진화 및 이차광물 생성에 관한 반응경로 모델링)

  • 정찬호;김천수;김통권;김수진
    • Journal of the Mineralogical Society of Korea
    • /
    • v.10 no.1
    • /
    • pp.33-44
    • /
    • 1997
  • The reaction path of water-gneiss in 200m borehole at the Soorichi site of Yugu Myeon, Chungnam was simulated by the EQ3NR/EQ6 program. Mineral composition of borehole core and fracture-filling minerals, and chemical composition of groundwater was published by authors. In this study, chemical evolution of groundwater and formation of secondary minerals in water-gneiss system was modelled on the basis of published results. The surface water was used as a starting solution for reaction. Input parameters for modelling such as mineral assemblage and their volume percent, chemical composition of mineral phases, water/rock ratio reactive surface area, dissolution rates of mineral phases were determined by experimental measurement and model fit. EQ6 modelling of the reaction path in water-gneiss system has been carried out by a flow-centered flow through open system which can be considered as a suitable option for fracture flow of groundwater. The modelling results show that reaction time of 133 years is required to reach equilibrium state in water-gneiss system, and evolution of present groundwater will continue to pH 9.45 and higher na ion concentration. The secondary minerals formed from equeous phase are kaolinite, smectite, saponite, muscovite, mesolite, celadonite, microcline and calcite with uincreasing time. Modeling results are comparatively well fitted to pH and chemical composition of borehole groudwater, secondary minerals identified and tritium age of groundwater. The EQ6 modelling results are dependent on reliability of input parameters: water-rock ratio, effective reaction surface area and dissolution rates of mineral phases, which are difficult parameters to be measured.

  • PDF

The Contamination of Groundwater by Acid Mine Drainage in the Vicinity of the Hanchang Coal Mine and the Efficiency of the Passive Treatment System (산성광산배수에 의한 한창탄광 부근 지하수의 오염과 자연정화처리시설 효율에 관한 연구)

  • 지상우;김선준
    • Journal of Soil and Groundwater Environment
    • /
    • v.8 no.2
    • /
    • pp.9-18
    • /
    • 2003
  • Sampling of waters from each stage of treatment system (Successive Alkalinity Producing System; SAPS), tailings seepage, and spring near the Hanchang coal mine of Kangwon Province were carried out seasonally and analyzed to evaluate the source and possible path of groundwater contamination by acid mine drainage (AM). Sulfur isotope compositions were measured to identify the origin of groundwater contaminations and the sulfate reduction processes in the SAPS. Low pH and high metal concentration of spring water indicates possibility of the groundwater contamination by AMD. Removal efficiency of acidity of the SAPS was 18.17 g/$\textrm{m}^2$/day on an average and the metal removal efficiency was almost 100%, which was higher than those of other treatment systems. However, no appreciable decrease of sulfur content and almost similar sulfur isotope compositions of water from each stage of the treatment system may suggest incomplete or very poor sulfate reduction by sulfate reducing bacteria. Chemical and sulfur isotope compositions showed that spring water was contaminated by seepage from mine tailings. And seepage of stonewall, a part of treatment system was affected by both tailings seepage and mine adit drainage. In this study site, the treatment system was constructed for the only AMD from mine adit not for tailings seepages, which resulted in the groundwater contamination from tailing seepages. Similar situation is expected in other abandoned coal mine areas.

Application of a Pilot-Scale Electrodialysis System for Groundwater Polluted with Arsenic and Manganese (파일롯 규모 전기투석 막여과 시스템을 이용한 비소와 망간오염 지하수 처리)

  • Choi, Su Young;Kwon, Min Wook;Park, Ki Young;Cha, Ho Young;Kim, Hee Jun;Kweon, Ji Hyang
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.3
    • /
    • pp.334-340
    • /
    • 2017
  • A pilot-scale electrodialysis system was designed and constructed to treat groundwater polluted with arsenic and manganese. Synthetic groundwater, in which some amount of arsenic and manganese was added to make 500 mg/L of Mn and $50{\mu}g/L$ of As, was used as a feed for the ED system. The limiting current density, linear water velocity, applied voltage, and membrane surface area were investigated to obtain efficient and economic operation of the ED system. The linear water velocity was increased 0.74 cm/s to 11 cm/s based on evaluation of limiting current density. The water quality of diluate for 85 minutes of operation was satisfied with water quality criteria for drinking water using the ED system with 14 pairs of ion exchange membranes. The increased membrane pairs to 21 and 42 pairs were very effective to reduce conductivities of the diluate. The operation cost of the ED system was assessed using specific energy consumption, which was $1.065{\sim}1.2kWh/m^3$. Considering low salt concentrations of the groundwater, improvement of the ED system are required to increase current utilization and to apply low voltage while the ED system was applicable to produce drinking water.