• Title/Summary/Keyword: Grounding point

Search Result 97, Processing Time 0.024 seconds

Ground Resistance Measurement Technology Utilizing the Variation Rate (변이율을 활용한 접지저항 측정 기술)

  • Lee, Sang-Mu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.3
    • /
    • pp.51-56
    • /
    • 2005
  • Ground resistance measurement is an elementary technique for the evaluation of grounding system. There are main environmental factors to consider for correct measurement, but the problem is that it is practically most cases to measure ground resistance unable to know the factors. This paper presents a methodology toward true value of resistance in the unknown circumstance, utilizing the defined term, 'variation rate' of potential difference curve appearing in the distance to a current probe as in the three point fall-of-potential method which comprises the characteristics of environmental factors. This methodology is a induced result from the previous demostrated studies.

Magnetic Sensor Using Giant Magneto-Impedance Effect (거대자기임피던스 효과를 이용한 자기 센서)

  • Choi, Kyoo-Nam
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.6
    • /
    • pp.1057-1064
    • /
    • 2017
  • High sensitivity magnetic sensor having foreign metal detection capability is proposed utilizing giant magneto-impedance effect. Strip sensor showed the increasing output voltage when the external magnetic field was applied along with strip from strip grounding point, although the initial DC voltage varied depending on the pointing direction of strip sensor. Proposed sensor was able to eliminate more than half of background noise using active noise filter to achive high sensitivity, and it showed the capability to detect magnetized foreign metal object independent of ambient electro-magnetic noise and earth magnet. In case of ferrous sphere, the metal detection up to 0.8mm diameter was experimentally demonstrated at 5mm distance from strip sensor.

A Method of Computing the Frequency-Dependent Ground Impedance of Horizontally-buried Wires (수평으로 매설된 도선의 접지임피던스의 주파수의존성을 계산하는 기법)

  • Cho, Sung-Chul;Lee, Bok-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.5
    • /
    • pp.745-752
    • /
    • 2016
  • The parameters of Debye's equation were applied to analyze the frequency-dependent ground impedance of horizontally-buried wires. We present a new method, based on Debye's equation, of analyzing the effect of polarization on frequency-dependent ground impedance. The frequency-dependent ground impedances of a horizontally-buried wire are directly measured and calculated by applying sinusoidal current in the frequency range of 100 Hz to 10 MHz. Also, the results obtained in this work were compared with the data calculated from empirical equations and commercial programs. A new methodology using the delta-gap source model is proposed in order to calculate frequency-dependent ground impedance when the ground current is injected at the middle-point of the horizontal ground electrode. The high frequency ground impedance of horizontal electrodes longer than 30 m is larger or equal to its low frequency ground resistance. Consequently, the frequency-dependent ground impedance simulated with the proposed method is in agreement with the experimental data, and the validity of the computational simulation approach is confirmed.

Countermeasures for Preventing Electric Shock in Low-Voltage Handhole (저압 지중함에서 감전사고 방지를 위한 대책연구)

  • Kim, Chong-Min;Han, Woon-Ki;Bang, Sun-Bae;Kim, Han-Sang
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.56 no.4
    • /
    • pp.195-200
    • /
    • 2007
  • This paper describes the countermeasures for preventing the electric shock which can be occurred in the low-voltage handhole underwater. Low-voltage handholes were designed and made for the test in the testing field. Which were installed 4 cases. a metal handhole cover was employed in case 1; FRP(Fiber glass Reinforced Plastic) handhole cover in case 2; an insulated rubber was put on the joint of the cables in case 3; the exposed conductors(cover, frame etc) were commoned and grounded in case 4. Thus, an ground potential near the low-voltage handhole was measured and evaluated quantitatively for the 4 cases. The measured results show that the potential of case 2.3 were lower than that of case 1 because the insulated rubber and the FRP cover prevented direct contact to the fault point. The case 4 is the lowest among the 4 cases because the common and grounding helps the fault current release into the ground, which makes the ground potential rise lower. As a result, although each case has the defects, these ways can effectively lower the electric shock risk in the low-voltage handhole.

Verification of Reliability by the Induced Voltage of a Downscaled and Simulated 22.9kV-Y Distribution Line (축소 모의된 22.9 kV-Y 배전선로의 유도 전압에 대한 신뢰성 검증)

  • Kim, Jeom-Sik;Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.4
    • /
    • pp.26-31
    • /
    • 2015
  • The purpose of this paper is to measure the induced voltage of the downscaled and simulated overhead ground wire of a 22.9kV-Y distribution line. This study performed a test of the downscaled and simulated distribution line according to whether it is grounded or not and the value of the ground resistance. In order to verify the reliability of the data measured by the test, the data was analyzed using the Minitab 17 program. It was found that the induced voltage of the downscaled and simulated distribution line is influenced by the value of the ground resistance. It was also found that the ground resistance obtained at a certain point is closely related to whether electric poles are grounded or not. The analysis results of the measured test data with a statistical method showed that the Anderson Darling (AD) was analyzed to be the smallest as 0.188 when the ground resistance of the electric poles had been maintained at $10{\Omega}$. In addition, the P value analyzed to be 0.894 which is in the proximity of the theoretical value of 1 and verified the reliability of the test data. It could be seen that the data measured by the downscaled simulation test forms a linear graph. It is thought that if a distribution line is installed in the same manner as the downscaled, simulated distribution line, the mean induced voltage will be reduced and reliability will be increased.

