Study on long-term monitoring of heat exchanger installed in the tunnel lining (터널 라이닝 내부에 설치한 열교환기의 현장모니터링 연구)

  • Lee, Chulho;Park, Moonseo;Choi, Hangseok;Sohn, Byunghu;Jeoung, Jaehyeung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.195.1-195.1
    • /
    • 2011
  • This paper presents an experimental study on a new potential geothermal energy source obtained from tunnel structures. An "energy textile", which is a textile-type ground heat exchanger, was fabricated between a shotcrete layer and a guided drainage geotextile in the tunnel lining system. To examine the long-term thermal behavior of the energy textile, the difference in temperatures of the inlet and outlet fluid circulating through the heat exchange pipe within the energy textile was monitored using a constant-temperature water bath. Daily heat exchange rate of the energy textile during cooling operation was estimated from the measured temperatures of the inlet and outlet fluid through the energy textile. The air and ground temperature was also continuously monitored. The operation of the energy textile as a ground heat exchanger was simulated using a 3D numerical CFD model (Fluent). The thermal conductivity of shotcrete and concrete lining components and temperature variation of air in the tunnel were incorporated in the model. The numerical analysis shows a good agreement with the long-term monitoring result.

  • PDF

A Measurement of Temperature by TLC without Contact and A Study of Thermocapillary Flow under Ground-based Conditions (TLC 비접촉 온도측정과 중력장에서 열모세관 현상 구명)

  • 엄용균;유재봉
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1071-1075
    • /
    • 2003
  • In a closed square cavity filled with a liquid, a cooled the upper horizontal wail and a heated the lower horizontal wall, the flow isn't generated under the ground-based condition when Rayleigh number is lower than 1700. In such case the flow phenomena near an air bubble under a cooled horizontal wall were investigated. The temperature and the flow fields were studied by using the Thermo-sensitive Liquid-Crystal and the image processing. The qualitative analysis for the temperature and the flow fields were carried out by applying the image processing technique to the original data. Injecting bubble at the center point of upper cooled wall, the symmetry shape of two vortexes near an air bubble was observed. The bubble size increased, the size of velocity and the magnitude of velocity increased. In spite of elapsed time, a pair of two vortexes was the unique and steady-state flow in a square cavity and wasn't induce to the other flow in the surround region.

  • PDF

HBr Formation from the Reaction between Gas-phase Bromine Atom and Vibrationally Excited Chemisorbed Hydrogen Atoms on a Si(001)-(2 X1) Surface

  • Ree, J.;Yoon, S.H.;Park, K.G.;Kim, Y.H.
    • Bulletin of the Korean Chemical Society
    • /
    • 제25권8호
    • /
    • pp.1217-1224
    • /
    • 2004
  • We have calculated the probability of HBr formation and energy disposal of the reaction exothermicity in HBr produced from the reaction of gas-phase bromine with highly covered chemisorbed hydrogen atoms on a Si (001)-(2 ${\times}$1) surface. The reaction probability is about 0.20 at gas temperature 1500 K and surface temperature 300 K. Raising the initial vibrational state of the adsorbate(H)-surface(Si) bond from the ground to v = 1, 2 and 3 states causes the vibrational, translational and rotational energies of the product HBr to increase equally. However, the vibrational and translational motions of product HBr share most of the reaction energy. Vibrational population of the HBr molecules produced from the ground state adsorbate-surface bond ($v_{HSi}$ =0) follows the Boltzmann distribution, but it deviates seriously from the Boltzmann distribution when the initial vibrational energy of the adsorbate-surface bond increases. When the vibration of the adsorbate-surface bond is in the ground state, the amount of energy dissipated into the surface is negative, while it becomes positive as vHSi increases. The energy distributions among the various modes weakly depends on surface temperature in the range of 0-600 K, regardless of the initial vibrational state of H(ad)-Si(s) bond.

