• 제목/요약/키워드: Groundwater flow model

검색결과 395건 처리시간 0.037초

Simulation of Flow Change and Level of Groundwater using MODFLOW Due to Large-size Building Construction in Metropolitan Area (MODFLOW를 이용한 도심지역 대형 건축물 신축에 따른 지하수 흐름 및 지하수위 변화예측에 관한 연구)

  • Park, Sun Hwan;Chang, Yoon Young;Rim, Hyoung Gyu
    • Journal of Environmental Impact Assessment
    • /
    • 제16권4호
    • /
    • pp.251-265
    • /
    • 2007
  • In this study, the influence of the construction of a large sized building on the flow and level of groundwater in a metropolitan area was investigated with simulation model MODFLOW for a selected area located in Gangseo-gu, Seoul, where a large business center was scheduled to be built. It was simulated that the groundwater level in the study area was suddenly lowered by the construction of a large building and groundwater in the surrounding area fast flowed into the study area. And even after the construction finished, the falling down of groundwater level consistently continued in some degree. The flow state of groundwater appeared to be the same in both cases where a soil cement wall is applied and where it is not during the construction. But for the case of application of a soil cement wall as the amount of groundwater flowing into the study site became reduced, it was estimated that the time for underground watershed getting far away from the site was also reduced and the influence of a building construction on the surrounding groundwater became reduced. Thus, it is deemed necessary that recharging the spilled ground water and rainfall into the construction area to lessen the abrupt change in flow and level of ground water should be considered in design of construction of a large sized building in a metropolitan area.

Development of Analyzing Model of Groundwater Table Fluctuation(II): Characteristics of Recharge (지하수위 변동 해석모델의 개발(II): 함양 특성)

  • Kim, Nam Won;Kim, Youn Jung;Chung, Il-Moon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • 제33권6호
    • /
    • pp.2285-2291
    • /
    • 2013
  • In this study, daily based groundwater recharge was estimated under unsteady state by using groundwater table fluctuation model developed by Kim et al. (2013). This technique analyzes groundwater variation characteristics by using reaction factor related with groundwater flow and specific yield related with recharge. For the application of this model, measured groundwater level at JD Yongdam 1 and JW Konghang for 5 years were used. This model can estimate daily based groundwater recharge and the computed groundwater levels showed good agreement with measured groundwater levels. At JD Yongdam 1 and JW Konghang, the estimated recharges (rates) were 520.4~904.0mm (32.7~61.8%) and 447.4~633.4mm (24.0~45.1%), respectively. The developed model can be suggested as an efficient and precise method to estimate daily based groundwater recharge by using groundwater level data.

Determination of the Fracture Hydraulic Parameters for Three Dimensional Discrete Fracture Network Modeling (3차원 단열망모델링을 위한 단열수리인자 도출)

  • 김경수;김천수;배대석;김원영;최영섭;김중렬
    • Journal of the Korean Society of Groundwater Environment
    • /
    • 제5권2호
    • /
    • pp.80-87
    • /
    • 1998
  • Since groundwater flow paths have one of the major roles to transport the radioactive nuclides from the radioactive waste repository to the biosphere, the discrete fracture network model is used for the rock block scale flow instead of the porous continuum model. This study aims to construct a three dimensional discrete fracture network to interpret the groundwater flow system in the study site. The modeling work includes the determination of the probabilistic distribution function from the fracture geometric and hydraulic parameters, three dimensional fracture modeling and model calibration. The results of the constant pressure tests performed in a fixed interval length at boreholes indicate that the flow dimension around boreholes shows mainly radial to spherical flow pattern. The fracture transmissivity value calculated by Cubic law is 6.12${\times}$10$\^$-7/ ㎡/sec with lognormal distribution. The conductive fracture intensity estimated by FracMan code is 1.73. Based on this intensity, the total number of conductive fractures are obtained as 3,080 in the rock block of 100 m${\times}$100 m${\times}$100 m.