Characteristics of Neutral Point Loci on Line Voltages to Hull When Insulation Resistance Collapses by Earthing Faults at 3 Phase Power Distribution Systems Onboard Vessels (선박 3상배전선로의 지락고장에 따른 대지전압 중성점의 이동경로 특성)

  • Choi, Soon-Man
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.8
    • /
    • pp.1117-1123
    • /
    • 2011
  • Ungrounded power systems are adopted onboard vessels which enable more stabilized power supply even in case of electric leakage to hull. If earthing faults happen at these systems, they make grounding impedances of power lines unbalanced each other on the three phases, resulting in high voltages to hull which can bring more possibilities of electric shocks and electric fires. This study focuses on how to configure a calculation module for transferring a grounded condition by lowered insulation resistance into a vector diagram of the voltages to hull. By using the module, the loci of neutral points were acquired to analyze how voltages to hull are affected by earthing faults and the distributed capacitances between power lines and hull. The suggested module was simulated and compared to the measured values from a test power system in good results.

Magnetic Wireless Power Transfer Antenna Using Ferrite (페라이트를 이용한 자기장 무선전력전송 안테나)

  • Ko, Nak-Young;Lee, Bon-Young;Song, Seong-Kyu;Park, Woo-Jin;Seo, Seok-Tae;Bien, Franklin
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.7
    • /
    • pp.49-54
    • /
    • 2017
  • In this paper, we propose magnetic field wireless power transfer antenna using Ferrite. It is possible to transfer magnetic field wireless power without independent ground by using characteristic of ferrite in the point that conventional magnetic field wireless power transfer was possible with independent grounding. Ferrite has a shielding effect of magnetic field and reduces leakage power, thereby improving transfer efficiency. We propose an antenna for magnetic field wireless power transfer using ferrite and confirmed that it is transmitted by 5W magnetic field wireless power through experiments. The wireless power transfer proposed in this paper can be applied variously to the Internet of things by using the magnetic field wireless power transfer through the metal.

Evaluating Geopolitical Impact through the Concept of Social Performance: The Case of a Mormon General Conference (사회적 수행의 개념을 통한 지정학적 영향의 평가 -몰몬교 연차대회를 사례로-)

  • Ethan, Yorgason
    • Journal of the Korean Geographical Society
    • /
    • v.45 no.5
    • /
    • pp.669-687
    • /
    • 2010
  • Critical scholarship has shown itself much more adept at identifying and analyzing the content of religious geopolitics than its impacts or effects. This article suggests ways in which the concept of social performance can be used to more carefully consider the effects of religious geopolitics. Judith Butler's identity-oriented notion of performativity is usually geographers' point of entry into issues of performance. But its strong poststructuralist distrust of agency limits its power among those who question poststructuralism's grounding beliefs. This article illustrates the added utility of other theories of performance-particularly the recent pragmatic, dramaturgical, and non-poststructuralist theorization of social performance by the cultural sociologist Jeffrey Alexander-in evaluating the impact of religious geopolitical action. It does so through the case of a recent, particularly geopolitically laden Mormon General Conference. It concludes, through Butler and Alexander, that this General Conference likely accomplished significant geopolitical work. But it also, mainly through Alexander, argues that this work likely had limited capacity to motivate new or additional geopolitical action. Its power was more to reinforce than transform.

Multivariate Data Analysis on Marine Casualties (다변량해석법(多變量解析法)에 의한 해난사고(海難事故)의 분석(分析))

  • Kim, Yeong-Sik;Kim, Jeong-Chang
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.6 no.2
    • /
    • pp.190-197
    • /
    • 1994
  • In this paper, 2513 marine casualties occurred in Korean waters, during 1989-1993, were analysed by the Multivariate Data Analysis Method. The main results obtained were as follows : 1. Moat of marine casualties resulted from the human factors such as careless operation and insufficient engine maintenance. Engine trouble accounted for main patten of accidents and great number of accidents occurred in fishing vessels. 2. From the point of view of the damage of human life and properties, accidents took place in cargo ships, passenger ships and tankers were serious, but in fishing vessels, those were not so serious. 3. Grounding, collision mainly resulted from careless operation, however flooding and capsizing were much affected by bad weather and material defect.

  • PDF

Development and Application of Pre/Post-processor to EMTP for Sequence Impedance Analysis of Underground Transmission Cables (지중 송전선로 대칭분 임피던스 해석을 위한 EMTP 전후처리기 개발과 활용)

  • Choi, Jong-Kee;Jang, Byung-Tae;An, Yong-Ho;Choi, Sang-Kyu;Lee, Myoung-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.10
    • /
    • pp.1364-1370
    • /
    • 2014
  • Power system fault analysis has been based on symmetrical component method, which describes power system elements by positive, negative and zero sequence impedance. Obtaining accurate line impedances as possible are very important for estimating fault current magnitude and setting distance relay accurately. Especially, accurate calculation of zero sequence impedance is important because most of transmission line faults are line-to-ground faults, not balanced three-phase fault. Since KEPCO has started measuring of transmission line impedance at 2005, it has been revealed that the measured and calculated line impedances are well agreed within reasonable accuracy. In case of underground transmission lines, however, large discrepancies in zero sequence impedance were observed occasionally. Since zero sequence impedance is an important input data for distance relay to locate faulted point correctly, it is urgently required to analyze, detect and consider countermeasures to the source of these discrepancies. In this paper, development of pre/post processor to ATP (Alternative Transient Program) version of EMTP (Electro-Magnetic Transient Program) for sequence impedance calculation was described. With the developed processor ATP-cable, effects of ground resistance and ECC (Earth Continuity Conductor) on sequence impedance were analyzed.