Cooling and Heating Performance Evaluation of a GSHP System (지열원 열펌프 시스템의 냉${\cdot}$난방 성능 평가)

  • Sohn Byong Hu;Cho Chung-Sik;Shin Hyun-Jun;An Hyung-Jun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • 제17권1호
    • /
    • pp.71-81
    • /
    • 2005
  • The main objective of the present study is to investigate the performance characteristics of a ground-source heat pump(GSHP) system with a 130 m vertical and 62 mm nominal diameter U-tube ground heat exchanger. In order to evaluate the performance analysis, the ground-source heat pump connected to a test room with $90\;m^2$ floor area in the Korea Institute of Construction $Technology(37^{\circ}39'N,\;126^{\circ}48'E)$ was designed and constructed. This ground-source heat pump system mainly consisted of ground heat exchanger, indoor heat pumps and measuring devices. The cooling and heating loads of the test room were 5.5 and 7.2 kW at design conditions, respectively. The experimental results were obtained from July 2, 2003 to July 1, 2004. The cooling and heating performance coefficients of the system were determined from the measured data. The average cooling and heating COPs for the system were obtained to be 4.90 and 3.96, respectively. The temperature variations in ground and the ground heat exchanger pipe surface at different depths were also measured.

Comparison of Surface and Air Temperature depending on Cover Materials in Playground (운동장의 피복 유형별 표면 및 대기온도 비교)

  • Lee, Hak Hyeong;Kwon, Oh Gyung;Shin, Jin He;Kabir, Faisal Md.;Lee, Kang Su;Ryu, Sungpil;Lee, Dong Woon
    • Weed & Turfgrass Science
    • /
    • 제4권1호
    • /
    • pp.71-75
    • /
    • 2015
  • Playground is frequently used for physical and sports activity by students as well as by common people, which is constructed with various cover materials on the ground. This research surveyed the surface temperature in Kyungpook National University Sangju campus playground which is covered with various cover materials [bare field, zoysiagrass (Zoysia japonica) turf field, urethane track, concrete field, epoxy field and artificial turf field] in Sangju, Gyeongsangbukdo, Korea. Temperature was measured 4 times per day at 09:00, 12:00, 15:00, and 18:00 from May to October 2014 in surface and 1 m height above the ground. Surface temperature was different, depending on cover materials and survey time. Bare field and zoysiagrass turf field was lower surface temperature than other sites. Higher surface temperature site was different depending on survey time. Urethane track and artificial turf field was hotter than other sites at 12 and 15 hours, however concrete and epoxy field was hot at 18 hours. One meter above ground temperature was the highest in artificial turf field except at 18 hours. So natural turf, zoysiagrass playground will increase the athletic performance by reduce the surface and above ground temperature.

Seasonal Variation of Fish Catch by a Set Net in Hamdeuk Fishing Ground off Jeju Island (제주도 함덕 연안의 정치망 어획량 변동)

  • CHA Byung-Yul;CHANG Dae-Soo;KIM Byung-Yeob
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • 제37권1호
    • /
    • pp.65-72
    • /
    • 2004
  • Fish catch by a set net in Hamdeuk fishing ground off Jeju Island were studied to determine seasonal variation of species composition and catch from 1998 to 2000. A total 72,022.9 kg was caught during the survey period, including Scomber japonicus and Trachurus japonicus of $76.4\%$ in the total. The other dominant species were Siganus fuscescens, Loligo chinesis, Seriola dumerili, Sepioteuthis lessoniana, Sardinops melanostictus, and Seriola lalandi accounting to $20.0\%$ of the total. The fishing period conducted by a set net in Hamdeuk fishing ground were from May to November. The catch by a set net were higher in summer than in spring and autumn and closely related with the seasonal variation of sea water temperature. The catch was higher in 1998 than In 1999 and 2000, which was related to the sea water temperature in fishing ground.