  • PDF

Analyzing the Effect of Groundwater Dam Construction Using Groundwater Modeling (지하수 모델링을 통한 지하수댐 건설 효과 분석)

  • Kim, Ji-Wook;Lim, Kyung-Nam;Park, Hyun-Jin;Rhee, Bo-Kyoung
    • Journal of Soil and Groundwater Environment
    • /
    • 제18권3호
    • /
    • pp.11-22
    • /
    • 2013
  • SEAWAT, a linked modeling program of Visual MODFLOW was used to analyze the change in groundwater levels and salinity related groundwater dam construction in Cheongsan island, Wando-Gun, Jeollanam-Do. The steady-state model results show the groundwater flow and salinity distribution of the studied area. The groundwater flows from north-west and south-east highlands into the river, located in the middle part of the basin, and is eventually discharged to the ocean. Part of the sea water infiltrates into the river; and through the estuary's alluvium aquifer, the sea water intrusion takes place spreading to about 830 m from the ocean. The transient model results show that after the groundwater dam construction, groundwater levels will rise to a maximum of 2.0 m upstream, and the groundwater storage will increase 21,000 after 10 years. Meanwhile 31% of the total area affected by sea water intrusion will decrease. To conclude, the groundwater dam is a very useful method for a secure water resource in preparation for drought and water shortages in the island regions.

An Analysis of Groundwater Flow at Bugok Area Using MODFLOW (MODFLOW 모형을 이용한 부곡온천지역 지하수 유동해석)

  • Chung, Sang-Ok;Lee, Young-Dae;Min, Byung-Hyung
    • Water for future
    • /
    • 제27권1호
    • /
    • pp.79-88
    • /
    • 1994
  • This study was conducted to analyse groundwater flow in the Bugok hot spring area using the MODFLOW model which can simulate three dimensional groundwater flow both in confined and unconfined aquifers. Based on this study the following conclusions were obtained: 1) The hydraulic conductivity and the specific storage of the aquifer were 0.0135 m/day and 0.020, respectively, and the model-predicted groundwater elevation agreed well with the observed one. 2) Simulation results showed that the groundwater level declines at the end of the one-year simulation period when the annual recharge rate is small and the annual pumping rate high, which is the worst combination. Except that combination, the groundwater level does not decline at the end of one-year simulation period indication the pumping rates used were allowable. 3) The safe yield depends upon the magnitudes of the recharge and pumping rates. The pumping rate should not produce excess decline of groundwater level around April when the water level is the lowest in a year.

  • PDF

Dual-permeability Fractal Model of Groundwater Flow in Fissured Aquifers (균열대수층내 지하수유동에 관한 이중투수율 프락탈모델)

  • Bidaux, Pascal;Hamm, Se-Yeong
    • Economic and Environmental Geology
    • /
    • 제30권5호
    • /
    • pp.433-442
    • /
    • 1997
  • A dual-permeability fractal model of fluid flow is proposed. The model simulates groundwater flow in fissured dual aquifer system composed of Aquifer 1 and Aquifer 2. For this model. groundwater flow originates only from Aquifer 1 on the pumping well. The model considers wellbore storage and skin effects at the pumping well and then shows exact drawdown at the early time of pumping. Type curves for different flow dimensions and for two cases are presented and analyzed. The case 1 represents the aquifer system which consists of Aquifer 1 with low permeability and high specific storage and Aquifer 2 with high permeability and low specific storage. The case 2 is inverse to the case 1. Dimensionless drawdown curves in Aquifer 1 and Aquifer 2 shows characteristic trend each other. Consequently, the model will be useful to analyze pumping test data of different draw down patterns on the pumping well and observation wells.

  • PDF

A Study of Probabilistic Groundwater Flow Modeling Considering the Uncertainty of Hydraulic Conductivity (수리전도도의 불확실성을 고려한 확률론적 지하수 유동해석에 관한 연구)

  • Ryu Dong-Woo;Son Bong-Ki;Song Won-Kyong;Joo Kwang-Soo
    • Tunnel and Underground Space
    • /
    • 제15권2호
    • /
    • pp.145-156
    • /
    • 2005
  • MODFLOW, 3-D finite difference code, is widely used to model groundwater flow and has been used to assess the effect of excavations on the groundwater system due to construction of subways and mountain tunnels. The results of numerical analysis depend on boundary conditions, initial conditions, conceptual models and hydrogeological properties. Therefore, its accuracy can only be enhanced using more realistic and field oriented input parameters. In this study, SA(simulated annealing) was used to integrate hydraulic conductivities from a few of injection tests with geophysical reference images. The realizations of hydraulic conductivity random field are obtained and then groundwater flows in each geostatistically equivalent media are analyzed with a numerical simulation. This approach can give probabilistic results of groundwater flow modeling considering the uncertainty of hydrogeological medium. In other words, this approach makes it possible to quantify the propagation of uncertainty of hydraulic conductivities into groundwater flow.

