• Title/Summary/Keyword: Grounding rods

Search Result 52, Processing Time 0.023 seconds

Grounding Resistance and Current Characteristics of the Planar Earth Structure using Multiple Discharge Paths (다중방전 경로를 이용한 편상접지체의 접지저항 및 전류특성)

  • Kim, Young-Sun;Kim, Dong-Min;Lee, Ki-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.9
    • /
    • pp.1564-1570
    • /
    • 2016
  • This study proposes a newly modified form of existing ground electrodes in order to secure trust of grounding system for large current caused by a stroke of lightning. Proposed planar earth structure has a several needle electrodes around a circular rod and 4 plane electrodes in all directions. The plane electrodes are fused with the insulator on the linear rod, so that they're electrically isolated. The concept is to increase the discharge amount of earth structure using multiple discharge paths like needle and plane electrodes. To check the discharge efficiency of the suggested scheme, the discharge currents are compared with typically used two kinds of ground rods. To ensure accuracy in the measurement of the discharge current, the same material was used for the comparison model. Also, the ground resistance are simulated by CDEGS commercial software and the results are compared with measured data. Based on this kind of experimental study, the suggested ground rod can be used when designing a ground system or when constructing a ground system at the site.

Property of Long vertical rod according to the different injection point with impulse current (대형 봉상 접지전극의 임펄스 인가위치에 따른 특성)

  • 이복희;장근철;엄주홍;김병근;오성균;길형준
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.369-372
    • /
    • 2003
  • To obtain a low ground resistance in high resistivity soil or in insufficient place such as downtown, long vertical ground rods are often used. However, if the lightning current or fault current with high frequency flows into the grounding system, the ground impedance is remarkedly increased. This paper presents how the impulse and fault current works on the long. vertical ground rods associated with incoming points. When the test current was injected at the bottom of ground rod, the potential waveform of ground rod includes the oscillation with high frequency.

  • PDF

A Study on the Transient Ground Impedance Modeling for Rod-type Grounding Electrodes by Frequency and Time Domain Characteristic Tests (주파수 및 시간영역 특성시험에 의한 봉형 접지전극의 과도 접지임피던스 모델링에 관한 연구)

  • Kim, Jong-Uk;Kim, Kyung-Chul;Shin, Pan-Seok;Choi, Jong-Ki;Choi, Sun-Kyu;Kim, Dong-Myung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.2
    • /
    • pp.133-141
    • /
    • 2010
  • Grounding system insures a reference potential point for electric devices and also provides a low impedance path for fault currents in the earth. The ground impedance as function of frequency is necessary for determining its performance since fault currents could contain a wide range of frequencies. Copper and concrete rod electrodes are the most commonly used grounding electrode in electric distribution systems. In this paper, the ground impedance of copper and concrete rods has been measured by frequency and time domain characteristic tests. An equivalent transfer function model of the ground impedance is identified from the measured values by using ARMA method and evaluated by comparing conventional grounding impedances.

Effects of the Position of Potential Probe on Ground Resistance Measurements Using the Fall-of-Potential Method (전위강하법에 의한 접지저항측정에 미치는 전위보조전극 위치의 영향)

  • 이복희;어주홍;김성원
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.2
    • /
    • pp.97-104
    • /
    • 2001
  • The effects of the position of potential probe on the measurements of the ground resistance in the fa11-of-potential method are described. The ground resistance is theoretically calculated by applying the 61.8[%] rule, and then the potential probe is located on the straight line between the grounding electrode to be measured and the current probe. However, sometimes the grounding electrode to be measured and the measuring potential and current probes in on-site test might not be arranged on the straight line with adequate distance because there are building, roadblock construction and other establishments. Provided that the grounding electrode to be measured and the measuring potential probes are out of position on the straight line, the measurement of the ground resistance classically falls into an error and the measured ground resistance should be corrected. In this work, measurements were focused on the grounding electrode system made by the ground rods of 2.4 m long. The measuring error was increased with increasing the angle which is made by the 3-points of the grounding electrode to be measured, the potential anti current probes, and it was a negative. That is, all of the measured ground resistances ware less than the true ground resistance.

  • PDF

Ground Impedance Characteristics Analysis of a Rod Type Grounding Electrode used for Distribution Systems (배전계통에 사용되는 봉형 접지전극의 접지 임피던스 특성 분석)

  • Kim, Kyung-Chul;Jin, Seong-Eun;Lee, Joo-Hong;Kim, You-June;Choi, Jong-Ki;Baek, Nam-Woong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.6
    • /
    • pp.67-74
    • /
    • 2005
  • Grounding insures a reference potential point for electric devices and also provides a low resistance path for fault currents in the earth. The ground impedance as a function of frequency is necessary for determining its performance since fault currents could contain a wide range of frequencies. In this paper, the ground impedance of Magic rods which are commercially available has been measured in frequency ranging from 0[Hz] up to 100[kHz] and an equivalent circuit model, transfer function model of the ground impedance are identified from the measured values.

