• Title/Summary/Keyword: Ground water level

Search Result 602, Processing Time 0.024 seconds

지하수위를 고려한 양수량 추정

  • 박승기;이승기;정재훈;강성민
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.09a
    • /
    • pp.13-16
    • /
    • 2002
  • The analysis of characteristics of pumping in the small tube well for agriculture were surveyed. Study area was located at the Galsinri in Yesangun near the yedang reservoir. Agricultural electricity using rates for pumping, ground water level and volume of pumping was monitored every week. Pump working ratio and pump efficiency during period of transplanting of rice showed 48.9%, 62.7% respectively.

  • PDF

The Study of Improvement Effect of Ground Settlements and Bearing Capacity by Stone Columns (스톤컬럼 공법의 지내력 증진 효과에 대한 연구)

  • Park, Sang-Kook;Lee, Song
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.4
    • /
    • pp.123-132
    • /
    • 2008
  • Aseries of in-situ tests and ground water level measurements with stone and slug materials had been conducted to find out effect of ground settlement reduction and bearing capacity improvement by the Stone Column method. As the result of the tests, it was proved that the Stone Column method is effective for reduction of ground settlement and improvement of bearing capacity. In addition the ground water level went down without overburden load. These results show that the Stone Column method is effective for an increase in density and resistance to liquefaction. The results of estimation of ground settlement and bearing capacity by general theoretical equation, it show that the Stone Column method increases bearing capacity by 2.7~5.7 times and decreases ground settlement by 2~3.5 times.

Delineation of water seepage in a reservoir embankment from ground temperature measurements (지온탐사에 의한 저수지 제방의 누수 조사)

  • 박삼규
    • Economic and Environmental Geology
    • /
    • v.32 no.2
    • /
    • pp.169-175
    • /
    • 1999
  • The water leakage of reservoir embankment usually occurs through water vein, which gives little influence on the embankment in a normal state. However, the embankment can be destroyed when the water level of reservoir increases with heavy rain in summer. Investigating the water vein and its path is therefore very important from the viewpoint of disater prevention and embankment protection. This paper presents survey results of one-meter-depth ground temperature and multi-point temperature logging in an embankment in Japan to delineate water veins and permeable formations. Four water veins have been predicted in the embankment by comparing measured one-meter-depth ground temperatures with the background ones which have no effect of water vein. The multi-point temperature logging was carried out in the borehole drilled at one of the predicted water veins. Depth and thickness of the permeable formation in the borehole can be determined from temperature restoration ratios with elapsed time. From these results we can find that the water leakage of reservoir embankment mainly occurs in sandy soil formation in the embankment.

  • PDF

Seepage and Slope Stability Analysis on the Site of Debris-flow at Jinbu Area (진부지역 토석류발생 사면에 대한 침투 및 사면안정 연계해석)

  • Jun, Kyoung-Jea;Yune, Chan-Young;Seo, Heung-Seok
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.369-376
    • /
    • 2009
  • Field investigation was performed right after the occurrence of debris flow at Jinbu area. Geomorphic and geotechnical characteristics were investigated and rain fall data were collected. Based on these data, seepage and slope stability analysis was performed to verify the behavior of ground water and factor of safety of the slope according to the rainfall intensity and time. As a results, the minimum value of factor of safety achieved in long time after the moment of maximum precipitation rate. And it is confirmed that the factor of safety is susceptible to ground water level rather than rainfall intensity.

  • PDF

A Study on the Analysis of Monitoring Settlement Considering the History of the Groundwater Level in the Dredged Landfill Area Affected by Algae (조류의 영향을 받는 준설매립지역에서 지하수위 이력을 고려한 계측침하 분석에 관한 연구)

  • Jang, Ji-Gun;Son, Su-Won;Hong, Seok-Woo
    • Journal of the Korean Geotechnical Society
    • /
    • v.37 no.7
    • /
    • pp.13-23
    • /
    • 2021
  • If roads, bridges, buildings, etc. are built on the ground with soft clay or organic soil, there may be a lot of problems in geotechnical engineering such as settlement and stability due to the large settlement and lack of bearing capacity. In extreme cases, it may appear due to shear failure or collapse of the constructed structure, so a ground improvement method is indispensable to increase the strength of the ground and to suppress settlement. In this study, the settlement according to each groundwater level condition was analyzed using the measurement results for the groundwater level conditions, one of the important factors in predicting the settlement in dredged and reclaimed ground, and the groundwater level conditions applied to the settlement analysis were proposed by comparing it with settlement generated 5 years after construction. As a result of the analysis, it is judged that it is reasonable to apply the measured groundwater level during construction and the low water ordinary neap tide (L.W.O.N.T) during load application for the groundwater level in the settlement analysis. In addition, in the case of the dredged and reclaimed ground, it is estimated that the water pressure acting on the clay layer is nonlinear, as the result of the observations of the head of water at the observation points above and below the in-situ clay layer were different.