An Analysis on Groundwater Flow Properties in the Gneiss of the Ingulam Valley (잉울암골주변 편마암에서의 지하수유동특성 분석)

  • 김계남;김재한
    • Water for future
    • /
    • 제26권4호
    • /
    • pp.47-60
    • /
    • 1993
  • The evaluation of grounwater flow in the Ingulam valley catchment area in the vicinity of SamKwang mine was studied. In this study, field hydraulic tests, groundwater flow measurement, and MODFLOW model application were carried out. The results of analysis are described as follows. The rainrate infiltrated into the ground in the study area, hardly reached the gneiss region deeper than EL.(+)100m above the surface of seawater. The rainwater infiltrated into the ground near the water system boundary, flowed out into the vicinity of streams and the travel time was between 15 and 263 years. Also, the estimated total flow rate of the groundwater in the study area was 307㎥/day.

  • PDF

Koreanized Analysis System Development for Groundwater Flow Interpretation (지하수유동해석을 위한 한국형 분석시스템의 개발)

  • Choi, Yun-Yeong
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • 제3권3호
    • /
    • pp.151-163
    • /
    • 2003
  • In this study, the algorithm of groundwater flow process was established for koreanized groundwater program development dealing with the geographic and geologic conditions of the aquifer have dynamic behaviour in groundwater flow system. All the input data settings of the 3-DFM model which is developed in this study are organized in Korean, and the model contains help function for each input data. Thus, it is designed to get detailed information about each input parameter when the mouse pointer is placed on the corresponding input parameter. This model also is designed to easily specify the geologic boundary condition for each stratum or initial head data in the work sheet. In addition, this model is designed to display boxes for input parameter writing for each analysis condition so that the setting for each parameter is not so complicated as existing MODFLOW is when steady and unsteady flow analysis are performed as well as the analysis for the characteristics of each stratum. Descriptions for input data are displayed on the right side of the window while the analysis results are displayed on the left side as well as the TXT file for this results is available to see. The model developed in this study is a numerical model using finite differential method, and the applicability of the model was examined by comparing and analyzing observed and simulated groundwater heads computed by the application of real recharge amount and the estimation of parameters. The 3-DFM model is applied in this study to Sehwa-ri, and Songdang-ri area, Jeju, Korea for analysis of groundwater flow system according to pumping, and obtained the results that the observed and computed groundwater head were almost in accordance with each other showing the range of 0.03 - 0.07 error percent. It is analyzed that the groundwater flow distributed evenly from Nopen-orum and Munseogi-orum to Wolang-bong, Yongnuni-orum, and Songja-bong through the computation of equipotentials and velocity vector using the analysis result of simulation which was performed before the pumping started in the study area. These analysis results show the accordance with MODFLOW's.

Three phase flow simulations using the fractional flow based approach with general initial and boundary conditions

  • Suk, Heejun
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 한국지하수토양환경학회 2004년도 총회 및 춘계학술발표회
    • /
    • pp.88-91
    • /
    • 2004
  • The multiphase flow simulator, MPS, is developed based on the fractional flow approach considering tile fully three phase flow with general initial and boundary condition. Most existing fractional flow-based models are limited to two-phase flow and specific boundary conditions. Although there appears a number of three-phase flow models, they were mostly developed using pressure based approaches. As a result, these models require cumbersome variable-switch techniques to deal with phase appearance and disappearance. The use of fractional flow based approach in MPS makes it unnecessary to use variable-switch to handle the change of phase configurations. Also most existing fractional flow based models consider only specific boundary conditions. However, the present model considers general boundary conditions of most possible and plausible cases which consists of ten cases.

  • PDF