• 제목/요약/키워드: Grounding Electrode

검색결과 154건 처리시간 0.02초

도전율 및 유전율이 다른 병소의 검출을 위한 320-채널 다주파수 Trans-Admittance Scanner(TAS) (320-Channel Multi-Frequency Trans-Admittance Scanner(TAS) for Anomaly Detection)

  • 오동인;이민형;김희진;우응제
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권1호
    • /
    • pp.84-94
    • /
    • 2007
  • In order to collect information on local distribution of conductivity and permittivity underneath a scan probe, we developed a multi-frequency trans-admittance scanner (TAS). Applying a sinusoidal voltage with variable frequency on a chosen distal part of a human body, we measure exit currents from 320 grounded electrodes placed on a chosen surface of the subject. The electrodes are packaged inside a small and light scan probe. The system includes one voltage source and 17 digital ammeters. Front-end of each ammeter is a current-to-voltage converter with virtual grounding of a chosen electrode. The rest of the ammeter is a voltmeter performing digital phase-sensitive demodulation. Using resistor loads, we calibrate the system including the scan probe to compensate frequency-dependent variability of current measurements and also inter-channel variability among multiple. We found that SNR of each ammeter is about 85dB and the minimal measurable current is 5nA. Using saline phantoms with objects made from TX-151, we verified the performance of the lesion estimation algorithm. The error rate of the depth estimation was about 19.7%. For the size estimate, the error rate was about 15.3%. The results suggest improvement in lesion estimation algorithm based on multi-frequency trans-admittance data.

배전선로에서의 조가선 차폐 효과 연구 (A Study on a Shielding Effect of the Messenger Wires in Distribution Lines)

  • 김인수;한웅;여상민;김철환;원봉주;임용훈
    • 전기학회논문지
    • /
    • 제58권3호
    • /
    • pp.431-436
    • /
    • 2009
  • As the telecommunication lines bring into widespread use, one of the most important aspects related to power distribution systems is effectively to evaluate the effect on the telecommunication lines from power lines. One of the efficient methods to evaluate the effect is to measure the induced voltage of a telecommunication line as a result of a ground-loop. If the power lines cause high induced voltage, the ground reference in the telecommunication lines is no longer a stable potential, so signals may ride on the noise. A ground loop is common wiring conditions where a ground current may take more than one path to return to the grounding electrode at the arrangement between the power lines and telecommunication lines. When a multi-path connection between the power lines and telecommunication line circuits exists, the resulting arrangement is known as a ground loop. Whenever a ground loop exists, there are potential for damages or abnormal operations of the telecommunication lines. The power lines can induce the voltage on the communication line. The effects can be calculated by considering the inductances and capacitances. However, if we assume that there are only power lines, it doesn't have a practical meaning because there are conductors with other purpose in the neighborhood of the lines. If we consider that case, we need more complex system. Therefore we suggest more complex system considering the conductors with other purpose in the neighborhood of the lines. The neutral wires and the overhead ground wires are considered for calculating the induced voltage. We assume that there are the messenger wires beside the power line as a result of increased use of them. The main purpose of this paper is a study on a shielding effect of messenger wires in the distribution lines. EMTP(Electro-Magnetic Transients Program) program is used for the induced voltage calculation.

심전도와 심탄도의 무구속적 동시 측정을 위한 의자 등받이 개발 (Development of Chair Backrest for Non-intrusive Simultaneous Measurement of ECG and BCG)

  • 임용규
    • 융합신호처리학회논문지
    • /
    • 제19권3호
    • /
    • pp.104-109
    • /
    • 2018
  • 심전도와 심탄도를 무구속적으로 동시에 측정하는 시스템을 개발하였다. 제안된 시스템은 의자의 보조 등받이에 설치되어 맥파전달시간(PAT), Pre-ejection period (PEP) 등의 심혈관계 역학 정보를 일상생활에서 무구속적으로 측정하는 것을 목적으로 개발되었다. 본 연구에서는, 의자의 등받이에 부착된 용량성 능동전극과 용량성 접지를 이용한 간접접촉 심전도 (IDC-ECG) 측정 방법에 의해 무구속적으로 심전도를 측정하였으며, 등받이에 부착된 EMFi 압력 센서를 사용하여 무구속적으로 심탄도(ballistocardiogram)를 측정하였다. 제안된 시스템으로 심전도와 심탄도가 무구속적으로 동시에 측정됨을 확인하였으며, 측정된 심탄도는 피검자 사이에서 일정한 패턴을 보이는 것을 알 수 있었다. 또한 심전도의 Q파와 심탄도의 첫 번째 첨두간의 시간차가 pre-ejection period와 높은 상관관계를 보이는 것도 확인할 수 있었다. 이 연구에서 개발된 시스템은 심혈관계의 다양한 지표(심전도, 심박수, PAT, PEP 등)를 무구속적으로 일상생활에서 측정할 수 있음을 보였다.

간접접촉 심전도 측정에서의 간접접촉 오른발 구동 접지 성능에 대한 연구 (A Study on Performance of Indirect-contact Driven-right-leg Ground in Indirect-contact ECG Measurement)

  • 임용규;김고근;박광석
    • 융합신호처리학회논문지
    • /
    • 제9권4호
    • /
    • pp.280-287
    • /
    • 2008
  • 간접접촉 심전도(IDC-ECG) 측정에 공통 모드 잡음을 줄이기 위해 오른발 구동(Driven-right-leg) 접지 방법을 적용하고 그 접지의 성능을 조사하였다. 최근에 소개된 간접접촉 심전도 측정 기술은 전극과 인체 피부간의 직접 접촉이 필요하지 않기 때문에, 최근에 필요성이 대두되고 있는 가정에서의 장기간 무구속 심전도 측정에 적합한 측정방법으로서 현재 다양한 응용이 연구되고 있다. 그렇지만 간접접촉 심전도는 전원선에 의한 60Hz 잡음이 기존 측정 방법보다 크게 발생하여, 응용 범위의 확대에 제약 조건이 되고 있다. 본 연구에서는, 기존의 심전도 측정 방법에 사용되는 오른발 구동 접지 방법을 간접접촉 심전도 측정 방법에도 적용하여, 공통모드 잡음 성분을 반전 증폭하여 의자 좌판(seat)에 깔린 전도성 직물을 통해 인체에 feedback하였다. 이로써 피부와 직접 접촉이 없는 간접 접촉 방식의 오른발 구동 접지를 구현하였으며, 이 접지가 안정적으로 동작되고, 오른발 구동 이득이 약 1000정도에서 40dB 수준의 전원 잡음 감소 됨을 확인할 수 있었다. 이 연구의 결과로 간접접촉 심전도의 주파수 대역을 기존의 30Hz이하에서 100Hz 수준까지 높일 수 있게 되었으며, 접지 임피던스를 높일 수 있게 되어 간접접촉 심전도의 응용 분야를 더욱 넓힐 수 있게 되었다.

  • PDF