Effects of the Current Probe on Ground Resistance Measurements Using Fall-of-Potential Method (전위강하법에 의한 접지저항측정에 미치는 전류보조전극의 영향)

  • 이복희;엄주홍
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.6
    • /
    • pp.69-77
    • /
    • 2000
  • In this paper, the effects of the positions of the potential and current probes on the measurements of the ground resistance and potential gradients with the fall-of-potential method are described and the testing techniques to minimize the measuring errors are proposed. The fall-of-potential method is theoretically based on the potential and current measuring principle and the measuring error is primarily caused by the position and ground resistance of the measuring probes. The ground resistance is calculated by applying the 61.8% and rule in the fall-of-potential method, and then the potential probe is located on the straight line between the grounding electrode to be measured and the current probe. However, sometimes the grounding electrode to be measured and the measuring probes in on-site test might not be arranged on the straight line with adequate distance because there are building, road block, construction and other establishments. Provided that the grounding electrode to be measured and the measuring probes ar out of position on the straight line or have inadequate distance, the measurement of the ground resistance classically falls into an error and the measured ground resistance should be corrected. Measurements were focused on the grounding electrode system made by the ground rods of 2.4m long. It was found that the suitable separation between the grounding electrode to be measured and the current probe is more than 5 times of the length of the grounding electrode to be measured.

  • PDF

Performance Evaluation of Early Streamer Emission Lightning Air Terminal

  • Choi, Sang-Won;Her, Yong
    • International Journal of Safety
    • /
    • v.5 no.2
    • /
    • pp.18-23
    • /
    • 2006
  • Studies have claimed that ESE (Early Streamer Emission) air terminals offer a vastly increased zone of protection over that of traditional lightning rods (Franklin rods) by causing the emission of an upward streamer/leader: The upward streamer/leader will propagate towards the tip of the downward leader at an early stage in the attachment process.. This paper shows the results of a performance evaluation test of a particular type of the ESE air terminal (called "ElecHippo") with a simple rod tested at the Korea Electrotechnology Research Institute (KERI). The corona emission current of the ElecHippo made by Yong-Jin Enterprise Corp. has also been measured at the Occupational Safety & Health Research Institute (OSHRI). The results show that the ElecHippo meets the French standard of NFC 17-102-1995. The results also verify the ESE performance by measuring the ion emission current generated in the discharge electrode gap as a function of the capacitance and inductance of the equipped devices. Finally, we propose a new method for grounding the system to reduce the lightning damage by combining the ESE air terminal, the early discharge earth plate, the lightning strike recorder and the surge protection device.

Theoretical analysis and measurement of Ground impedance of Ground rods (봉상전극 접지임피던스의 측정과 이론적 분석)

  • Lee, Bok-Hee;Lee, Tae-Hyung;Lee, Su-Bong;Eom, Ju-Hong
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1876-1878
    • /
    • 2004
  • A systematic approach of measurement, modeling and analysis of grounding system impedance is presented. The measurement and analysis system of ground impedance is based on a computer aided technique. The ground impedances of the ground rod are considerably dependent on the frequency. The ground impedance is mainly resistive in the frequency range of 3-20 kHz. At higher frequencies, the reactive components of the ground impedances are no longer negligible and the inductance of the ground rod was found to be the core factor deciding the ground impedance. As a consequence, the equivalent circuit model based on the measured data was proposed, and the calculated results were in approximately agreement with the measured data.

  • PDF

Study on the Safety of the Grounding Rods in the Distribution System (IEEE Std 80에 따른 배전용 접지동봉의 안전성 검토)

  • Kang, Moon-Ho;Lee, Heung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.470-471
    • /
    • 2006
  • 다중 접지 배전계통에서 발생하는 이상전압으로부터 전력설비의 안정적인 운영과 인체안전을 위해 주로 봉상 접지전극을 이용하여 대지방전경로를 구성하고 있다. 그리고 접지종류별로 접지 저항값을 규정하고 이를 시공에 적용하고 있다. 지락고장이 발생하면 접지전극으로 유입되는 고장전류에 비례하여 대지전위가 상승하기 때문에 이에 대한 인체 안전성측정 및 검토가 필요하다. 따라서 본 논문에서는 IEEE Std 80에서 제시하는 안전성 기준에 기초하여 다중 접지 배전계통에서 접지전극으로 널리 사용되는 봉상 접지전극을 대상으로 상용주파전류를 인가하여 대지전위상승에 따른 접촉전압을 측정하였으며, CDEGS 프로그램을 이용하여 보폭전압을 모의하였다. 또한 이 값을 IEEE Std 80에서 제시하는 최대 허용 보폭전압과 접촉전압과 비교하여 인체 안전성을 검토하였다.

  • PDF

Analysis On Simulation and Earth Resistance Evaluation By Type of Earth Rods in the Construction Grounding Testing Site (실증실험장 구축에 의한 접지전극별 접지저항 평가 및 시뮬레이션 데이터 비교 해석)

  • Han, Woon-Ki;Jung, Jin-Su;Ahn, Jae-Min;Cho, Dae-Hun
    • Proceedings of the KIEE Conference
    • /
    • 2009.04a
    • /
    • pp.203-204
    • /
    • 2009
  • 국내에 사용되고 있는 접지전극을 바탕으로 표준화된 실증실험장을 구축하였다. 구축된 실험장의 대지저항율을 측정하여 프로그램(CDEGS)을 이용한 시뮬레이션을 실시하였으며, 실증실험장의 접지전극을 IEEE Std-81.2에 의한 실험설비를 구축하여 접지저항을 측정하였으며, 시뮬레이션 데이터와 비교분석하였다. 실험결과 접지전극이 클수록 시뮬레이션 데이터와 측정값이 일치하였다. 대규모 접지전극의 경우 시뮬레이션 데이터로 접지전극의 경제적 설계가 가능함을 알 수 있었다.

  • PDF