Evaluation of Groundwater Flow by Gravel-Filling and Temporary Drainage in Groundwater-saturated Limestone Mine Cavities (지하수 포화 석회석 채굴공동에서의 골재 충전 및 임시배수시 발생하는 지하수 유동 평가)

  • Choi, Woo-Seok;Kang, Byung-Chun;Kim, Eun-Sup;Shin, Dong-Choon
    • Tunnel and Underground Space
    • /
    • v.27 no.4
    • /
    • pp.205-216
    • /
    • 2017
  • Fluctuations in groundwater level are the major cause of ground subsidence in the abandoned limestone mine. In this study, evaluation of groundwater flow under three different cases of natural condition, aggregate-filling, temporary drainage in groundwater-saturated limestone mine cavities was executed by 3-dimensional analysis. In the case of aggregate-filling, although the water level both in the upper ground of mine cavities and an agricultural watershed was elevated, it was lower than the water level fluctuation of an agricultural water use and rainfall and the flow rate was similar to the flow rate of natural condition. In the case of temporary drainage, as the water level in the upper ground of mine cavities and an agricultural watershed decrease rapidly and the flow rate has increased by 25times, so the risk of ground subsidence increased.

Development of High Precision Underground Water Level Meter Using a Buoyant Rod Load Cell Technique (부력 추를 이용한 지하수위 측정용 센서 개발)

  • Lee Bu-Yong;Park Byoung-Yoon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.1 no.1
    • /
    • pp.36-40
    • /
    • 1999
  • A new method was developed to measure underground water level with high reliability. The principle of new method was to detect a change of a buoyant force according to change in water level of underground water measured by the use of a straingage load cell. Field test of the instrument was carried out in Cheju Island. The results were as follows; 1) The present study provided a possibility to develop a new underground water level meter. 2) This new instrument accomplished high reliability at field test in Cheju Island. 3) There is possibility of development of water level meter which measure various range of water level to detect a weight change of a buoyant forcd.

  • PDF

Evaluation of Groundwater Flow on Railroad Tunnel Excavation (철도 터널 공사시 지하수 발생량 산정에 관한 연구)

  • Oa Seong-Wook;Ahn Tae-Bong;Choi Seung-Seon
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.448-453
    • /
    • 2005
  • Tunnel excavation is an inevitable process for railroad construction in Korea and it being a one of the major issues of its environmental impact assessment. Ground water flow by tunnel excavation is an important parameter to determine environmental effects. The current method to determine the ground water flow is used a unit number induced a highway construction site. But it does not consider any site characteristics; ground water level, soil properties and others. The purpose of this study is to suggest the determination way of ground water flow considering site characteristics in tunnel construction.

  • PDF

A Study on the Drinking Water Quality for Primary Lunch School in Seoul (서울지역 급식 국민학교의 음용수 수질에 관한 연구)

  • 이원묘;이용옥;방형애
    • Journal of Environmental Health Sciences
    • /
    • v.21 no.1
    • /
    • pp.7-20
    • /
    • 1995
  • The aims of this study are to enhance the students' knowledge of the drinking water and its reliability by investigating drinking water situation on the drinking water. The results are as following 1. Status and drinking behavior about school drinking water (1) 97.82% of the schools are using the tap water as the resource of drinking water. (2) 46 schools are in possession of water tank and 18 schools of them are using the water tank as the resource of drinking water. The clearing and sanitization of the tank are carried out once in a year with hypochloronatrium by the low-level officials. (3) 51.28% of the schools are providing the students with drinking water and 75% of them with boiled water. The drinking water supply managers are low-level officials, nurse teachers, and dietitian. 2. Analysis of the drinking water quality (1) Most of the drinking water provided by the school are tap water 35.8%, barely tea 5.85%, filtered water 6.3%, ground water 1.1% and all turned out to be suitable for drinking. (2) The drinking water carried from home turned out to be unsuitable for drinking except pH criterion, especially the test of APC(Aerobic Plate Count) and Coliform group showed worse degree. These results were caused by the hygiene problem and maltreatment in water container.

  • PDF

지하수 채수에 따른 지반침하 사례분석

  • 정하익;구호본
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2001.09a
    • /
    • pp.168-171
    • /
    • 2001
  • It is a common practice to extract water from the ground for domestic, agricultural or industrial uses or to lower the groundwater level for construction work. An accurate prediction of ground settlement Is sometimes crucial when groundwater is pumped. This case study have shown that drawdown of the groundwater table may cause ground subsidence. Many settlement gauges was installed in the vicinity of a pumped well to measure the surface settlement. The relationships between the level of groundwater drop and surface settlement is investigated In this research.

  • PDF