A Study on the Content of Manganese and Chrome in the Ground Water in Seoul Area (Based on non-water supply area) (서울 일부지역 정호수의 망간, 크롬함량 조사연구 상수시설 미설치지역을 중심으로)

  • 구성회;우세홍;이성호;이부웅
    • Journal of Environmental Health Sciences
    • /
    • 제1권1호
    • /
    • pp.41-45
    • /
    • 1974
  • A study was carried out to determine the content of Mn and Cr in the ground water in Seoul area, where municipal water supply system was not installed, from Nov. 1 to Nov. 30, 1973. In this study, authors examined the hardness, pH, water temperature and Cl ion to investigate the general conditions of the ground water. For this study, samples were collected from 46 wells which were located in outpart of Seoul city, and Mn and Cr were determined with the Spectronic-20. The following results were obtained: 1) Average value of the ground water conditions of the wells were 13.3$\circ$C in temperature, pH 6.3, hardness 159 ppm and Cl ion 41 ppm. 2) In the manganese concentration, the highest area was Yeongdeungpo-Ku(0.318 ppm), while the lowest area was Sungbuk-Ku(0.065 ppm) and the mean concentration of the whole district was 0.196 ppm. 3) In the chrome concentration, the highest area was Yeongdeungpo-Ku(0.031 ppm), while the lowest area was Dobong-Ku (trace) and the mean concentration of the whole district was 0.012 ppm.

  • PDF

A Study on Selection of Pipe Materials Considering EWT (EWT를 고려한 지중열교환기 파이프 선정에 관한 연구)

  • Ryu, Hyung-Kyou;Chung, Min-Ho;Lee, Byung-Seok;Choi, Hyun-Jun;Choi, Hang-Seok
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • 제10권2호
    • /
    • pp.13-18
    • /
    • 2014
  • This paper proposes an optimum pipe material (PVC vs. PE) design & selection for open loop ground heat exchangers. Heat exchange efficiency and/or workability, and the need for trench insulation were investigated by comparing EWT (cooling mode) of each system. CFD simulations for the PVC and PE pipe with the same inner diameter show similar EWT. This is because the PVC pipe has a small thickness but a low thermal conductivity as compared to the PE pipe, and thus these two properties tend to offset each other. However, a hypothetically insulated pipe led to a meaningful drop of EWT. This means pipe insulation is of importance in performance of ground heat exchangers. From analyzing climate data and system operation, it is not advantageous to insulate trench pipes due to construction difficulties and ground temperature characteristics that are seasonally varied.

A Study on the Heating Performance of Ground Source Heat Pump System (지중열원 열펌프 시스템의 난방성능 해석)

  • Woo Joung-Son;Kim Dae-Ki;Lee Se-Kyoun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • 제16권12호
    • /
    • pp.1175-1182
    • /
    • 2004
  • Installations of vertical boreholes for the ground source heat pump system are expensive to install. One way to reduce the initial cost is to increase the specific heat extraction rate of borehole system. However, as the specific heat extraction rate increases the temperature of borehole fluid decreases with the resultant lower Coefficient Of Performance in Heating(COPH) of heat pump system. The purpose of this study is to provide the basic informations about the performance of heat pump system with the specific heat extraction rate and soil thermal properties such as thermal conductivity and temperature. It is shown that the specific heat extraction rate is the most important parameter for the ground source heat pump system. To obtain the reasonable COPH value (COPH > 3) the heat extraction rate should be about 25 W/m or less. Accurate measurements of soil thermal properties are also very important to design the system properly. The effects of borehole thermal resistances are also examined in this study.

Analysis of Recent 30-year Climate Characteristics by Natural Geography (자연지형 구분에 의한 최근 30년간 기후특성 분석)

  • Ryu, Yeon-Soo;Park, Mi-Lan;Kim, Jin-Wook;Joo, Hye-Jin
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 춘계학술발표대회 논문집
    • /
    • pp.256-262
    • /
    • 2011
  • Environmental pollution by Using of a fossil fuel, a reckless and growth-oriented development since the Industrial Revolution has caused global change of environment. An issue largest among this is a climate change. A global mean temperature since 19th century has climbed up $0.4{\sim}0.8^{\circ}C$. After The Kyoto Protocol regarding a greenhouse gas reduction goal took effect, be situations that decrease of greenhouse gas was acutely required. Interest of utilization of the new & renewable energy is increasing every day. This study shows that at first divided a country to nine range by natural geography, and second executed Meteorological data analysis of recent 30 years considering level of significance by nine range. The results of this study are that in heating load calculation of building, periodic temperature data management is required because facility capacity and cost are affected greatly by outdoor temperature, and temperature by climate range needs consideration of pertinent area. Lastly, ground temperature was assumed of the weather in region, the ground and soil.

  • PDF